{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T03:27:55Z","timestamp":1761017275827,"version":"3.41.2"},"reference-count":17,"publisher":"ASME International","issue":"10","content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2019,10,1]]},"abstract":"<jats:p>As the use of glenoid suture anchors in arthroscopic and open reconstruction, for instability after Bankart lesions of the shoulder, increases, an emerging problem has been the incidence of glenoid rim fractures through suture drill holes. Very little is known regarding the effect of the Hill\u2013Sachs lesion on the glenoid's susceptibility to fracture and how drill hole location can further affect this. This study used finite element modeling techniques to investigate the risk of fracture of the glenoid rim in relation to variable sized Hill\u2013Sachs defects impacting on the anterior glenoid edge with suture anchor holes placed in varying positions. The distribution of Von Mises (VM) stresses and the factor of safety (FOS) for each of the configurations were calculated. The greatest peak in VM stresses was generated when the glenoid was loaded with a small Hill\u2013Sachs lesion. The VM stresses were lessened and the FOS increased (reducing likelihood of failure) with increasing size of the Hill\u2013Sachs lesion. Placement of the suture drill holes at 2\u2009mm from the glenoid rim showed the highest risk of failure; and when combined with a medium sized Hill\u2013Sachs lesion, which matched the central line of the drill holes, a potentially clinically significant configuration was presented. The results of this study are useful in assisting the surgeon in understanding the interaction between the Hill\u2013Sachs lesion size and the placement of suture anchors with the purpose of minimizing the risk of subsequent rim fracture with new injury.<\/jats:p>","DOI":"10.1115\/1.4043969","type":"journal-article","created":{"date-parts":[[2019,6,8]],"date-time":"2019-06-08T16:31:36Z","timestamp":1560011496000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":1,"title":["Anchor Hole Placement for Bankart Repairs and Its Interaction With Variable Size Hill\u2013Sachs Defects-Minimizing Risk of Glenoid Rim Fractures"],"prefix":"10.1115","volume":"141","author":[{"given":"Dan\u00e8","family":"Dabirrahmani","sequence":"first","affiliation":[{"name":"Faculty of Medicine and Health Sciences, Macquarie University, Sydney, NSW 2109, Australia e-mail:"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Desmond","family":"Bokor","sequence":"additional","affiliation":[{"name":"Faculty of Medicine and Health Sciences, Macquarie University, Sydney, NSW 2109, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Tarento","sequence":"additional","affiliation":[{"name":"Faculty of Medicine and Health Sciences, Macquarie University, Sydney, NSW 2109, Australia;"},{"name":"School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW 2006, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shahrulazua","family":"Ahmad","sequence":"additional","affiliation":[{"name":"Sports Injury Unit, Department of Orthopaedic and Traumatology, Universiti Kebangsaan Malaysia Medical Centre, Kuala Lumpur, Malaysia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Richard","family":"Appleyard","sequence":"additional","affiliation":[{"name":"Faculty of Medicine and Health Sciences, Macquarie University, Sydney, NSW 2109, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"33","published-online":{"date-parts":[[2019,7,11]]},"reference":[{"issue":"5","key":"2019100601382251000_bib1","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1016\/j.arthro.2008.10.027","article-title":"Glenoid Rim Fracture in Contact Athletes With Absorbable Suture Anchor Reconstruction","volume":"25","year":"2009","journal-title":"Arthroscopy"},{"issue":"8","key":"2019100601382251000_bib2","doi-asserted-by":"publisher","first-page":"1682","DOI":"10.1177\/0363546510364239","article-title":"Glenoid Rim Fracture After Anchor Repair. A Report of 4 Cases","volume":"38","year":"2010","journal-title":"Am. J. Sports Med."},{"issue":"8","key":"2019100601382251000_bib3","doi-asserted-by":"publisher","first-page":"1632","DOI":"10.1177\/0363546509336341","article-title":"Superior Glenoid Fracture Involving the Biceps Anchor: A Case Report","volume":"37","year":"2009","journal-title":"Am. J. Sports Med."},{"issue":"10","key":"2019100601382251000_bib4","doi-asserted-by":"publisher","first-page":"1061","DOI":"10.1016\/j.arthro.2009.07.003","article-title":"Cause of Glenoid Rim Fracture","volume":"25","year":"2009","journal-title":"Arthroscopy"},{"issue":"5","key":"2019100601382251000_bib5","doi-asserted-by":"publisher","first-page":"e31","DOI":"10.1016\/j.arthro.2011.03.009","article-title":"Glenoid Fracture Following Arthroscopic Bankart Repair: A Biomechanical Study (SS-06)","volume":"27","year":"2011","journal-title":"Arthroscopy"},{"issue":"6","key":"2019100601382251000_bib6","doi-asserted-by":"publisher","first-page":"809","DOI":"10.1177\/036354659702500613","article-title":"Two- to Five-Year Followup of Arthroscopic Bankart Reconstruction Using a Suture Anchor Technique","volume":"25","year":"1997","journal-title":"Am. J. Sports Med."},{"issue":"4","key":"2019100601382251000_bib7","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1053\/j.otsm.2004.07.006","article-title":"Options for Glenoid Labral Suture Anchor Fixation","volume":"12","year":"2004","journal-title":"Oper. Tech. Sports Med."},{"issue":"5","key":"2019100601382251000_bib8","doi-asserted-by":"publisher","first-page":"e29","DOI":"10.1016\/j.arthro.2011.03.005","article-title":"Anchor Placement on the Glenoid Faceplate Does Not Improve Stability With Bankart Repair (SS-02)","volume":"27","year":"2011","journal-title":"Arthroscopy"},{"issue":"3","key":"2019100601382251000_bib9","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1080\/10255842.2010.522183","article-title":"Mechanical Variables Affecting Balloon Kyphoplasty Outcome\u2014A Finite Element Study","volume":"15","year":"2012","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"issue":"2","key":"2019100601382251000_bib10","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1007\/s00264-014-2604-7","article-title":"Glenoid Rim Fracture Through Anchor Points After Arthroscopic Bankart Repair for Shoulder Instability","volume":"39","year":"2015","journal-title":"Int. Orthop."},{"issue":"3","key":"2019100601382251000_bib11","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1177\/03635465990270031201","article-title":"Biomechanics of the Bankart Repair: The Relationship Between Glenohumeral Translation and Labral Fixation Site","volume":"27","year":"1999","journal-title":"Am. J. Sports Med."},{"issue":"3","key":"2019100601382251000_bib12","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1007\/s00402-009-0926-5","article-title":"Biomechanical Comparison of Screw-In Suture Anchor-Suture Combinations Used for Bankart Repair","volume":"130","year":"2010","journal-title":"Arch. Orthop. Trauma Surg."},{"issue":"3","key":"2019100601382251000_bib13","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/j.arthro.2008.01.007","article-title":"Enlargement of Drill Holes After Use of a Biodegradable Suture Anchor: Quantitative Study on Consecutive Postoperative Radiographs","volume":"24","year":"2008","journal-title":"Arthroscopy"},{"issue":"6","key":"2019100601382251000_bib14","doi-asserted-by":"publisher","first-page":"e16","DOI":"10.1016\/j.jse.2008.02.014","article-title":"Anchor Hole Enlargement After Arthroscopic Bankart Repair Using Absorbable Suture Anchors: A Report of Three Cases","volume":"17","year":"2008","journal-title":"J. Shoulder Elbow Surg."},{"issue":"7","key":"2019100601382251000_bib15","doi-asserted-by":"publisher","first-page":"716","DOI":"10.1016\/j.arthro.2006.03.017","article-title":"Arthroscopic Stabilization of the Shoulder: A Prospective Randomized Study of Absorbable Versus Nonabsorbable Suture Anchors","volume":"22","year":"2006","journal-title":"Arthroscopy"},{"issue":"2","key":"2019100601382251000_bib16","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1016\/j.arthro.2007.08.011","article-title":"Cyclic Load Testing and Ultimate Failure Strength of Biodegradable Glenoid Anchors","volume":"24","year":"2008","journal-title":"Arthroscopy"},{"issue":"1","key":"2019100601382251000_bib17","doi-asserted-by":"publisher","first-page":"31","DOI":"10.7471\/CT.2014.1658","article-title":"Perianchor Radiolucency Following PEEK Suture Anchor Application Associated with Recurrent Shoulder Dislocation: A Case Report","volume":"165","year":"2014","journal-title":"Clin. Ter."}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4043969\/6414388\/bio_141_10_101003.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4043969\/6414388\/bio_141_10_101003.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,6]],"date-time":"2019-10-06T05:38:30Z","timestamp":1570340310000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/doi\/10.1115\/1.4043969\/955656\/Anchor-Hole-Placement-for-Bankart-Repairs-and-Its"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7,11]]},"references-count":17,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2019,10,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4043969","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"type":"print","value":"0148-0731"},{"type":"electronic","value":"1528-8951"}],"subject":[],"published":{"date-parts":[[2019,7,11]]},"article-number":"101003"}}