{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,28]],"date-time":"2026-01-28T07:03:30Z","timestamp":1769583810448,"version":"3.49.0"},"reference-count":49,"publisher":"ASME International","issue":"10","license":[{"start":{"date-parts":[[2022,4,25]],"date-time":"2022-04-25T00:00:00Z","timestamp":1650844800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.asme.org\/publications-submissions\/publishing-information\/legal-policies"}],"funder":[{"DOI":"10.13039\/100000146","name":"Division of Chemical, Bioengineering, Environmental, and Transport Systems","doi-asserted-by":"publisher","award":["1829408"],"award-info":[{"award-number":["1829408"]}],"id":[{"id":"10.13039\/100000146","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,10,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>We have performed three-dimensional high-resolution numerical simulations of a bi-leaflet mechanical heart valve implanted at different orientations in an anatomic left ventricle-aorta obtained from magnetic resonance imaging of a volunteer. The thoroughly validated overset curvilinear-immersed boundary fluid\u2013structure interaction flow solver is used in which the aorta and left ventricle (LV) are discretized with boundary-conforming and nonconforming curvilinear grids, respectively. The motion of the left ventricle wall is prescribed based on a lumped parameter model while the motion of the leaflets is calculated using a strongly coupled fluid\u2013structure interaction algorithm enhanced with Aitken convergence technique. We carried out simulations for three valve orientations, which differ from each other by 45\u2009deg, and compared the leaflet motion and flow field for multiple cycles. Our results show reproducible and relatively symmetrical opening for all valve orientations. The presence of small-scale vortical structures after peak systole causes significant cycle-to-cycle variations in valve kinematics during the closing phase for all valve orientations. Furthermore, our results show that valve orientation does not have a significant effect on the distribution of viscous shear stress in the ascending aorta. Additionally, two different mathematical activation models including linear level of activation and Soares model are used to quantify the platelet activation in the ascending aorta. The results show that the valve orientation does not significantly affect (less than 8%) the total platelet activation in the ascending aorta.<\/jats:p>","DOI":"10.1115\/1.4054411","type":"journal-article","created":{"date-parts":[[2022,4,25]],"date-time":"2022-04-25T05:32:13Z","timestamp":1650864733000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":9,"title":["The Effects of Implantation Orientation of a Bileaflet Mechanical Heart Valve in an Anatomic Left Ventricle-Aorta Configuration"],"prefix":"10.1115","volume":"144","author":[{"given":"Hossein","family":"Asadi","sequence":"first","affiliation":[{"name":"J. Mike Walker '66 Department of Mechanical Engineering, Texas A&M University , College Station, TX 77843"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammadali","family":"Hedayat","sequence":"additional","affiliation":[{"name":"J. Mike Walker '66 Department of Mechanical Engineering, Texas A&M University , College Station, TX 77843"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Iman","family":"Borazjani","sequence":"additional","affiliation":[{"name":"J. Mike Walker '66 Department of Mechanical Engineering, Texas A&M University , College Station, TX 77843"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"33","published-online":{"date-parts":[[2022,5,12]]},"reference":[{"issue":"8","key":"2023051200040202700_bib1","first-page":"e254","article-title":"Heart Disease and Stroke Statistics\u20132021 Update: A Report From the American Heart Association","volume":"143","year":"2021","journal-title":"Circulation"},{"issue":"28","key":"2023051200040202700_bib2","doi-asserted-by":"crossref","first-page":"2183","DOI":"10.1093\/eurheartj\/ehx141","article-title":"Mechanical Versus Bioprosthetic Aortic Valve Replacement","volume":"38","year":"2017","journal-title":"Eur. Heart J."},{"issue":"3","key":"2023051200040202700_bib3","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1016\/j.jtcvs.2018.10.146","article-title":"Long-Term Outcomes of Mechanical Versus Biological Aortic Valve Prosthesis: Systematic Review and Meta-Analysis","volume":"158","year":"2019","journal-title":"J. Thorac. Cardiovasc. Surg."},{"issue":"4","key":"2023051200040202700_bib4","doi-asserted-by":"crossref","first-page":"1442","DOI":"10.1007\/s10439-010-9936-2","article-title":"High-Shear Stress Sensitizes Platelets to Subsequent Low-Shear Conditions","volume":"38","year":"2010","journal-title":"Ann. Biomed. Eng."},{"issue":"10","key":"2023051200040202700_bib5","doi-asserted-by":"crossref","first-page":"2314","DOI":"10.1007\/s10439-015-1394-4","article-title":"Emerging Trends in Heart Valve Engineering: Part IV. Computational Modeling and Experimental Studies","volume":"43","year":"2015","journal-title":"Ann. Biomed. Eng."},{"issue":"1\u20132","key":"2023051200040202700_bib6","first-page":"75","article-title":"A Review of Fluid-Structure Interaction Simulations of Prosthetic Heart Valves","volume":"25","year":"2015","journal-title":"J. Long-Term Effects Med. Implants"},{"key":"2023051200040202700_bib7","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.jbiomech.2017.03.002","article-title":"Platelet Activation of Mechanical Versus Bioprosthetic Heart Valves During Systole","volume":"56","year":"2017","journal-title":"J. Biomech."},{"key":"2023051200040202700_bib8","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1016\/j.jbiomech.2018.12.003","article-title":"Comparison of Platelet Activation Through Hinge versus Bulk Flow in Bileaflet Mechanical Heart Valves","volume":"83","year":"2019","journal-title":"J. Biomech."},{"issue":"1","key":"2023051200040202700_bib9","article-title":"Comparative Study of Wall-Shear Stress at the Ascending Aorta for Different Mechanical Heart Valve Prostheses","volume":"142","year":"2020","journal-title":"ASME J. Biomech. Eng."},{"issue":"2","key":"2023051200040202700_bib10","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1115\/1.1448519","article-title":"An Analysis of Turbulent Shear Stresses in Leakage Flow Through a Bileaflet Mechanical Prostheses","volume":"124","year":"2002","journal-title":"ASME J. Biomech. Eng."},{"issue":"4","key":"2023051200040202700_bib11","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1016\/j.ejcts.2004.06.019","article-title":"Influence of Bileaflet prosthetic Mitral Valve Orientation on Left Ventricular Flow\u2013An Experimental In Vivo Magnetic Resonance Imaging study","volume":"26","year":"2004","journal-title":"Eur. J. Cardio-Thorac. Surg."},{"issue":"6","key":"2023051200040202700_bib12","doi-asserted-by":"crossref","first-page":"1370","DOI":"10.1007\/s10439-014-1102-9","article-title":"Influence of Valve Size, Orientation and Downstream Geometry of an Aortic BMHV on Leaflet Motion and Clinically Used Valve Performance Parameters","volume":"43","year":"2015","journal-title":"Ann. Biomed. Eng."},{"issue":"5","key":"2023051200040202700_bib13","first-page":"548","article-title":"Medtronic Hall Versus St. Jude Medical Mechanical Aortic Valve: Downstream Turbulences With Respect to Rotation in Pigs","volume":"7","year":"1998","journal-title":"J. Heart Valve Dis."},{"issue":"5","key":"2023051200040202700_bib14","doi-asserted-by":"crossref","first-page":"925","DOI":"10.1067\/mtc.2002.126046","article-title":"Effect of Mechanical Aortic Valve Orientation on Coronary Artery Flow: Comparison of Tilting Disc Versus Bileaflet Prostheses in Pigs","volume":"124","year":"2002","journal-title":"J. Thorac. Cardiovasc. Surg."},{"issue":"2","key":"2023051200040202700_bib15","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1007\/s10047-008-0410-y","article-title":"Dynamic Particle Image Velocimetry Study of the Aortic Flow Field of Contemporary Mechanical Bileaflet Prostheses","volume":"11","year":"2008","journal-title":"J. Artif. Organs"},{"key":"2023051200040202700_bib16","first-page":"769","article-title":"In Vitro Study of the Correlation Between the Aortic Flow Field Affected by the Bileaflet Mechanical Valves and Coronary Circulation","volume-title":"Fifth European Conference of the International Federation for Medical and Biological Engineering","year":"2011"},{"issue":"11","key":"2023051200040202700_bib17","article-title":"The Effect of Implantation Orientation of a Bileaflet Mechanical Heart Valve on Kinematics and Hemodynamics in an Anatomic Aorta","volume":"132","year":"2010","journal-title":"ASME J. Biomech. Eng."},{"key":"2023051200040202700_bib18","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1017\/jfm.2016.582","article-title":"Effects of Bileaflet Mechanical Heart Valve Orientation on Fluid Stresses and Coronary Flow","volume":"806","year":"2016","journal-title":"J. Fluid Mech."},{"issue":"2","key":"2023051200040202700_bib19","first-page":"E20","article-title":"Numerical Investigation on the Effect of Bileaflet Mechanical Heart Valve's Implantation Tilting Angle and Aortic Root Geometry on Intermittent Regurgitation and Platelet Activation","volume":"44","year":"2020","journal-title":"Artif. Organs"},{"issue":"16","key":"2023051200040202700_bib20","doi-asserted-by":"crossref","first-page":"7587","DOI":"10.1016\/j.jcp.2008.04.028","article-title":"Curvilinear Immersed Boundary Method for Simulating Fluid Structure Interaction With Complex 3D Rigid Bodies","volume":"227","year":"2008","journal-title":"J. Comput. Phys."},{"issue":"2","key":"2023051200040202700_bib21","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1007\/s10439-009-9807-x","article-title":"High-Resolution Fluid\u2013Structure Interaction Simulations of Flow Through a Bi-Leaflet Mechanical Heart Valve in an Anatomic Aorta","volume":"38","year":"2010","journal-title":"Ann. Biomed. Eng."},{"issue":"11","key":"2023051200040202700_bib22","article-title":"The Role of Shape and Heart Rate on the Performance of the Left Ventricle","volume":"137","year":"2015","journal-title":"ASME J. Biomech. Eng."},{"key":"2023051200040202700_bib23","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1016\/j.compfluid.2013.02.017","article-title":"A Parallel Overset-Curvilinear-Immersed Boundary Framework for Simulating Complex 3D Incompressible Flows","volume":"77","year":"2013","journal-title":"Comput. Fluids"},{"key":"2023051200040202700_bib24","doi-asserted-by":"crossref","first-page":"105378","DOI":"10.1016\/j.compfluid.2022.105378","article-title":"A Parallel Dynamic Overset Grid Framework for Immersed Boundary Methods","volume":"239","year":"2022","journal-title":"Comput. Fluids"},{"issue":"2","key":"2023051200040202700_bib25","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1016\/j.jcp.2005.01.020","article-title":"A Hybrid Cartesian\/Immersed Boundary Method for Simulating Flows With 3D, Geometrically Complex, Moving Bodies","volume":"207","year":"2005","journal-title":"J. Comput. Phys."},{"key":"2023051200040202700_bib26","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/j.jcp.2016.11.033","article-title":"A Newton\u2013Krylov Method With an Approximate Analytical Jacobian for Implicit Solution of Navier\u2013Stokes Equations on Staggered Overset-Curvilinear Grids With Immersed Boundaries","volume":"331","year":"2017","journal-title":"J. Comput. Phys."},{"issue":"2","key":"2023051200040202700_bib27","doi-asserted-by":"crossref","first-page":"1782","DOI":"10.1016\/j.jcp.2007.02.017","article-title":"A Numerical Method for Solving the 3D Unsteady Incompressible Navier\u2013Stokes Equations in Curvilinear Domains With Complex Immersed Boundaries","volume":"225","year":"2007","journal-title":"J. Comput. Phys."},{"key":"2023051200040202700_bib28","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.jbiomech.2017.06.005","article-title":"On the Choice of Outlet Boundary Conditions for Patient-Specific Analysis of Aortic Flow Using Computational Fluid Dynamics","volume":"60","year":"2017","journal-title":"J. Biomech."},{"issue":"1","key":"2023051200040202700_bib29","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1115\/1.1835367","article-title":"Single-Step Stereolithography of Complex Anatomical Models for Optical Flow Measurements","volume":"127","year":"2005","journal-title":"ASME J. Biomech. Eng."},{"issue":"-1","key":"2023051200040202700_bib30","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1017\/S0022112005005550","article-title":"Three-Dimensional Filling Flow Into a Model Left Ventricle","volume":"539","year":"2005","journal-title":"J. Fluid Mech."},{"issue":"1","key":"2023051200040202700_bib31","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1080\/10255842.2010.485987","article-title":"Intraventricular Vortex Flow Changes in the Infarcted Left Ventricle: Numerical Results in an Idealised 3D Shape","volume":"14","year":"2011","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"issue":"8","key":"2023051200040202700_bib32","doi-asserted-by":"crossref","first-page":"1790","DOI":"10.1007\/s10439-012-0540-5","article-title":"Describing the Highly Three Dimensional Right Ventricle Flow","volume":"40","year":"2012","journal-title":"Ann. Biomed. Eng."},{"key":"2023051200040202700_bib33","volume-title":"Mathematical and Computer Modeling of Physiological Systems","year":"1991"},{"issue":"2","key":"2023051200040202700_bib34","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1161\/01.CIR.37.2.149","article-title":"Systolic Time Intervals in Heart Failure in Man","volume":"37","year":"1968","journal-title":"Circulation"},{"issue":"1","key":"2023051200040202700_bib35","first-page":"1","article-title":"Patient-Specific Cfd Simulation of Intraventricular Haemodynamics Based on 3D Ultrasound Imaging","volume":"15","year":"2016","journal-title":"Biomed. Eng. Online"},{"issue":"10","key":"2023051200040202700_bib36","doi-asserted-by":"crossref","first-page":"1111","DOI":"10.1002\/fld.1650071008","article-title":"On Pressure Boundary Conditions for the Incompressible Navier-Stokes Equations","volume":"7","year":"1987","journal-title":"Int. J. Numer. Methods Fluids"},{"issue":"29\u201332","key":"2023051200040202700_bib37","first-page":"3776","article-title":"Outflow Boundary Conditions for Three-Dimensional Finite Element Modeling of Blood Flow and Pressure in Arteries","volume":"195","year":"2006","journal-title":"Comput. Methods Appl. Mech. Eng."},{"issue":"2","key":"2023051200040202700_bib38","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1111\/j.1440-1681.2008.05099.x","article-title":"Fluid Mechanics of Artificial Heart Valves","volume":"36","year":"2009","journal-title":"Clin. Exp. Pharmacol. Physiol."},{"issue":"6","key":"2023051200040202700_bib39","doi-asserted-by":"crossref","first-page":"067105","DOI":"10.1063\/1.2743261","article-title":"Vorticity Dynamics of a Bileaflet Mechanical Heart Valve in an Axisymmetric Aorta","volume":"19","year":"2007","journal-title":"Phys. Fluids"},{"key":"2023051200040202700_bib40","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.jcp.2012.08.036","article-title":"Fluid\u2013Structure Interaction of an Aortic Heart Valve Prosthesis Driven by an Animated Anatomic Left Ventricle","volume":"244","year":"2013","journal-title":"J. Comput. Phys."},{"key":"2023051200040202700_bib41","article-title":"Eddies, Stream, and Convergence Zones in Turbulent Flows","year":"1988","journal-title":"Center for Turbulence Research, Stanford"},{"issue":"5","key":"2023051200040202700_bib42","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1046\/j.1525-1594.2001.025005341.x","article-title":"Assessment of Hemolysis Related Quantities in a Microaxial Blood Pump by Computational Fluid Dynamics","volume":"25","year":"2001","journal-title":"Artif. Organs"},{"issue":"2","key":"2023051200040202700_bib43","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1007\/s10439-007-9411-x","article-title":"Characterization of Hemodynamic Forces Induced by Mechanical Heart Valves: Reynolds Vs. viscous Stresses","volume":"36","year":"2008","journal-title":"Ann. Biomed. Eng."},{"issue":"2","key":"2023051200040202700_bib44","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1007\/BF02648048","article-title":"Fluid Mechanics of Arterial Stenosis: Relationship to the Development of Mural Thrombus","volume":"25","year":"1997","journal-title":"Ann. Biomed. Eng."},{"issue":"6","key":"2023051200040202700_bib45","doi-asserted-by":"crossref","first-page":"1127","DOI":"10.1007\/s10237-013-0469-0","article-title":"A Novel Mathematical Model of Activation and Sensitization of Platelets Subjected to Dynamic Stress Histories","volume":"12","year":"2013","journal-title":"Biomech. Model. Mechanobiol."},{"issue":"4","key":"2023051200040202700_bib46","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1016\/S0022-5223(19)43063-8","article-title":"The Significance of Intermittent Regurgitation in Aortic Valve Prostheses","volume":"54","year":"1967","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"2023051200040202700_bib47","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.medengphy.2018.07.013","article-title":"The Influence of Bileaflet Prosthetic Aortic Valve Orientation on the Blood Flow Patterns in the Ascending Aorta","volume":"60","year":"2018","journal-title":"Med. Eng. Phys."},{"issue":"20","key":"2023051200040202700_bib48","doi-asserted-by":"crossref","first-page":"1133","DOI":"10.1056\/NEJM198011133032001","article-title":"Effect of Age on the Response of the Left Ventricular Ejection Fraction to Exercise","volume":"303","year":"1980","journal-title":"New Engl. J. Med."},{"issue":"Suppl_1","key":"2023051200040202700_bib49","first-page":"S165","article-title":"Mri Myocardial Motion and Fiber Tracking: A Confirmation of Knowledge From Different Imaging Modalities","volume":"29","year":"2006","journal-title":"Eur. J. Cardio-Thorac. Surg."}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/144\/10\/101008\/6880467\/bio_144_10_101008.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/144\/10\/101008\/6880467\/bio_144_10_101008.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,12]],"date-time":"2023-05-12T00:04:53Z","timestamp":1683849893000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/144\/10\/101008\/1140397\/The-Effects-of-Implantation-Orientation-of-a"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,12]]},"references-count":49,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2022,10,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4054411","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,12]]},"article-number":"101008"}}