{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T13:08:44Z","timestamp":1784639324395,"version":"3.55.0"},"reference-count":55,"publisher":"ASME International","issue":"10","content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2014,10,1]]},"abstract":"<jats:p>Bileaflet mechanical heart valves (BMHVs) are among the most popular prostheses to replace defective native valves. However, complex flow phenomena caused by the prosthesis are thought to induce serious thromboembolic complications. This study aims at employing a novel multiscale numerical method that models realistic sized suspended platelets for assessing blood damage potential in flow through BMHVs. A previously validated lattice-Boltzmann method (LBM) is used to simulate pulsatile flow through a 23\u2009mm St. Jude Medical (SJM) Regent\u2122 valve in the aortic position at very high spatiotemporal resolution with the presence of thousands of suspended platelets. Platelet damage is modeled for both the systolic and diastolic phases of the cardiac cycle. No platelets exceed activation thresholds for any of the simulations. Platelet damage is determined to be particularly high for suspended elements trapped in recirculation zones, which suggests a shift of focus in blood damage studies away from instantaneous flow fields and toward high flow mixing regions. In the diastolic phase, leakage flow through the b-datum gap is shown to cause highest damage to platelets. This multiscale numerical method may be used as a generic solver for evaluating blood damage in other cardiovascular flows and devices.<\/jats:p>","DOI":"10.1115\/1.4028105","type":"journal-article","created":{"date-parts":[[2014,7,29]],"date-time":"2014-07-29T04:33:17Z","timestamp":1406608397000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":26,"title":["Blood Damage Through a Bileaflet Mechanical Heart Valve: A Quantitative Computational Study Using a Multiscale Suspension Flow Solver"],"prefix":"10.1115","volume":"136","author":[{"given":"B.","family":"Min Yun","sequence":"first","affiliation":[{"name":"G.W. Woodruff School of Mechanical Engineering, 801 Ferst Drive, Atlanta, GA 30332-0405 e-mail:"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cyrus K.","family":"Aidun","sequence":"additional","affiliation":[{"name":"G.W. Woodruff School of Mechanical Engineering, 801 Ferst Drive, Atlanta, GA 30332-0405"},{"name":"Parker H. Petit Institute for Bioengineering and Bioscience, 315 Ferst Dr. NW, Atlanta, GA 30332 e-mail:"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ajit P.","family":"Yoganathan","sequence":"additional","affiliation":[{"name":"G.W. Woodruff School of Mechanical Engineering, 801 Ferst Drive, Atlanta, GA 30332-0405"},{"name":"Parker H. Petit Institute for Bioengineering and Bioscience, 315 Ferst Dr. NW, Atlanta, GA 30332"},{"name":"Wallace H. Coulter Department of Biomedical Engineering, School of Chemical and Biomolecular Engineering, 313 Ferst Drive, Atlanta, GA 30332-0535 e-mail:"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"33","published-online":{"date-parts":[[2014,8,12]]},"reference":[{"issue":"3","key":"2019100315032520200_B1","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1016\/j.ejcts.2006.06.013","article-title":"Mechanical Versus Bioprosthetic Valve Replacement in Middle-Aged Patients","volume":"30","year":"2006","journal-title":"Eur. J. Cardiothorac. Surg."},{"key":"2019100315032520200_B2","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1007\/978-3-642-76846-0_4","article-title":"Mechanical and Other Problems of Artificial Valves","volume":"86","year":"1994","journal-title":"Curr. Topic Pathol."},{"key":"2019100315032520200_B3","first-page":"795","article-title":"Heart Valve Bioengineering","volume-title":"Encyclopedia of Comprehensive Structural Integrity","year":"2003"},{"key":"2019100315032520200_B4","first-page":"e523","article-title":"Focused Update Incorporated Into the ACC\/AHA 2006 Guidelines for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology\/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease): Endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons","volume":"118","year":"2008","journal-title":"Circulation"},{"issue":"5","key":"2019100315032520200_B5","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1177\/039139889001300507","article-title":"Estimation of Shear Stress-Related Blood Damage in Heart Valve Prostheses\u2014In Vitro Comparison of 25 Aortic Valves","volume":"13","year":"1990","journal-title":"Int. J. Artif. Organs"},{"issue":"(1)","key":"2019100315032520200_B6","first-page":"83","article-title":"A Comparison of the Hinge and Near-Hinge Flow Fields of the St. Jude Medical Hemo-Dynamic Plus and Regent Bileaflet Mechanical Heart Valves","volume":"119","year":"2000","journal-title":"J. Thorac. Cardiovasc. Surg."},{"issue":"6","key":"2019100315032520200_B7","first-page":"591","article-title":"Velocity Measurements and Flow Patterns Within the Hinge Region of a Medtronic Parallel Bileaflet Mechanical Heart Valve With Clear Housing","volume":"5","year":"1996","journal-title":"J. Heart Valve Dis."},{"issue":"10","key":"2019100315032520200_B8","doi-asserted-by":"crossref","first-page":"1361","DOI":"10.1016\/S0021-9290(01)00084-7","article-title":"A Re-evaluation and Discussion on the Threshold Limit for Hemolysis in a Turbulent Shear Flow","volume":"34","year":"2001","journal-title":"J. Biomech."},{"issue":"5","key":"2019100315032520200_B9","doi-asserted-by":"crossref","first-page":"1410","DOI":"10.1016\/S0735-1097(98)00385-4","article-title":"Differentiating Thrombus From Pannus Formation in Obstructed Mechanical Prosthetic Valves: An Evaluation of Clinical, Transthoracic and Transesophageal Echocardiographic Parameters","volume":"32","year":"1998","journal-title":"J. Am. Coll. Cardiol."},{"issue":"3","key":"2019100315032520200_B10","doi-asserted-by":"crossref","first-page":"646","DOI":"10.1016\/S0735-1097(10)80178-0","article-title":"Obstruction of Mechanical Heart Valve Prostheses: Clinical Aspects and Surgical Management","volume":"17","year":"1991","journal-title":"J. Am. Coll. Cardiol."},{"issue":"4","key":"2019100315032520200_B11","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1016\/0002-9149(72)90571-1","article-title":"Mechanical Malfunction and Thrombosis of Prosthetic Heart Valves","volume":"30","year":"1972","journal-title":"Am. J. Cardiol."},{"issue":"9","key":"2019100315032520200_B12","doi-asserted-by":"crossref","first-page":"094507","DOI":"10.1115\/1.4005167","article-title":"Near Valve Flows and Potential Blood Damage During Closure of a Bileaflet Mechanical Heart Valve","volume":"133","year":"2011","journal-title":"ASME J. Biomech. Eng."},{"issue":"3","key":"2019100315032520200_B13","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1007\/BF02368237","article-title":"Particle Image Velocimetry in the Investigation of Flow Past Artificial Heart Valves","volume":"22","year":"1994","journal-title":"Ann. Biomed. Eng."},{"issue":"5","key":"2019100315032520200_B14","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1016\/S0021-9290(98)00026-8","article-title":"Steady Flow Dynamics of Prosthetic Aortic Heart Valves: A Comparative Evaluation With PIV Techniques","volume":"31","year":"1998","journal-title":"J. Biomech."},{"issue":"11","key":"2019100315032520200_B15","doi-asserted-by":"crossref","first-page":"1417","DOI":"10.1016\/S0021-9290(01)00132-4","article-title":"Pulsatile Flow Studies of a Porcine Bioprosthetic Aortic Valve In Vitro: PIV Measurements and Shear-Induced Blood Damage","volume":"34","year":"2001","journal-title":"J. Biomech."},{"issue":"9","key":"2019100315032520200_B16","doi-asserted-by":"crossref","first-page":"840","DOI":"10.1046\/j.1525-1594.2003.07194.x","article-title":"Regurgitant Flow Field Characteristics of the St. Jude Bileaflet Mechanical Heart Valve Under Physiologic Pulsatile Flow Using Particle Image Velocimetry","volume":"27","year":"2003","journal-title":"Artif. Organs"},{"issue":"6","key":"2019100315032520200_B17","doi-asserted-by":"crossref","first-page":"1166","DOI":"10.1016\/j.jbiomech.2008.01.024","article-title":"Passive Flow Control of Bileaflet Mechanical Heart Valve Leakage Flow","volume":"41","year":"2008","journal-title":"J. Biomech."},{"issue":"1","key":"2019100315032520200_B18","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s10439-007-9398-3","article-title":"Procoagulant Properties of Flow Fields in Stenotic and Expansive Orifices","volume":"36","year":"2008","journal-title":"Ann. Biomed. Eng."},{"issue":"7","key":"2019100315032520200_B19","doi-asserted-by":"crossref","first-page":"071011","DOI":"10.1115\/1.4001260","article-title":"Reduction of Procoagulant Potential of b-Datum Leakage Jet Flow in Bileaflet Mechanical Heart Valves via Application of Vortex Generator Arrays","volume":"132","year":"2010","journal-title":"ASME J. Biomech. Eng."},{"key":"2019100315032520200_B20","doi-asserted-by":"crossref","first-page":"067105","DOI":"10.1063\/1.2743261","article-title":"Vorticity Dynamics of a Bileaflet Mechanical Heart Valve in an Axisymmetric Aorta","volume":"19","year":"2007","journal-title":"Phys. Fluids"},{"issue":"2","key":"2019100315032520200_B21","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1007\/s10439-007-9411-x","article-title":"Characterization of Hemodynamic Forces Induced by Mechanical Heart Valves: Reynolds vs. Viscous Stresses","volume":"36","year":"2008","journal-title":"Ann. Biomed. Eng."},{"issue":"15","key":"2019100315032520200_B22","doi-asserted-by":"crossref","first-page":"2637","DOI":"10.1016\/j.jbiomech.2012.08.009","article-title":"Evaluation of Shear Stress Accumulation on Blood Components in Normal and Dysfunctional Bileaflet Mechanical Heart Valves Using Smoothed Particle Hydrodynamics","volume":"45","year":"2012","journal-title":"J. Biomech."},{"key":"2019100315032520200_B23","first-page":"259","article-title":"Direct Numerical Simulation of the Pulsatile Flow Through an Aortic Bileaflet Mechanical Heart Valve","volume":"622","year":"2010","journal-title":"J. Fluid Mech."},{"issue":"16","key":"2019100315032520200_B24","doi-asserted-by":"crossref","first-page":"7587","DOI":"10.1016\/j.jcp.2008.04.028","article-title":"Curvilinear Immersed Boundary Method for Simulating Fluid Structure Interaction With Complex 3D Rigid Bodies","volume":"227","year":"2008","journal-title":"J. Comput. Phys."},{"issue":"11","key":"2019100315032520200_B25","doi-asserted-by":"crossref","first-page":"111005","DOI":"10.1115\/1.4002491","article-title":"The Effect of Implantation Orientation of a Bileaflet Mechanical Heart Valve on Kinematics and Hemodynamics in an Anatomic Aorta","volume":"132","year":"2010","journal-title":"ASME J. Biomech. Eng."},{"issue":"9","key":"2019100315032520200_B26","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1111\/j.1525-1594.2007.00446.x","article-title":"Flow-Induced Platelet Activation and Damage Accumulation in a Mechanical Heart Valve: Numerical Studies","volume":"31","year":"2007","journal-title":"Artif. Organs"},{"issue":"5","key":"2019100315032520200_B27","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1097\/MAT.0b013e3181e65bf9","article-title":"Design Optimization of a Mechanical Heart Valve for Reducing Valve Thrombogenicity\u2014A Case Study With ATS Valve","volume":"56","year":"2010","journal-title":"ASAIO"},{"issue":"4","key":"2019100315032520200_B28","doi-asserted-by":"crossref","first-page":"558","DOI":"10.1115\/1.2746378","article-title":"Comparison of the Hemodynamic and Thrombogenic Performance of Two Bileaflet Mechanical Heart Valves Using a CFD\/FSI Model","volume":"129","year":"2007","journal-title":"ASME J. Biomech. Eng."},{"issue":"11","key":"2019100315032520200_B29","doi-asserted-by":"crossref","first-page":"3295","DOI":"10.1007\/s10439-010-0086-3","article-title":"Numerical Investigation of the Performance of Three Hinge Designs of Bileaflet Mechanical Heart Valves","volume":"38","year":"2010","journal-title":"Ann. Biomed. Eng."},{"issue":"2","key":"2019100315032520200_B30","doi-asserted-by":"crossref","first-page":"897","DOI":"10.1007\/s10439-010-0184-2","article-title":"Numerical Investigation of the Effects of Channel Geometry on Platelet Activation and Blood Damage","volume":"39","year":"2011","journal-title":"Ann. Biomed. Eng."},{"issue":"7","key":"2019100315032520200_B31","doi-asserted-by":"crossref","first-page":"1468","DOI":"10.1007\/s10439-011-0502-3","article-title":"A Numerical Investigation of Blood Damage in the Hinge Area of Aortic Bileaflet Mechanical Heart Valves During the Leakage Phase","volume":"40","year":"2012","journal-title":"Ann. Biomed. Eng."},{"key":"2019100315032520200_B32","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1017\/jfm.2014.54","article-title":"Computational Modelling of Flow Through Prosthetic Heart Valves Using the Entropic Lattice-Boltzmann Method","volume":"743","year":"2014","journal-title":"J. Fluid Mech."},{"key":"2019100315032520200_B33","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1017\/jfm.2014.393","article-title":"Highly Resolved Pulsatile Flows Through Prosthetic Heart Valves Using the Entropic Lattice-Boltzmann Method","volume":"754","year":"2014","journal-title":"J. Fluid Mech."},{"issue":"1","key":"2019100315032520200_B34","first-page":"49","article-title":"Lattice Boltzmann Simulation of Solid Particles Suspended in Fluid","volume":"81","year":"1995","journal-title":"J. Stat. Phys."},{"issue":"1","key":"2019100315032520200_B35","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1146\/annurev-fluid-121108-145519","article-title":"Lattice Boltzmann Method for Complex Flows","volume":"42","year":"2010","journal-title":"Annu. Rev. Fluid Mech."},{"key":"2019100315032520200_B36","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1017\/S0022112098002493","article-title":"Direct Analysis of Particulate Suspensions With Inertia Using the Discrete Boltzmann Equation","volume":"373","year":"1998","journal-title":"J. Fluid Mech."},{"key":"2019100315032520200_B37","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1017\/S0022112000001932","article-title":"The Dynamics and Scaling Law for Particles Suspended in Shear Flow With Inertia","volume":"423","year":"2000","journal-title":"J. Fluid Mech."},{"issue":"3","key":"2019100315032520200_B38","first-page":"685","article-title":"Extension of the Lattice-Boltzmann Method for Direct Simulation of Suspended Particles Near Contact","volume":"112","year":"2003","journal-title":"J. Stat. Phys."},{"issue":"7","key":"2019100315032520200_B39","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1002\/fld.2043","article-title":"Simulating 3D Deformable Particle Suspensions Using Lattice Boltzmann Method With Discrete External Boundary Force","volume":"62","year":"2010","journal-title":"Int. J. Numer. Method Fluids"},{"issue":"1","key":"2019100315032520200_B40","first-page":"165","article-title":"Rigorous Navier\u2013Stokes Limit of the Lattice Boltzmann Equation","volume":"35","year":"2003","journal-title":"Asymptotic Anal."},{"issue":"1","key":"2019100315032520200_B41","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1007\/s00211-008-0196-0","article-title":"Convergence of Lattice Boltzmann Methods for Navier\u2013Stokes Flows in Periodic and Bounded Domains","volume":"112","year":"2009","journal-title":"Numerische Math."},{"key":"2019100315032520200_B42","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1017\/S0962492902000077","article-title":"The Immersed Boundary Method","volume":"11","year":"2002","journal-title":"Acta Numer."},{"issue":"(3)","key":"2019100315032520200_B43","first-page":"202","article-title":"A Method for Direct Simulation of Flexible Fiber Suspensions Using Lattice-Boltzmann Equation With External Boundary Force","volume":"36","year":"2010","journal-title":"Int. J. Multiphase Flow"},{"issue":"3","key":"2019100315032520200_B44","doi-asserted-by":"crossref","first-page":"036712","DOI":"10.1103\/PhysRevE.75.036712","article-title":"Entropic Lattice Boltzmann Representations Required to Recover Navier\u2013Stokes Flows","volume":"75","year":"2007","journal-title":"Phys. Rev. E"},{"issue":"2","key":"2019100315032520200_B45","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1007\/BF02648048","article-title":"Fluid Mechanics of Arterial Stenosis: Relationship to the Development of Mural Thrombus","volume":"25","year":"1997","journal-title":"Ann. Biomed. Eng."},{"key":"2019100315032520200_B46","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1098\/rspa.1922.0078","article-title":"The Motion of Ellipsoidal Particles Immersed in a Viscous Fluid","volume":"102","year":"1922","journal-title":"Proc. R. Soc. Lond. Ser. A"},{"key":"2019100315032520200_B47","first-page":"164","article-title":"Numerical Simulation of Cellular Blood Flow","volume-title":"Mechanical Engineering","year":"2011"},{"key":"2019100315032520200_B48","volume-title":"Human Physiology","year":"2006","edition":"9th ed."},{"key":"2019100315032520200_B49","article-title":"Disk Point Picking"},{"issue":"5","key":"2019100315032520200_B50","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1007\/BF02367081","article-title":"Whitaker Lecture: Biorheology in Thrombosis Research","volume":"22","year":"1994","journal-title":"Ann. Biomed. Eng."},{"issue":"2","key":"2019100315032520200_B51","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/0021-9290(79)90150-7","article-title":"Shear-Induced Activation of Platelets","volume":"12","year":"1979","journal-title":"J. Biomech."},{"issue":"4","key":"2019100315032520200_B52","doi-asserted-by":"crossref","first-page":"1442","DOI":"10.1007\/s10439-010-9936-2","article-title":"High-Shear Stress Sensitizes Platelets to Subsequent Low-Shear Conditions","volume":"38","year":"2010","journal-title":"Ann. Biomed. Eng."},{"issue":"12","key":"2019100315032520200_B53","doi-asserted-by":"crossref","first-page":"2400","DOI":"10.1016\/j.jbiomech.2010.04.020","article-title":"Device Thrombogenicity Emulator (DTE)-Design Optimization Methodology for Cardiovascular Devices: A Study in Two Bileaflet MHV Designs","volume":"43","year":"2010","journal-title":"J. Biomech."},{"issue":"(1)","key":"2019100315032520200_B54","first-page":"331","article-title":"Fluid Mechanics of Heart Valves","volume":"6","year":"2004","journal-title":"Ann. Rev. Biomed. Eng."},{"issue":"5","key":"2019100315032520200_B55","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1115\/1.1614817","article-title":"Numerical Simulation of Flow in Mechanical Heart Valves: Grid Resolution and the Assumption of Flow Symmetry","volume":"125","year":"2003","journal-title":"ASME J. Biomech. Eng."}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4028105\/6090420\/bio_136_10_101009.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4028105\/6090420\/bio_136_10_101009.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,31]],"date-time":"2024-05-31T14:46:08Z","timestamp":1717166768000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/doi\/10.1115\/1.4028105\/370077\/Blood-Damage-Through-a-Bileaflet-Mechanical-Heart"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,8,12]]},"references-count":55,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2014,10,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4028105","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,8,12]]},"article-number":"101009"}}