{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T01:18:21Z","timestamp":1780449501065,"version":"3.54.1"},"reference-count":18,"publisher":"ASME International","issue":"9","license":[{"start":{"date-parts":[[2020,5,14]],"date-time":"2020-05-14T00:00:00Z","timestamp":1589414400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.asme.org\/publications-submissions\/publishing-information\/legal-policies"}],"content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2020,9,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>A magnetic resonance (MR) compatible ergometer has been developed to study contracting lower limb muscles during acquisition of MR spectroscopy data, a technique to noninvasively measure metabolic energy in muscle tissue. Current active and passive MR-compatible ergometer designs lack torque or velocity control to allow precise mechanical measurements during isotonic and isokinetic contractions; incorporating load and velocity controllers while maintaining MR-compatibility is the main challenge. Presented in this paper is the design and evaluation of an MR-compatible ergometer designed to control knee torque or velocity up to 420 N\u00b7m and 270\u2009deg\/s and is able to operate in a 3 Tesla magnetic field. The ergometer comprising of a passive component with no electronics or ferrous materials is located inside the bore of the scanner. The active component with the electronics and actuator located outside of the magnetic field in an adjacent room. The active components connect to the passive components via a cable that passes through the waveguide, a hole in the wall of the scanner room. System evaluations were performed and human subject evaluations were performed that measured the mechanical performance and show the mean percent errors below 9% in isotonic and 2% in isokinetic conditions.<\/jats:p>","DOI":"10.1115\/1.4046585","type":"journal-article","created":{"date-parts":[[2020,3,6]],"date-time":"2020-03-06T06:10:37Z","timestamp":1583475037000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":14,"title":["Magnetic Resonance Compatible Knee Extension Ergometer"],"prefix":"10.1115","volume":"142","author":[{"given":"Youssef","family":"Jaber","sequence":"first","affiliation":[{"name":"Department of Mechanical and Industrial Engineering, University of Massachusetts Amherst, Amherst, MA 01003"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ericber","family":"Jimenez Francisco","sequence":"additional","affiliation":[{"name":"Department of Mechanical and Industrial Engineering, University of Massachusetts Amherst, Amherst, MA 01003"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miles F.","family":"Bartlett","sequence":"additional","affiliation":[{"name":"Department of Kinesiology, University of Massachusetts Amherst, Amherst, MA 01003"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liam F.","family":"Fitzgerald","sequence":"additional","affiliation":[{"name":"Department of Kinesiology, University of Massachusetts Amherst, Amherst, MA 01003"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jane A.","family":"Kent","sequence":"additional","affiliation":[{"name":"Department of Kinesiology, University of Massachusetts Amherst, Amherst, MA 01003"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"IV","given":"Frank C.","family":"Sup","sequence":"additional","affiliation":[{"name":"Department of Mechanical and Industrial Engineering, University of Massachusetts Amherst, Amherst, MA 01003"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"33","published-online":{"date-parts":[[2020,5,14]]},"reference":[{"issue":"4","key":"2020072923562347700_bib1","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1007\/s11548-010-0528-2","article-title":"Mutual Interferences and Design Principles for Mechatronic Devices in Magnetic Resonance Imaging","volume":"6","year":"2011","journal-title":"Int J Comput. Assisted Radiol. Surg."},{"issue":"12","key":"2020072923562347700_bib2","doi-asserted-by":"crossref","first-page":"7430","DOI":"10.1073\/pnas.77.12.7430","article-title":"Noninvasive, Nondestructive Approaches to Cell Bioenergetics","volume":"77","year":"1980","journal-title":"Proc Natl. Acad. Sci."},{"issue":"6","key":"2020072923562347700_bib3","doi-asserted-by":"crossref","first-page":"2139","DOI":"10.1152\/jappl.1995.79.6.2139","article-title":"A Multimode Dynamometer for In Vivo MRS Studies of Human Skeletal Muscle","volume":"79","year":"1995","journal-title":"J Appl. Physiol."},{"issue":"4","key":"2020072923562347700_bib4","doi-asserted-by":"crossref","first-page":"2034","DOI":"10.1152\/jappl.1993.74.4.2034","article-title":"NMR and Analytic Biochemical Evaluation of CRP and Nucleotides in the Human Calf During Muscle Contraction","volume":"74","year":"1993","journal-title":"J Appl. Physiol."},{"issue":"4","key":"2020072923562347700_bib5","doi-asserted-by":"crossref","first-page":"1190","DOI":"10.1172\/JCI113434","article-title":"31p Nuclear Magnetic Resonance Studies of High Energy Phosphates and pH in Human Muscle Fatigue: Comparison of Aerobic and Anaerobic Exercise","volume":"81","year":"1988","journal-title":"J Clin. Invest."},{"issue":"5","key":"2020072923562347700_bib6","doi-asserted-by":"crossref","first-page":"1000","DOI":"10.1002\/mrm.1287","article-title":"Two-Pedal Ergometer for In Vivo MRS Studies of Human Calf Muscles","volume":"46","year":"2001","journal-title":"Magn. Reson. Med."},{"issue":"4","key":"2020072923562347700_bib7","doi-asserted-by":"crossref","first-page":"1349","DOI":"10.1152\/jappl.1998.85.4.1349","article-title":"Creatine Supplementation and Age Influence Muscle Metabolism During Exercise","volume":"85","year":"1998","journal-title":"J Appl. Physiol."},{"issue":"3","key":"2020072923562347700_bib8","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1007\/s10334-008-0117-3","article-title":"Accurate Work-Rate Measurements During In Vivo MRS Studies of Exercising Human Quadriceps","volume":"21","year":"2008","journal-title":"Magn. Reson. Mater. Phys., Biol. Med."},{"issue":"1","key":"2020072923562347700_bib9","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1002\/(SICI)1099-1492(199602)9:1<13::AID-NBM394>3.0.CO;2-9","article-title":"Effects of Active and Passive Recoveries on Splitting of the Inorganic Phosphate Peak Determined by 31p-Nuclear Magnetic Resonance Spectroscopy","volume":"9","year":"1996","journal-title":"NMR Biomed."},{"issue":"3","key":"2020072923562347700_bib10","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1002\/mrm.1910130311","article-title":"A Simple Calf Muscle Ergometer for Use in a Standard Whole-Body MR Scanner","volume":"13","year":"1990","journal-title":"Magn. Reson. Med."},{"issue":"8","key":"2020072923562347700_bib11","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1136\/bjsports-2012-091924","article-title":"Brain Activity and Perceived Exertion During Cycling Exercise: An FMRI Study","volume":"49","year":"2015","journal-title":"Br. J. Sports Med"},{"issue":"1","key":"2020072923562347700_bib12","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1186\/1475-925X-11-13","article-title":"Design and Testing of an MRI-Compatible Cycle Ergometer for Non-Invasive Cardiac Assessments During Exercise","volume":"11","year":"2012","journal-title":"Biomed. Eng. Online"},{"issue":"1","key":"2020072923562347700_bib13","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1002\/1522-2586(200007)12:1<30::AID-JMRI4>3.0.CO;2-S","article-title":"Radiofrequency Energy-Induced Heating During MR Procedures: A Review","volume":"12","year":"2000","journal-title":"J Magn. Reson. Imag."},{"key":"2020072923562347700_bib14","article-title":"Data Table of Stature-for-Age Charts","author":"National Center for Health Statistics","year":"2001"},{"key":"2020072923562347700_bib15","article-title":"Predicting Stature From Bone Measurements","year":"2011"},{"issue":"1","key":"2020072923562347700_bib16","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1002\/ajpa.10257","article-title":"Body Height Estimation Based on Tibia Length in Different Stature Groups","volume":"122","year":"2003","journal-title":"Am. J Phys. Anthropol."},{"issue":"6","key":"2020072923562347700_bib17","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1016\/j.jelekin.2014.08.002","article-title":"Increase in Rate of Force Development With Skin Cooling During Isometric Knee Extension","volume":"24","year":"2014","journal-title":"J Electromyography Kinesiol."},{"issue":"3","key":"2020072923562347700_bib18","first-page":"307","article-title":"Isometric Muscle Force, Rate of Force Development and Knee Extensor Neuromuscular Efficiency Asymmetries at Different Age Groups","volume":"16","year":"2014","journal-title":"Rev. Bras Cineantropometria Desempenho Humano"}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4046585\/6553852\/bio_142_09_095001.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4046585\/6553852\/bio_142_09_095001.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,7,30]],"date-time":"2020-07-30T03:56:40Z","timestamp":1596081400000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/doi\/10.1115\/1.4046585\/1075793\/Magnetic-Resonance-Compatible-Knee-Extension"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5,14]]},"references-count":18,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2020,9,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4046585","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,5,14]]},"article-number":"095001"}}