{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,26]],"date-time":"2026-02-26T05:10:06Z","timestamp":1772082606981,"version":"3.50.1"},"reference-count":35,"publisher":"ASME International","issue":"5","content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2018,5,1]]},"abstract":"<jats:p>One particular complexity of coronary artery is the natural tapering of the vessel with proximal segments having larger caliber and distal tapering as the vessel get smaller. The natural tapering of a coronary artery often leads to proximal incomplete stent apposition (ISA). ISA alters coronary hemodynamics and creates pathological path to develop complications such as in-stent restenosis, and more worryingly, stent thrombosis (ST). By employing state-of-the-art computer-aided design software, generic stent hoops were virtually deployed in an idealized tapered coronary artery with decreasing malapposition distance. Pulsatile blood flow simulations were carried out using computational fluid dynamics (CFD) on these computer-aided design models. CFD results reveal unprecedented details in both spatial and temporal development of microrecirculation environments throughout the cardiac cycle (CC). Arterial tapering also introduces secondary microrecirculation. These primary and secondary microrecirculations provoke significant fluctuations in arterial wall shear stress (WSS). There has been a direct correlation with changes in WSS and the development of atherosclerosis. Further, the presence of these microrecirculations influence strongly on the local levels of blood viscosity in the vicinity of the malapposed stent struts. The observation of secondary microrecirculations and changes in blood rheology is believed to complement the wall (-based) shear stress, perhaps providing additional physical explanations for tissue accumulation near ISA detected from high resolution optical coherence tomography (OCT).<\/jats:p>","DOI":"10.1115\/1.4039306","type":"journal-article","created":{"date-parts":[[2018,2,14]],"date-time":"2018-02-14T15:06:28Z","timestamp":1518620788000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":18,"title":["Elevated Blood Viscosity and Microrecirculation Resulting From Coronary Stent Malapposition"],"prefix":"10.1115","volume":"140","author":[{"given":"Eric K. W.","family":"Poon","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne 3010, Victoria, Australia e-mail:"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vikas","family":"Thondapu","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne 3010, Victoria, Australia;"},{"name":"Faculty of Medicine, Dentistry, and Health Sciences, Department of Medicine, The University of Melbourne, Melbourne 3010, Victoria, Australia e-mail:"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Umair","family":"Hayat","sequence":"additional","affiliation":[{"name":"Faculty of Medicine, Dentistry and Health Sciences, Department of Medicine, The University of Melbourne, Melbourne 3010, Victoria, Australia e-mail:"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Barlis","sequence":"additional","affiliation":[{"name":"Department of Medicine, Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Melbourne 3010, Victoria, Australia e-mail:"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chooi Yin","family":"Yap","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne 3010, Victoria, Australia e-mail:"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Po-Hung","family":"Kuo","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne 3010, Victoria, Australia e-mail:"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qisen","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne 3010, Victoria, Australia e-mail:"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiawei","family":"Ma","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne 3010, Victoria, Australia e-mail:"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shuang J.","family":"Zhu","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne 3010, Victoria, Australia e-mail:"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephen","family":"Moore","sequence":"additional","affiliation":[{"name":"IBM Research Australia, Carlton 3053, Victoria, Australia e-mail:"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew S. H.","family":"Ooi","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne 3010, Victoria, Australia e-mail:"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"33","published-online":{"date-parts":[[2018,3,5]]},"reference":[{"issue":"21","key":"2019100512554896500_bib1","doi-asserted-by":"publisher","first-page":"2004","DOI":"10.1056\/NEJMra1216063","article-title":"Mechanisms of Acute Coronary Syndromes and Their Implications for Therapy","volume":"368","year":"2013","journal-title":"N. Engl. J. Med."},{"issue":"9","key":"2019100512554896500_bib2","doi-asserted-by":"publisher","first-page":"1110","DOI":"10.1161\/CIRCULATIONAHA.111.058560","article-title":"Very Late Coronary Stent Thrombosis of a Newer-Generation Eerolimus-Eluting Stent Compared With Early-Generation Drug-Eluting Stents: A Prospective Cohort Study","volume":"125","year":"2012","journal-title":"Circulation"},{"issue":"18","key":"2019100512554896500_bib3","doi-asserted-by":"publisher","first-page":"2426","DOI":"10.1161\/CIRCULATIONAHA.106.658237","article-title":"Incomplete Stent Apposition and Very Late Stent Thrombosis After Drug-Eluting Stent Implantation","volume":"115","year":"2007","journal-title":"Circulation"},{"issue":"2","key":"2019100512554896500_bib4","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1161\/CIRCINTERVENTIONS.113.000931","article-title":"Incomplete Stent Apposition Causes High Shear Flow Disturbances and Delay in Neointimal Coverage as a Function of Strut to Wall Detachment Distance: Implications for the Management of Incomplete Stent Apposition","volume":"7","year":"2014","journal-title":"Circ. Cardiovasc. Interventions"},{"issue":"1","key":"2019100512554896500_bib5","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1038\/labinvest.3700215","article-title":"The Role of Shear Stress in the Pathogenesis of Atherosclerosis","volume":"85","year":"2005","journal-title":"Lab. Invest."},{"issue":"2","key":"2019100512554896500_bib6","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1093\/eurheartj\/ehv689","article-title":"Biomechanical Stress in Coronary Atherosclerosis: Emerging Insights From Computational Modelling","volume":"38","year":"2017","journal-title":"Eur. Heart J."},{"issue":"2","key":"2019100512554896500_bib7","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1007\/s10237-015-0692-y","article-title":"Effects of Aortic Irregularities on Blood Flow","volume":"15","year":"2016","journal-title":"Biomech. Model. Mechanobiol."},{"issue":"2","key":"2019100512554896500_bib8","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1007\/s10237-012-0449-9","article-title":"Hematocrit, Viscosity and Velocity Distributions of Aggregating and Non-Aggregating Blood in a Bifurcating Microchannel","volume":"13","year":"2014","journal-title":"Biomech. Model. Mechanobiol."},{"issue":"3","key":"2019100512554896500_bib9","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1016\/0026-2862(77)90098-X","article-title":"Determination of Aggregation Force in Rouleaux by Fluid Mechanical Technique","volume":"13","year":"1977","journal-title":"Microvasc. Res."},{"issue":"6","key":"2019100512554896500_bib10","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1007\/BF01522037","article-title":"Rheology of Concentrated Disperse Systems\u2014Part III: General Features of the Proposed Non-Newtonian Model. Comparison With Experimental Data","volume":"17","year":"1978","journal-title":"Rheol. Acta"},{"issue":"13","key":"2019100512554896500_bib11","doi-asserted-by":"publisher","first-page":"1400","DOI":"10.1161\/CIRCULATIONAHA.110.003210","article-title":"Stent Thrombogenicity Early in High-Risk Interventional Settings is Driven by Stent Design and Deployment and Protected by Polymer-Drug Coatings","volume":"123","year":"2011","journal-title":"Circulation"},{"issue":"15","key":"2019100512554896500_bib12","doi-asserted-by":"publisher","first-page":"2970","DOI":"10.1016\/j.jbiomech.2010.07.011","article-title":"Wall Shear Over High Degree Stenoses Pertinent to Atherothrombosis","volume":"43","year":"2010","journal-title":"J. Biomech."},{"key":"2019100512554896500_bib13","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1016\/j.jbiomech.2017.09.016","article-title":"Haemodynamic Effects of Incomplete Stent Apposition in Curved Coronary Arteries","volume":"63","year":"2017","journal-title":"J. Biomech."},{"issue":"7","key":"2019100512554896500_bib14","doi-asserted-by":"publisher","first-page":"71901","DOI":"10.1063\/1.4923311","article-title":"Non-Newtonian Perspectives on Pulsatile Blood-Analog Flows in a 180\u2009\u00b0 Curved Artery Model","volume":"27","year":"2015","journal-title":"Phys. Fluids"},{"issue":"4","key":"2019100512554896500_bib15","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1007\/BF00435088","article-title":"An Analytical Solution for Steady Flow of a Quemada Fluid in a Circular Tube","volume":"32","year":"1993","journal-title":"Rheol. Acta"},{"issue":"4","key":"2019100512554896500_bib16","doi-asserted-by":"publisher","first-page":"459","DOI":"10.1002\/(SICI)1097-0363(19980228)26:4<459::AID-FLD645>3.0.CO;2-U","article-title":"Comparison of SIMPLE- and PISO-Type Algorithms for Transient Flows","volume":"26","year":"1998","journal-title":"Int. J. Numer. Methods Fluids"},{"issue":"12","key":"2019100512554896500_bib17","doi-asserted-by":"publisher","first-page":"2843","DOI":"10.1016\/j.jbiomech.2014.07.030","article-title":"Numerical Investigations of the Haemodynamic Changes Associated With Stent Malapposition in an Idealised Coronary Artery","volume":"47","year":"2014","journal-title":"J. Biomech."},{"key":"2019100512554896500_bib18","doi-asserted-by":"publisher","first-page":"S258","DOI":"10.1016\/j.hlc.2015.06.345","article-title":"A Randomised Controlled Trial of Biolimus-Eluting and Everolimus-Eluting Stents: An Optical Coherence Tomography (OCT) Study","volume":"24","year":"2015","journal-title":"Heart Lung Circ."},{"issue":"6","key":"2019100512554896500_bib19","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1080\/10255842.2017.1289374","article-title":"Computational Fluid Dynamics Study of Common Stent Models Inside Idealised Curved Coronary Arteries","volume":"20","year":"2017","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"issue":"2","key":"2019100512554896500_bib20","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1007\/s10439-015-1387-3","article-title":"Hemodynamics in Idealized Stented Coronary Arteries: Important Stent Design Considerations","volume":"44","year":"2016","journal-title":"Ann. Biomed. Eng."},{"issue":"Pt. 2","key":"2019100512554896500_bib21","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1007\/978-3-319-10470-6_64","article-title":"Construction of a Coronary Artery Atlas From CT Angiography","volume":"17","year":"2014","journal-title":"Med. Image Comput. Comput. Assist. Intervention"},{"issue":"12","key":"2019100512554896500_bib22","doi-asserted-by":"publisher","first-page":"1545","DOI":"10.1136\/hrt.2008.144808","article-title":"What is the Role of the Aorta in Directing Coronary Blood Flow?","volume":"94","year":"2008","journal-title":"Heart"},{"issue":"20","key":"2019100512554896500_bib23","doi-asserted-by":"publisher","first-page":"2167","DOI":"10.1016\/j.jcin.2016.08.019","article-title":"The Nidus for Possible Thrombus Formation","volume":"9","year":"2016","journal-title":"JACC Cardiovasc. Intervention"},{"issue":"4","key":"2019100512554896500_bib24","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1114\/1.276","article-title":"Experimental and Computational Flow Evaluation of Coronary Stents","volume":"28","year":"2000","journal-title":"Ann. Biomed. Eng."},{"issue":"5","key":"2019100512554896500_bib25","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1016\/j.jbiomech.2003.09.016","article-title":"Non-Newtonian Blood Flow in Human Right Coronary Arteries: Steady State Simulations","volume":"37","year":"2004","journal-title":"J. Biomech."},{"issue":"1","key":"2019100512554896500_bib26","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1111\/j.1753-4887.1989.tb02747.x","article-title":"As Based Upon Physiological and Pathological Histology","volume":"47","year":"1989","journal-title":"Nutr. Rev."},{"issue":"21","key":"2019100512554896500_bib27","doi-asserted-by":"publisher","first-page":"2035","DOI":"10.1001\/jama.282.21.2035","article-title":"Hemodynamic Shear Stress and Its Role in Atherosclerosis","volume":"282","year":"1999","journal-title":"J. Am. Med. Assoc."},{"issue":"5","key":"2019100512554896500_bib28","doi-asserted-by":"publisher","first-page":"535","DOI":"10.4244\/EIJV10I5A94","article-title":"Assessment of Lesion Functional Significance With Virtual FFR\u2014Are We Going With the Flow?","volume":"10","year":"2014","journal-title":"EuroIntervention"},{"key":"2019100512554896500_bib29","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehx810","article-title":"Endothelial Shear Stress 5 Years After Implantation of a Coronary Bioresorbable Scaffold","year":"2018","journal-title":"Eur. Heart J."},{"issue":"4","key":"2019100512554896500_bib30","doi-asserted-by":"publisher","first-page":"646","DOI":"10.1161\/01.ATV.17.4.646","article-title":"Shear-Induced Platelet Activation and Platelet Microparticle Formation at Blood Flow Conditions as in Arteries With a Severe Stenosis","volume":"17","year":"1997","journal-title":"Arterioscler. Thromb. Vasc. Biol."},{"issue":"14","key":"2019100512554896500_bib31","doi-asserted-by":"publisher","first-page":"1768","DOI":"10.1161\/CIRCULATIONAHA.105.603050","article-title":"Evidence of a Dominant Backward-Propagating \u2018Suction\u2019 Wave Responsible for Diastolic Coronary Filling in Humans, Attenuated in Left Ventricular Hypertrophy","volume":"113","year":"2006","journal-title":"Circulation"},{"issue":"3","key":"2019100512554896500_bib32","doi-asserted-by":"publisher","first-page":"553","DOI":"10.1113\/jphysiol.1955.sp005276","article-title":"Method for the Calculation of Velocity, Rate of Flow and Viscous Drag in Arteries When the Pressure Gradient is Known","volume":"127","year":"1955","journal-title":"J. Physiol."},{"issue":"2","key":"2019100512554896500_bib33","doi-asserted-by":"publisher","first-page":"448","DOI":"10.1161\/01.RES.67.2.448","article-title":"An In Vivo Study of the Onset of Turbulence in the Sinus of Valsalva","volume":"67","year":"1990","journal-title":"Circ. Res."},{"issue":"Suppl. 1","key":"2019100512554896500_bib34","doi-asserted-by":"publisher","first-page":"S6","DOI":"10.1186\/1475-925X-14-S1-S6","article-title":"Influence of Model Boundary Conditions on Blood Flow Patterns in a Patient Specific Stenotic Right Coronary Artery","volume":"14","year":"2015","journal-title":"Biomed. Eng. Online"},{"issue":"2","key":"2019100512554896500_bib35","doi-asserted-by":"publisher","first-page":"449","DOI":"10.2298\/TSCI130227161A","article-title":"Numerical Study of the Non-Newtonian Blood Flow in a Stenosed Artery Using Two Rheological Models","volume":"20","year":"2016","journal-title":"Therm. Sci."}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4039306\/6096943\/bio_140_05_051006.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4039306\/6096943\/bio_140_05_051006.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,5]],"date-time":"2019-10-05T16:55:52Z","timestamp":1570294552000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/doi\/10.1115\/1.4039306\/422069\/Elevated-Blood-Viscosity-and-Microrecirculation"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,3,5]]},"references-count":35,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2018,5,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4039306","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,3,5]]},"article-number":"051006"}}