{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T17:47:19Z","timestamp":1785433639451,"version":"3.56.0"},"reference-count":52,"publisher":"ASME International","issue":"2","license":[{"start":{"date-parts":[[2025,1,3]],"date-time":"2025-01-03T00:00:00Z","timestamp":1735862400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.asme.org\/publications-submissions\/publishing-information\/legal-policies"}],"content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,2,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The aim of this work is to improve musculoskeletal-based models of the upper-limb wrench feasible set (WFS), i.e., the set of achievable maximal wrenches at the hand for applications in collaborative robotics and computer aided ergonomics. In particular, a recent method performing wrench capacity evaluation called the iterative convex hull method (ICHM) is upgraded in order to integrate nondislocation and compression limitation constraints at the glenohumeral (GH) joint not taken into account in the available models. Their effects on the amplitude of the force capacities at the hand, glenohumeral joint reaction forces and upper-limb muscles coordination in comparison to the original iterative convex hull method are investigated in silico. The results highlight the glenohumeral potential dislocation for the majority of elements of the wrench feasible set with the original iterative convex hull method and the fact that the modifications satisfy correctly stability constraints at the glenohumeral joint. Also, the induced muscles coordination pattern favors the action of stabilizing muscles, in particular the rotator-cuff muscles, and lowers that of known potential destabilizing ones according to the literature.<\/jats:p>","DOI":"10.1115\/1.4067329","type":"journal-article","created":{"date-parts":[[2024,12,5]],"date-time":"2024-12-05T07:53:32Z","timestamp":1733385212000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":3,"title":["Simulation Study of the Upper-Limb Isometric Wrench Feasible Set With Glenohumeral Joint Constraints"],"prefix":"10.1115","volume":"147","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8037-3522","authenticated-orcid":false,"given":"Nasser","family":"Rezzoug","sequence":"first","affiliation":[{"name":"Universit\u00e9 de Poitiers, CNRS, ISAE-ENSMA, Institut PPRIME , Poitiers F-86000, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antun","family":"Skuric","sequence":"additional","affiliation":[{"name":"Centre INRIA de l'Universit\u00e9 de Bordeaux , Talence 33405, France"},{"id":[{"id":"https:\/\/ror.org\/03tjcj052","id-type":"ROR","asserted-by":"publisher"}],"name":"Inria Bordeaux - Sud-Ouest Research Centre"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1875-2097","authenticated-orcid":false,"given":"Vincent","family":"Padois","sequence":"additional","affiliation":[{"name":"Centre INRIA de l'Universit\u00e9 de Bordeaux , Talence 33405, France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Daney","sequence":"additional","affiliation":[{"name":"Centre INRIA de l'Universit\u00e9 de Bordeaux , Talence 33405, France"},{"id":[{"id":"https:\/\/ror.org\/03tjcj052","id-type":"ROR","asserted-by":"publisher"}],"name":"Inria Bordeaux - Sud-Ouest Research Centre"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"33","published-online":{"date-parts":[[2025,1,3]]},"reference":[{"issue":"7","key":"2025010315491340100_bib1","doi-asserted-by":"crossref","first-page":"1912","DOI":"10.1109\/TBME.2013.2244889","article-title":"Estimating Physical Assistance Need Using a Musculoskeletal Model","volume":"60","year":"2013","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"2","key":"2025010315491340100_bib2","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1109\/LRA.2020.3043173","article-title":"Human Comfortability: Integrating Ergonomics and Muscular-Informed Metrics for Manipulability Analysis During Human-Robot Collaboration","volume":"6","year":"2021","journal-title":"IEEE Rob. Autom. Lett."},{"issue":"1","key":"2025010315491340100_bib3","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1109\/TRO.2015.2503726","article-title":"Minimal Assist-as-Needed Controller for Upper Limb Robotic Rehabilitation","volume":"32","year":"2016","journal-title":"IEEE Trans. Rob."},{"issue":"3\u20134","key":"2025010315491340100_bib4","first-page":"141","article-title":"Investigating the Role of the Shoulder Musculature During Maximum Unilateral Isometric Exertions","volume":"9","year":"2010","journal-title":"Occup. Ergon."},{"key":"2025010315491340100_bib5","volume-title":"Occupational Biomechanics","year":"2006"},{"key":"2025010315491340100_bib6","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.ergon.2016.11.011","article-title":"Human-Oriented Design of Collaborative Robots","volume":"57","year":"2017","journal-title":"Int. J. Ind. Ergon."},{"issue":"3","key":"2025010315491340100_bib7","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1504\/IJHFMS.2016.079705","article-title":"Experimental Assessment of the Quality of Ergonomic Indicators for Dynamic Systems Computed Using a Digital Human Model","volume":"5","year":"2016","journal-title":"Int. J. Human Factors Modell. Simul."},{"issue":"3","key":"2025010315491340100_bib8","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1080\/17452759.2010.504056","article-title":"A New Muscle Fatigue and Recovery Model and Its Ergonomics Application in Human Simulation","volume":"5","year":"2010","journal-title":"Virtual Phys. Prototyping"},{"key":"2025010315491340100_bib9","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1007\/978-3-319-41627-4","article-title":"Movement Variability and Digital Human Models: Development of a Demonstrator Taking the Effects of Muscular Fatigue Into Account","volume-title":"Advances in Applied Digital Human Modeling and Simulation","author":"Duffy","year":"2017"},{"key":"2025010315491340100_bib10","doi-asserted-by":"crossref","first-page":"103464","DOI":"10.1016\/j.apergo.2021.103464","article-title":"Evidence of Movement Variability Patterns During a Repetitive Pointing Task Until Exhaustion","volume":"96","year":"2021","journal-title":"Appl. Ergon."},{"issue":"2","key":"2025010315491340100_bib11","first-page":"79","article-title":"A Normative Database of Isokinetic Upper-Extremity Joint Strengths: Towards the Evaluation of Dynamic Human Performance","volume":"13","year":"2001","journal-title":"Biomed. Eng.: Appl., Basis Commun."},{"issue":"Suppl 1","key":"2025010315491340100_bib12","first-page":"2260","article-title":"Elbow Torque Ellipses: Investigation of the Mutual Influences of Rotation, Flexion, and Extension Torques","volume":"41","year":"2012","journal-title":"Work"},{"issue":"5","key":"2025010315491340100_bib13","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/0268-0033(93)90031-C","article-title":"Isometric Strength in Flexors, Abductors, and External Rotators of the Shoulder","volume":"8","year":"1993","journal-title":"Clinical Biomech."},{"key":"2025010315491340100_bib14","doi-asserted-by":"crossref","first-page":"103415","DOI":"10.1016\/j.apergo.2021.103415","article-title":"A Comparison Between Measured Female Linear Arm Strengths and Estimates From the 3D Static Strength Prediction Program (3DSSPP)","volume":"94","year":"2021","journal-title":"Appl. Ergon."},{"issue":"3","key":"2025010315491340100_bib15","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1177\/1758573217748643","article-title":"Normative Values of Isometric Elbow Strength in Healthy Adults: A Systematic Review","volume":"10","year":"2018","journal-title":"Shoulder Elbow"},{"key":"2025010315491340100_bib16","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1016\/j.apergo.2016.09.012","article-title":"The \u2018Arm Force Field\u2019 Method to Predict Manual Arm Strength Based on Only Hand Location and Force Direction","volume":"59","year":"2017","journal-title":"Appl. Ergon."},{"key":"2025010315491340100_bib17","first-page":"261","article-title":"Isometric Elbow Strength in Normal Individuals","volume":"222","year":"1987","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"1\u20132","key":"2025010315491340100_bib18","first-page":"101","article-title":"Human Muscle Strength Definitions, Measurement, and Usage: Part i\u2013Guidelines for the Practitioner","volume":"22","year":"1998","journal-title":"Int. J. Ind. Ergon."},{"issue":"1\u20132","key":"2025010315491340100_bib19","first-page":"123","article-title":"Human Muscle Strength Definitions, Measurement, and Usage: Part ii-the Scientific Basis (Knowledge Base) for the Guide","volume":"22","year":"1998","journal-title":"Int. J. Ind. Ergon."},{"issue":"2","key":"2025010315491340100_bib20","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1504\/IJHFMS.2012.051092","article-title":"Maximum Elbow Joint Torques for Digital Human Models","volume":"3","year":"2012","journal-title":"Int. J. Human Factors Modell. Simul."},{"issue":"2","key":"2025010315491340100_bib21","doi-asserted-by":"crossref","first-page":"5206","DOI":"10.1109\/LRA.2022.3155374","article-title":"On-Line Feasible Wrench Polytope Evaluation Based on Human Musculoskeletal Models: An Iterative Convex Hull Method","volume":"7","year":"2022","journal-title":"IEEE Rob. Autom. Lett."},{"key":"2025010315491340100_bib22","first-page":"619","volume-title":"A Mathematical Approach to the Mechanical Capabilities of Limbs and Fingers","year":"2009"},{"issue":"4","key":"2025010315491340100_bib23","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1080\/10255842.2015.1042465","article-title":"Improving Anterior Deltoid Activity in a Musculoskeletal Shoulder Model \u2013 An Analysis of the Torque-Feasible Space at the Sternoclavicular Joint","volume":"19","year":"2016","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"2025010315491340100_bib24","doi-asserted-by":"crossref","first-page":"1265635","DOI":"10.3389\/frobt.2023.1265635","article-title":"Comparison of Strength Profile Representations Using Musculoskeletal Models and Their Applications in Robotics","volume":"10","year":"2024","journal-title":"Front. Rob. AI"},{"key":"2025010315491340100_bib25","first-page":"4533","article-title":"Real-Time Estimation of the Strength Capacity of the Upper Limb for Physical Human-Robot Collaboration","volume":"2021","year":"2021","journal-title":"Annu. Int. Conf. IEEE Eng. Med. Biol. Soc."},{"issue":"1","key":"2025010315491340100_bib26","doi-asserted-by":"crossref","first-page":"102","DOI":"10.3390\/biomechanics1010008","article-title":"Upper-Limb Isometric Force Feasible Set: Evaluation of Joint Torque-Based Models","volume":"1","year":"2021","journal-title":"Biomechanics"},{"issue":"12","key":"2025010315491340100_bib27","doi-asserted-by":"crossref","first-page":"3178","DOI":"10.1016\/j.jbiomech.2015.07.003","article-title":"Toward Isometric Force Capabilities Evaluation by Using a Musculoskeletal Model: Comparison With Direct Force Measurement","volume":"48","year":"2015","journal-title":"J. Biomech."},{"issue":"12","key":"2025010315491340100_bib28","doi-asserted-by":"crossref","first-page":"e0189406","DOI":"10.1371\/journal.pone.0189406","article-title":"Muscle Function in Glenohumeral Joint Stability During Lifting Task","volume":"12","year":"2017","journal-title":"Plos One"},{"issue":"1","key":"2025010315491340100_bib29","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1080\/14763141.2016.1216585","article-title":"Glenohumeral Contact Force During Flat and Topspin Tennis Forehand Drives","volume":"16","year":"2017","journal-title":"Sports Biomech."},{"key":"2025010315491340100_bib30","doi-asserted-by":"crossref","first-page":"110641","DOI":"10.1016\/j.jbiomech.2021.110641","article-title":"Glenohumeral Joint and Muscles Functions During a Lifting Task","volume":"126","year":"2021","journal-title":"J. Biomech."},{"issue":"1","key":"2025010315491340100_bib31","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/S1058-2746(09)80134-1","article-title":"Glenohumeral Stability From Concavity-Compression: A Quantitative Analysis","volume":"2","year":"1993","journal-title":"J. Shoulder Elbow Surg."},{"issue":"7","key":"2025010315491340100_bib32","doi-asserted-by":"crossref","first-page":"886","DOI":"10.1016\/j.clinbiomech.2008.04.004","article-title":"Experimental Evaluation of a Computational Shoulder Musculoskeletal Model","volume":"23","year":"2008","journal-title":"Clin. Biomech."},{"issue":"1","key":"2025010315491340100_bib33","doi-asserted-by":"crossref","first-page":"S32","DOI":"10.1016\/j.jse.2004.09.014","article-title":"Stability and Instability of the Glenohumeral Joint: The Role of Shoulder Muscles","volume":"14","year":"2005","journal-title":"J. Shoulder Elbow Surg."},{"issue":"1","key":"2025010315491340100_bib34","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1016\/S1058-2746(99)90059-9","article-title":"Use of Botulinum a Toxin in Irreducible Shoulder Dislocation Caused by Spasm of Pectoralis Major","volume":"8","year":"1999","journal-title":"J. Shoulder Elbow Surg."},{"issue":"5","key":"2025010315491340100_bib35","doi-asserted-by":"crossref","first-page":"051006","DOI":"10.1115\/1.4043035","article-title":"Spatial Dependency of Glenohumeral Joint Stability During Dynamic Unimanual and Bimanual Pushing and Pulling","volume":"141","year":"2019","journal-title":"ASME J. Biomech. Eng."},{"issue":"6","key":"2025010315491340100_bib36","doi-asserted-by":"crossref","first-page":"986","DOI":"10.1002\/jor.1100140620","article-title":"Kinematics of the Glenohumeral Joint: Influences of Muscle Forces, Ligamentous Constraints, and Articular Geometry","volume":"14","year":"1996","journal-title":"J. Orthop. Res."},{"key":"2025010315491340100_bib37","article-title":"Does Enforcing Glenohumeral Joint Stability Matter? a New Rapid Muscle Redundancy Solver Highlights the Importance of Non-Superficial Shoulder Muscles","volume-title":"PLos One","year":"2023"},{"issue":"10","key":"2025010315491340100_bib38","doi-asserted-by":"crossref","first-page":"3522","DOI":"10.3390\/app10103522","article-title":"EMG-Assisted Algorithm to Account for Shoulder Muscles co-Contraction in Overhead Manual Handling","volume":"10","year":"2020","journal-title":"Appl. Sci."},{"issue":"89","key":"2025010315491340100_bib39","doi-asserted-by":"crossref","first-page":"5670","DOI":"10.21105\/joss.05670","article-title":"Pycapacity: A Real-Time Task-Space Capacity Calculation Package for Robotics and Biomechanics","volume":"8","year":"2023","journal-title":"J. Open Source Software"},{"issue":"13","key":"2025010315491340100_bib40","doi-asserted-by":"crossref","first-page":"1445","DOI":"10.1080\/10255842.2014.916698","article-title":"Benchmarking of Dynamic Simulation Predictions in Two Software Platforms Using an Upper Limb Musculoskeletal Model","volume":"18","year":"2015","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"issue":"7","key":"2025010315491340100_bib41","doi-asserted-by":"crossref","first-page":"e1006223","DOI":"10.1371\/journal.pcbi.1006223","article-title":"Opensim: Simulating Musculoskeletal Dynamics and Neuromuscular Control to Study Human and Animal Movement","volume":"14","year":"2018","journal-title":"PLoS Comput. Biol."},{"issue":"6","key":"2025010315491340100_bib42","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1243\/0954411001535660","article-title":"Glenohumeral Contact Forces","volume":"214","year":"2000","journal-title":"Proc. Inst. Mech. Eng., Part H"},{"issue":"10","key":"2025010315491340100_bib43","doi-asserted-by":"crossref","first-page":"2139","DOI":"10.1016\/j.jbiomech.2006.10.037","article-title":"In Vivo Glenohumeral Contact Forces\u2013Measurements in the First Patient 7 Months Postoperatively","volume":"40","year":"2007","journal-title":"J. Biomech."},{"key":"2025010315491340100_bib44","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.clinbiomech.2018.03.006","article-title":"Analysis of Shoulder Compressive and Shear Forces During Functional Activities of Daily Life","volume":"54","year":"2018","journal-title":"Clin. Biomech."},{"issue":"15","key":"2025010315491340100_bib45","doi-asserted-by":"crossref","first-page":"3007","DOI":"10.1016\/j.jbiomech.2010.06.015","article-title":"Validation of the Delft Shoulder and Elbow Model Using in-Vivo Glenohumeral Joint Contact Forces","volume":"43","year":"2010","journal-title":"J. Biomech."},{"issue":"4","key":"2025010315491340100_bib46","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1682\/JRRD.2003.07.0349","article-title":"A Novel Cadaveric Model for Anterior-Inferior Shoulder Dislocation Using Forcible Apprehension Positioning","volume":"40","year":"2003","journal-title":"J. Rehabil. Res. Dev."},{"issue":"12","key":"2025010315491340100_bib47","doi-asserted-by":"crossref","first-page":"1840","DOI":"10.1016\/j.jbiomech.2009.05.035","article-title":"In Vivo Measurement of Shoulder Joint Loads During Activities of Daily Living","volume":"42","year":"2009","journal-title":"J. Biomech."},{"issue":"403 Suppl","key":"2025010315491340100_bib48","first-page":"S18","article-title":"Muscles May Contribute to Shoulder Dislocation and Stability","volume":"403","year":"2002","journal-title":"Clin. Orthop. Relat. Res."},{"key":"2025010315491340100_bib49","article-title":"Triangle\/Ray Intersection","year":"2024"},{"issue":"2","key":"2025010315491340100_bib50","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1097\/01.JAT.0000453141.39418.fb","article-title":"Upper Extremity Forces Generated During Activities of Daily Living: Implications for Patients Following Sternotomy","volume":"5","year":"2014","journal-title":"J. Acute Care Phys. Ther."},{"issue":"2","key":"2025010315491340100_bib51","doi-asserted-by":"crossref","first-page":"021024","DOI":"10.1115\/1.2903422","article-title":"Contributions of the Individual Muscles of the Shoulder to Glenohumeral Joint Stability During Abduction","volume":"130","year":"2008","journal-title":"ASME J. Biomech. Eng."},{"issue":"sup1","key":"2025010315491340100_bib52","first-page":"S210","article-title":"Dynamics Aware Cartesian Wrench Polytope Estimation Based on Human Musculoskeletal Models","volume":"26","year":"2023","journal-title":"Comput. Methods Biomech. Biomed. Eng."}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4067329\/7421148\/bio_147_02_024501.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/doi\/10.1115\/1.4067329\/7421148\/bio_147_02_024501.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,3]],"date-time":"2025-01-03T10:49:37Z","timestamp":1735901377000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/147\/2\/024501\/1210208\/Simulation-Study-of-the-Upper-Limb-Isometric"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,3]]},"references-count":52,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025,2,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4067329","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,3]]},"article-number":"024501"}}