{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T11:38:22Z","timestamp":1761824302017,"version":"3.41.2"},"reference-count":43,"publisher":"ASME International","issue":"7","license":[{"start":{"date-parts":[[2021,4,7]],"date-time":"2021-04-07T00:00:00Z","timestamp":1617753600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.asme.org\/publications-submissions\/publishing-information\/legal-policies"}],"funder":[{"DOI":"10.13039\/501100004663","name":"Ministry of Science and Technology, Taiwan","doi-asserted-by":"publisher","award":["MOST 108-2314-B-006 -048 -MY2"],"award-info":[{"award-number":["MOST 108-2314-B-006 -048 -MY2"]}],"id":[{"id":"10.13039\/501100004663","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,7,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>The management of thoracolumbar (TL) burst fractures remained challenging. Due to the complex nature of the fractured vertebrae and the lack of clinical and biomechanical evidence, currently, there was still no guideline to select the optimal posterior fixation strategy for TL burst fracture. We utilized a T10-L3 TL finite element model to simulate L1 burst fracture and four surgical constructs with one- or two-level suprajacent and infrajacent instrumentation (U1L1, U1L2, U2L1, and U2L2). This study was aimed to compare the biomechanical properties and find an optimal fixation strategy for TL burst fracture in order to minimize motion in the fractured level without exerting significant burden in the construct. Our result showed that two-level infrajacent fixation (U1L2 and U2L2) resulted in greater global motion reduction ranging from 66.0 to 87.3% compared to 32.0 to 47.3% in one-level infrajacent fixation (U1L1 and U2L1). Flexion produced the largest pathological motion in the fractured level but the differences between the constructs were small, all within 0.26\u2009deg. Comparisons in implant stress showed that U2L1 and U2L2 had an average 25.3 and 24.8% less von Mises stress in the pedicle screws compared to U1L1 and U1L2, respectively. The construct of U2L1 had better preservation of the physiological spinal motion while providing sufficient range of motion reduction at the fractured level. We suggested that U2L1 is a good alternative to the standard long-segment fixation with better preservation of physiological motion and without an increased risk of implant failure.<\/jats:p>","DOI":"10.1115\/1.4050537","type":"journal-article","created":{"date-parts":[[2021,3,17]],"date-time":"2021-03-17T14:04:59Z","timestamp":1615989899000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":11,"title":["Comparison of Posterior Fixation Strategies for Thoracolumbar Burst Fracture: A Finite Element Study"],"prefix":"10.1115","volume":"143","author":[{"given":"Chia-En","family":"Wong","sequence":"first","affiliation":[{"name":"Section of Neurosurgery, Department of Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan 704, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hsuan-Teh","family":"Hu","sequence":"additional","affiliation":[{"name":"Department of Civil Engineering, National Cheng Kung University, Tainan 701, Taiwan; Department of Civil and Disaster Prevention Engineering, National United University, Miaoli 360, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cho-Hsuan","family":"Tsai","sequence":"additional","affiliation":[{"name":"Department of Civil Engineering, National Cheng Kung University, Tainan 701, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jun-Liang","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology, Tungs' Taichung MetroHarbor Hospital, Taichung 433, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chin-Chiang","family":"Hsieh","sequence":"additional","affiliation":[{"name":"Department of Radiology, Tainan Hospital, Ministry of Health and Welfare, Tainan 700, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kuo-Yuan","family":"Huang","sequence":"additional","affiliation":[{"name":"Department of Orthopedics,National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan 701, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"33","published-online":{"date-parts":[[2021,4,7]]},"reference":[{"issue":"6","key":"2021040716034296800_bib1","doi-asserted-by":"crossref","first-page":"422","DOI":"10.3928\/01477447-20100429-24","article-title":"Thoracolumbar Burst Fractures: A Systematic Review of Management","volume":"33","year":"2010","journal-title":"Orthopedics"},{"issue":"3","key":"2021040716034296800_bib2","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.surneu.2006.08.081","article-title":"A Review of the Management of Thoracolumbar Burst Fractures","volume":"67","year":"2007","journal-title":"Surg. Neurol."},{"issue":"1","key":"2021040716034296800_bib3","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1186\/s13018-016-0448-0","article-title":"Analysis of the Independent Risk Factors of Neurologic Deficit After Thoracolumbar Burst Fracture","volume":"11","year":"2016","journal-title":"J. Orthop. Surg. Res."},{"issue":"8","key":"2021040716034296800_bib4","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1097\/00007632-198311000-00003","article-title":"The Three Column Spine and Its Significance in the Classification of Acute Thoracolumbar Spinal Injuries","volume":"8","year":"1983","journal-title":"Spine"},{"issue":"9","key":"2021040716034296800_bib5","doi-asserted-by":"crossref","first-page":"866","DOI":"10.1111\/j.1553-2712.2001.tb01146.x","article-title":"Epidemiology of Thoracolumbar Spine Injury in Blunt Trauma","volume":"8","year":"2001","journal-title":"Acad. Emerg. Med."},{"issue":"2","key":"2021040716034296800_bib6","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1016\/S0887-2171(96)90010-4","article-title":"Thoracolumbar Burst Fracture: Evaluating Stability","volume":"17","year":"1996","journal-title":"Semin. Ultrasound, CT, MR"},{"key":"2021040716034296800_bib7","first-page":"S40","article-title":"Thoracolumbar Burst Fractures Without Neurological Deficit: The Role for Conservative Treatment","year":"2010","journal-title":"Eur. Spine J."},{"key":"2021040716034296800_bib8","first-page":"142","article-title":"Acute Thoracolumbar Burst Fractures in the Absence of Neurologic Deficit. A Comparison Between Operative and Nonoperative Treatment","volume":"189","year":"1984","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"8","key":"2021040716034296800_bib9","doi-asserted-by":"crossref","first-page":"955","DOI":"10.1097\/00007632-199306150-00003","article-title":"Thoracolumbar Burst Fractures. The Clinical Efficacy and Outcome of Nonoperative Management","volume":"18","year":"1993","journal-title":"Spine"},{"issue":"5","key":"2021040716034296800_bib10","first-page":"347","article-title":"Operative Management of Unstable Thoracolumbar Burst Fractures","volume":"20","year":"2010","journal-title":"J. Coll. Phys. Surg."},{"issue":"1","key":"2021040716034296800_bib11","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1016\/j.spinee.2012.10.041","article-title":"Management of Thoracolumbar Spine Fractures","volume":"14","year":"2014","journal-title":"Spine J."},{"issue":"4","key":"2021040716034296800_bib12","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1007\/s007010050310","article-title":"Comparison of Two Types of Surgery for Thoraco-Lumbar Burst Fractures: Combined Anterior and Posterior Stabilisation vs. Posterior Instrumentation Only","volume":"141","year":"1999","journal-title":"Acta Neurochir."},{"issue":"11","key":"2021040716034296800_bib13","doi-asserted-by":"crossref","first-page":"1934","DOI":"10.1007\/s00586-007-0406-y","article-title":"Low Thoracic and Lumbar Burst Fractures: Radiographic and Functional Outcomes","volume":"16","year":"2007","journal-title":"Eur. Spine J."},{"issue":"11 Suppl","key":"2021040716034296800_bib14","first-page":"S70","article-title":"The Biomechanics of Long Versus Short Fixation for Thoracolumbar Spine Fractures","volume":"31","year":"2006","journal-title":"Spine"},{"key":"2021040716034296800_bib15","doi-asserted-by":"crossref","first-page":"e1109","DOI":"10.1016\/j.wneu.2019.05.077","article-title":"Finite Element Analysis of Short Versus Long Segment Posterior Fixation for Thoracolumbar Burst Fracture","volume":"128","year":"2019","journal-title":"World Neurosurg."},{"key":"2021040716034296800_bib16","first-page":"1","article-title":"Age-Related Changes in Trabecular and Cortical Bone Microstructure","volume":"2013","year":"2013","journal-title":"Int. J. Endocrinol."},{"issue":"4","key":"2021040716034296800_bib17","doi-asserted-by":"crossref","first-page":"361","DOI":"10.14444\/6049","article-title":"Differences in Trabecular Bone, Cortical Shell, and Endplate Microstructure Across the Lumbar Spine","volume":"13","year":"2019","journal-title":"Int. J. Spine Surg."},{"issue":"15","key":"2021040716034296800_bib18","doi-asserted-by":"crossref","first-page":"1173","DOI":"10.1097\/BRS.0000000000000925","article-title":"Porosity and Thickness of the Vertebral Endplate Depend on Local Mechanical Loading","volume":"40","year":"2015","journal-title":"Spine"},{"key":"2021040716034296800_bib19","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1016\/j.jmbbm.2017.01.037","article-title":"Biomechanics of the Human Intervertebral Disc: A Review of Testing Techniques and Results","volume":"69","year":"2017","journal-title":"J. Mech. Behav. Biomed. Mater."},{"issue":"15","key":"2021040716034296800_bib20","doi-asserted-by":"crossref","first-page":"1824","DOI":"10.1097\/00007632-199608010-00022","article-title":"Finite Element Applications in Human Cervical Spine Modeling","volume":"21","year":"1996","journal-title":"Spine"},{"issue":"1","key":"2021040716034296800_bib21","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/S0268-0033(98)00036-9","article-title":"Finite Element Analysis of the Cervical Spine: A Material Property Sensitivity Study","volume":"14","year":"1999","journal-title":"Clin. Biomech."},{"issue":"154","key":"2021040716034296800_bib22","article-title":"Optimization of Three-Level Cervical Hybrid Surgery to Prevent Adjacent Segment Disease: A Finite Element Study","volume":"8","year":"2020","journal-title":"Front. Bioeng. Biotechnol."},{"issue":"6","key":"2021040716034296800_bib23","first-page":"1","article-title":"Biomechanical Assessment of Vertebroplasty Combined With Cement-Augmented Screw Fixation for Lumbar Burst Fractures: A Finite Element Analysis","volume":"10","year":"2020","journal-title":"Appl. Sci."},{"issue":"5","key":"2021040716034296800_bib24","doi-asserted-by":"crossref","first-page":"364","DOI":"10.5435\/00124635-200209000-00008","article-title":"Classifications of Thoracic and Lumbar Fractures: Rationale and Supporting Data","volume":"10","year":"2002","journal-title":"J. Am. Acad. Orthop. Surg."},{"issue":"18","key":"2021040716034296800_bib25","doi-asserted-by":"crossref","first-page":"2303","DOI":"10.1097\/00007632-200009150-00007","article-title":"Biomechanical Properties of Anterior Thoracolumbar Multisegmental Fixation: An Analysis of Construct Stiffness and Screw-Rod Strain","volume":"25","year":"2000","journal-title":"Spine"},{"issue":"2","key":"2021040716034296800_bib26","doi-asserted-by":"crossref","first-page":"234","DOI":"10.3171\/2010.3.SPINE09267","article-title":"The Biomechanical Contribution of Varying Posterior Constructs Following Anterior Thoracolumbar Corpectomy and Reconstruction","volume":"13","year":"2010","journal-title":"J. Neurosurg. Spine"},{"issue":"2","key":"2021040716034296800_bib27","doi-asserted-by":"crossref","first-page":"252","DOI":"10.3171\/spi.2000.93.2.0252","article-title":"In Vitro Biomechanical Analysis of Three Anterior Thoracolumbar Implants","volume":"93","year":"2000","journal-title":"J. Neurosurg. Spine"},{"issue":"4","key":"2021040716034296800_bib28","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1016\/j.spinee.2008.11.012","article-title":"Biomechanical Rigidity of an All-Polyetheretherketone Anterior Thoracolumbar Spinal Reconstruction Construct: An In Vitro Corpectomy Model","volume":"9","year":"2009","journal-title":"Spine J."},{"issue":"3","key":"2021040716034296800_bib29","doi-asserted-by":"crossref","first-page":"e514","DOI":"10.3928\/01477447-20160427-09","article-title":"Biomechanical Analysis of Pedicle Screw Fixation for Thoracolumbar Burst Fractures","volume":"39","year":"2016","journal-title":"Orthopedics"},{"issue":"5","key":"2021040716034296800_bib30","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1016\/j.jocn.2014.11.031","article-title":"Vertebroplasty Plus Short Segment Pedicle Screw Fixation in a Burst Fracture Model in Cadaveric Spines","volume":"22","year":"2015","journal-title":"J. Clin. Neurosci."},{"issue":"3","key":"2021040716034296800_bib31","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1097\/BSD.0b013e31807a2f61","article-title":"In Vitro Analysis of Anterior and Posterior Fixation in an Experimental Unstable Burst Fracture Model","volume":"21","year":"2008","journal-title":"J. Spinal Disord. Tech."},{"issue":"1","key":"2021040716034296800_bib32","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1186\/1749-799X-4-28","article-title":"Two Levels Above and One Level Below Pedicle Screw Fixation for the Treatment of Unstable Thoracolumbar Fracture With Partial or Intact Neurology","volume":"4","year":"2009","journal-title":"J. Orthop. Surg. Res."},{"issue":"8","key":"2021040716034296800_bib33","doi-asserted-by":"crossref","first-page":"1145","DOI":"10.1007\/s00586-007-0310-5","article-title":"Treatment of Unstable Thoracolumbar Junction Burst Fractures With Short- or Long-Segment Posterior Fixation in Magerl Type a Fractures","volume":"16","year":"2007","journal-title":"Eur. Spine J."},{"issue":"1","key":"2021040716034296800_bib34","doi-asserted-by":"crossref","first-page":"150","DOI":"10.4184\/asj.2017.11.1.150","article-title":"Short Segment Versus Long Segment Pedicle Screws Fixation in Management of Thoracolumbar Burst Fractures: Meta-Analysis","volume":"11","year":"2017","journal-title":"Asian Spine J."},{"issue":"2","key":"2021040716034296800_bib35","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/j.jbiomech.2010.10.021","article-title":"Challenges to Bone Formation in Spinal Fusion","volume":"44","year":"2011","journal-title":"J. Biomech."},{"issue":"8 Suppl","key":"2021040716034296800_bib36","first-page":"S449","article-title":"Classification of Pseudarthroses of the Lumbar Spine","volume":"16","year":"1991","journal-title":"Spine"},{"issue":"3","key":"2021040716034296800_bib37","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1016\/j.spinee.2008.08.002","article-title":"Biomechanical Evaluation and Comparison of Polyetheretherketone Rod System to Traditional Titanium Rod Fixation","volume":"9","year":"2009","journal-title":"Spine J."},{"issue":"22","key":"2021040716034296800_bib38","doi-asserted-by":"crossref","first-page":"2655","DOI":"10.1097\/00007632-199711150-00014","article-title":"The Effect of Spinal Destabilization and Instrumentation on Lumbar Intradiscal Pressure: An In vitro Biomechanical Analysis","volume":"22","year":"1997","journal-title":"Spine"},{"key":"2021040716034296800_bib39","first-page":"13","article-title":"Modelling Bone Tissue Fracture and Healing: A Review","volume":"71","year":"2004","journal-title":"Eng. Fract. Mech."},{"issue":"1","key":"2021040716034296800_bib40","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/0021-9290(94)00156-1","article-title":"Cyclic Mechanical Property Degradation During Fatigue Loading of Cortical Bone","volume":"29","year":"1996","journal-title":"J. Biomech."},{"issue":"2","key":"2021040716034296800_bib41","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1111\/j.1757-7861.2009.00022.x","article-title":"Long-Term Results of Thoracolumbar and Lumbar Burst Fractures After Short-Segment Pedicle Instrumentation, With Special Reference to Implant Failure and Correction Loss","volume":"1","year":"2009","journal-title":"Orthop. Surg."},{"issue":"2","key":"2021040716034296800_bib42","doi-asserted-by":"crossref","first-page":"162","DOI":"10.2106\/00004623-199302000-00002","article-title":"Early Failure of Short-Segment Pedicle Instrumentation for Thoracolumbar Fractures. A Preliminary Report","volume":"75","year":"1993","journal-title":"J. Bone Jt. surgery. Am."},{"issue":"4","key":"2021040716034296800_bib43","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1038\/sc.2010.159","article-title":"Posterior\/Anterior Combined Surgery for Thoracolumbar Burst Fractures\u2013Posterior Instrumentation With Pedicle Screws and Laminar Hooks, Anterior Decompression and Strut Grafting","volume":"49","year":"2011","journal-title":"Spinal Cord"}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4050537\/6678531\/bio_143_07_071007.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4050537\/6678531\/bio_143_07_071007.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,7]],"date-time":"2021-04-07T21:42:16Z","timestamp":1617831736000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/143\/7\/071007\/1104431\/Comparison-of-Posterior-Fixation-Strategies-for"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4,7]]},"references-count":43,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2021,7,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4050537","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"type":"print","value":"0148-0731"},{"type":"electronic","value":"1528-8951"}],"subject":[],"published":{"date-parts":[[2021,4,7]]},"article-number":"071007"}}