{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T12:31:59Z","timestamp":1791462719782,"version":"4.3.4"},"reference-count":34,"publisher":"ASME International","issue":"1","content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2020,1,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Two-dimensional (2D) or three-dimensional (3D) models of blood flow in stenosed arteries can be used to patient-specifically predict outcome metrics, thereby supporting the physicians in decision making processes. However, these models are time consuming which limits the feasibility of output uncertainty quantification (UQ). Accurate surrogates (metamodels) might be the solution. In this study, we aim to demonstrate the feasibility of a generalized polynomial chaos expansion-based metamodel to predict a clinically relevant output metric and to quantify the output uncertainty. As an example, a metamodel was constructed from a recently developed 2D model that was shown to be able to estimate translesional pressure drops in iliac artery stenoses (\u22120.9\u2009\u00b1\u200912.7\u2009mmHg, R2\u2009=\u20090.81). The metamodel was constructed from a virtual database using the adaptive generalized polynomial chaos expansion (agPCE) method. The constructed metamodel was then applied to 25 stenosed iliac arteries to predict the patient-specific pressure drop and to perform UQ. Comparing predicted pressure drops of the metamodel and in vivo measured pressure drops, the mean bias (\u22120.2\u2009\u00b1\u200913.7\u2009mmHg) and the coefficient of determination (R2\u2009=\u20090.80) were as good as of the original 2D computational fluid dynamics (CFD) model. UQ results of the 2D and metamodel were comparable. Estimation of the uncertainty interval using the original 2D model took 14\u2009days, whereas the result of the metamodel was instantly available. In conclusion, it is feasible to quantify the uncertainty of the output metric and perform sensitivity analysis (SA) instantly using a metamodel. Future studies should investigate the possibility to construct a metamodel of more complex problems.<\/jats:p>","DOI":"10.1115\/1.4044502","type":"journal-article","created":{"date-parts":[[2019,9,6]],"date-time":"2019-09-06T10:40:18Z","timestamp":1567766418000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":4,"title":["A Metamodeling Approach for Instant Severity Assessment and Uncertainty Quantification of Iliac Artery Stenoses"],"prefix":"10.1115","volume":"142","author":[{"given":"S. G. H.","family":"Heinen","sequence":"first","affiliation":[{"name":"Department of Radiology, St. Antonius Hospital, Koekoekslaan 1, Nieuwegein 3435 CM, The Netherlands; Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven 5600 MB, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"Gashi","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven 5600 MB, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D. A. F","family":"van den Heuvel","sequence":"additional","affiliation":[{"name":"Department of Radiology, St. Antonius Hospital, Koekoekslaan 1, Nieuwegein 3435 CM, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. P. P. M.","family":"de Vries","sequence":"additional","affiliation":[{"name":"Department of Surgery, Division of Vascular Surgery, University Medical Center Groningen, Groningen 9713 GZ, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"F. N.","family":"van de Vosse","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven 5600 MB , The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T.","family":"Delhaas","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht 6229 ER, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W.","family":"Huberts","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven 5600 MB, The Netherlands; Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University Medical Center, Maastricht 6229 ER, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"33","published-online":{"date-parts":[[2019,10,1]]},"reference":[{"issue":"2","key":"2019100112382039000_bib1","doi-asserted-by":"crossref","first-page":"1385","DOI":"10.1016\/j.jcp.2007.05.020","article-title":"Parametric Uncertainty Analysis of Pulse Wave Propagation in a Model of a Human Arterial Network","volume":"226","year":"2007","journal-title":"J. Comput. Phys."},{"issue":"4","key":"2019100112382039000_bib2","doi-asserted-by":"crossref","first-page":"e34491","DOI":"10.1371\/journal.pone.0034491","article-title":"Patient-Specific Computational Modeling of Upper Extremity Arteriovenous Fistula Creation: Its Feasibility to Support Clinical Decision-Making","volume":"7","year":"2012","journal-title":"PLoS One"},{"issue":"12","key":"2019100112382039000_bib3","doi-asserted-by":"crossref","first-page":"2540","DOI":"10.1016\/j.jbiomech.2016.01.002","article-title":"Uncertainty Quantification in Coronary Blood Flow Simulations: Impact of Geometry, Boundary Conditions and Blood Viscosity","volume":"49","year":"2016","journal-title":"J. Biomech."},{"issue":"3","key":"2019100112382039000_bib4","doi-asserted-by":"crossref","first-page":"e02737","DOI":"10.1002\/cnm.2737","article-title":"Uncertainty Quantification in Virtual Surgery Hemodynamics Predictions for Single Ventricle Palliation","volume":"32","year":"2016","journal-title":"Int. J. Numer. Method. Biomed. Eng."},{"key":"2019100112382039000_bib5","volume-title":"The Stochastic Finite Element Method","year":"1992"},{"key":"2019100112382039000_bib6","volume-title":"The Stochastic Perturbation Method for Computational Mechanics","year":"2013"},{"key":"2019100112382039000_bib7","volume-title":"Springer Series in Operations Research and Financial Engineering","year":"1996"},{"issue":"7","key":"2019100112382039000_bib8","doi-asserted-by":"crossref","first-page":"964","DOI":"10.1016\/j.ress.2007.04.002","article-title":"Global Sensitivity Analysis Using Polynomial Chaos Expansions","volume":"93","year":"2008","journal-title":"Reliab. Eng. Syst. Saf."},{"issue":"3","key":"2019100112382039000_bib9","doi-asserted-by":"crossref","first-page":"1118","DOI":"10.1137\/040615201","article-title":"High-Order Collocation Methods for Differential Equations With Random Inputs","volume":"27","year":"2005","journal-title":"SIAM J. Sci. Comput."},{"issue":"1","key":"2019100112382039000_bib10","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1080\/00401706.1999.10485594","article-title":"A Quantitative Model-Independent Method for Global Sensitivity Analysis of Model Output","volume":"41","year":"1999","journal-title":"Technometrics"},{"issue":"2","key":"2019100112382039000_bib11","article-title":"Making Best Use of Model Evaluations to Compute Sensitivity Indices","volume":"145","year":"2002","journal-title":"Comput. Phys. Commun."},{"key":"2019100112382039000_bib12","volume-title":"Design and Modeling for Computer Experiments","year":"2005"},{"issue":"3","key":"2019100112382039000_bib13","doi-asserted-by":"crossref","first-page":"031001","DOI":"10.1115\/1.4003259","article-title":"A Stochastic Collocation Method for Uncertainty Quantification and Propagation in Cardiovascular Simulations","volume":"133","year":"2011","journal-title":"ASME J. Biomech. Eng."},{"issue":"8","key":"2019100112382039000_bib14","article-title":"A Guide to Uncertainty Quantification and Sensitivity Analysis for Cardiovascular Applications","volume":"32","year":"2016","journal-title":"Int. J. Numer. Method. Biomed. Eng"},{"issue":"12","key":"2019100112382039000_bib15","article-title":"Application of an Adaptive Polynomial Chaos Expansion on Computationally Expensive Three-Dimensional Cardiovascular Models for Uncertainty Quantification and Sensitivity Analysis","volume":"138","year":"2016","journal-title":"ASME J. Biomech. Eng"},{"issue":"2","key":"2019100112382039000_bib16","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1016\/j.probengmech.2009.10.003","article-title":"An Adaptive Algorithm to Build Up Sparse Polynomial Chaos Expansions for Stochastic Finite Element Analysis","volume":"25","year":"2010","journal-title":"Probab. Eng. Mech."},{"issue":"12","key":"2019100112382039000_bib17","doi-asserted-by":"crossref","first-page":"e007328","DOI":"10.1161\/JAHA.117.007328","article-title":"Vivo Validation of Patient-Specific Pressure Gradient Calculations for Iliac Artery Stenosis Severity Assessment","volume":"6","year":"2017","journal-title":"J. Am. Heart Assoc."},{"key":"2019100112382039000_bib18","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1016\/j.jbiomech.2018.11.008","article-title":"The Influence of Model Order Reduction on the Computed Fractional Flow Reserve Using Parameterized Coronary Geometries","volume":"82","year":"2019","journal-title":"J. Biomech."},{"key":"2019100112382039000_bib19","volume-title":"Fluid Mechanics","year":"2011"},{"key":"2019100112382039000_bib20","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/0041-5553(67)90144-9","article-title":"On the Distribution of Points in a Cube and the Approximate Evaluation of Integrals","volume":"7","year":"1967","journal-title":"USSR Comput. Math. Math. Phys."},{"issue":"11","key":"2019100112382039000_bib21","doi-asserted-by":"crossref","first-page":"1216","DOI":"10.1016\/j.ress.2010.06.015","article-title":"Efficient Computation of Global Sensitivity Indices Using Sparse Polynomial Chaos Expansions","volume":"95","year":"2010","journal-title":"Reliab. Eng. Syst. Saf."},{"issue":"2","key":"2019100112382039000_bib22","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1137\/S1064827501387826","article-title":"The Wiener-Askey Polynomial Chaos for Stochastic Differential Equations","volume":"24","year":"2002","journal-title":"SIAM J. Sci. Comput."},{"issue":"2","key":"2019100112382039000_bib23","doi-asserted-by":"crossref","first-page":"734","DOI":"10.1148\/radiol.2382041053","article-title":"Dutch Iliac Stent Trial: Long-Term Results in Patients Randomized for Primary or Selective Stent Placement","volume":"238","year":"2006","journal-title":"Radiology"},{"issue":"8","key":"2019100112382039000_bib24","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1002\/(SICI)1097-0258(19980430)17:8<857::AID-SIM777>3.0.CO;2-E","article-title":"Two-Sided Confidence Intervals for the Single Proportion: Comparison of Seven Methods","volume":"17","year":"1998","journal-title":"Stat. Med."},{"issue":"5","key":"2019100112382039000_bib25","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.1002\/jmri.23752","article-title":"Accuracy and Precision of Vessel Area Assessment: Manual Versus Automatic Lumen Delineation Based on Full-Width at Half-Maximum","volume":"36","year":"2012","journal-title":"J. Magn. Reson. Imaging"},{"issue":"3","key":"2019100112382039000_bib26","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1148\/radiographics.22.3.g02ma11651","article-title":"Cardiovascular Flow Measurement With Phase-Contrast MR Imaging: Basic Facts and Implementation","volume":"22","year":"2002","journal-title":"Radiographics"},{"key":"2019100112382039000_bib27","first-page":"239","article-title":"A Comparison of Three Methods for Selecting Values of Input Variables in the Analysis of Output From a Computer Code","volume":"21","year":"1979","journal-title":"Technometrics"},{"key":"2019100112382039000_bib28","volume-title":"Adaptive Sparse Polynomial Chaos Expansions for Uncertainty Propagation and Sensitivity Analysis","year":"2009"},{"issue":"1","key":"2019100112382039000_bib29","doi-asserted-by":"crossref","first-page":"S5","DOI":"10.1016\/j.jvs.2006.12.037","article-title":"Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II)","volume":"45","year":"2007","journal-title":"J. Vasc. Surg."},{"issue":"26","key":"2019100112382039000_bib30","doi-asserted-by":"crossref","first-page":"1703","DOI":"10.1056\/NEJM199606273342604","article-title":"Measurement of Fractional Flow Reserve to Assess the Functional Severity of Coronary-Artery Stenoses","volume":"334","year":"1996","journal-title":"N. Engl. J. Med."},{"issue":"21","key":"2019100112382039000_bib31","doi-asserted-by":"crossref","first-page":"2105","DOI":"10.1016\/j.jacc.2007.01.087","article-title":"Percutaneous Coronary Intervention of Functionally Nonsignificant Stenosis","volume":"49","year":"2007","journal-title":"J. Am. Coll. Cardiol."},{"issue":"1","key":"2019100112382039000_bib32","first-page":"37","article-title":"Hemodynamic Significance Assessment of Equivocal Iliac Artery Stenoses by Comparing Duplex Ultrasonography With Intra-Arterial Pressure Measurements","volume":"59","year":"2018","journal-title":"J. Cardiovasc. Surg. (Torino)"},{"issue":"8","key":"2019100112382039000_bib33","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1002\/bjs.1800780835","article-title":"Value of Duplex Scanning Compared With Angiography and Pressure Measurement in the Assessment of Aortoiliac Arterial Lesions","volume":"78","year":"1991","journal-title":"Br. J. Surg."},{"issue":"9","key":"2019100112382039000_bib34","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1001\/archsurg.1985.01390330060012","article-title":"Assessment of Aortoiliac Disease Using Hemodynamic Measures","volume":"120","year":"1985","journal-title":"Arch. Surg."}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4044502\/5426883\/bio-18-1404.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4044502\/6030656\/bio_142_01_011010.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,27]],"date-time":"2022-09-27T18:46:46Z","timestamp":1664304406000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/doi\/10.1115\/1.4044502\/958442\/A-Metamodeling-Approach-for-Instant-Severity"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,10,1]]},"references-count":34,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,1,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4044502","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,10,1]]},"article-number":"011010"}}