{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T12:25:14Z","timestamp":1785414314994,"version":"3.56.0"},"reference-count":32,"publisher":"ASME International","issue":"12","license":[{"start":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T00:00:00Z","timestamp":1761091200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.asme.org\/publications-submissions\/publishing-information\/legal-policies"}],"content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,12,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The patient-specific mandibular reconstruction plate (PSMRP) has gained prominence for its precise adaptation to mandibular contours and reported enhanced mechanical reliability compared to the manual-bent mandibular reconstruction plate (MBMRP). Despite this, a biomechanical comparison between MBMRP and PSMRP is essential for informed clinical decision-making and advancing the field of mandibular reconstruction. Thereupon, biomechanical behavior was compared between two reconstructed mandibles with the MBMRP made of commercial pure titanium plate and the PSMRP stemmed from a common ramus reconstruction case, respectively, in physiological simulation using finite element analyses. Results reveal that the PSMRP presents greater safety and better stability to the reconstructed mandible than the MBMRP in the physiological situation, indicated by over 45% lower peak equivalent von Mises stress and more than 35% less maximum displacement.<\/jats:p>","DOI":"10.1115\/1.4069665","type":"journal-article","created":{"date-parts":[[2025,9,6]],"date-time":"2025-09-06T07:56:49Z","timestamp":1757145409000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":3,"title":["Biomechanics of Manual-Bent Versus Patient-Specific Mandibular Implants"],"prefix":"10.1115","volume":"147","author":[{"given":"Shengping","family":"Zhong","sequence":"first","affiliation":[{"name":"Department of Imaging & Pathology, Faculty of Medicine, KU Leuven , Kapucijnenvoer 7, Box 7003, Leuven 3000, Belgium; , Kapucijnenvoer 33, Leuven 3000, Belgium; , No. 266 Fangzheng Avenue, Chongqing 400714, China"},{"name":"Oral and Maxillofacial Surgery, University Hospitals Leuven , Kapucijnenvoer 7, Box 7003, Leuven 3000, Belgium; , Kapucijnenvoer 33, Leuven 3000, Belgium; , No. 266 Fangzheng Avenue, Chongqing 400714, China"},{"name":"Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences , Kapucijnenvoer 7, Box 7003, Leuven 3000, Belgium; , Kapucijnenvoer 33, Leuven 3000, Belgium; , No. 266 Fangzheng Avenue, Chongqing 400714, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Materials Engineering, KU Leuven, Elooi Laboratory , Gent Campus, Gebroeders de Smetstraat 1, Gent 9000, Belgium; , Beijing 100083, China"},{"name":"Collaborative Innovation Center of Steel Technology, University of Science and Technology Beijing , Gent Campus, Gebroeders de Smetstraat 1, Gent 9000, Belgium; , Beijing 100083, China"},{"id":[{"id":"https:\/\/ror.org\/05f950310","id-type":"ROR","asserted-by":"publisher"}],"name":"KU Leuven"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qimin","family":"Shi","sequence":"additional","affiliation":[{"name":"Department of Imaging & Pathology, Faculty of Medicine, KU Leuven , Kapucijnenvoer 7, Box 7003, Leuven 3000, Belgium; , Kapucijnenvoer 33, Leuven 3000, Belgium; , No. 266 Fangzheng Avenue, Chongqing 400714, China"},{"name":"Oral and Maxillofacial Surgery, University Hospitals Leuven , Kapucijnenvoer 7, Box 7003, Leuven 3000, Belgium; , Kapucijnenvoer 33, Leuven 3000, Belgium; , No. 266 Fangzheng Avenue, Chongqing 400714, China"},{"name":"Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences , Kapucijnenvoer 7, Box 7003, Leuven 3000, Belgium; , Kapucijnenvoer 33, Leuven 3000, Belgium; , No. 266 Fangzheng Avenue, Chongqing 400714, China"},{"id":[{"id":"https:\/\/ror.org\/031npqv35","id-type":"ROR","asserted-by":"publisher"}],"name":"Chongqing Institute of Green and Intelligent Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeroen","family":"Van Dessel","sequence":"additional","affiliation":[{"name":"Department of Imaging & Pathology, Faculty of Medicine, KU Leuven , Kapucijnenvoer 7, Box 7003, Leuven 3000, Belgium; , Kapucijnenvoer 33, Leuven 3000, Belgium"},{"name":"Oral and Maxillofacial Surgery, University Hospitals Leuven , Kapucijnenvoer 7, Box 7003, Leuven 3000, Belgium; , Kapucijnenvoer 33, Leuven 3000, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joris","family":"Geusens","sequence":"additional","affiliation":[{"name":"Oral and Maxillofacial Surgery, University Hospitals Leuven , Kapucijnenvoer 33, Leuven 3000, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sam","family":"Coppieters","sequence":"additional","affiliation":[{"name":"Department of Materials Engineering, KU Leuven, Elooi Laboratory , Gent Campus, Gebroeders de Smetstraat 1, Gent 9000, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bart","family":"Van Meerbeek","sequence":"additional","affiliation":[{"name":"Department of Oral Health Sciences, Biomaterials Research Group, KU Leuven , Kapucijnenvoer 7, Box 7001, Leuven 3000, Belgium; , Kapucijnenvoer 7, Box 7001, Leuven 3000, Belgium"},{"name":"Dentistry, University Hospitals Leuven , Kapucijnenvoer 7, Box 7001, Leuven 3000, Belgium; , Kapucijnenvoer 7, Box 7001, Leuven 3000, Belgium"},{"id":[{"id":"https:\/\/ror.org\/05f950310","id-type":"ROR","asserted-by":"publisher"}],"name":"KU Leuven"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Constantinus","family":"Politis","sequence":"additional","affiliation":[{"name":"Department of Imaging & Pathology, Faculty of Medicine, KU Leuven , Kapucijnenvoer 7, Box 7003, Leuven 3000, Belgium; , Kapucijnenvoer 33, Leuven 3000, Belgium"},{"name":"Oral and Maxillofacial Surgery, University Hospitals Leuven , Kapucijnenvoer 7, Box 7003, Leuven 3000, Belgium; , Kapucijnenvoer 33, Leuven 3000, Belgium"},{"id":[{"id":"https:\/\/ror.org\/05f950310","id-type":"ROR","asserted-by":"publisher"}],"name":"KU Leuven"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shoufeng","family":"Yang","sequence":"additional","affiliation":[{"name":"Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences , No. 266 Fangzheng Avenue, Chongqing 400714, China"},{"id":[{"id":"https:\/\/ror.org\/031npqv35","id-type":"ROR","asserted-by":"publisher"}],"name":"Chongqing Institute of Green and Intelligent Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi","family":"Sun","sequence":"additional","affiliation":[{"name":"Oral and Maxillofacial Surgery, University Hospitals Leuven , Kapucijnenvoer 33, Leuven 3000, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"33","published-online":{"date-parts":[[2025,10,22]]},"reference":[{"issue":"7","key":"2025102310492383000_bib1","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1016\/j.ijom.2008.03.002","article-title":"Mandibular Reconstruction in Adults: A Review","volume":"37","year":"2008","journal-title":"Int. J. Oral Maxillofac. Surg."},{"issue":"4","key":"2025102310492383000_bib2","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1007\/s12663-015-0766-5","article-title":"Mandibular Reconstruction: Overview","volume":"15","year":"2016","journal-title":"J. Maxillofac. Oral Surg."},{"issue":"6","key":"2025102310492383000_bib3","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1002\/lio2.325","article-title":"Reconstruction of Segmental Mandibular Defects: Current Procedures and Perspectives","volume":"4","year":"2019","journal-title":"Laryngoscope Invest. Otolaryngol."},{"key":"2025102310492383000_bib4","doi-asserted-by":"crossref","first-page":"104849","DOI":"10.1016\/j.jmbbm.2021.104849","article-title":"Biomechanical Comparison of Locking and Non-Locking Patient-Specific Mandibular Reconstruction Plate Using Finite Element Analysis","volume":"124","year":"2021","journal-title":"J. Mech. Behav. Biomed. Mater."},{"issue":"9","key":"2025102310492383000_bib5","doi-asserted-by":"crossref","first-page":"960","DOI":"10.1016\/j.ijom.2009.03.721","article-title":"Mandibular Reconstruction and Second Generation Locking Reconstruction Plates: Outcome of 110 Patients","volume":"38","year":"2009","journal-title":"Int. J. Oral Maxillofac. Surg."},{"issue":"12","key":"2025102310492383000_bib6","doi-asserted-by":"crossref","first-page":"2035","DOI":"10.1007\/s11548-015-1193-2","article-title":"Multicenter Study on the Use of Patient-Specific CAD\/CAM Reconstruction Plates for Mandibular Reconstruction","volume":"10","year":"2015","journal-title":"Int. J. Comput. Assisted Radiol. Surg."},{"issue":"2","key":"2025102310492383000_bib7","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1055\/s-0034-1371356","article-title":"Computer-Assisted Mandibular Reconstruction Using a Patient-Specific Reconstruction Plate Fabricated With Computer-Aided Design and Manufacturing Techniques","volume":"7","year":"2014","journal-title":"Craniomaxillofac. Trauma Reconstr."},{"issue":"4","key":"2025102310492383000_bib8","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1080\/10255842.2016.1240788","article-title":"Customized Mandibular Reconstruction Plates Improve Mechanical Performance in a Mandibular Reconstruction Model","volume":"20","year":"2017","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"issue":"10","key":"2025102310492383000_bib9","doi-asserted-by":"crossref","first-page":"1671","DOI":"10.1016\/j.jcms.2017.07.010","article-title":"Biomechanical Evaluation of a Novel Hybrid Reconstruction Plate for Mandible Segmental Defects: A Finite Element Analysis and Fatigue Testing","volume":"45","year":"2017","journal-title":"J. Craniomaxillofac. Surg."},{"key":"2025102310492383000_bib10","doi-asserted-by":"crossref","first-page":"107023","DOI":"10.1016\/j.cmpb.2022.107023","article-title":"Biomechanical Validation of Structural Optimized Patient-Specific Mandibular Reconstruction Plate Orienting Additive Manufacturing","volume":"224","year":"2022","journal-title":"Comput. Methods Progr. Biomed."},{"issue":"1","key":"2025102310492383000_bib11","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1016\/j.jbiomech.2013.11.016","article-title":"Finite Element Analysis of Customized Reconstruction Plates for Mandibular Continuity Defect Therapy","volume":"47","year":"2014","journal-title":"J. Biomech."},{"key":"2025102310492383000_bib12","doi-asserted-by":"crossref","first-page":"105008","DOI":"10.1016\/j.compbiomed.2021.105008","article-title":"Preclinical Study of Additive Manufactured Plates With Shortened Lengths for Complete Mandible Reconstruction: Design, Biomechanics Simulation, and Fixation Stability Assessment","volume":"139","year":"2021","journal-title":"Comput. Biol. Med."},{"key":"2025102310492383000_bib13","article-title":"Finite Element Analysis in Orthopaedic Biomechanics","volume-title":"Finite Element Analysis","year":"2010"},{"key":"2025102310492383000_bib14","doi-asserted-by":"crossref","first-page":"109843","DOI":"10.1016\/j.compbiomed.2025.109843","article-title":"Biomechanical Assessment in Virtual Surgical Planning for Mandibular Reconstruction","volume":"189","year":"2025","journal-title":"Comput. Biol. Med."},{"issue":"6","key":"2025102310492383000_bib15","doi-asserted-by":"crossref","first-page":"1265","DOI":"10.1111\/odi.13331","article-title":"Novel Finite Element-Based Plate Design for Bridging Mandibular Defects: Reducing Mechanical Failure","volume":"26","year":"2020","journal-title":"Oral Dis."},{"key":"2025102310492383000_bib16","doi-asserted-by":"crossref","first-page":"106197","DOI":"10.1016\/j.jmbbm.2023.106197","article-title":"Biomechanical Feasibility of Non-Locking System in Patient-Specific Mandibular Reconstruction Using Fibular Free Flaps","volume":"148","year":"2023","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"2025102310492383000_bib17","doi-asserted-by":"crossref","first-page":"105353","DOI":"10.1016\/j.engfailanal.2021.105353","article-title":"Failure Analysis of an in-Vivo Fractured Patient-Specific Ti6Al4V Mandible Reconstruction Plate Fabricated by Selective Laser Melting","volume":"124","year":"2021","journal-title":"Eng. Failure Anal."},{"issue":"10","key":"2025102310492383000_bib18","doi-asserted-by":"crossref","first-page":"2116","DOI":"10.1016\/j.jcms.2015.10.004","article-title":"The Feasibility of a Custom-Made Endoprosthesis in Mandibular Reconstruction: Implant Design and Finite Element Analysis","volume":"43","year":"2015","journal-title":"J. Craniomaxillofac. Surg."},{"key":"2025102310492383000_bib19","volume-title":"Fatigue Behaviour of 6061 Aluminium Alloy and Its Composite","year":"2001"},{"key":"2025102310492383000_bib20","first-page":"623","article-title":"Fatigue Life Characterization of Additively Manufactured Acrylic Like Poly-Jet Printed Parts","volume-title":"Advances in Structural Integrity: Proceedings of SICE 2016","year":"2018"},{"key":"2025102310492383000_bib21","first-page":"256","article-title":"Fatigue Life Prediction of Laser and Mechanically Formed Commercially Pure Grade 2 Titanium Alloy Plates","volume":"48","year":"2020","journal-title":"Proc. Manuf."},{"issue":"1","key":"2025102310492383000_bib22","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.jmbbm.2007.04.002","article-title":"Fatigue of Mineralized Tissues: Cortical Bone and Dentin","volume":"1","year":"2008","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"2025102310492383000_bib23","first-page":"75","article-title":"Fatigue of ti-6al-4v","volume-title":"Biomedical Engineering: Technical Applications in Medicine","year":"2012"},{"issue":"3","key":"2025102310492383000_bib24","first-page":"188","article-title":"High Cycle Fatigue Properties of as-Built Ti6al4v (Eli) Produced by Direct Metal Laser Sintering","volume":"28","year":"2017","journal-title":"S. Afr. J. Ind. Eng."},{"issue":"4","key":"2025102310492383000_bib25","doi-asserted-by":"crossref","first-page":"1707","DOI":"10.1007\/s00784-017-2263-3","article-title":"Mandibular Kinematics and Maximum Voluntary Bite Force Following Segmental Resection of the Mandible Without or With Reconstruction","volume":"22","year":"2018","journal-title":"Clin. Oral Invest."},{"issue":"1","key":"2025102310492383000_bib26","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1002\/hed.25445","article-title":"Masticatory Function and Related Factors After Oral Oncological Treatment: A 5-Year Prospective Study","volume":"41","year":"2019","journal-title":"Head Neck"},{"issue":"4","key":"2025102310492383000_bib27","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1002\/(SICI)1097-0347(199707)19:4<287::AID-HED7>3.0.CO;2-X","article-title":"A Comparison of Masticatory Function in Patients With or Without Reconstruction of the Mandible","volume":"19","year":"1997","journal-title":"Head Neck"},{"issue":"1","key":"2025102310492383000_bib28","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1177\/00220345940730010801","article-title":"Deformation of the Human Mandible During Simulated Tooth Clenching","volume":"73","year":"1994","journal-title":"J. Dent. Res."},{"issue":"2","key":"2025102310492383000_bib29","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1053\/joms.2002.29817","article-title":"Fracture of Mandibular Reconstruction Plates Used After Tumor Resection","volume":"60","year":"2002","journal-title":"J. Oral Maxillofac. Surg."},{"issue":"4","key":"2025102310492383000_bib30","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1016\/j.ijom.2009.11.003","article-title":"Biomechanics of Mandibular Reconstruction: A Review","volume":"39","year":"2010","journal-title":"Int. J. Oral Maxillofac. Surg."},{"issue":"1","key":"2025102310492383000_bib31","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1177\/10454411000110010101","article-title":"Biomechanics of the Mandible","volume":"11","year":"2000","journal-title":"Crit. Rev. Oral Biol. Med."},{"key":"2025102310492383000_bib32","doi-asserted-by":"crossref","first-page":"105483","DOI":"10.1016\/j.jmbbm.2022.105483","article-title":"On Interaction Between Fatigue of Reconstruction Plate and Time-Dependent Bone Remodeling","volume":"136","year":"2022","journal-title":"J. Mech. Behav. Biomed. Mater."}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/147\/12\/121001\/7535837\/bio-25-1144.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/147\/12\/121001\/7535837\/bio-25-1144.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,23]],"date-time":"2025-10-23T14:49:32Z","timestamp":1761230972000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/147\/12\/121001\/1221991\/Biomechanics-of-Manual-Bent-Versus-Patient"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,22]]},"references-count":32,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2025,12,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4069665","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,22]]},"article-number":"121001"}}