{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T12:48:13Z","timestamp":1788353293045,"version":"build-2803163510"},"reference-count":28,"publisher":"ASME International","issue":"11","content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2018,11,1]]},"abstract":"<jats:p>Iris-fixated aphakic intraocular lenses (IFIOL) are used in cataract surgery when more common intraocular lenses (IOL) cannot be adopted because of the absence of capsular bag support. These lenses can be implanted on either the posterior or the anterior surface of the iris. In this work, we study whether one of these options is preferable over the other from the mechanical point of view. In particular, we focus on the forces that the IFIOL transmits to the iris, which are associated with the risk of lens dislocation. We study the problem numerically and consider aqueous flow induced by saccadic rotations in the cases of an IFIOL in the anterior and posterior sides of the iris. The considered IFIOL is the Artisan Aphakia +30.0 D lens (IFIOL) produced by Ophtec BV. We perform the simulations in openfoam. We find that the forces transmitted by the aphakic IFIOL to the iris are significantly higher in the case of posterior implantation. This suggests that lens implantation on the posterior surface of the iris might be associated with a higher risk of lens dislocation, when an inadequate amount of iris tissue is enclavated during implantation.<\/jats:p>","DOI":"10.1115\/1.4040588","type":"journal-article","created":{"date-parts":[[2018,7,20]],"date-time":"2018-07-20T22:30:22Z","timestamp":1532125822000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":2,"title":["A Study of the Mechanical Forces on Aphakic Iris-Fixated Intraocular Lenses"],"prefix":"10.1115","volume":"140","author":[{"given":"Peyman Davvalo","family":"Khongar","sequence":"first","affiliation":[{"name":"Department of Civil, Chemical and Environmental Engineering, University of Genoa, Genoa 16145, Italy e-mail:"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan Oscar","family":"Pralits","sequence":"additional","affiliation":[{"name":"Department of Civil, Chemical and Environmental Engineering, University of Genoa, Genoa 16145, Italy e-mail:"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paolo","family":"Soleri","sequence":"additional","affiliation":[{"name":"Ophtec BV, Groningen 9728 NR, The Netherlands e-mail:"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mario","family":"Romano","sequence":"additional","affiliation":[{"name":"Department of Biomedical Sciences, Humanitas University, Rozzano, Milano 20090, Italy e-mail:"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rodolfo","family":"Repetto","sequence":"additional","affiliation":[{"name":"Department of Civil, Chemical and Environmental Engineering, University of Genoa, Genoa 16145, Italy e-mail:"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"33","published-online":{"date-parts":[[2018,8,20]]},"reference":[{"key":"2019100604364670400_bib1","author":"WHO","year":"2012","journal-title":"Global Data on Visual Impairments 2010"},{"issue":"6","key":"2019100604364670400_bib2","doi-asserted-by":"publisher","first-page":"821","DOI":"10.1038\/eye.2012.51","article-title":"The Cataract National Dataset Electronic Multi-Centre Audit of 55 567 Operations: Risk Indicators for Monocular Visual Acuity Outcomes","volume":"26","year":"2012","journal-title":"Eye"},{"issue":"1","key":"2019100604364670400_bib3","doi-asserted-by":"publisher","first-page":"46","DOI":"10.3109\/09286586.2015.1083037","article-title":"Complications of Cataract Surgery in Iran: Trend From 2006 to 2010","volume":"23","year":"2016","journal-title":"Ophthalmic Epidemiol."},{"issue":"4","key":"2019100604364670400_bib4","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1016\/j.jcrs.2006.01.047","article-title":"Effect and Outcomes of Posterior Capsule Rupture in a District General Hospital Setting","volume":"32","year":"2006","journal-title":"J. Cataract Refractive Surg."},{"issue":"1","key":"2019100604364670400_bib5","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1186\/s12886-015-0146-4","article-title":"Long-Term Follow-Up of Retropupillary Iris-Claw Intraocular Lens Implantation: A Retrospective Analysis","volume":"15","year":"2015","journal-title":"BMC Ophthalmol."},{"issue":"12","key":"2019100604364670400_bib6","doi-asserted-by":"publisher","first-page":"2139","DOI":"10.1016\/j.jcrs.2012.07.035","article-title":"Visual Outcome and Complications After Posterior Iris-Claw Aphakic Intraocular Lens Implantation","volume":"38","year":"2012","journal-title":"J. Cataract Refractive Surg."},{"issue":"4","key":"2019100604364670400_bib7","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1007\/s00417-008-0940-2","article-title":"Implantation of Retropupillar Iris Claw Lenses With and Without Combined Penetrating Keratoplasty","volume":"247","year":"2009","journal-title":"Graefe's Arch. Clin. Exp. Ophthalmol."},{"issue":"4","key":"2019100604364670400_bib8","doi-asserted-by":"publisher","first-page":"1151","DOI":"10.1007\/s00417-012-2226-y","article-title":"Visual Outcomes and Complications Following Posterior Iris-Claw Aphakic Intraocular Lens Implantation Combined With Penetrating Keratoplasty","volume":"251","year":"2013","journal-title":"Graefe's Arch. Clin. Exp. Ophthalmol."},{"issue":"10","key":"2019100604364670400_bib9","doi-asserted-by":"publisher","first-page":"685","DOI":"10.3928\/1081597X-20130723-02","article-title":"Intraocular Lens Implantation Procedures in Aphakic Eyes With Insufficient Capsular Support Associated With Previous Cataract Surgery","volume":"29","year":"2013","journal-title":"J. Refractive Surg."},{"key":"2019100604364670400_bib10","doi-asserted-by":"publisher","first-page":"137","DOI":"10.2147\/OPTH.S55205","article-title":"Aphakia Correction With Retropupillary Fixated Iris-Claw Lens (Artisan)\u2013Long-Term Results","volume":"8","year":"2014","journal-title":"Clin. Ophthalmol."},{"issue":"9","key":"2019100604364670400_bib11","doi-asserted-by":"publisher","first-page":"1667","DOI":"10.1016\/j.jcrs.2011.03.051","article-title":"Iris-Claw Intraocular Lenses to Correct Aphakia in the Absence of Capsule Support","volume":"37","year":"2011","journal-title":"J. Cataract Refractive Surg."},{"issue":"2","key":"2019100604364670400_bib12","first-page":"118","article-title":"Iris Claw Versus Scleral Fixation Intraocular Lens Implantation During Pars Plana Vitrectomy","volume":"7","year":"2012","journal-title":"J. Ophthalmic Vision Res."},{"key":"2019100604364670400_bib13","unstructured":"Dyson, R., Fitt, A. J., Jensen, O. E., Mottram, N., Miroshnychenko, D., Naire, S., Ocone, R., Siggers, J. H., and Smithbecker, A., 2004, \u201cPost Re-Attachment Retinal Re-Detachment,\u201d Fourth Medical Study Group, University of Strathclyde, Glasgow, Scotland, pp. 1\u201330."},{"issue":"19","key":"2019100604364670400_bib14","doi-asserted-by":"publisher","first-page":"4729","DOI":"10.1088\/0031-9155\/50\/19\/021","article-title":"Experimental Investigation of Vitreous Humour Motion Within a Human Eye Model","volume":"50","year":"2005","journal-title":"Phys. Med. Biol."},{"issue":"5","key":"2019100604364670400_bib15","doi-asserted-by":"publisher","first-page":"3061","DOI":"10.1167\/iovs.14-16118","article-title":"Phakic Iris-Fixated Intraocular Lens Placement in the Anterior Chamber: Effects on Aqueous Flowphakic Iris-Fixated Intraocular Lens Placement","volume":"56","year":"2015","journal-title":"Invest. Ophthalmol. Visual Sci."},{"issue":"15","key":"2019100604364670400_bib16","doi-asserted-by":"publisher","first-page":"2454","DOI":"10.1016\/j.jbiomech.2009.07.025","article-title":"Modeling Aqueous Humor Collection From the Human Eye","volume":"42","year":"2009","journal-title":"J. Biomech."},{"issue":"1","key":"2019100604364670400_bib17","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1097\/ICU.0000000000000113","article-title":"Intraoperative Management of Posterior Capsular Rupture","volume":"26","year":"2015","journal-title":"Curr. Opin. Ophthalmol."},{"issue":"7","key":"2019100604364670400_bib18","doi-asserted-by":"publisher","first-page":"2021","DOI":"10.1088\/0031-9155\/52\/7\/016","article-title":"Eye Rotation Induced Dynamics of a Newtonian Fluid Within the Vitreous Cavity: The Effect of the Chamber Shape","volume":"52","year":"2007","journal-title":"Phys. Med. Biol."},{"issue":"1","key":"2019100604364670400_bib19","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1007\/s10237-009-0159-0","article-title":"Mathematical Model of Flow in the Vitreous Humor Induced by Saccadic Eye Rotations: Effect of Geometry","volume":"9","year":"2010","journal-title":"Biomech. Model. Mechanobiol."},{"issue":"6","key":"2019100604364670400_bib20","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1016\/j.medengphy.2011.09.011","article-title":"Numerical Simulation of the Fluid Dynamics in Vitreous Cavity Due to Saccadic Eye Movement","volume":"34","year":"2012","journal-title":"Med. Eng. Phys."},{"key":"2019100604364670400_bib21","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1016\/j.jnnfm.2013.12.001","article-title":"Numerical Simulation for Unsteady Motions of the Human Vitreous Humor as a Viscoelastic Substance in Linear and Non-Linear Regimes","volume":"204","year":"2014","journal-title":"J. Non-Newtonian Fluid Mech."},{"key":"2019100604364670400_bib22","volume-title":"The Edward S Harkness Eye Institute Resident's Basic Science Study Guide","year":"1991"},{"issue":"1","key":"2019100604364670400_bib23","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1007\/BF02363420","article-title":"Mathematical Model of the Corneo-Scleral Shell as Applied to Intraocular Pressure-Volume Relations and Applanation Tonometry","volume":"1","year":"1972","journal-title":"Ann. Biomed. Eng."},{"issue":"4","key":"2019100604364670400_bib24","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1016\/S0002-9394(14)76159-8","article-title":"Ultrasound Biomicroscopy of Anterior Segment Structures in Normal and Glaucomatous Eyes","volume":"113","year":"1992","journal-title":"Am. J. Ophthalmol."},{"key":"2019100604364670400_bib25","article-title":"Biological Effects and Exposure Limits For \u201cHot Particles","year":"1999"},{"key":"2019100604364670400_bib26","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1136\/bjo.40.9.545","article-title":"Effect of Hyaluronidase on the Viscosity of the Aqueous Humour","volume":"40","year":"1956","journal-title":"Br. J. Ophthalmol."},{"key":"2019100604364670400_bib27","article-title":"Metrics","volume-title":"The Neurobiology of Saccadic Eye Movements","author":"Wurtz","year":"1989"},{"issue":"2","key":"2019100604364670400_bib28","doi-asserted-by":"publisher","first-page":"021002","DOI":"10.1115\/1.4005762","article-title":"Investigation of Saccadic Eye Movement Effects on the Fluid Dynamic in the Anterior Chamber","volume":"134","year":"2012","journal-title":"ASME J. Biomech. Eng."}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4040588\/5991314\/bio_140_11_111009.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4040588\/5991314\/bio_140_11_111009.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,6]],"date-time":"2019-10-06T08:36:56Z","timestamp":1570351016000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/doi\/10.1115\/1.4040588\/366106\/A-Study-of-the-Mechanical-Forces-on-Aphakic"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,8,20]]},"references-count":28,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2018,11,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4040588","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,8,20]]},"article-number":"111009"}}