{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T12:46:29Z","timestamp":1753879589490,"version":"3.41.2"},"reference-count":48,"publisher":"ASME International","issue":"8","license":[{"start":{"date-parts":[[2025,6,20]],"date-time":"2025-06-20T00:00:00Z","timestamp":1750377600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.asme.org\/publications-submissions\/publishing-information\/legal-policies"}],"content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,8,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Heart failure (HF) is a significant health threat, and the short-term percutaneous interventional left ventricular assist devices (PLVADs) play an important role in the management of it. However, studies on PLVAD blood flow patterns at varying rotational speeds are limited. Therefore, it is essential to explore the hemodynamic profiles of PLVADs under varying modes. A patient-specific model was developed, and the lumped-parameter model (LPM) was used as boundary conditions. The hemodynamic changes of PLVAD under pulsating flow (PF) and counterpulsating flow (CPF) were analyzed using computational fluid dynamics (CFD). Key parameters, including pressure, wall shear stress (WSS), oscillatory shear index (OSI), time-averaged wall shear stress (TAWSS), endothelial cell activation potential (ECAP), relative residence time (RRT), and velocity, were calculated and compared under continuous-flow (CF) condition. PLVAD support reduced afterload, and both pulsatile modes exhibited better pulsatility than CF, particularly the PF mode. In CPF mode, the native heart performed the least work, which may be more conducive to recovery. The trends for WSS, pressure, and velocity were similar across conditions, but their magnitudes varied. Overall, PLVAD support can increase TAWSS and decrease OSI, RRT, and ECAP. Although there was no significant difference in TAWSS and OSI among CF, PF, and CPF, we observed the smallest RRT for PF and the smallest ECAP for CPF. Hemodynamic data suggest that pulsatile patterns appear to reduce the risk of thrombosis and other complications compared to CF.<\/jats:p>","DOI":"10.1115\/1.4068910","type":"journal-article","created":{"date-parts":[[2025,6,20]],"date-time":"2025-06-20T23:53:50Z","timestamp":1750463630000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":0,"title":["Impact of Short-Term Percutaneous Interventional Left Ventricular Assist Devices Support Modes on Aortic Hemodynamics"],"prefix":"10.1115","volume":"147","author":[{"given":"Honglong","family":"Yu","sequence":"first","affiliation":[{"name":"School of Instrument Science and Opto-electronics Engineering, Hefei University of Technology , Hefei 230009, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuan","family":"He","sequence":"additional","affiliation":[{"name":"Anhui Provincial Joint Construction Key Laboratory of Biomimetic Medicine, Anhui Tongling Bionic Technology Co. Ltd. , Hefei 230093, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuehu","family":"Wu","sequence":"additional","affiliation":[{"name":"Anhui Provincial Joint Construction Key Laboratory of Biomimetic Medicine, Anhui Tongling Bionic Technology Co. Ltd. , Hefei 230093, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xuefeng","family":"Feng","sequence":"additional","affiliation":[{"name":"Anhui Provincial Joint Construction Key Laboratory of Biomimetic Medicine, Anhui Tongling Bionic Technology Co. Ltd. , Hefei 230093, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qilian","family":"Xie","sequence":"additional","affiliation":[{"name":"Anhui Provincial Joint Construction Key Laboratory of Biomimetic Medicine, Anhui Tongling Bionic Technology Co. Ltd. , Hefei 230093, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hu","family":"Peng","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, School of Instrument Science and Opto-electronics Engineering, Hefei University of Technology , Hefei 230009, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"33","published-online":{"date-parts":[[2025,6,20]]},"reference":[{"issue":"10","key":"2025070707060700300_bib1","doi-asserted-by":"crossref","first-page":"1015","DOI":"10.1001\/jama.2020.13310","article-title":"Heart Failure","volume":"324","year":"2020","journal-title":"JAMA"},{"issue":"36","key":"2025070707060700300_bib2","doi-asserted-by":"crossref","first-page":"3599","DOI":"10.1093\/eurheartj\/ehab368","article-title":"2021 ESC Guidelines for the Diagnosis and Treatment of Acute and Chronic Heart Failure","volume":"42","year":"2021","journal-title":"Eur. Heart J."},{"issue":"2","key":"2025070707060700300_bib3","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.healun.2010.12.001","article-title":"Third INTERMACS Annual Report: The Evolution of Destination Therapy in the United States","volume":"30","year":"2011","journal-title":"J. Heart Lung Transplant.: Off. Publ. Int. Soc. Heart Transplant."},{"issue":"4","key":"2025070707060700300_bib4","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1016\/j.healun.2010.01.011","article-title":"Clinical Management of Continuous-Flow Left Ventricular Assist Devices in Advanced Heart Failure","volume":"29","year":"2010","journal-title":"J. Heart Lung Transplant.: Off. Publ. Int. Soc. Heart Transplant."},{"issue":"6","key":"2025070707060700300_bib5","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1111\/aor.13112","article-title":"Bridging to a Long-Term Ventricular Assist Device With Short-Term Mechanical Circulatory Support","volume":"42","year":"2018","journal-title":"Artif. Organs"},{"issue":"10","key":"2025070707060700300_bib6","doi-asserted-by":"crossref","first-page":"1622","DOI":"10.1016\/j.amjcard.2016.02.038","article-title":"Effectiveness and Safety of the Impella 5.0 as a Bridge to Cardiac Transplantation or Durable Left Ventricular Assist Device","volume":"117","year":"2016","journal-title":"Am. J. Cardiol."},{"issue":"1","key":"2025070707060700300_bib7","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1097\/MAT.0000000000000309","article-title":"Clinical Outcomes of Advanced Heart Failure Patients With Cardiogenic Shock Treated With Temporary Circulatory Support Before Durable LVAD Implant","volume":"62","year":"2016","journal-title":"ASAIO J. (Am. Soc. Artif. Intern. Organs: 1992)"},{"key":"2025070707060700300_bib8","doi-asserted-by":"crossref","first-page":"733464","DOI":"10.3389\/fphys.2021.733464","article-title":"Effects of a Short-Term Left Ventricular Assist Device on Hemodynamics in a Heart Failure Patient-Specific Aorta Model: A CFD Study","volume":"12","year":"2021","journal-title":"Front. Physiol."},{"issue":"4","key":"2025070707060700300_bib9","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1097\/01.mat.0000225266.80021.9b","article-title":"An Evaluation of the Benefits of Pulsatile Versus Nonpulsatile Perfusion During Cardiopulmonary Bypass Procedures in Pediatric and Adult Cardiac Patients","volume":"52","year":"2006","journal-title":"ASAIO J. (Am. Soc. Artif. Intern. Organs: 1992)"},{"issue":"12","key":"2025070707060700300_bib10","doi-asserted-by":"crossref","first-page":"1094","DOI":"10.1111\/j.1525-1594.2003.07198.x","article-title":"Unloading Effect of a Rotary Blood Pump Assessed by Mathematical Modeling","volume":"27","year":"2003","journal-title":"Artif. Organs"},{"key":"2025070707060700300_bib11","doi-asserted-by":"crossref","first-page":"104640","DOI":"10.1016\/j.bspc.2023.104640","article-title":"A Sensorless, Physiologic Feedback Control Strategy to Increase Vascular Pulsatility for Rotary Blood Pumps","volume":"83","year":"2023","journal-title":"Biomed. Signal Process. Control"},{"key":"2025070707060700300_bib12","doi-asserted-by":"crossref","first-page":"103008","DOI":"10.1016\/j.bspc.2021.103008","article-title":"Control Strategy to Enhance Pulmonary Vascular Pulsatility for Implantable Cavopulmonary Assist Devices: A Simulation Study","volume":"70","year":"2021","journal-title":"Biomed. Signal Process. Control"},{"issue":"1","key":"2025070707060700300_bib13","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1186\/s12938-018-0591-4","article-title":"Effects on the Pulmonary Hemodynamics and Gas Exchange With a Speed Modulated Right Ventricular Assist Rotary Blood Pump: A Numerical Study","volume":"17","year":"2018","journal-title":"Biomed. Eng. Online"},{"issue":"4","key":"2025070707060700300_bib14","doi-asserted-by":"crossref","first-page":"e0195975","DOI":"10.1371\/journal.pone.0195975","article-title":"Pulsatile Operation of a Continuous-Flow Right Ventricular Assist Device (RVAD) to Improve Vascular Pulsatility","volume":"13","year":"2018","journal-title":"PLoS One"},{"issue":"8","key":"2025070707060700300_bib15","doi-asserted-by":"crossref","first-page":"2377","DOI":"10.1007\/s10439-016-1552-3","article-title":"Evaluation of Physiological Control Systems for Rotary Left Ventricular Assist Devices: An In-Vitro Study","volume":"44","year":"2016","journal-title":"Ann. Biomed. Eng."},{"issue":"10","key":"2025070707060700300_bib16","doi-asserted-by":"crossref","first-page":"1288","DOI":"10.1016\/j.medengphy.2014.07.005","article-title":"Arterial Pulsatility Improvement in a Feedback-Controlled Continuous Flow Left Ventricular Assist Device: An Ex-Vivo Experimental Study","volume":"36","year":"2014","journal-title":"Med. Eng. Phys."},{"issue":"1","key":"2025070707060700300_bib17","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1093\/icvts\/ivx236","article-title":"Rotational Speed Modulation Used With Continuous-Flow Left Ventricular Assist Device Provides Good Pulsatility","volume":"26","year":"2018","journal-title":"Interact. Cardiovasc. Thorac. Surg."},{"issue":"9","key":"2025070707060700300_bib18","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1111\/aor.12666","article-title":"Influence of a Rotational Speed Modulation System Used With an Implantable Continuous-Flow Left Ventricular Assist Device on Von Willebrand Factor Dynamics","volume":"40","year":"2016","journal-title":"Artif. Organs"},{"issue":"4","key":"2025070707060700300_bib19","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1007\/s10047-017-0958-5","article-title":"Generating Pulsatility by Pump Speed Modulation With Continuous-Flow Total Artificial Heart in Awake Calves","volume":"20","year":"2017","journal-title":"J. Artif. Organs: Off. J. Jpn. Soc. Artif. Organs"},{"key":"2025070707060700300_bib20","doi-asserted-by":"crossref","first-page":"107788","DOI":"10.1016\/j.compbiomed.2023.107788","article-title":"Numerical Simulation Analysis of Multi-Scale Computational Fluid Dynamics on Hemodynamic Parameters Modulated by Pulsatile Working Modes for the Centrifugal and Axial Left Ventricular Assist Devices","volume":"169","year":"2024","journal-title":"Comput. Biol. Med."},{"issue":"8","key":"2025070707060700300_bib21","first-page":"e005115","article-title":"Abdominal Positioning of the Next-Generation Intra-Aortic Fluid Entrainment Pump (Aortix) Improves Cardiac Output in a Swine Model of Heart Failure","volume":"11","year":"2018","journal-title":"Circ.: Heart Failure"},{"issue":"Pt. A","key":"2025070707060700300_bib22","first-page":"106271","article-title":"Multi-Indicator Analysis of Mechanical Blood Damage With Five Clinical Ventricular Assist Devices","volume":"151","year":"2022","journal-title":"Comput. Biol. Med."},{"issue":"9","key":"2025070707060700300_bib23","doi-asserted-by":"crossref","first-page":"1817","DOI":"10.1111\/aor.14265","article-title":"Investigation of the Influence of Blade Configuration on the Hemodynamic Performance and Blood Damage of the Centrifugal Blood Pump","volume":"46","year":"2022","journal-title":"Artif. Organs"},{"issue":"3","key":"2025070707060700300_bib24","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1007\/s13239-021-00531-0","article-title":"Validated Guidelines for Simulating Centrifugal Blood Pumps","volume":"12","year":"2021","journal-title":"Cardiovasc. Eng. Technol."},{"issue":"4","key":"2025070707060700300_bib25","doi-asserted-by":"crossref","first-page":"1326","DOI":"10.1016\/j.jtcvs.2013.09.069","article-title":"Computational Fluid Dynamics in Patients With Continuous-Flow Left Ventricular Assist Device Support Show Hemodynamic Alterations in the Ascending Aorta","volume":"147","year":"2014","journal-title":"J. Thorac. Cardiovasc. Surg."},{"issue":"2","key":"2025070707060700300_bib26","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1111\/aor.12132","article-title":"Comparison of Hemodynamics in the Ascending Aorta Between Pulsatile and Continuous Flow Left Ventricular Assist Devices Using Computational Fluid Dynamics Based on Computed Tomography Images","volume":"38","year":"2014","journal-title":"Artif. Organs"},{"key":"2025070707060700300_bib27","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/j.jcp.2012.07.035","article-title":"A Modular Numerical Method for Implicit 0D\/3D Coupling in Cardiovascular Finite Element Simulations","volume":"244","year":"2013","journal-title":"J. Comput. Phys."},{"issue":"1","key":"2025070707060700300_bib28","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1007\/s12572-016-0161-6","article-title":"Computational Fluid Dynamic Simulation of Human Carotid Artery Bifurcation Based on Anatomy and Volumetric Blood Flow Rate Measured With Magnetic Resonance Imaging","volume":"8","year":"2016","journal-title":"Int. J. Adv. Eng. Sci. Appl. Math."},{"key":"2025070707060700300_bib29","doi-asserted-by":"crossref","first-page":"116764","DOI":"10.1016\/j.cma.2024.116764","article-title":"A Modular Framework for Implicit 3D-0D Coupling in Cardiac Mechanics","volume":"421","year":"2024","journal-title":"Comput. Methods Appl. Mech. Eng."},{"issue":"1","key":"2025070707060700300_bib30","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/j.pbiomolbio.2014.09.003","article-title":"A Novel Patient-Specific Model to Compute Coronary Fractional Flow Reserve","volume":"116","year":"2014","journal-title":"Prog. Biophys. Mol. Biol."},{"issue":"2","key":"2025070707060700300_bib31","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1016\/j.bbe.2016.01.005","article-title":"Numerical Prediction of the Effect of Aortic Left Ventricular Assist Device Outflow-Graft Anastomosis Location","volume":"36","year":"2016","journal-title":"Biocybern. Biomed. Eng."},{"issue":"8","key":"2025070707060700300_bib32","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1111\/aor.13671","article-title":"Impact of Turbulent Blood Flow in the Aortic Root on De Novo Aortic Insufficiency During Continuous-Flow Left Ventricular-Assist Device Support","volume":"44","year":"2020","journal-title":"Artif. Organs"},{"issue":"11","key":"2025070707060700300_bib33","doi-asserted-by":"crossref","first-page":"710","DOI":"10.1177\/0391398820909843","article-title":"Hemolysis Associated With Impella Heart Pump Positioning: In Vitro Hemolysis Testing and Computational Fluid Dynamics Modeling","volume":"43","year":"2020","journal-title":"Int. J. Artif. Organs"},{"issue":"3","key":"2025070707060700300_bib34","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1097\/MAT.0000000000001221","article-title":"A Computational Fluid Dynamics Study of the Extracorporeal Membrane Oxygenation-Failing Heart Circulation","volume":"67","year":"2021","journal-title":"ASAIO J. (Am. Soc. Artif. Intern. Organs: 1992)"},{"volume-title":"The Fluid Mechanics of Large Blood Vessels","year":"1980","key":"2025070707060700300_bib35"},{"key":"2025070707060700300_bib36","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1146\/annurev.fluid.32.1.347","article-title":"Flows in Stenotic Vessels","volume":"32","year":"2000","journal-title":"Annu. Rev. Fluid Mech."},{"issue":"9","key":"2025070707060700300_bib37","doi-asserted-by":"crossref","first-page":"095005","DOI":"10.1088\/1361-6579\/acd3d0","article-title":"Regurgitation During the Fully Supported Condition of the Percutaneous Left Ventricular Assist Device","volume":"44","year":"2023","journal-title":"Physiol. Meas."},{"key":"2025070707060700300_bib38","doi-asserted-by":"crossref","first-page":"20140163","DOI":"10.1098\/rspa.2014.0163","article-title":"A Haemodynamic Predictor of Intraluminal Thrombus Formation in Abdominal Aortic Aneurysms","volume":"470","year":"2014","journal-title":"Proc. R. Soc. A: Math. Phys. Eng. Sci."},{"issue":"5","key":"2025070707060700300_bib39","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1097\/MAT.0b013e3181e7bf3c","article-title":"Hemodynamic Responses to Continuous Versus Pulsatile Mechanical Unloading of the Failing Left Ventricle","volume":"56","year":"2010","journal-title":"ASAIO J. (Am. Soc. Artif. Intern. Organs: 1992)"},{"key":"2025070707060700300_bib40","doi-asserted-by":"crossref","first-page":"2284","DOI":"10.12659\/MSM.896291","article-title":"Pulsatile Support Mode of BJUT-II Ventricular Assist Device (VAD) Has Better Hemodynamic Effects on the Aorta Than Constant Speed Mode: A Primary Numerical Study","volume":"22","year":"2016","journal-title":"Med. Sci. Monit.: Int. Med. J. Exp. Clin. Res."},{"issue":"1","key":"2025070707060700300_bib41","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1007\/s12028-018-0662-1","article-title":"Stroke Risk Following Infection in Patients With Continuous-Flow Left Ventricular Assist Device","volume":"31","year":"2019","journal-title":"Neurocrit. Care"},{"issue":"4","key":"2025070707060700300_bib42","doi-asserted-by":"crossref","first-page":"770","DOI":"10.1253\/circj.CJ-14-1079","article-title":"Attenuation in Peripheral Endothelial Function After Continuous Flow Left Ventricular Assist Device Therapy Is Associated With Cardiovascular Adverse Events","volume":"79","year":"2015","journal-title":"Circ. J.: Off. J. Jpn. Circ. Soc."},{"issue":"23","key":"2025070707060700300_bib43","first-page":"e185\u2013e187","article-title":"Images in Cardiovascular Medicine. Focal In-Stent Restenosis Near Step-Up: Roles of Low and Oscillating Shear Stress?","volume":"105","year":"2002","journal-title":"Circulation"},{"key":"2025070707060700300_bib44","doi-asserted-by":"crossref","first-page":"106609","DOI":"10.1016\/j.compbiomed.2023.106609","article-title":"How Does Hemodynamics Affect Rupture Tissue Mechanics in Abdominal Aortic Aneurysm: Focus on Wall Shear Stress Derived Parameters, Time-Averaged Wall Shear Stress, Oscillatory Shear Index, Endothelial Cell Activation Potential, and Relative Residence Time","volume":"154","year":"2023","journal-title":"Comput. Biol. Med."},{"issue":"1\u20132","key":"2025070707060700300_bib45","first-page":"27","article-title":"Hemodynamic Effects of the Human Aorta Arch With Different Inflow Rate Waveforms From the Ascending Aorta Inlet: A Numerical Study","volume":"58","year":"2021","journal-title":"Biorheology"},{"issue":"5","key":"2025070707060700300_bib46","first-page":"540","article-title":"Intraluminal Thrombus Characteristics in AAA Patients: Non-Invasive Diagnosis Using CFD","volume":"10","year":"2023","journal-title":"Bioengineering (Basel, Switzerland)"},{"issue":"2","key":"2025070707060700300_bib47","article-title":"A Computational Fluid Dynamics Comparison Between Different Outflow Graft Anastomosis Locations of Left Ventricular Assist Device (LVAD) in a Patient-Specific Aortic Model","volume":"31","year":"2014","journal-title":"Int. J. Numer. Methods Biomed. Eng."},{"issue":"3","key":"2025070707060700300_bib48","first-page":"3","article-title":"Computational Analysis of Aortic Hemodynamics During Total and Partial Extracorporeal Membrane Oxygenation and Intra-Aortic Balloon Pump Support","volume":"18","year":"2016","journal-title":"Acta Bioeng. Biomech."}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/147\/8\/081007\/7515645\/bio-24-1339.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/147\/8\/081007\/7515645\/bio-24-1339.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,7]],"date-time":"2025-07-07T11:06:19Z","timestamp":1751886379000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/147\/8\/081007\/1219055\/Impact-of-Short-Term-Percutaneous-Interventional"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,20]]},"references-count":48,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2025,8,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4068910","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"type":"print","value":"0148-0731"},{"type":"electronic","value":"1528-8951"}],"subject":[],"published":{"date-parts":[[2025,6,20]]},"article-number":"081007"}}