{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T17:51:36Z","timestamp":1773856296642,"version":"3.50.1"},"reference-count":30,"publisher":"ASME International","issue":"11","content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2013,11,1]]},"abstract":"<jats:p>Steady flow simulations of blood flow in an axisymmetric stenosed artery, subjected to a static magnetic field, are performed to investigate the influence of artery size, magnetic field strength, and non-Newtonian behavior on artery wall shear stress and pressure drop in the stenosed section. It is found that wall shear stress and pressure drop increase by decreasing artery size, assuming non-Newtonian fluid, and increasing magnetic field strength. In the computations, the shear thinning behavior of blood is accounted for by the Carreau\u2013Yasuda model. Computational results are compared and found to be inline with available experimental data.<\/jats:p>","DOI":"10.1115\/1.4025107","type":"journal-article","created":{"date-parts":[[2013,7,29]],"date-time":"2013-07-29T16:31:07Z","timestamp":1375115467000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":20,"title":["Computational Modeling of Non-Newtonian Blood Flow Through Stenosed Arteries in the Presence of Magnetic Field"],"prefix":"10.1115","volume":"135","author":[{"given":"Aiman","family":"Alshare","sequence":"first","affiliation":[{"name":"Assistant Professor Department of Mechatronics Engineering, German Jordanian University, Amman 11180, Jordan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bourhan","family":"Tashtoush","sequence":"additional","affiliation":[{"name":"Professor Department of Mechanical Engineering, Jordan University of Science and Technology, Irbid 22110, Jordan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hossam H.","family":"El-Khalil","sequence":"additional","affiliation":[{"name":"Assistant Professor Department of Biomedical Engineering, Jordan University of Science and Technology, Irbid 22110, Jordan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"33","published-online":{"date-parts":[[2013,9,23]]},"reference":[{"key":"2019100314482367000_B1","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1161\/01.CIR.74.5.1085","article-title":"Effect of a Reduction in Blood Viscosity on Maximal Myocardial Oxygen Delivery Distal to a Moderate Coronary Stenosis","volume":"74","year":"1986","journal-title":"Circulation"},{"issue":"1","key":"2019100314482367000_B2","doi-asserted-by":"crossref","first-page":"011003","DOI":"10.1115\/1.2838029","article-title":"Effect of Blood Viscosity on Oxygen Transport in Residual Stenosed Artery Following Angioplasty","volume":"130","year":"2008","journal-title":"ASME J. Biomech. Eng."},{"key":"2019100314482367000_B3","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1016\/S0021-9150(01)00656-6","article-title":"Hypertriglyceridemia is Associated With an Elevated Blood Viscosity Rosenson: Triglycerides and Blood Viscosity","volume":"161","year":"2002","journal-title":"Atherosclerosis"},{"key":"2019100314482367000_B4","doi-asserted-by":"crossref","first-page":"812","DOI":"10.1016\/j.compbiomed.2011.06.017","article-title":"Computational Simulation of Aortic Aneurysm Using FSI Method: Influence of Blood Viscosity on Aneurismal Dynamic Behaviors","volume":"41","year":"2011","journal-title":"Comput. Biol. Med."},{"key":"2019100314482367000_B5","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1042\/cs0710137","article-title":"Blood Rheology in Arterial Disease","volume":"71","year":"1986","journal-title":"Clin. Sci."},{"key":"2019100314482367000_B6","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1161\/01.HYP.5.5.757","article-title":"Elevated Blood Viscosity in Patients With Borderline Essential Hypertension","volume":"5","year":"1983","journal-title":"Hypertension"},{"key":"2019100314482367000_B7","first-page":"171","article-title":"Alteration of Blood Hemorheologic Properties During Cerebral Ischemia and Reperfusion in Rats","volume":"34","year":"2000","journal-title":"J. Biomech."},{"key":"2019100314482367000_B8","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1016\/S0011-393X(00)88508-2","article-title":"Effects of Nitroglycerin on Blood Viscosity and Hemodynamics","volume":"60","year":"1999","journal-title":"Curr. Ther. Res."},{"key":"2019100314482367000_B9","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1177\/039139880903200603","article-title":"Effect of Hemodialysis on Whole Blood Viscosity","volume":"32","year":"2009","journal-title":"Int. J. Artif. Organs"},{"key":"2019100314482367000_B10","doi-asserted-by":"crossref","first-page":"1044","DOI":"10.1016\/j.amjcard.2003.12.059","article-title":"Effect of Low-Density Lipoprotein Cholesterol Apheresis on Blood Viscosity","volume":"93","year":"2004","journal-title":"Am. J. Cardiol."},{"key":"2019100314482367000_B11","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1051\/ject\/2003352143","article-title":"Quantification of the Effect of Altering Hematocrit and Temperature on Blood Viscosity","volume":"35","year":"2003","journal-title":"J. Extra Corpor. Technol."},{"key":"2019100314482367000_B12","doi-asserted-by":"crossref","first-page":"259","DOI":"10.3233\/CH-2008-1135","article-title":"Effect of Disodium Monofluorphosphate on Plasma and Blood Viscosity in the Rat","volume":"40","year":"2008","journal-title":"Clin. Hemorheol. Microcirc."},{"issue":"1\u20132","key":"2019100314482367000_B13","first-page":"180","article-title":"Apparent Viscosity of Human Blood in a High Static Magnetic Field","volume":"225","year":"2001","journal-title":"J. Magn. Magn. Mater."},{"issue":"3","key":"2019100314482367000_B14","first-page":"499","article-title":"Experimental Studies on Blood Flow in Stenosis Arteries in Presence of Magnetic Field","volume":"20","year":"2008","journal-title":"Ultra Sci."},{"issue":"2","key":"2019100314482367000_B15","doi-asserted-by":"crossref","first-page":"1635","DOI":"10.1016\/j.amc.2006.11.019","article-title":"Effect of a Magnetic Field on the Resistance to Blood Flow Through Stenotic Artery","volume":"188","year":"2007","journal-title":"Appl. Math. Comput."},{"key":"2019100314482367000_B16","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1016\/j.physd.2007.08.006","article-title":"Biomagnetic Fluid Flow in a Channel With Stenosis","volume":"237","year":"2008","journal-title":"Physica D"},{"issue":"1","key":"2019100314482367000_B17","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1016\/j.cam.2008.11.010","article-title":"Unsteady Response of Non-Newtonian Blood Flow Through a Stenosed Artery in Magnetic Field","volume":"230","year":"2009","journal-title":"J. Comput. Appl. Math."},{"key":"2019100314482367000_B18","doi-asserted-by":"crossref","unstructured":"Li, J., and Huang, H., 2010, \u201cEffect of Magnetic Field on Blood Flow and Heat Transfer Through a Stenosed Artery,\u201d Proceedings of the 3rd International Conference on Biomedical Engineering and Informatics, pp. 2028\u20132032.","DOI":"10.1109\/BMEI.2010.5639654"},{"issue":"3","key":"2019100314482367000_B19","doi-asserted-by":"crossref","first-page":"752","DOI":"10.1016\/j.ijheatfluidflow.2008.02.014","article-title":"Numerical Analysis of Blood Flow in Realistic Arteries Subjected to Strong Non-Uniform Magnetic Fields","volume":"29","year":"2008","journal-title":"Int. J. Heat Fluid Flow"},{"issue":"1","key":"2019100314482367000_B20","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.jmmm.2010.08.023","article-title":"Numerical Study of Magnetic Nanoparticles Concentration in Biofluid (Blood) Under Influence of High Gradient Magnetic Field","volume":"323","year":"2011","journal-title":"J. Magn. Magn. Mater."},{"issue":"5","key":"2019100314482367000_B21","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1007\/BF00694447","article-title":"The Effects of Erythrocythemia on Blood Viscosity, Maximal Systemic Oxygen Transport Capacity and Maximal Rates of Oxygen Consumption in an Amphibian","volume":"155","year":"1985","journal-title":"J. Comp. Physiol. [B]"},{"key":"2019100314482367000_B22","doi-asserted-by":"crossref","unstructured":"Sankar, D. S., Jaafar, N. A., Ismail, A. I. M., and Nagar, A., 2011, \u201cMathematical Modeling of a Complex System for MHD Flow in Hemodynamics,\u201d Proceedings of the 6th International Conference on Bio-Inspired Computing Theories and Applications, pp. 324\u2013328.","DOI":"10.1109\/BIC-TA.2011.47"},{"key":"2019100314482367000_B23","first-page":"297","article-title":"Magnetic Field Effect On Blood Flow Through a Multi-Stenosed Artery","volume":"43","year":"2007","journal-title":"Heat Mass Transfer"},{"issue":"4","key":"2019100314482367000_B24","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1007\/s007910050039","article-title":"Computational Vascular Fluid Dynamics: Problems, Models and Methods","volume":"2","year":"2000","journal-title":"Comput. Visualization Sci."},{"issue":"2","key":"2019100314482367000_B25","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1080\/10255840500180799","article-title":"Shape Optimisation in Steady Blood Flow: A Numerical Study of Non-Newtonian Effects","volume":"8","year":"2005","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"2019100314482367000_B26","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1016\/S0021-9290(99)00015-9","article-title":"The Influence of the Non-Newtonian Properties of Blood on the Flow in Large Arteries: Steady Flow in a Carotid Bifurcation Model","volume":"32","year":"1999","journal-title":"J. Biomech."},{"issue":"9","key":"2019100314482367000_B27","doi-asserted-by":"crossref","first-page":"093103","DOI":"10.1063\/1.2772250","article-title":"Analysis of the Casson and Carreau\u2013Yasuda Non-Newtonian Blood Models in Steady and Oscillatory Flows Using the Lattice Boltzmann Method","volume":"19","year":"2007","journal-title":"Phys. Fluids"},{"key":"2019100314482367000_B28","first-page":"135","volume-title":"Rheology: Principles, Measurements and Applications","year":"1994"},{"key":"2019100314482367000_B29","first-page":"345","article-title":"Effect of Static Magnetic Field Exposure of Up to 8 Tesla on Sequential Human Vital Sign Measurements","volume":"18","year":"2003","journal-title":"J. Magn. Reson. Imaging"},{"key":"2019100314482367000_B30","doi-asserted-by":"crossref","unstructured":"Tiari, S., Ahmadpour-B, M., Tafazzoli-Shadpour, M., and Sadeghi, M. R., 2011, \u201cAn Experimental Study of Blood Flow in a Model of Coronary Artery With Single and Double Stenosis,\u201d Proceedings of the 18th Iranian Conference on Biomedical Engineering (ICBME), pp. 14\u201316.","DOI":"10.1109\/ICBME.2011.6168580"}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4025107\/6089608\/bio_135_11_114503.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4025107\/6089608\/bio_135_11_114503.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,30]],"date-time":"2025-04-30T13:31:01Z","timestamp":1746019861000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/doi\/10.1115\/1.4025107\/370925\/Computational-Modeling-of-NonNewtonian-Blood-Flow"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,9,23]]},"references-count":30,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2013,11,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4025107","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,9,23]]},"article-number":"114503"}}