{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T04:55:33Z","timestamp":1791262533759,"version":"4.1.0"},"reference-count":56,"publisher":"ASME International","issue":"6","content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2018,6,1]]},"abstract":"<jats:p>Percutaneous pedicle screw fixation (PPSF) is a well-known minimally invasive surgery (MIS) employed in the treatment of thoracolumbar burst fractures (TBF). However, hardware failure and loss of angular correction are common limitations caused by the poor support of the anterior column of the spine. Balloon kyphoplasty (KP) is another MIS that was successfully used in the treatment of compression fractures by augmenting the injured vertebral body with cement. To overcome the limitations of stand-alone PPSF, it was suggested to augment PPSF with KP as a surgical treatment of TBF. Yet, little is known about the biomechanical alteration occurred to the spine after performing such procedure. The objective of this study was to evaluate and compare the immediate post-operative biomechanical performance of stand-alone PPSF, stand-alone-KP, and KP-augmented PPSF procedures. Novel three-dimensional (3D) finite element (FE) models of the thoracolumbar junction that describes the fractured spine and the three investigated procedures were developed and tested under mechanical loading conditions. The spinal stiffness, stresses at the implanted hardware, and the intradiscal pressure at the upper and lower segments were measured and compared. The results showed no major differences in the measured parameters between stand-alone PPSF and KP-augmented PPSF procedures, and demonstrated that the stand-alone KP may restore the stiffness of the intact spine. Accordingly, there was no immediate post-operative biomechanical advantage in augmenting PPSF with KP when compared to stand-alone PPSF, and fatigue testing may be required to evaluate the long-term biomechanical performance of such procedures.<\/jats:p>","DOI":"10.1115\/1.4039174","type":"journal-article","created":{"date-parts":[[2018,2,1]],"date-time":"2018-02-01T12:32:59Z","timestamp":1517488379000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":34,"title":["Finite Element Study to Evaluate the Biomechanical Performance of the Spine After Augmenting Percutaneous Pedicle Screw Fixation With Kyphoplasty in the Treatment of Burst Fractures"],"prefix":"10.1115","volume":"140","author":[{"given":"Shady S.","family":"Elmasry","sequence":"first","affiliation":[{"name":"Biomechanics Research Laboratory, Department of Industrial Engineering, University of Miami, 1251 Memorial Drive, McArthur Engineering Building, #156, Coral Gables, FL 33146 e-mail:"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shihab S.","family":"Asfour","sequence":"additional","affiliation":[{"name":"Biomechanics Research Laboratory, Department of Industrial Engineering, University of Miami, 1251 Memorial Drive, McArthur Engineering Building, #268, Coral Gables, FL 33146 e-mail:"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Travascio","sequence":"additional","affiliation":[{"name":"Mem. ASME Biomechanics Research Laboratory, Department of Industrial Engineering, University of Miami, 1251 Memorial Drive, McArthur Engineering Building, #276, Coral Gables, FL 33146 e-mail:"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"33","published-online":{"date-parts":[[2018,3,21]]},"reference":[{"issue":"3","key":"2019100512030453200_bib1","doi-asserted-by":"publisher","first-page":"E9","DOI":"10.3171\/2009.7.FOCUS09121","article-title":"Minimally Invasive Spine Technology and Minimally Invasive Spine Surgery: A Historical Review","volume":"27","year":"2009","journal-title":"Neurosurg. Focus"},{"issue":"6","key":"2019100512030453200_bib2","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1016\/j.injury.2012.12.005","article-title":"Advances Made in the Treatment of Thoracolumbar Fractures: Current Trends and Future Directions","volume":"44","year":"2013","journal-title":"Injury"},{"issue":"1","key":"2019100512030453200_bib3","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.spinee.2012.10.041","article-title":"Management of Thoracolumbar Spine Fractures","volume":"14","year":"2014","journal-title":"Spine J."},{"issue":"6","key":"2019100512030453200_bib4","doi-asserted-by":"publisher","first-page":"658","DOI":"10.1097\/BRS.0b013e318166e0bb","article-title":"Minimal Invasive Short Posterior Instrumentation Plus Balloon Kyphoplasty With Calcium Phosphate for Burst and Severe Compression Lumbar Fractures","volume":"33","year":"2008","journal-title":"Spine"},{"issue":"4","key":"2019100512030453200_bib5","doi-asserted-by":"publisher","first-page":"E100","DOI":"10.1097\/BRS.0b013e3181646b07","article-title":"Direct Reduction of Thoracolumbar Burst Fractures by Means of Balloon Kyphoplasty With Calcium Phosphate and Stabilization With Pedicle-Screw Instrumentation and Fusion","volume":"33","year":"2008","journal-title":"Spine"},{"issue":"6","key":"2019100512030453200_bib6","first-page":"718","article-title":"Treatment of Thoracolumbar Burst Fractures: Short-Segment Pedicle Instrumentation Versus Kyphoplasty","volume":"79","year":"2013","journal-title":"Acta Orthop. Belg."},{"issue":"1","key":"2019100512030453200_bib7","doi-asserted-by":"publisher","first-page":"51","DOI":"10.3171\/spi.2001.95.1.0051","article-title":"Microendoscopic Posterior Cervical Laminoforaminotomy for Unilateral Radiculopathy: Results of a New Technique in 100 Cases","volume":"95","year":"2001","journal-title":"J. Neurosurg.: Spine"},{"issue":"5","key":"2019100512030453200_bib8","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1016\/j.spinee.2008.08.008","article-title":"Fluoroscopic Percutaneous Lumbar Zygapophyseal Joint Cyst Rupture: A Clinical Outcome Study","volume":"9","year":"2009","journal-title":"Spine J."},{"issue":"7","key":"2019100512030453200_bib9","doi-asserted-by":"publisher","first-page":"459","DOI":"10.1097\/BSD.0b013e318167b06b","article-title":"Minimally Invasive Multilevel Percutaneous Correction and Fusion for Adult Lumbar Degenerative Scoliosis: A Technique and Feasibility Study","volume":"21","year":"2008","journal-title":"Clinical Spine Surg."},{"issue":"2","key":"2019100512030453200_bib10","first-page":"E20","article-title":"Perioperative Results Following Lumbar Discectomy: Comparison of Minimally Invasive Discectomy and Standard Microdiscectomy","volume":"25","year":"2008","journal-title":"J. Neurosurg."},{"issue":"8","key":"2019100512030453200_bib11","first-page":"530","article-title":"Percutaneous Pedicle Screw Fixation for Neurologic Intact Thoracolumbar Burst Fractures","volume":"23","year":"2010","journal-title":"Clin. Spine Surg."},{"issue":"8","key":"2019100512030453200_bib12","doi-asserted-by":"publisher","first-page":"1281","DOI":"10.1007\/s00586-010-1444-4","article-title":"Percutaneous Kyphoplasty and Pedicle Screw Fixation for the Management of Thoraco-Lumbar Burst Fractures","volume":"19","year":"2010","journal-title":"Eur. Spine J."},{"issue":"1","key":"2019100512030453200_bib13","doi-asserted-by":"publisher","first-page":"62","DOI":"10.3171\/spi.2005.2.1.0062","article-title":"Biomechanical Comparison: Stability of Lateral-Approach Anterior Lumbar Interbody Fusion and Lateral Fixation Compared With Anterior-Approach Anterior Lumbar Interbody Fusion and Posterior Fixation in the Lower Lumbar Spine","volume":"2","year":"2005","journal-title":"J. Neurosurg.: Spine"},{"issue":"14","key":"2019100512030453200_bib14","doi-asserted-by":"publisher","first-page":"1503","DOI":"10.1097\/BRS.0b013e318067dd24","article-title":"Short-Segment Fixation of Lumbar Burst Fractures Using Pedicle Fixation at the Level of the Fracture","volume":"32","year":"2007","journal-title":"Spine"},{"issue":"8","key":"2019100512030453200_bib15","doi-asserted-by":"publisher","first-page":"1734","DOI":"10.1016\/j.spinee.2014.01.035","article-title":"Biomechanical Analysis of Four-Versus Six-Screw Constructs for Short-Segment Pedicle Screw and Rod Instrumentation of Unstable Thoracolumbar Fractures","volume":"14","year":"2014","journal-title":"Spine J."},{"issue":"14","key":"2019100512030453200_bib16","doi-asserted-by":"publisher","first-page":"1537","DOI":"10.1097\/00007632-200107150-00007","article-title":"The Biomechanics of Vertebroplasty: The Effect of Cement Volume on Mechanical Behavior","volume":"26","year":"2001","journal-title":"Spine"},{"issue":"6","key":"2019100512030453200_bib17","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1053\/crad.2000.0478","article-title":"The Strengthening Effect of Percutaneous Vertebroplasty","volume":"55","year":"2000","journal-title":"Clin. Radiol."},{"issue":"5","key":"2019100512030453200_bib18","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1016\/j.otsr.2009.06.001","article-title":"Severe Thoracolumbar Osteoporotic Burst Fractures: Treatment Combining Open Kyphoplasty and Short-Segment Fixation","volume":"95","year":"2009","journal-title":"Orthop. Traumatol.: Surg. Res."},{"issue":"14","key":"2019100512030453200_bib19","doi-asserted-by":"publisher","first-page":"1511","DOI":"10.1097\/00007632-200107150-00002","article-title":"New Technologies in Spine: Kyphoplasty and Vertebroplasty for the Treatment of Painful Osteoporotic Compression Fractures","volume":"26","year":"2001","journal-title":"Spine"},{"issue":"9668","key":"2019100512030453200_bib20","doi-asserted-by":"publisher","first-page":"1016","DOI":"10.1016\/S0140-6736(09)60010-6","article-title":"Efficacy and Safety of Balloon Kyphoplasty Compared With Non-Surgical Care for Vertebral Compression Fracture (FREE): A Randomised Controlled Trial","volume":"373","year":"2009","journal-title":"Lancet"},{"issue":"3","key":"2019100512030453200_bib21","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3171\/foc.2005.18.3.10","article-title":"Kyphoplasty-Augmented Short-Segment Pedicle Screw Fixation of Traumatic Lumbar Burst Fractures: Initial Clinical Experience and Literature Review","volume":"18","year":"2005","journal-title":"Neurol. Focus"},{"issue":"3","key":"2019100512030453200_bib22","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1007\/s00586-008-0587-z","article-title":"Short Segment Pedicle Screw Instrumentation and Augmentation Vertebroplasty in Lumbar Burst Fractures: An Experience","volume":"17","year":"2008","journal-title":"Eur. Spine J."},{"key":"2019100512030453200_bib23","article-title":"The Visible Human Project: A Resource for education","volume-title":"Acad Med."},{"issue":"1","key":"2019100512030453200_bib24","first-page":"1","article-title":"Implications of Spine Fixation on the Adjacent Lumbar Levels for Surgical Treatment of Thoracolumbar Burst Fractures: A Finite Element Analysis","volume":"1","year":"2016","journal-title":"J. Spine Care"},{"key":"2019100512030453200_bib25","volume-title":"Bone Mechanics Handbook","year":"2001"},{"issue":"10","key":"2019100512030453200_bib26","first-page":"2","article-title":"Implications of Decompressive Surgical Procedures for Lumbar Spine Stenosis on the Biomechanics of the Adjacent Segment: A Finite Element Analysis","volume":"4","year":"2015","journal-title":"J. Spine"},{"issue":"4","key":"2019100512030453200_bib27","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1016\/j.clinbiomech.2005.12.001","article-title":"Application of a New Calibration Method for a Three-Dimensional Finite Element Model of a Human Lumbar Annulus Fibrosus","volume":"21","year":"2006","journal-title":"Clin. Biomech."},{"issue":"9","key":"2019100512030453200_bib28","doi-asserted-by":"publisher","first-page":"914","DOI":"10.1097\/00007632-198611000-00012","article-title":"Mechanical Response of a Lumbar Motion Segment in Axial Torque Alone and Combined With Compression","volume":"11","year":"1986","journal-title":"Spine"},{"key":"2019100512030453200_bib29","doi-asserted-by":"publisher","first-page":"S73","DOI":"10.1016\/S0268-0033(00)00108-X","article-title":"Estimation of Muscle Forces in the Lumbar Spine During Upper-Body Inclination","volume":"16","year":"2001","journal-title":"Clin. Biomech."},{"issue":"4","key":"2019100512030453200_bib30","doi-asserted-by":"publisher","first-page":"996","DOI":"10.1172\/JCI118884","article-title":"The Human Lumbar Intervertebral Disc: Evidence for Changes in the Biosynthesis and Denaturation of the Extracellular Matrix With Growth, Maturation, Ageing, and Degeneration","volume":"98","year":"1996","journal-title":"J. Clin. Invest."},{"issue":"6","key":"2019100512030453200_bib31","doi-asserted-by":"publisher","first-page":"535","DOI":"10.1016\/S0021-9290(98)00046-3","article-title":"Degeneration Affects the Anisotropic and Nonlinear Behaviors of Human Anulus Fibrosus in Compression","volume":"31","year":"1998","journal-title":"J. Biomech."},{"issue":"16","key":"2019100512030453200_bib32","doi-asserted-by":"publisher","first-page":"2769","DOI":"10.1016\/j.jbiomech.2012.08.044","article-title":"Cell Viability in Intervertebral Disc Under Various Nutritional and Dynamic Loading Conditions: 3D Finite Element Analysis","volume":"45","year":"2012","journal-title":"J. Biomech."},{"issue":"S5","key":"2019100512030453200_bib33","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1007\/s00586-010-1382-1","article-title":"Effect of Multilevel Lumbar Disc Arthroplasty on Spine Kinematics and Facet Joint Loads in Flexion and Extension: A Finite Element Analysis","volume":"21","year":"2012","journal-title":"Eur. Spine J."},{"issue":"11","key":"2019100512030453200_bib34","doi-asserted-by":"publisher","first-page":"1351","DOI":"10.1016\/0021-9290(92)90290-H","article-title":"Biomechanical Properties of Human Lumbar Spine Ligaments","volume":"25","year":"1992","journal-title":"J. Biomech."},{"issue":"2","key":"2019100512030453200_bib35","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1097\/00007632-199701150-00004","article-title":"Load Sharing Between the Shell and Centrum in the Lumbar Vertebral Body","volume":"22","year":"1997","journal-title":"Spine"},{"issue":"18","key":"2019100512030453200_bib36","doi-asserted-by":"publisher","first-page":"1873","DOI":"10.1097\/00007632-199909150-00003","article-title":"The Influence of Lumbar Disc Height and Cross-Sectional Area on the Mechanical Response of the Disc to Physiologic Loading","volume":"24","year":"1999","journal-title":"Spine"},{"issue":"11","key":"2019100512030453200_bib37","doi-asserted-by":"publisher","first-page":"2164","DOI":"10.1016\/j.jbiomech.2004.10.002","article-title":"Confined Compression Experiments on Bovine Nucleus Pulposus and Annulus Fibrosus: Sensitivity of the Experiment in the Determination of Compressive Modulus and Hydraulic Permeability","volume":"38","year":"2005","journal-title":"J. Biomech."},{"issue":"2","key":"2019100512030453200_bib38","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1002\/(SICI)1097-4636(199722)38:2<155::AID-JBM10>3.0.CO;2-C","article-title":"Properties of Acrylic Bone Cement: State of the Art Review","volume":"38","year":"1997","journal-title":"J. Biomed. Mater. Res. Part A"},{"issue":"1","key":"2019100512030453200_bib39","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1097\/01.bsd.0000138694.56012.ce","article-title":"The Biomechanical Effects of Kyphoplasty on Treated and Adjacent Nontreated Vertebral Bodies","volume":"18","year":"2005","journal-title":"J. Spinal Disord. Tech."},{"issue":"23","key":"2019100512030453200_bib40","doi-asserted-by":"publisher","first-page":"2558","DOI":"10.1097\/BRS.0b013e318158cdd8","article-title":"Finite Element Analysis of Anterior Lumbar Interbody Fusion: Threaded Cylindrical Cage and Pedicle Screw Fixation","volume":"32","year":"2007","journal-title":"Spine"},{"key":"2019100512030453200_bib41","doi-asserted-by":"publisher","DOI":"10.1080\/10255842.2017.1366995","article-title":"Effectiveness of Pedicle Screw Inclusion at the Fracture Level in Short-Segment Fixation Constructs for the Treatment of Thoracolumbar Burst Fractures: A Computational Biomechanics Analysis","volume":"20","year":"2017","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"issue":"2","key":"2019100512030453200_bib42","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1097\/00007632-200101150-00017","article-title":"Short-Segment Pedicle Instrumentation of Thoracolumbar Burst Fractures: Does Transpedicular Intracorporeal Grafting Prevent Early Failure?","volume":"26","year":"2001","journal-title":"Spine"},{"issue":"6","key":"2019100512030453200_bib43","doi-asserted-by":"publisher","first-page":"977","DOI":"10.3171\/jns.1995.83.6.0977","article-title":"Surgical Approaches for the Correction of Unstable Thoracolumbar Burst Fractures: A Retrospective Analysis of Treatment Outcomes","volume":"83","year":"1995","journal-title":"J. Neurosurg."},{"issue":"3","key":"2019100512030453200_bib44","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1080\/10255842.2010.522183","article-title":"Mechanical Variables Affecting Balloon Kyphoplasty Outcome-A Finite Element Study","volume":"15","year":"2012","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"issue":"26","key":"2019100512030453200_bib45","doi-asserted-by":"publisher","first-page":"E992","DOI":"10.1097\/01.brs.0000250177.84168.ba","article-title":"Biomechanical Rationale for Using Polyetheretherketone (PEEK) Spacers for Lumbar Interbody Fusion\u2013A Finite Element Study","volume":"31","year":"2006","journal-title":"Spine"},{"issue":"1","key":"2019100512030453200_bib46","doi-asserted-by":"publisher","first-page":"011005","DOI":"10.1115\/1.4005694","article-title":"FEBio: Finite Elements for Biomechanics","volume":"134","year":"2012","journal-title":"ASME J. Biomech. Eng."},{"key":"2019100512030453200_bib47","first-page":"416","article-title":"Long-Term Follow-Up Results of Short-Segment Posterior Screw Fixation for Thoracolumbar Burst Fractures","volume":"37","year":"2005","journal-title":"J. Korean Neurosurg. Soc."},{"issue":"5","key":"2019100512030453200_bib48","doi-asserted-by":"publisher","first-page":"527","DOI":"10.1016\/j.otsr.2011.03.020","article-title":"Percutaneous Management of Thoracolumbar Burst Fractures: Evolution of Techniques and Strategy","volume":"97","year":"2011","journal-title":"Orthop. Traumatol.: Surg. Res."},{"issue":"5","key":"2019100512030453200_bib49","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1007\/s00586-006-0258-x","article-title":"Prospective Study of Standalone Balloon Kyphoplasty With Calcium Phosphate Cement Augmentation in Traumatic Fractures","volume":"16","year":"2007","journal-title":"Eur. Spine J."},{"issue":"10","key":"2019100512030453200_bib50","doi-asserted-by":"publisher","first-page":"952","DOI":"10.1007\/s00113-002-0495-3","article-title":"Extended Kyphoplasty Indications for Stabilization of Osteoporotic Vertebral Compression Fractures","volume":"105","year":"2002","journal-title":"Der Unfallchirurg"},{"issue":"4","key":"2019100512030453200_bib51","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1016\/j.otsr.2011.02.009","article-title":"Percutaneous Internal Fixation Combined With Kyphoplasty for Neurologically Intact Thoracolumbar Fractures: A Prospective Cohort Study of 24 Patients With One Year of Follow-Up","volume":"97","year":"2011","journal-title":"Orthop. Traumatol.: Surg. Res."},{"issue":"5","key":"2019100512030453200_bib52","doi-asserted-by":"publisher","first-page":"578","DOI":"10.1097\/00007632-199403000-00014","article-title":"Thoracolumbar Burst Fracture: A Biomechanical Investigation of Its Multidirectional Flexibility","volume":"19","year":"1994","journal-title":"Spine"},{"issue":"6","key":"2019100512030453200_bib53","doi-asserted-by":"publisher","first-page":"893","DOI":"10.1007\/s00586-010-1281-5","article-title":"Kyphoplasty for the Treatment of Incomplete Osteoporotic Burst Fractures","volume":"19","year":"2010","journal-title":"Eur. Spine J."},{"issue":"4","key":"2019100512030453200_bib54","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1007\/s00586-002-0512-9","article-title":"Load Shift of the Intervertebral Disc After A Vertebroplasty: A Finite-Element Study","volume":"12","year":"2003","journal-title":"Eur. Spine J."},{"key":"2019100512030453200_bib55","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1016\/j.phpro.2014.08.120","article-title":"Effects of Defects in Laser Additive Manufactured Ti-6Al-4V on Fatigue Properties","volume":"56","journal-title":"Phys. Procedia"},{"issue":"3","key":"2019100512030453200_bib56","doi-asserted-by":"publisher","first-page":"413","DOI":"10.2106\/00004623-199403000-00012","article-title":"Mechanical Behavior of the Human Lumbar and Lumbosacral Spine as Shown by Three-Dimensional Load-Displacement Curves","volume":"76","year":"1994","journal-title":"J. Bone Jt. Surg."}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4039174\/6096794\/bio_140_06_061005.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4039174\/6096794\/bio_140_06_061005.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,5]],"date-time":"2019-10-05T12:03:13Z","timestamp":1570276993000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/doi\/10.1115\/1.4039174\/422036\/Finite-Element-Study-to-Evaluate-the-Biomechanical"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,3,21]]},"references-count":56,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2018,6,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4039174","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,3,21]]},"article-number":"061005"}}