{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T16:11:29Z","timestamp":1781107889132,"version":"3.54.1"},"reference-count":91,"publisher":"ASME International","issue":"2","license":[{"start":{"date-parts":[[2024,12,11]],"date-time":"2024-12-11T00:00:00Z","timestamp":1733875200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.asme.org\/publications-submissions\/publishing-information\/legal-policies"}],"content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Tremor is a rhythmic, involuntary oscillatory movement that severely affects some aspects of a patient's daily life. The use of wearable tremor-suppressing orthoses has become an effective, noninvasive treatment method for controlling tremors. This article summarizes recent developments in upper limb tremor suppression orthoses, aiming to provide a foundation for future research. By analyzing the working mechanisms, degrees-of-freedom (DOFs), weight, and tremor suppression effectiveness of various types of orthoses, the following conclusions are drawn: We found that differences in the working mechanism and the number of suppression directions are related to the weight of the device; weight, in turn, is a major factor affecting the comfort of the orthoses; and the combination of the number and weight of the damping direction affects the effect of the damping equipment. Balancing these three factors should be a key focus of future research. Moreover, researchers are placing greater emphasis on the comfort of the wearer during the development of these orthoses.<\/jats:p>","DOI":"10.1115\/1.4066968","type":"journal-article","created":{"date-parts":[[2024,10,23]],"date-time":"2024-10-23T16:03:57Z","timestamp":1729699437000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":2,"title":["Designs of Upper Limb Tremor Suppression Orthoses: Efficacy and Wearer's Comfort"],"prefix":"10.1115","volume":"19","author":[{"given":"MoYan","family":"ChiGan","sequence":"first","affiliation":[{"name":"School of Mechanical Engineering, Shaanxi University of Technology , Hanzhong 723000, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manlong","family":"Chen","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, Shaanxi University of Technology , Hanzhong 723000, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Min","family":"Jing","sequence":"additional","affiliation":[{"name":"School of Mechanical Engineering, Shaanxi University of Technology , Hanzhong 723000, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"33","published-online":{"date-parts":[[2024,12,11]]},"reference":[{"issue":"S3","key":"2025012014242102200_bib1","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1002\/mds.870131303","article-title":"Consensus Statement of the Movement Disorder Society on Tremor","volume":"13","year":"2008","journal-title":"Mov. Disord."},{"issue":"6","key":"2025012014242102200_bib2","doi-asserted-by":"crossref","first-page":"1096","DOI":"10.1002\/mds.23579","article-title":"Milestones in Tremor Research","volume":"26","year":"2011","journal-title":"Mov. Disord."},{"issue":"11","key":"2025012014242102200_bib3","doi-asserted-by":"crossref","first-page":"856","DOI":"10.1212\/01.wnl.0000325564.38165.d1","article-title":"Historical Underpinnings of the Term Essential Tremor in the Late 19th Century","volume":"71","year":"2008","journal-title":"Neurology"},{"issue":"1","key":"2025012014242102200_bib4","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1002\/mds.27121","article-title":"Consensus Statement on the Classification of Tremors. From the Task Force on Tremor of the International Parkinson and Movement Disorder Society","volume":"33","year":"2018","journal-title":"Mov. Disord."},{"issue":"12","key":"2025012014242102200_bib5","doi-asserted-by":"crossref","first-page":"2052","DOI":"10.1002\/mds.21157","article-title":"Report From a U.S. conference on Essential Tremor","volume":"21","year":"2006","journal-title":"Mov. Disord."},{"issue":"3","key":"2025012014242102200_bib6","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1016\/S1474-4422(19)30400-4","article-title":"\u03b2-Adrenoreceptors and the Risk of Parkinson's Disease","volume":"19","year":"2020","journal-title":"Lancet Neurol."},{"key":"2025012014242102200_bib7","doi-asserted-by":"crossref","first-page":"259","DOI":"10.5334\/tohm.198","article-title":"How Many People in the USA Have Essential Tremor? Deriving a Population Estimate Based on Epidemiological Data","volume":"4","year":"2014","journal-title":"Tremor Other Hyperkinetic Mov."},{"key":"2025012014242102200_bib8","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.spen.2018.02.002","article-title":"Tremors: Essential Tremor and Beyond","volume":"25","year":"2018","journal-title":"Semin. Pediatr. Neurol."},{"issue":"962","key":"2025012014242102200_bib9","doi-asserted-by":"crossref","first-page":"756","DOI":"10.1136\/pgmj.2005.032979","article-title":"Differential Diagnosis of Common Tremor Syndromes","volume":"81","year":"2005","journal-title":"Postgrad. Med. J."},{"issue":"9","key":"2025012014242102200_bib10","first-page":"678","article-title":"My Hands Shake\u2013Classification and Treatment of Tremor","volume":"38","year":"2009","journal-title":"Aust. Fam. Physician"},{"issue":"4","key":"2025012014242102200_bib11","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1080\/14737175.2018.1445526","article-title":"Surgical Treatments for Essential Tremor","volume":"18","year":"2018","journal-title":"Expert Rev. Neurother."},{"issue":"4","key":"2025012014242102200_bib12","doi-asserted-by":"crossref","first-page":"99","DOI":"10.3390\/bios11040099","article-title":"Medical Devices for Tremor Suppression: Current Status and Future Directions","volume":"11","year":"2021","journal-title":"Biosensors"},{"issue":"19","key":"2025012014242102200_bib13","doi-asserted-by":"crossref","first-page":"1752","DOI":"10.1212\/WNL.0b013e318236f0fd","article-title":"Evidence-Based Guideline Update: Treatment of Essential Tremor","volume":"77","year":"2011","journal-title":"Neurology"},{"issue":"12","key":"2025012014242102200_bib14","doi-asserted-by":"crossref","first-page":"1587","DOI":"10.1212\/WNL.39.12.1587","article-title":"Acute and Chronic Effects of Propranolol and Primidone in Essential Tremor","volume":"39","year":"1989","journal-title":"Neurology"},{"issue":"1132","key":"2025012014242102200_bib15","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1136\/postgradmedj-2019-136647","article-title":"Treatment of Essential Tremor: Current Status","volume":"96","year":"2020","journal-title":"Postgrad. Med. J."},{"issue":"9","key":"2025012014242102200_bib16","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1592\/phco.23.10.1105.32750","article-title":"Essential Tremor: Diagnosis and Treatment","volume":"23","year":"2003","journal-title":"Pharmacotherapy"},{"issue":"7","key":"2025012014242102200_bib17","doi-asserted-by":"crossref","first-page":"950","DOI":"10.1002\/mds.27700","article-title":"MDS Evidence-Based Review of Treatments for Essential Tremor","volume":"34","year":"2019","journal-title":"Mov. Disord."},{"issue":"2","key":"2025012014242102200_bib18","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1016\/S1474-4422(10)70322-7","article-title":"Treatment of Patients With Essential Tremor","volume":"10","year":"2011","journal-title":"Lancet Neurol."},{"issue":"3","key":"2025012014242102200_bib19","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1007\/s11910-022-01185-8","article-title":"Essential Tremor\u2014Do We Have Better Therapeutics? A Review of Recent Advances and Future Directions","volume":"22","year":"2022","journal-title":"Curr. Neurol. Neurosci. Rep."},{"issue":"4","key":"2025012014242102200_bib20","doi-asserted-by":"crossref","first-page":"1603","DOI":"10.1007\/s13311-020-00899-2","article-title":"Managing Essential Tremor","volume":"17","year":"2020","journal-title":"Neurotherapeutics"},{"issue":"1","key":"2025012014242102200_bib21","doi-asserted-by":"crossref","first-page":"78","DOI":"10.3390\/life13010078","article-title":"Diagnosis and Treatment of Tremor in Parkinson Disease Using Mechanical Devices","volume":"13","year":"2022","journal-title":"Life"},{"key":"2025012014242102200_bib22","doi-asserted-by":"crossref","first-page":"226199","DOI":"10.1109\/ACCESS.2020.3045023","article-title":"Tremor Suppression With Mechanical Vibration Stimulation","volume":"8","year":"2020","journal-title":"IEEE Access"},{"issue":"2","key":"2025012014242102200_bib23","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1007\/BF02368521","article-title":"Attenuation of Pathological Tremors by Functional Electrical Stimulation. I: Method","volume":"20","year":"1992","journal-title":"Ann. Biomed. Eng."},{"issue":"11","key":"2025012014242102200_bib24","doi-asserted-by":"crossref","first-page":"7543","DOI":"10.1109\/LRA.2023.3316607","article-title":"Multimodal Tremor Suppression of the Wrist Using FES and Electric Motors\u2013A Simulation Study","volume":"8","year":"2023","journal-title":"IEEE Rob. Autom. Lett."},{"issue":"1","key":"2025012014242102200_bib25","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1109\/TNSRE.2008.2008288","article-title":"The WalkTrainer\u2014A New Generation of Walking Reeducation Device Combining Orthoses and Muscle Stimulation","volume":"17","year":"2009","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"issue":"10","key":"2025012014242102200_bib26","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1016\/S0025-6196(12)61721-2","article-title":"Treatment of Essential Tremor With Methazolamide","volume":"66","year":"1991","journal-title":"Mayo Clin. Proc."},{"issue":"S3","key":"2025012014242102200_bib27","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1002\/mds.870131316","article-title":"Pharmacologic Treatment of Tremor","volume":"13","year":"2008","journal-title":"Mov. Disord."},{"key":"2025012014242102200_bib28","first-page":"2922","article-title":"Estimation of Instantaneous Tremor Parameters for FES-Based Tremor Suppression","volume-title":"IEEE International Conference on Robotics and Automation","year":"2010"},{"issue":"4","key":"2025012014242102200_bib29","doi-asserted-by":"crossref","first-page":"1133","DOI":"10.1007\/s10439-016-1765-5","article-title":"Fundamental Principles of Tremor Propagation in the Upper Limb","volume":"45","year":"2017","journal-title":"Ann. Biomed. Eng."},{"key":"2025012014242102200_bib30","unstructured":"Fu, H., 2022, \u201cDesign and Motion Planning of 7-DOF Anthropomorphic Prosthetic Arm Based on Spherical Parallel Mechanism,\u201d M.D. dissertation, Huazhong University of Science and Technology, Wuhan, Hu Bei."},{"key":"2025012014242102200_bib31","unstructured":"Hua, G., 2021, \u201cResearch on Key Technology of Intelligent Upper Limb Rehabilitation Robot and Its Trajectory Planning,\u201d M.D. dissertation, Guangxi University of Science and Technology, Liuzhou, Guang Xi.https:\/\/globethesis.com\/?t=2428330611472324"},{"key":"2025012014242102200_bib32","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1109\/ICORR.2009.5209630","article-title":"Mechanical Designs of Active Upper-Limb Exoskeleton Robots: State-of-the-Art and Design Difficulties","volume-title":"2009 IEEE International Conference on Rehabilitation Robotics","year":"2009"},{"issue":"11","key":"2025012014242102200_bib33","doi-asserted-by":"crossref","first-page":"2700","DOI":"10.1016\/j.clinph.2020.08.010","article-title":"Distribution of Tremor Among the Major Degrees of Freedom of the Upper Limb in Subjects With Essential Tremor","volume":"131","year":"2020","journal-title":"Clin. Neurophysiol."},{"key":"2025012014242102200_bib34","first-page":"6679","article-title":"Upper-Limb Tremor Suppression With a 7DOF Exoskeleton Power-Assist Robot","volume-title":"EMBC","year":"2013"},{"issue":"4","key":"2025012014242102200_bib35","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1016\/j.hcl.2013.08.001","article-title":"Skeletal Anatomy of the Hand","volume":"29","year":"2013","journal-title":"Hand Clin."},{"issue":"3","key":"2025012014242102200_bib36","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/j.hcl.2008.03.010","article-title":"Anatomy and Pathomechanics of the Thumb","volume":"24","year":"2008","journal-title":"Hand Clin."},{"issue":"8","key":"2025012014242102200_bib37","article-title":"Simulated Tremor Propagation in the Upper Limb: From Muscle Activity to Joint Displacement","volume":"141","year":"2019","journal-title":"ASME J. Biomech. Eng."},{"key":"2025012014242102200_bib38","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.clinph.2022.07.001","article-title":"Distribution of Tremorogenic Activity Among the Major Superficial Muscles of the Upper Limb in Persons With Essential Tremor","volume":"142","year":"2022","journal-title":"Clin. Neurophysiol."},{"issue":"4","key":"2025012014242102200_bib39","first-page":"283","article-title":"A Comprehensive Review of Fundamental Theory and Methodology for Tremor Suppression of Human Arm Based on Robotic Exoskeleton Technology","volume":"7","year":"2012","journal-title":"CAAI Trans. Intell. Syst."},{"issue":"7","key":"2025012014242102200_bib40","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1109\/10.686791","article-title":"THAKOR N V. Adaptive Cancelling of Physiological Tremor for Improved Precision in Microsurgery","volume":"45","year":"1998","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"2025012014242102200_bib41","first-page":"2847","article-title":"Bandlimited Multiple Fourier Linear Combiner for Real-Time Tremor Compensation","volume":"2007","year":"2007","journal-title":"Annu. Int. Conf. IEEE Eng. Med. Biol. Soc."},{"key":"2025012014242102200_bib42","doi-asserted-by":"crossref","first-page":"2271","DOI":"10.1109\/ROBOT.2005.1570451","article-title":"Rehabilitation Robotics: A Wearable Exo-Skeleton for Tremor Assessment and Suppression","volume-title":"Proceedings of the 2005 IEEE International Conference on Robotics and Automation","year":"2005"},{"issue":"26","key":"2025012014242102200_bib43","first-page":"4837","article-title":"Application of Shifted Band-Limited Multiple Fourier Linear Combiner in Pre-Estimation and Filtering of Human Tremor","volume":"15","year":"2011","journal-title":"J. Clin. Rehabil. Tissue Eng. Res."},{"key":"2025012014242102200_bib44","first-page":"2874","article-title":"Preliminary Assessment of the Safety of a Fault-Tolerant Control-Based Wearable Tremor Suppression Glove","volume-title":"EMBC","year":"2022"},{"key":"2025012014242102200_bib45","doi-asserted-by":"crossref","first-page":"2856","DOI":"10.1109\/TNSRE.2022.3211450","article-title":"Real-Time Performance Assessment of High-Order Tremor Estimators Used in a Wearable Tremor Suppression Device","volume":"30","year":"2022","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"issue":"2","key":"2025012014242102200_bib46","doi-asserted-by":"crossref","first-page":"2846","DOI":"10.1109\/LRA.2021.3062592","article-title":"Analysis of the Effect of Common Disturbances on the Safety of a Wearable Tremor Suppression Device","volume":"6","year":"2021","journal-title":"IEEE Rob. Autom. Lett."},{"key":"2025012014242102200_bib47","doi-asserted-by":"crossref","first-page":"680011","DOI":"10.3389\/fneur.2021.680011","article-title":"Wearable Devices for Assessment of Tremor","volume":"12","year":"2021","journal-title":"Front. Neurol."},{"key":"2025012014242102200_bib48","unstructured":"Wei, X., 2016, \u201cResearch on Functional Electrical Stimulation System for Suppressing Pathological Tremor of Upper Limb,\u201d M.D. dissertation, Harbin Institute of Technology, Harbin, Heilongjiang."},{"key":"2025012014242102200_bib49","doi-asserted-by":"crossref","first-page":"700600","DOI":"10.3389\/fneur.2021.700600","article-title":"A Review on Wearable Technologies for Tremor Suppression","volume":"12","year":"2021","journal-title":"Front. Neurol."},{"issue":"9","key":"2025012014242102200_bib50","doi-asserted-by":"crossref","first-page":"206","DOI":"10.3390\/act10090206","article-title":"Towards Essential Hand Tremor Suppression Via Pneumatic Artificial Muscles","volume":"10","year":"2021","journal-title":"Actuators"},{"issue":"9","key":"2025012014242102200_bib51","doi-asserted-by":"crossref","first-page":"2846","DOI":"10.1109\/TBME.2021.3080622","article-title":"Design and Preliminary Performance Assessment of a Wearable Tremor Suppression Glove","volume":"68","year":"2021","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"2025012014242102200_bib52","doi-asserted-by":"crossref","first-page":"2684","DOI":"10.1109\/TNSRE.2021.3135497","article-title":"A Layer Jamming Soft Glove for Hand Tremor Suppression","volume":"29","year":"2021","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"2025012014242102200_bib53","first-page":"29","article-title":"Voluntary-Driven Elbow Orthosis With Speed-Controlled Tremor Suppression","volume":"4","year":"2016","journal-title":"Front. Bioeng. Biotechnol."},{"key":"2025012014242102200_bib54","unstructured":"Yang, S., 2022, \u201cResearch on Dynamic Vibration Absorber for Inhibiting Human Upper Forearm Tremor,\u201d M.D. dissertation, Xi'an University of Architecture and Technology, Xi'an, Shaan Xi."},{"issue":"8","key":"2025012014242102200_bib55","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1080\/03091902.2021.1936673","article-title":"Design and Fabrication of a Novel Passive Hand Tremor Attenuator","volume":"45","year":"2021","journal-title":"J. Med. Eng. Technol."},{"issue":"4","key":"2025012014242102200_bib56","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1080\/03091902.2020.1759708","article-title":"Hand Tremor Suppression Device for Patients Suffering From Parkinson's Disease","volume":"44","year":"2020","journal-title":"J. Med. Eng. Technol."},{"issue":"1","key":"2025012014242102200_bib57","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1186\/s12984-020-00673-7","article-title":"Design of a Lightweight Passive Orthosis for Tremor Suppression","volume":"17","year":"2020","journal-title":"J. NeuroEng. Rehabil."},{"key":"2025012014242102200_bib58","unstructured":"Yi, A., 2019, \u201cDevelopment of Exoskeletons for Pathological Tremor Suppression of Wrist and Hand,\u201d M.D. dissertation, Shanghai Jiao Tong University, Shang Hai."},{"issue":"5","key":"2025012014242102200_bib59","doi-asserted-by":"crossref","first-page":"923","DOI":"10.1007\/s11517-017-1742-7","article-title":"Vib-Bracelet: A Passive Absorber for Attenuating Forearm Tremor","volume":"56","year":"2018","journal-title":"Med. Biol. Eng. Comput."},{"issue":"6","key":"2025012014242102200_bib60","doi-asserted-by":"crossref","first-page":"3693","DOI":"10.1109\/LRA.2023.3270747","article-title":"Jamming Enabled Variable Stiffness Wrist Exoskeleton for Tremor Suppression","volume":"8","year":"2023","journal-title":"IEEE Rob. Autom. Lett."},{"key":"2025012014242102200_bib61","doi-asserted-by":"crossref","first-page":"107674","DOI":"10.1016\/j.ymssp.2021.107674","article-title":"A Wearable Elbow Exoskeleton for Tremor Suppression Equipped With Rotational Semi-Active Actuator","volume":"157","year":"2021","journal-title":"Mech. Syst. Signal Process."},{"key":"2025012014242102200_bib62","first-page":"1115","article-title":"A Novel Exoskeleton System Based on Magnetorheological Fluid for Tremor Suppression of Wrist Joints","volume-title":"ICORR","year":"2019"},{"key":"2025012014242102200_bib63","doi-asserted-by":"crossref","first-page":"622535","DOI":"10.3389\/fnhum.2021.622535","article-title":"Tremor-Suppression Orthoses for the Upper Limb: Current Developments and Future Challenges","volume":"15","year":"2021","journal-title":"Front. Human Neurosci."},{"issue":"2","key":"2025012014242102200_bib64","doi-asserted-by":"crossref","first-page":"1143","DOI":"10.1109\/TMECH.2020.2972884","article-title":"Tremor-Active Controller for Dielectric Elastomer-Based Pathological Tremor Suppression","volume":"25","year":"2020","journal-title":"IEEE\/ASME Trans. Mechatron."},{"issue":"1","key":"2025012014242102200_bib65","doi-asserted-by":"crossref","first-page":"012056","DOI":"10.1088\/1757-899X\/577\/1\/012056","article-title":"Parkinson's Tremor Suppression Using Active Vibration Control Method","volume":"577","year":"2019","journal-title":"IOP Conf. Ser.: Mater. Sci. Eng."},{"key":"2025012014242102200_bib66","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.robot.2016.12.009","article-title":"Design and Validation of a Novel Mechatronic Transmission System for a Wearable Tremor Suppression Device","volume":"91","year":"2017","journal-title":"Rob. Auton. Syst."},{"key":"2025012014242102200_bib67","first-page":"1","article-title":"Development and Validation of a Finger Tremor Simulator","volume-title":"CCECE","year":"2018"},{"key":"2025012014242102200_bib68","first-page":"640","article-title":"Development of a Wearable Tremor Suppression Glove","volume-title":"IEEE International Conference on Biomedical Robotics and Biomechatronics (Biorob)","year":"2018"},{"issue":"12","key":"2025012014242102200_bib69","doi-asserted-by":"crossref","first-page":"121008","DOI":"10.1115\/1.4047424","article-title":"Multibody Analysis and Control of a Full-Wrist Exoskeleton for Tremor Alleviation","volume":"142","year":"2020","journal-title":"ASME J. Biomech. Eng."},{"issue":"7","key":"2025012014242102200_bib70","doi-asserted-by":"crossref","first-page":"e2177","DOI":"10.1002\/stc.2177","article-title":"Parametric Study of an Enhanced Passive Absorber Used for Tremor Suppression","volume":"25","year":"2018","journal-title":"Struct. Control Health Monit."},{"key":"2025012014242102200_bib71","unstructured":"Li, J.-Q., 2011, \u201cResearch on Tremor Suppression Robot and Key Techniques for Pathological Tremor,\u201d M.D. dissertation, Harbin Institute of Technology, Harbin, Hei Long Jiang."},{"key":"2025012014242102200_bib72","first-page":"3140","article-title":"On the Use of an Active Wearable Exoskeleton for Tremor Suppression Via Biomechanical Loading","volume-title":"IEEE International Conference on Robotics and Automation","year":"2006"},{"issue":"1","key":"2025012014242102200_bib73","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1007\/BF02351012","article-title":"Tuned Vibration Absorber for Suppression of Rest Tremor in Parkinson's Disease","volume":"42","year":"2004","journal-title":"Med. Biol. Eng. Comput."},{"key":"2025012014242102200_bib74","unstructured":"MasoumiI, M. M., 2018, \u201cPassive Hand Tremor Attenuator: Magnetic Spring,\u201d M.D. dissertation, University of British Columbia, Vancouver, BC, Canada.10.14288\/1.0368769"},{"issue":"5","key":"2025012014242102200_bib75","first-page":"18","article-title":"A Type of Light Hand Exoskeleton Based on Linear Motor","volume":"35","year":"2019","journal-title":"Mach. Des. Res."},{"key":"2025012014242102200_bib76","article-title":"Wearable Tremor Reduction Device (TRD) for Human Hands and Arms","volume-title":"ASME","year":"2018"},{"key":"2025012014242102200_bib77","unstructured":"Tao, Y., 2012, \u201cDevelopment of Magnetorheological Fluid Damper for Pathological Tremor Suppression,\u201d M.D. dissertation, Harbin Institute of Technology, Harbin, Hei Long Jiang."},{"issue":"6","key":"2025012014242102200_bib78","first-page":"1133","article-title":"Research on Simulation and Optimal Design of a Miniature Magnetorheological Fluid Damper Used in Wearable Rehabilitation Training System","volume":"39","year":"2022","journal-title":"J. Biomed. Eng."},{"key":"2025012014242102200_bib79","article-title":"Modelling of a Magnetorheological Fluid Knee in a Prosthetic Leg","volume-title":"ASME","year":"2016"},{"key":"2025012014242102200_bib80","article-title":"Design and Experimental Analysis of a Biomedical Prosthetic Knee With Magnetorheological Fluid","volume-title":"ASME","year":"2015"},{"issue":"4","key":"2025012014242102200_bib81","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1089\/soro.2019.0194","article-title":"A Soft Exoskeleton for Tremor Suppression Equipped With Flexible Semiactive Actuator","volume":"8","year":"2021","journal-title":"Soft Rob."},{"issue":"1","key":"2025012014242102200_bib82","doi-asserted-by":"crossref","first-page":"21","DOI":"10.4103\/jmss.jmss_116_21","article-title":"Design and Fabrication of a Device for Reducing Hand Tremor in Parkinson Patients During Eating","volume":"13","year":"2023","journal-title":"J. Med. Signals Sens."},{"issue":"7","key":"2025012014242102200_bib83","doi-asserted-by":"crossref","first-page":"1315","DOI":"10.1007\/s11517-017-1769-9","article-title":"Design of a Noninvasive and Smart Hand Tremor Attenuation System With Active Control: A Simulation Study","volume":"56","year":"2018","journal-title":"Med. Biol. Eng. Comput."},{"key":"2025012014242102200_bib84","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/j.mechmachtheory.2018.04.009","article-title":"Modeling and Experimental Study of a Hand Tremor Suppression System","volume":"126","year":"2018","journal-title":"Mech. Mach. Theory"},{"issue":"3","key":"2025012014242102200_bib85","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1080\/03091902.2022.2134482","article-title":"Computational Study and Validation of a Novel Passive Hand Tremor Attenuator","volume":"47","year":"2023","journal-title":"J. Med. Eng. Technol."},{"key":"2025012014242102200_bib86","first-page":"165","article-title":"Research on the Tremor Suppression Test System for the Tremor Suppression Robot","year":"2012","journal-title":"Mach. Des. Manuf."},{"key":"2025012014242102200_bib87","unstructured":"Bo, Y., 2010, \u201cResearch on Control Strategy for The Wearable Tremor Suppression Rehabiltation Robotics,\u201d M.D. dissertation, Harbin Institute of Technology, Harbin, He Long Jiang."},{"issue":"11","key":"2025012014242102200_bib88","first-page":"139","article-title":"Magnetic Circuit Design and Mechanical Performance Study for a MR Damper","volume":"29","year":"2010","journal-title":"J. Vib. Shock"},{"key":"2025012014242102200_bib89","article-title":"On the Dynamics and Control of a Full Wrist Exoskeleton for Tremor Alleviation","volume-title":"ASME","year":"2019"},{"issue":"1","key":"2025012014242102200_bib90","doi-asserted-by":"crossref","first-page":"015013","DOI":"10.1088\/1361-665X\/abc062","article-title":"Design of Fiber-Reinforced Soft Bending Pneumatic Artificial Muscles for Wearable Tremor Suppression Devices","volume":"30","year":"2021","journal-title":"Smart Mater. Struct."},{"issue":"6","key":"2025012014242102200_bib91","doi-asserted-by":"crossref","first-page":"782","DOI":"10.1109\/TNSRE.2016.2602941","article-title":"A Magnetic Resonance Compatible Soft Wearable Robotic Glove for Hand Rehabilitation and Brain Imaging","volume":"25","year":"2017","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."}],"container-title":["Journal of Medical Devices"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/asmedigitalcollection.asme.org\/medicaldevices\/article-pdf\/19\/2\/020801\/7415465\/med_019_02_020801.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/asmedigitalcollection.asme.org\/medicaldevices\/article-pdf\/19\/2\/020801\/7415465\/med_019_02_020801.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,20]],"date-time":"2025-01-20T14:24:56Z","timestamp":1737383096000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/medicaldevices\/article\/19\/2\/020801\/1207608\/Designs-of-Upper-Limb-Tremor-Suppression-Orthoses"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,11]]},"references-count":91,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025,6,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4066968","relation":{},"ISSN":["1932-6181","1932-619X"],"issn-type":[{"value":"1932-6181","type":"print"},{"value":"1932-619X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,11]]},"article-number":"020801"}}