{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T10:49:07Z","timestamp":1789728547602,"version":"4.0.1"},"reference-count":26,"publisher":"ASME International","issue":"7","content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2018,7,1]]},"abstract":"<jats:p>Recent designs of ankle-foot orthoses (AFOs) have been influenced by the increasing demand for higher function from active individuals. The biomechanical function of the individual and device is dependent upon the underlying mechanical characteristics of the AFO. Prior mechanical testing of AFOs has primarily focused on rotational stiffness to provide insight into expected functional outcomes; mechanical characteristics pertaining to energy storage and release have not yet been investigated. A pseudostatic bench testing method is introduced to characterize compressive stiffness, device deflection, and motion of solid-ankle, anterior floor reaction, posterior leaf spring, and the intrepid dynamic exoskeletal orthosis (IDEO) AFOs. Each of these four AFOs, donned over a surrogate limb, were compressively loaded at different joint angles to simulate the foot-shank orientation during various subphases of stance. In addition to force\u2013displacement measurements, deflection of each AFO strut and rotation of proximal and supramalleolar segments were analyzed. Although similar compressive stiffness values were observed for AFOs designed to reduce ankle motion, the corresponding strut deflection profile differed based on the respective fabrication material. For example, strut deflection of carbon-fiber AFOs resembled column buckling. Expanded clinical test protocols to include quantification of AFO deflection and rotation during subject use may provide additional insight into design and material effects on performance and functional outcomes, such as energy storage and release.<\/jats:p>","DOI":"10.1115\/1.4039816","type":"journal-article","created":{"date-parts":[[2018,5,1]],"date-time":"2018-05-01T07:30:52Z","timestamp":1525159852000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":12,"title":["Assessment of Mechanical Characteristics of Ankle-Foot Orthoses"],"prefix":"10.1115","volume":"140","author":[{"given":"Amanda","family":"Wach","sequence":"first","affiliation":[{"name":"Department of Biomedical Engineering, Marquette University, Olin Engineering Center, Room 206, 1515 W. Wisconsin Avenue, Milwaukee, WI 53233 e-mail:"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Linda","family":"McGrady","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Medical College of Wisconsin, Milwaukee, WI 53226"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mei","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Medical College of Wisconsin, Milwaukee, WI 53226"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Barbara","family":"Silver-Thorn","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Marquette University, Milwaukee, WI 53233"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"33","published-online":{"date-parts":[[2018,4,30]]},"reference":[{"issue":"12","key":"2019100316191931700_bib1","doi-asserted-by":"publisher","first-page":"2643","DOI":"10.2106\/JBJS.G.01326","article-title":"Short-Term Outcomes of Severe Open Wartime Tibial Fractures Treated With Ring External Fixation","volume":"90","year":"2008","journal-title":"J. Bone Jt. Surg., Am."},{"issue":"1","key":"2019100316191931700_bib2","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/j.fcl.2009.11.005","article-title":"The Mangled Foot and Leg: Salvage Versus Amputation","volume":"15","year":"2010","journal-title":"Foot Ankle Clin."},{"issue":"1","key":"2019100316191931700_bib3","first-page":"8","article-title":"Can an Ankle-Foot Orthosis Change Hearts and Minds?","volume":"20","year":"2011","journal-title":"J. Surg. Orthop. Adv."},{"key":"2019100316191931700_bib4","volume-title":"Biomechanical Basis of Orthotic Management","year":"1993"},{"key":"2019100316191931700_bib5","first-page":"181","article-title":"Orthoses in Rehabilitation","volume-title":"Orthotics and Prosthetics in Rehabilitation: A Multidisciplinary Approach","year":"2013"},{"issue":"4","key":"2019100316191931700_bib6","doi-asserted-by":"publisher","first-page":"652","DOI":"10.1016\/j.gaitpost.2006.07.013","article-title":"A New Carbon Fibre Spring Orthosis for Children With Plantarflexor Weakness","volume":"25","year":"2007","journal-title":"Gait Posture"},{"issue":"4","key":"2019100316191931700_bib7","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1080\/16501970410025126","article-title":"Energy Expenditure in Stroke Subjects Walking With a Carbon Composite Ankle Foot Orthosis","volume":"36","year":"2004","journal-title":"J. Rehabil. Med."},{"issue":"6","key":"2019100316191931700_bib8","doi-asserted-by":"publisher","first-page":"507","DOI":"10.2106\/JBJS.K.00254","article-title":"Comparative Effect of Orthosis Design on Functional Performance","volume":"94","year":"2012","journal-title":"J. Bone Jt. Surg., Am."},{"issue":"Suppl","key":"2019100316191931700_bib9","doi-asserted-by":"publisher","first-page":"S120","DOI":"10.1097\/TA.0b013e3182219225","article-title":"Return to Running and Sports Participation After Limb Salvage","volume":"71","year":"2011","journal-title":"J. Trauma: Inj., Infect., Crit. Care"},{"issue":"1","key":"2019100316191931700_bib10","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/j.gaitpost.2007.11.012","article-title":"Dynamic Assist by Carbon Fiber Spring AFOs for Patients With Myelomeningocele","volume":"28","year":"2008","journal-title":"Gait Posture"},{"issue":"10","key":"2019100316191931700_bib11","doi-asserted-by":"publisher","first-page":"1125","DOI":"10.1016\/j.clinbiomech.2015.08.014","article-title":"Biomechanical Response to Ankle-Foot Orthosis Stiffness During Running","volume":"30","year":"2015","journal-title":"Clin. Biomech."},{"key":"2019100316191931700_bib12","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/j.gaitpost.2017.04.023","article-title":"Ankle-Foot Orthosis Bending Axis Influences Running Mechanics","volume":"56","year":"2017","journal-title":"Gait Posture"},{"issue":"3","key":"2019100316191931700_bib13","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1080\/03093640903055254","article-title":"A New Ankle Foot Orthosis for Running","volume":"33","year":"2009","journal-title":"Prosthet. Orthot. Int."},{"issue":"7","key":"2019100316191931700_bib14","doi-asserted-by":"publisher","first-page":"e870","DOI":"10.7205\/MILMED-D-13-00002","article-title":"Long-Term Outcomes of a Dynamic Ankle-Foot Orthosis on Gait Characteristics of a Service Member With Incomplete Nerve Injury to the Lower Extremity: A Case Report","volume":"178","year":"2013","journal-title":"Mil. Med."},{"issue":"3","key":"2019100316191931700_bib15","doi-asserted-by":"publisher","first-page":"293","DOI":"10.3109\/03093646.2010.495969","article-title":"Polypropylene Ankle Foot Orthoses to Overcome Drop-Foot Gait in Central Neurological Patients: A Mechanical and Functional Evaluation","volume":"34","year":"2010","journal-title":"Prosthet. Orthot. Int."},{"issue":"5","key":"2019100316191931700_bib16","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1682\/JRRD.2010.10.0193","article-title":"Techniques to Measure Rigidity of Ankle-Foot Orthosis: A Review","volume":"48","year":"2011","journal-title":"J. Rehabil. Res. Dev."},{"key":"2019100316191931700_bib17","unstructured":"Hawkins, M. C., 2010, \u201cExperimental and Computational Analysis of an Energy Storage Composite Ankle Foot Orthosis,\u201d Doctoral thesis, University of Nevada, Las Vegas, NV.https:\/\/digitalscholarship.unlv.edu\/thesesdissertations\/728\/"},{"issue":"1","key":"2019100316191931700_bib18","first-page":"52","article-title":"Analysis of a Vertical Compliance Prosthetic Foot","volume":"34","year":"1997","journal-title":"J. Rehabil. Res. Dev."},{"key":"2019100316191931700_bib19","unstructured":"Wach, A., 2015, \u201cMechanical Characterization of Carbon Fiber and Thermoplastic Ankle Foot Orthoses,\u201d Master's thesis, Marquette University, Milwaukee, WI.https:\/\/epublications.marquette.edu\/cgi\/viewcontent.cgi?article=1332&context=theses_open"},{"issue":"4","key":"2019100316191931700_bib20","doi-asserted-by":"publisher","first-page":"439","DOI":"10.3109\/03093646.2010.495370","article-title":"Design of an Automated Device to Measure Sagittal Plane Stiffness of an Articulated Ankle-Foot Orthosis","volume":"34","year":"2010","journal-title":"Proc. Inst. Mech. Eng.: Part H"},{"issue":"1","key":"2019100316191931700_bib21","doi-asserted-by":"publisher","first-page":"44","DOI":"10.3109\/03093640409167924","article-title":"A New Structural Concept in Moulded Fixed Ankle Foot Orthoses and Comparison of the Bending Stiffness of Four Constructions","volume":"28","year":"2004","journal-title":"Prosthet. Orthot. Int."},{"issue":"2","key":"2019100316191931700_bib22","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1016\/j.gaitpost.2009.05.012","article-title":"A New Method for Evaluating Ankle Foot Orthosis Characteristics: BRUCE","volume":"30","year":"2009","journal-title":"Gait Posture"},{"issue":"4","key":"2019100316191931700_bib23","doi-asserted-by":"publisher","first-page":"478","DOI":"10.1177\/0309364611425696","article-title":"Design of a Manual Device to Measure Ankle Joint Stiffness and Range of Motion","volume":"35","year":"2011","journal-title":"Prosthet. Orthot. Int."},{"issue":"4","key":"2019100316191931700_bib24","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1097\/JPO.0b013e31812e555e","article-title":"Quantifying the Spring-Like Properties of Ankle-Foot Orthoses (AFOs)","volume":"19","year":"2007","journal-title":"J. Prosthet. Orthot."},{"issue":"3","key":"2019100316191931700_bib25","doi-asserted-by":"publisher","DOI":"10.1097\/00008526-199901130-00002","article-title":"Design Changes in Ankle-Foot Orthosis Intended to Alter Stiffness Also Alter Orthosis Kinematics","volume":"11","year":"1999","journal-title":"J. Prosthet. Orthot."},{"issue":"2","key":"2019100316191931700_bib26","doi-asserted-by":"publisher","first-page":"116","DOI":"10.4236\/jbise.2013.62015","article-title":"How Should We Assess the Mechanical Properties of Lower-Limb Prosthesis Technology Used in Elite Sport?\u2014An Initial Investigation","volume":"6","year":"2013","journal-title":"J. Biomed. Sci. Eng."}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4039816\/6096713\/bio_140_07_071007.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4039816\/6096713\/bio_140_07_071007.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,3]],"date-time":"2019-10-03T20:19:28Z","timestamp":1570133968000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/doi\/10.1115\/1.4039816\/367283\/Assessment-of-Mechanical-Characteristics-of"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,4,30]]},"references-count":26,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2018,7,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4039816","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,4,30]]},"article-number":"071007"}}