{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,24]],"date-time":"2026-07-24T23:57:35Z","timestamp":1784937455525,"version":"3.55.0"},"reference-count":32,"publisher":"ASME International","issue":"7","content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2014,7,1]]},"abstract":"<jats:p>A majority of the middle-aged population exhibit cervical spondylosis that may require decompression and fusion of the affected level. Minimally invasive cervical fusion is an attractive option for decreasing operative time, morbidity, and mortality rates. A novel interfacet joint spacer (DTRAX facet screw system, Providence Medical) promises minimally invasive deployment resulting in decompression of the neuroforamen and interfacet fusion. The present study investigates the effectiveness of the device in minimizing intervertebral motion to promote fusion, decompression of the nerve root during bending activity, and performance of the implant to adhere to anatomy during repeated bending loads. We observed flexion, extension, lateral bending, and axial rotation resonant overshoot mode (ROM) in cadaver models of c-spine treated with the interfacet joint spacer (FJ spacer) as stand-alone and supplementing anterior plating. The FJ spacer was deployed bilaterally at single levels. Specimens were placed at the limit of ROM in flexion, extension, axial bending, and lateral bending. 3D images of the foramen were taken and postprocessed to quantify changes in foraminal area. Stand-alone spacer specimens were subjected to 30,000 cycles at 2\u2009Hz of nonsimultaneous flexion-extension and lateral bending under compressive load and X-ray imaged at regular cycle intervals for quantitative measurements of device loosening. The stand-alone FJ spacer increased specimen stiffness in all directions except extension. 86% of all deployments resulted in some level of foraminal distraction. The rate of effective distraction was maintained in flexed, extended, and axially rotated postures. Two specimens demonstrated no detectable implant loosening (&lt;0.25\u2009mm). Three showed unilateral subclinical loosening (0.4\u2009mm maximum), and one had subclinical loosening bilaterally (0.5\u2009mm maximum). Results of our study are comparable to previous investigations into the stiffness of other stand-alone minimally invasive technologies. The FJ spacer system effectively increased stiffness of the affected level comparable to predicate systems. Results of this study indicate the FJ spacer increases foraminal area in the cervical spine, and decompression is maintained during bending activities. Clinical studies will be necessary to determine whether the magnitude of decompression observed in this cadaveric study will effectively treat cervical radiculopathy; however, results of this study, taken in context of successful decompression treatments in the lumbar spine, are promising for the continued development of this product. Results of this biomechanical study are encouraging for the continued investigation of this device in animal and clinical trials, as they suggest the device is well fixated and mechanically competent.<\/jats:p>","DOI":"10.1115\/1.4026363","type":"journal-article","created":{"date-parts":[[2014,1,3]],"date-time":"2014-01-03T20:39:17Z","timestamp":1388781557000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":14,"title":["Biomechanical Evaluation of an Interfacet Joint Decompression and Stabilization System"],"prefix":"10.1115","volume":"136","author":[{"given":"Jeremi M.","family":"Leasure","sequence":"first","affiliation":[{"name":"The Taylor Collaboration, St. Mary's Medical Center, San Francisco, CA 94117"},{"name":"San Francisco Orthopaedic Residency Program, San Francisco, CA 94117 e-mail:"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jenni","family":"Buckley","sequence":"additional","affiliation":[{"name":"The Taylor Collaboration, St. Mary's Medical Center, San Francisco, CA 94117"},{"name":"University of Delaware Department of Mechanical Engineering, Newark, DE 19716"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"33","published-online":{"date-parts":[[2014,5,22]]},"reference":[{"key":"2019100600432510900_B1","first-page":"196","article-title":"Necropsy Observations on the Spinal Cord in Cervical Spondylosis","volume":"86","year":"1965","journal-title":"Riv. Patol. Nerv. Ment."},{"key":"2019100600432510900_B2","first-page":"1082","article-title":"Prevalence of Cervical Spondylosis in a General Practice","volume":"22","year":"1965","journal-title":"Lancet"},{"key":"2019100600432510900_B3","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1093\/brain\/77.2.274","article-title":"Cervical Spondylosis; Incidence and Implications","volume":"77","year":"1954","journal-title":"Brain"},{"key":"2019100600432510900_B4","doi-asserted-by":"crossref","first-page":"2260","DOI":"10.1097\/01.brs.0000142434.02579.84","article-title":"Presymptomatic Spondylotic Cervical Cord Compression","volume":"29","year":"2004","journal-title":"Spine"},{"issue":"1","key":"2019100600432510900_B5","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1148\/radiology.164.1.3588931","article-title":"Asymptomatic Degenerative Disk Disease and Spondylosis of the Cervical Spine: MR Imaging","volume":"164","year":"1987","journal-title":"Radiology"},{"issue":"3","key":"2019100600432510900_B6","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1097\/00007632-200002010-00005","article-title":"The Anatomic Relation Among the Nerve Roots, Intervertebral Foramina, and Intervertebral Discs of the Cervical Spine","volume":"25","year":"2000","journal-title":"Spine"},{"key":"2019100600432510900_B7","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1136\/ard.35.4.289","article-title":"Qualitative Changes With Age of Proteoglycans of Human Lumbar Discs","volume":"35","year":"1976","journal-title":"Ann. Rheum. Dis."},{"issue":"Pt. 2","key":"2019100600432510900_B8","first-page":"325","article-title":"Epidemiology of Cervical Radiculopathy. A Population-Based Study From Rochester, Minnesota, 1976 Through 1990","year":"1994","journal-title":"Brain"},{"issue":"Suppl.","key":"2019100600432510900_B9","first-page":"30","article-title":"Cervical Spondylotic Myelopathy: 10 Years of Prospective Outcome Analysis of Anterior Decompression and Fusion","year":"2005","journal-title":"Surg Neurol."},{"key":"2019100600432510900_B10","first-page":"515","article-title":"Cervical Transfacet Versus Lateral Mass Screws: A Biomechanical Comparison","year":"2000","journal-title":"J. Spinal Disord."},{"key":"2019100600432510900_B11","doi-asserted-by":"crossref","first-page":"E865","DOI":"10.1097\/BRS.0b013e318184ace8","article-title":"Biomechanical Differences Between Transfacet and Lateral Mass Screw-Rod Constructs for Multilevel Posterior Cervical Spine Stabilization","volume":"33","year":"2008","journal-title":"Spine"},{"key":"2019100600432510900_B12","doi-asserted-by":"crossref","first-page":"897","DOI":"10.1097\/01.brs.0000158937.64577.25","article-title":"Biomechanical Comparison of Transarticular Facet Screws to Lateral Mass Plates in Two-Level Instrumentations of the Cervical Spine","volume":"30","year":"2005","journal-title":"Spine"},{"issue":"5","key":"2019100600432510900_B13","first-page":"553-e5\u2013553-e8","article-title":"Anterior Thigh Compartment Syndrome and Local Myonecrosis After Posterior Spine Surgery on a Jackson Table","volume":"78","year":"2012","journal-title":"World Neurosurg"},{"key":"2019100600432510900_B14","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1007\/s00234-004-1197-z","article-title":"Factors Predicting Excellent Outcome of Percutaneous Cervical Discectomy: Analysis of 111 Consecutive Cases","volume":"46","year":"2004","journal-title":"Neuroradiology"},{"key":"2019100600432510900_B15","doi-asserted-by":"crossref","first-page":"E16","DOI":"10.1097\/BRS.0b013e3181891772","article-title":"Biomechanical Pullout Strength and Stability of the Cervical Artificial Pedicle Screw","volume":"34","year":"2009","journal-title":"Spine"},{"key":"2019100600432510900_B16","doi-asserted-by":"crossref","first-page":"341","DOI":"10.3171\/SPI\/2008\/8\/4\/341","article-title":"Biomechanical Comparison of Three Fixation Techniques for Unstable Thoracolumbar Burst Fractures. Laboratory Investigation","volume":"8","year":"2008","journal-title":"J. Neurosurg. Spine"},{"issue":"7","key":"2019100600432510900_B17","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1097\/01.brs.0000157483.28505.e3","article-title":"The Treatment Mechanism of an Interspinous Process Implant for Lumbar Neurogenic Intermittent","volume":"30","year":"2005","journal-title":"Spine"},{"issue":"3","key":"2019100600432510900_B18","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/j.clinbiomech.2006.08.006","article-title":"Hybrid Multidirectional Test Method to Evaluate Spinal Adjacent-Level Effects","volume":"22","year":"2007","journal-title":"Clin. Biomech."},{"issue":"12","key":"2019100600432510900_B19","doi-asserted-by":"crossref","first-page":"1548","DOI":"10.1097\/00007632-200006150-00015","article-title":"Load-Carrying Capacity of the Human Cervical Spine in Compression Is Increased Under a Follower Load","volume":"25","year":"2000","journal-title":"Spine"},{"issue":"4","key":"2019100600432510900_B20","first-page":"449\u2013458","article-title":"Porous-Coated Versus Grit-Blasted Surface Texture of Hydroxyapatite-Coated Implants During Controlled Micromotion","volume":"13","year":"1998","journal-title":"J. Arthroplasty"},{"issue":"2","key":"2019100600432510900_B21","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/S0021-9290(03)00307-5","article-title":"Neutral Zone and Range of Motion in the Spine Are Greater With Stepwise Loading Than With a Continuous Loading Protocol. An in vitro Porcine Investigation","volume":"37","year":"2004","journal-title":"J. Biomech."},{"issue":"1","key":"2019100600432510900_B22","first-page":"559","article-title":"Construction of Local Vertebral Coordinate Systems Using a Digitizing Probe. Technical Note","volume":"1","year":"1997","journal-title":"Spine"},{"issue":"2","key":"2019100600432510900_B23","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.spinee.2006.04.015","article-title":"Biomechanical Comparison of Two-Level Cervical Locking Posterior Screw\/Rod and Hook\/Rod Techniques","volume":"7","year":"2007","journal-title":"Spine J."},{"issue":"25","key":"2019100600432510900_B24","doi-asserted-by":"crossref","first-page":"2958","DOI":"10.1097\/01.brs.0000247797.92847.7d","article-title":"Influence of X Stop on Neural Foramina and Spinal Canal Area in Spinal Stenosis","volume":"31","year":"2006","journal-title":"Spine"},{"issue":"17","key":"2019100600432510900_B25","doi-asserted-by":"crossref","first-page":"1882","DOI":"10.1097\/BRS.0b013e31817e7019","article-title":"Annual Frequency and Magnitude of Neck Motion in Healthy Individuals","volume":"33","year":"2008","journal-title":"Spine"},{"issue":"4","key":"2019100600432510900_B26","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1097\/BRS.0b013e31819481b1","article-title":"Prophylactic Vertebroplasty May Reduce the Risk of Adjacent Intact Vertebra From Fatigue Injury: An Ex Vivo Biomechanical Study","volume":"34","year":"2009","journal-title":"Spine"},{"issue":"17","key":"2019100600432510900_B27","doi-asserted-by":"crossref","first-page":"1863","DOI":"10.1097\/BRS.0b013e31817d6dd3","article-title":"Rest Cannot Always Recover the Dynamic Properties of Fatigue-Loaded Intervertebral Disc","volume":"33","year":"2008","journal-title":"Spine"},{"issue":"1 Suppl.","key":"2019100600432510900_B28","first-page":"151","article-title":"Biomechanical Comparison of Two Stabilization Techniques of the Atlantoaxial Joints: Transarticular Screw Fixation Versus Screw and Rod Fixation","volume":"56","year":"2005","journal-title":"Neurosurgery"},{"issue":"18","key":"2019100600432510900_B29","doi-asserted-by":"crossref","first-page":"1894","DOI":"10.1097\/00007632-199909150-00006","article-title":"Differential Biomechanical Effects of Injury and Wiring at C1\u2013C2","volume":"24","year":"1999","journal-title":"Spine"},{"issue":"25","key":"2019100600432510900_B30","doi-asserted-by":"crossref","first-page":"E934","DOI":"10.1097\/01.brs.0000247956.00599.a3","article-title":"New Rod-Plate Anterior Instrumentation for Thoracolumbar\/Lumbar Scoliosis: Biomechanical Evaluation Compared With Dual-Rod and Single-Rod With Structural Interbody Support","volume":"31","year":"2006","journal-title":"Spine"},{"issue":"2 Suppl.","key":"2019100600432510900_B31","first-page":"252","article-title":"In Vitro Biomechanical Analysis of Three Anterior Thoracolumbar Implants","volume":"93","year":"2000","journal-title":"J. Neurosurg."},{"issue":"3","key":"2019100600432510900_B32","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1097\/00007632-199902010-00004","article-title":"Biomechanical Studies on Two Anterior Thoracolumbar Implants in Cadaveric Spines","volume":"24","year":"1999","journal-title":"Spine"}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4026363\/6090605\/bio_136_07_071010.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4026363\/6090605\/bio_136_07_071010.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,6]],"date-time":"2019-10-06T04:43:48Z","timestamp":1570337028000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/doi\/10.1115\/1.4026363\/472806\/Biomechanical-Evaluation-of-an-Interfacet-Joint"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,5,22]]},"references-count":32,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2014,7,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4026363","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,5,22]]},"article-number":"071010"}}