{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,22]],"date-time":"2026-06-22T11:39:42Z","timestamp":1782128382489,"version":"3.54.5"},"reference-count":53,"publisher":"ASME International","issue":"9","license":[{"start":{"date-parts":[[2022,3,30]],"date-time":"2022-03-30T00:00:00Z","timestamp":1648598400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.asme.org\/publications-submissions\/publishing-information\/legal-policies"}],"content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,9,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>This research aimed to examine the impact of a proposed flow stent (PFS) on different abdominal artery shapes. For that purpose, a finite element-based model using the computational fluid dynamics (CFD) method is developed. The effect of PFS intervention on the hemodynamic efficiency is estimated by all of the significant criteria used for the evaluation of aneurysm occlusion and possible rupture; the flow velocity, pressure, wall shear stress (WSS), and WSS-related indices. Results showed that PFS intervention preserves the effects of high flowrate and decreases irregular flow recirculation in the sac of the aneurysm. The flow velocity reduction inside the aneurysm sac is in the range of 55% to 80% and the time-averaged wall shear stress (TAWSS) reduction is in the range of 42% to 53% by PFS deployment. The simulation results implies that PFS could heal an aneurysm efficiently with a mechanism that causes the development of thrombus and ultimately leads to aneurysm resorption.<\/jats:p>","DOI":"10.1115\/1.4053999","type":"journal-article","created":{"date-parts":[[2022,3,3]],"date-time":"2022-03-03T06:27:52Z","timestamp":1646288872000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":4,"title":["A Finite Element-Based Analysis of a Hemodynamics Efficient Flow Stent Suitable for Different Abdominal Aneurysm Shapes"],"prefix":"10.1115","volume":"144","author":[{"given":"Ayat","family":"Nada","sequence":"first","affiliation":[{"name":"Department of Computers and Systems, Electronics Research Institute, Cairo, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mahmoud A.","family":"Fakhr","sequence":"additional","affiliation":[{"name":"Department of Computers and Systems, Electronics Research Institute, Cairo, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamed Tarek I.","family":"El-Wakad","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Faculty of Engineering & Technology, Future University, Cairo 11835, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammed A.","family":"Hassan","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Faculty of Engineering, Helwan University, Cairo 11111, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"33","published-online":{"date-parts":[[2022,3,30]]},"reference":[{"issue":"8","key":"2022033014064561900_bib1","first-page":"e254","article-title":"Heart Disease and Stroke Statistics\u20142021 Update","volume":"143","year":"2021","journal-title":"Am. Heart Assoc. Circ."},{"issue":"5","key":"2022033014064561900_bib2","doi-asserted-by":"crossref","first-page":"852","DOI":"10.1097\/SLA.0000000000003529","article-title":"Saccular Abdominal Aortic Aneurysms: Patient Characteristics, Clinical Presentation, Treatment, and Outcomes in The Netherlands","volume":"270","year":"2019","journal-title":"Ann. Surg."},{"key":"2022033014064561900_bib3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.2147\/IPRP.S133088","article-title":"Cardiovascular Disease as a Leading Cause of Death: How Are Pharmacists Getting Involved","volume":"8","year":"2019","journal-title":"Integr. Pharmacy Res. Practice"},{"issue":"7","key":"2022033014064561900_bib4","first-page":"CD001835","article-title":"Surgery for Small Asymptomatic Abdominal Aortic Aneurysms","volume":"2020","year":"2020","journal-title":"Cochrane Database Systematic Rev."},{"issue":"3","key":"2022033014064561900_bib5","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1016\/j.ejvs.2019.11.030","article-title":"Editor's Choice\u2013Endovascular vs. open Repair for Abdominal Aortic Aneurysm: Systematic Review and Meta-Analysis of Updated Peri-Operative and Long Term Data of Randomised Controlled Trials","volume":"59","year":"2020","journal-title":"Eur. J. Vasc. Endovascular Surg."},{"issue":"7","key":"2022033014064561900_bib6","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1016\/j.medengphy.2015.04.011","article-title":"On Growth Measurements of Abdominal Aortic Aneurysms Using Maximally Inscribed Spheres","volume":"37","year":"2015","journal-title":"Med. Eng. Phys."},{"issue":"1","key":"2022033014064561900_bib7","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.bbe.2019.02.005","article-title":"Impact of Coronary Tortuosity on the Artery Hemodynamics","volume":"40","year":"2020","journal-title":"Biocyber. Biomed. Eng."},{"issue":"9","key":"2022033014064561900_bib8","first-page":"1","article-title":"Computational Growth and Remodeling of Abdominal Aortic Aneurysms Constrained by the Spine","volume":"137","year":"2015","journal-title":"ASME J. Biomech. Eng."},{"issue":"7","key":"2022033014064561900_bib9","doi-asserted-by":"crossref","first-page":"1459","DOI":"10.1007\/s10439-013-0786-6","article-title":"The Role of Geometric and Biomechanical Factors in Abdominal Aortic Aneurysm Rupture Risk Assessment","volume":"41","year":"2013","journal-title":"Ann. Biomed. Eng."},{"issue":"5","key":"2022033014064561900_bib10","doi-asserted-by":"crossref","first-page":"1502","DOI":"10.1007\/s10439-015-1461-x","article-title":"Association of Intraluminal Thrombus, Hemodynamic Forces, and Abdominal Aortic Aneurysm Expansion Using Longitudinal CT Images","volume":"44","year":"2016","journal-title":"Ann. Biomed. Eng."},{"issue":"6","key":"2022033014064561900_bib11","doi-asserted-by":"crossref","first-page":"957","DOI":"10.1177\/1526602816657086","article-title":"Local Diameter, Wall Stress, and Thrombus Thickness Influence the Local Growth of Abdominal Aortic Aneurysms","volume":"23","year":"2016","journal-title":"J. Endovasc, Ther."},{"issue":"11","key":"2022033014064561900_bib12","first-page":"90","article-title":"Comparison of Endovascular Aneurysm Repair With Open Repair in Patients With Abdominal Aortic Aneurysm, 30-Day Operative Mortality RESULTS: Randomised Controlled Trial. Results of the EVAR 1","volume":"44","year":"2004","journal-title":"Trial. fdsKardiologiia"},{"issue":"4","key":"2022033014064561900_bib13","doi-asserted-by":"crossref","first-page":"87","DOI":"10.4037\/ccn2014184","article-title":"Endovascular Repair of Abdominal Aortic Aneurysm","volume":"34","year":"2014","journal-title":"Crit. Care Nurse"},{"issue":"4","key":"2022033014064561900_bib14","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1583\/04-1465.1","article-title":"Flow Visualization in a Model of a Bifurcated Stent-Graft","volume":"12","year":"2005","journal-title":"J. Endovascular Ther."},{"issue":"3","key":"2022033014064561900_bib15","doi-asserted-by":"crossref","first-page":"S123","DOI":"10.1016\/j.jtcvs.2012.11.052","article-title":"A Brief History of Aortic Surgery: Insight Into Distal Aortic Repair","volume":"145","year":"2013","journal-title":"J. Thorac. Cardiovasc, Surg"},{"issue":"6","key":"2022033014064561900_bib16","doi-asserted-by":"crossref","first-page":"1653","DOI":"10.1016\/j.jvs.2017.04.057","article-title":"Thirty-Day Outcomes After Fenestrated Endovascular Repair Are Superior to Open Repair of Abdominal Aortic Aneurysms Involving Visceral Vessels","volume":"66","year":"2017","journal-title":"J. Vasc. Surg."},{"issue":"6","key":"2022033014064561900_bib17","doi-asserted-by":"crossref","first-page":"768","DOI":"10.1114\/1.1495867","article-title":"Particle Image Velocimetry Assessment of Stent Design Influence on Intra-Aneurysmal Flow","volume":"30","year":"2002","journal-title":"Ann. Biomed. Eng."},{"issue":"5","key":"2022033014064561900_bib18","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1080\/03091902.2021.1912204","article-title":"Studying the Effect of Stent Thickness and Porosity on Post-Stent Implantation Hemodynamics","volume":"45","year":"2021","journal-title":"J. Med. Eng. Technol."},{"key":"2022033014064561900_bib19","first-page":"1","article-title":"A Comparative Study Between CFD and FSI Hemodynamic Parameters in a Patient-Specific Giant Saccular Cerebral Aneurysm","volume":"53","year":"2021","journal-title":"AUT J. Model. Simul."},{"key":"2022033014064561900_bib20","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.jbiomech.2018.08.026","article-title":"Numerical Simulation of Aneurysmal Haemodynamics With Calibrated Porous-Medium Models of Flow-Diverting Stents","volume":"80","year":"2018","journal-title":"J. Biomech."},{"issue":"1","key":"2022033014064561900_bib21","doi-asserted-by":"crossref","first-page":"E12","DOI":"10.3171\/2019.4.FOCUS19189","article-title":"Computational Fluid Dynamics as a Risk Assessment Tool for Aneurysm Rupture","volume":"47","year":"2019","journal-title":"Neurosurg. Focus"},{"key":"2022033014064561900_bib22","first-page":"109","article-title":"Comparison Study of Flow Diverting Stents for the Treatment of a Patient-Specific Abdominal Aortic Aneurysm","volume-title":"NILES","year":"2021"},{"issue":"1","key":"2022033014064561900_bib23","first-page":"10","article-title":"Hemodynamic Performance of Multilayer Stents in the Treatment of Aneurysms With a Branch Attached","volume":"9","year":"2019","journal-title":"Sci. Rep."},{"issue":"1","key":"2022033014064561900_bib24","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1583\/11-3551.1","article-title":"Endovascular Treatment of a Tuberculous Thoracoabdominal Aneurysm With the Multilayer Stent","volume":"19","year":"2012","journal-title":"J. Endovasc.Ther."},{"issue":"1","key":"2022033014064561900_bib25","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1583\/11-3398.1","article-title":"Treatment of Juxtarenal Aortic Aneurysm With the Multilayer Stent","volume":"19","year":"2012","journal-title":"J. Endovasc. Ther."},{"issue":"3","key":"2022033014064561900_bib26","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1586\/17434440.2015.1030339","article-title":"Multilayer Flow Modulator Stent Technology: A Treatment Revolution for U.S. Patients?","volume":"12","year":"2015","journal-title":"Expert Rev. Med. Dev."},{"issue":"2","key":"2022033014064561900_bib27","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1007\/s10439-009-9843-6","article-title":"Hemodynamics of the Normal Aorta Compared to Fusiform and Saccular Abdominal Aortic Aneurysms With Emphasis on a Potential Thrombus Formation Mechanism","volume":"38","year":"2010","journal-title":"Ann. Biomed. Eng."},{"issue":"2","key":"2022033014064561900_bib28","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1583\/07-2222.1","article-title":"Treatment of Renal Artery Aneurysm With the Multilayer Stent","volume":"15","year":"2008","journal-title":"J. Endovasc. Ther."},{"issue":"5","key":"2022033014064561900_bib29","doi-asserted-by":"crossref","first-page":"H1182","DOI":"10.1152\/ajpheart.00199.2018","article-title":"Multilayer Flow Modulator Enhances Vital Organ Perfusion in Patients With Type B Aortic Dissection","volume":"315","year":"2018","journal-title":"Am. J. Physiol.-Heart Circ. Physiol."},{"key":"2022033014064561900_bib30","first-page":"1","article-title":"Hemodynamic Study of Flow Remodeling Stent Graft for the Treatment of Highly Angulated Abdominal Aortic Aneurysm","volume":"2016","year":"2016","journal-title":"Comput. Math. Methods Med."},{"issue":"2","key":"2022033014064561900_bib31","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1111\/aor.12993","article-title":"Is Multiple Overlapping Uncovered Stents Technique Suitable for Aortic Aneurysm Repair?","volume":"42","year":"2018","journal-title":"Artif. Organs."},{"key":"2022033014064561900_bib32","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1016\/j.jbiomech.2017.06.048","article-title":"Influence of Overlapping Pattern of Multiple Overlapping Uncovered Stents on the Local Mechanical Environment: A Patient-Specific Parameter Study","volume":"60","year":"2017","journal-title":"J. Biomech."},{"key":"2022033014064561900_bib33","volume-title":"Parametric Modeling With SOLIDWORKS 2021","year":"2021"},{"key":"2022033014064561900_bib34","volume-title":"COMSOL \u2013 Multiphysics Modeling and Simulation Software"},{"key":"2022033014064561900_bib35","first-page":"1","article-title":"Biomechanical Investigation of Disturbed Hemodynamics-Induced Tissue Degeneration in Abdominal Aortic Aneurysms Using Computational and Experimental Techniques","volume":"7","year":"2019","journal-title":"Front. Bioeng. Biotechnol."},{"key":"2022033014064561900_bib36","first-page":"1","article-title":"CFD Modelling of Abdominal Aortic Aneurysm on Hemodynamic Loads Using a Realistic Geometry With CT","volume":"2013","year":"2013","journal-title":"Comput. Math. Methods Med.."},{"issue":"7","key":"2022033014064561900_bib37","doi-asserted-by":"crossref","first-page":"1341","DOI":"10.3390\/app9071341","article-title":"CFD-Based Comparison Study of a New Flow Diverting Stent and Commercially-Available Ones for the Treatment of Cerebral Aneurysms","volume":"9","year":"2019","journal-title":"Appl. Sci."},{"issue":"3","key":"2022033014064561900_bib38","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1007\/s10237-016-0853-7","article-title":"Wall Shear Stress Exposure Time: A Lagrangian Measure of Near-Wall Stagnation and Concentration in Cardiovascular Flows","volume":"16","year":"2017","journal-title":"Biomech. Model. Mechanobiol."},{"issue":"7","key":"2022033014064561900_bib39","doi-asserted-by":"crossref","first-page":"071005","DOI":"10.1115\/1.4004410","article-title":"Impact of Stents and Flow Diverters on Hemodynamics in Idealized Aneurysm Models","volume":"133","year":"2011","journal-title":"ASME J. Biomech. Eng."},{"issue":"1","key":"2022033014064561900_bib40","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1161\/STROKEAHA.110.592923","article-title":"Hemodynamic-Morphologic Discriminants for Intracranial Aneurysm Rupture","volume":"42","year":"2011","journal-title":"Stroke"},{"key":"2022033014064561900_bib41","article-title":"A Haemodynamic Predictor of Intraluminal Thrombus Formation in Abdominal Aortic Aneurysms","year":"2014","journal-title":"Proc. R. Soc. A: Math., Phys. Eng. Sci."},{"key":"2022033014064561900_bib42","article-title":"A Comparison of Hemodynamic Metrics and Intraluminal Thrombus Burden in a Common Iliac Artery Aneurysm","year":"2017","journal-title":"Int. J. Numer. Methods Biomed. Eng."},{"issue":"4","key":"2022033014064561900_bib43","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1007\/s10439-020-02448-6","article-title":"Numerical Study of Atrial Fibrillation Effects on Flow Distribution in Aortic Circulation","volume":"48","year":"2020","journal-title":"Ann. Biomed. Eng."},{"key":"2022033014064561900_bib44","doi-asserted-by":"crossref","first-page":"103338","DOI":"10.1016\/j.compbiomed.2019.103338","article-title":"Stent-Induced Vessel Deformation After Intracranial Aneurysm Treatment\u2013A Hemodynamic Pilot Study","volume":"111","year":"2019","journal-title":"Comput. Biol. Med."},{"issue":"2","key":"2022033014064561900_bib45","first-page":"119","article-title":"Patient-Specific Flow Descriptors and Normalised Wall Index in Peripheral Artery Disease: A Preliminary Study","volume":"6","year":"2018","journal-title":"Comput. Methods Biomech. Biomed. Eng.: Imag Visual."},{"issue":"10","key":"2022033014064561900_bib46","doi-asserted-by":"crossref","first-page":"2041","DOI":"10.1016\/j.jbiomech.2015.03.028","article-title":"Hemodynamic Insight Into Overlapping Bare-Metal Stents Strategy in the Treatment of Aortic Aneurysm","volume":"48","year":"2015","journal-title":"J. Biomech."},{"issue":"3","key":"2022033014064561900_bib47","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1583\/12-4077MR-R.1","article-title":"One-Year Results of the Multilayer Flow Modulator Stent in the Management of Thoracoabdominal Aortic Aneurysms and Type B Dissections","volume":"20","year":"2013","journal-title":"J. Endovasc. Ther."},{"issue":"1","key":"2022033014064561900_bib48","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1583\/13-4514MR.1","article-title":"When Not to Implant the Multilayer Flow Modulator: Lessons Learned From Application Outside the Indications for Use in Patients With Thoracoabdominal Pathologies","volume":"21","year":"2014","journal-title":"J. Endovasc. Ther."},{"issue":"1","key":"2022033014064561900_bib49","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1007\/s10439-014-1095-4","article-title":"Change of Direction in the Biomechanics of Atherosclerosis","volume":"43","year":"2015","journal-title":"Ann. Biomed. Eng."},{"key":"2022033014064561900_bib50","doi-asserted-by":"crossref","first-page":"106196","DOI":"10.1016\/j.cmpb.2021.106196","article-title":"A Study on the Accuracy and Efficiency of the Improved Numerical Model for Stent Implantation Using Clinical Data","volume":"207","year":"2021","journal-title":"Comput. Methods Programs Biomed."},{"key":"2022033014064561900_bib51","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1016\/j.jbiomech.2019.01.019","article-title":"Hemodynamic Analysis of a Novel Stent Graft Design With Slit Perforations in Thoracic Aortic Aneurysm","volume":"85","year":"2019","journal-title":"J Biomech."},{"issue":"9","key":"2022033014064561900_bib52","doi-asserted-by":"crossref","first-page":"4263","DOI":"10.1002\/mp.13658","article-title":"Role of Intraluminal Thrombus in Abdominal Aortic Aneurysm Ruptures: A Hemodynamic Point of View","volume":"46","year":"2019","journal-title":"Med. Phys."},{"issue":"19","key":"2022033014064561900_bib53","doi-asserted-by":"crossref","first-page":"4143","DOI":"10.3390\/app9194143","article-title":"Impacts of Internal Carotid Artery Revascularization on Flow in Anterior Communicating Artery Aneurysm: A Preliminary Multiscale Numerical Investigation","volume":"9","year":"2019","journal-title":"Appl. Sci."}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/144\/9\/091006\/6868850\/bio_144_09_091006.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/144\/9\/091006\/6868850\/bio_144_09_091006.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,30]],"date-time":"2022-03-30T19:07:20Z","timestamp":1648667240000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/144\/9\/091006\/1137925\/A-Finite-Element-Based-Analysis-of-a-Hemodynamics"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,30]]},"references-count":53,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2022,9,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4053999","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,30]]},"article-number":"091006"}}