{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T16:25:15Z","timestamp":1788452715820,"version":"build-2803163510"},"reference-count":38,"publisher":"ASME International","issue":"11","license":[{"start":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T00:00:00Z","timestamp":1788307200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.asme.org\/publications-submissions\/publishing-information\/legal-policies"}],"funder":[{"DOI":"10.13039\/100007258","name":"State University of New York","doi-asserted-by":"publisher","award":["SUNY Polytechnic Institute Seed Grant"],"award-info":[{"award-number":["SUNY Polytechnic Institute Seed Grant"]}],"id":[{"id":"10.13039\/100007258","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,11,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Airway pressure release ventilation (APRV) using the time-controlled adaptive ventilation (TCAV) method is seen to enhance proximal mucus movement relative to conventional volume-controlled ventilation (VCV), yet the airway-scale flow physics responsible for this behavior remain poorly understood. This study uses unsteady Reynolds-averaged Navier\u2013Stokes simulations to examine how ventilator waveform timing and endotracheal tube (ETT) cuff geometry modify flow structures in an intubated tracheobronchial airway. Simulations were conducted in an idealized, asymmetric, three-dimensional Weibel airway model using three ventilation modes: assisted VCV, TCAV, and a modified high-duty-cycle VCV waveform designed to reproduce observed expiratory-biased flow conditions. Two ETT cuff geometries, representing Microcuff\u2122 and TaperGuard\u2122 styles, were analyzed under identical ventilator settings to isolate cuff-induced effects. Results show that assisted VCV generates a persistent high-momentum core and large-scale recirculatory structures, producing heterogeneous shear and strong jet\u2013wall interactions. In contrast, TCAV suppresses large-scale recirculation and promotes more organized, wall-bounded shear layers, which is associated with reduced inspiratory shear exposure and more coherent expiratory flow structures. Cuff geometry strongly modulates these dynamics: the Microcuff sustains greater vortical persistence within the bronchi, whereas the TaperGuard produces a more ordered but less dynamically mixed flow field. Together, these results indicate that ventilator timing and cuff geometry govern airway flow organization, shear distribution, and unsteady transport characteristics. These airflow features are consistent with conditions that may be associated with secretion mobilization, although secretion transport is not directly resolved in the present simulations.<\/jats:p>","DOI":"10.1115\/1.4072574","type":"journal-article","created":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T09:41:42Z","timestamp":1787046102000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":0,"title":["Computational Analysis of Unsteady Airway Flow Physics During Airway Pressure Release Ventilation"],"prefix":"10.1115","volume":"148","author":[{"given":"Aarthi","family":"Sekaran","sequence":"first","affiliation":[{"id":[{"id":"https:\/\/ror.org\/000fxgx19","id-type":"ROR","asserted-by":"publisher"}],"name":"SUNY Polytechnic Institute Department of Civil and Mechanical Engineering, , Utica, NY 13502"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gary F.","family":"Nieman","sequence":"additional","affiliation":[{"id":[{"id":"https:\/\/ror.org\/040kfrw16","id-type":"ROR","asserted-by":"publisher"}],"name":"SUNY Upstate Medical University Department of Surgery, , Syracuse, NY 13210"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"33","published-online":{"date-parts":[[2026,9,2]]},"reference":[{"issue":"10","key":"2026090311424971400_bib1","doi-asserted-by":"crossref","first-page":"2184","DOI":"10.1097\/01.CCM.0000181731.53912.D9","article-title":"Clinical and Economic Consequences of Ventilator-Associated Pneumonia: A Systematic Review","volume":"33","year":"2005","journal-title":"Crit. Care Med."},{"issue":"3","key":"2026090311424971400_bib2","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1086\/664049","article-title":"Economic Impact of Ventilator-Associated Pneumonia in a Large Matched Cohort","volume":"33","year":"2012","journal-title":"Infect. Control Hosp. Epidemiol."},{"issue":"5","key":"2026090311424971400_bib3","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1007\/s00134-020-05980-0","article-title":"Ventilator-Associated Pneumonia in Adults: A Narrative Review","volume":"46","year":"2020","journal-title":"Intensive Care Med."},{"issue":"9","key":"2026090311424971400_bib4","doi-asserted-by":"crossref","first-page":"5518","DOI":"10.21037\/jtd-24-150","article-title":"Incidence and Risk Factors of Ventilator-Associated Pneumonia in the Intensive Care Unit: A Systematic Review and Meta-Analysis","volume":"16","year":"2024","journal-title":"J. Thorac. Dis."},{"issue":"2","key":"2026090311424971400_bib5","doi-asserted-by":"crossref","first-page":"518","DOI":"10.1097\/01.CCM.0000299741.32078.E9","article-title":"Following Tracheal Intubation, Mucus Flow Is Reversed in the Semirecumbent Position: Possible Role in the Pathogenesis of Ventilator-Associated Pneumonia","volume":"36","year":"2008","journal-title":"Crit. Care Med."},{"issue":"1","key":"2026090311424971400_bib6","first-page":"57","article-title":"Ventilator-Associated Pneumonia: Role of Positioning","volume":"17","year":"2011","journal-title":"Curr. Opin. Crit. Care"},{"issue":"3","key":"2026090311424971400_bib7","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1097\/CCM.0b013e318236efb5","article-title":"Effects of Duty Cycle and Positive End-Expiratory Pressure on Mucus Clearance During Mechanical Ventilation","volume":"40","year":"2012","journal-title":"Crit. Care Med."},{"issue":"1","key":"2026090311424971400_bib8","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1186\/s40635-019-0250-5","article-title":"Time-Controlled Adaptive Ventilation (TCAV) Accelerates Simulated Mucus Clearance Via Increased Expiratory Flow Rate","volume":"7","year":"2019","journal-title":"Intensive Care Med. Exp."},{"issue":"18","key":"2026090311424971400_bib9","doi-asserted-by":"crossref","first-page":"1301","DOI":"10.1056\/NEJM200005043421801","article-title":"Ventilation With Lower Tidal Volumes as Compared With Traditional Tidal Volumes for Acute Lung Injury and the Acute Respiratory Distress Syndrome","volume":"342","year":"2000","journal-title":"N. Engl. J. Med."},{"key":"2026090311424971400_bib10","doi-asserted-by":"crossref","first-page":"1741129","DOI":"10.3389\/fmed.2026.1741129","article-title":"Expert Recommendations for Setting and Adjusting Airway Pressure Release Ventilation Based on Clinical Experience and Basic Science Evidence","volume":"13","year":"2026","journal-title":"Front. Med."},{"key":"2026090311424971400_bib11","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1007\/978-3-031-66352-9_5","article-title":"The Acutely Injured Lung Becomes Time\/Press Dependent","volume-title":"Applied Physiology to Reduce Ventilator Induced Lung Injury: Clinical Applications for the Acutely Injured Lung","year":"2024"},{"issue":"5","key":"2026090311424971400_bib12","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1097\/00003246-198705000-00002","article-title":"Airway Pressure Release Ventilation","volume":"15","year":"1987","journal-title":"Crit. Care Med."},{"issue":"2","key":"2026090311424971400_bib13","first-page":"234","article-title":"Airway Pressure Release Ventilation: Theory and Practice","volume":"12","year":"2001","journal-title":"AACN Adv. Crit. Care"},{"issue":"11","key":"2026090311424971400_bib14","doi-asserted-by":"crossref","first-page":"1138","DOI":"10.1001\/jamasurg.2014.1829","article-title":"Mechanical Breath Profile of Airway Pressure Release Ventilation: The Effect on Alveolar Recruitment and Microstrain in Acute Lung Injury","volume":"149","year":"2014","journal-title":"JAMA Surg."},{"issue":"5","key":"2026090311424971400_bib15","doi-asserted-by":"crossref","first-page":"968","DOI":"10.1016\/j.jamcollsurg.2014.09.011","article-title":"Airway Pressure Release Ventilation Reduces Conducting Airway Micro-Strain in Lung Injury","volume":"219","year":"2014","journal-title":"J. Am. Coll. Surg."},{"issue":"1","key":"2026090311424971400_bib16","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1097\/SHK.0b013e31827b47bb","article-title":"Early Airway Pressure Release Ventilation Prevents ARDS\u2014A Novel Preventive Approach to Lung Injury","volume":"39","year":"2013","journal-title":"Shock"},{"issue":"1","key":"2026090311424971400_bib17","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1186\/s40635-015-0071-0","article-title":"The Effects of Airway Pressure Release Ventilation on Respiratory Mechanics in Extrapulmonary Lung Injury","volume":"3","year":"2015","journal-title":"Intensive Care Med. Exp."},{"issue":"1","key":"2026090311424971400_bib18","first-page":"76","article-title":"Airway Pressure Release Ventilation for Lung Protection in Acute Respiratory Distress Syndrome: An Alternative Way to Recruit the Lungs","volume":"30","year":"2024","journal-title":"Curr. Opin. Crit. Care"},{"issue":"1","key":"2026090311424971400_bib19","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1186\/s13054-022-04105-x","article-title":"Unshrinking the Baby Lung to Calm the VILI Vortex","volume":"26","year":"2022","journal-title":"Crit. Care"},{"issue":"12","key":"2026090311424971400_bib20","doi-asserted-by":"crossref","first-page":"312","DOI":"10.3390\/fluids10120312","article-title":"Computational and Experimental Characterization of Flow in an Intubated Human Trachea","volume":"10","year":"2025","journal-title":"Fluids"},{"key":"2026090311424971400_bib21","volume-title":"Morphometry of the Human Lung","year":"1963"},{"issue":"5","key":"2026090311424971400_bib22","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1016\/j.jbiomech.2003.09.024","article-title":"Modelling of Peak-Flow Wall Shear Stress in Major Airways of the Lung","volume":"37","year":"2004","journal-title":"J. Biomech."},{"key":"2026090311424971400_bib23","unstructured":"Xlung, 2012, \u201cMechanical Ventilation Simulator,\u201d Xlung, Brazil, accessed Apr. 27, 2026, https:\/\/xlung.net\/en\/"},{"issue":"6097","key":"2026090311424971400_bib24","doi-asserted-by":"crossref","first-page":"937","DOI":"10.1126\/science.1223012","article-title":"A Periciliary Brush Promotes the Lung Health by Separating the Mucus Layer From Airway Epithelia","volume":"337","year":"2012","journal-title":"Science"},{"issue":"1","key":"2026090311424971400_bib25","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1016\/j.prrv.2007.02.004","article-title":"Mucus Structure and Properties in Cystic Fibrosis","volume":"8","year":"2007","journal-title":"Paediatr. Respir. Rev."},{"key":"2026090311424971400_bib26","doi-asserted-by":"crossref","first-page":"S212","DOI":"10.1016\/j.prrv.2006.04.199","article-title":"Physiology of Mucus Clearance","volume":"7","year":"2006","journal-title":"Paediatr. Respir. Rev."},{"issue":"4","key":"2026090311424971400_bib27","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1080\/08958370117648","article-title":"Fluid Dynamics in Airway Bifurcations: I. Primary Flows","volume":"13","year":"2001","journal-title":"Inhal. Toxicol."},{"key":"2026090311424971400_bib28","first-page":"455","article-title":"Airflow and Particle Transport in the Human Respiratory System","volume":"35","year":"2003","journal-title":"Annu. Rev. Fluid Mech."},{"key":"2026090311424971400_bib29","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1016\/j.jaerosci.2011.05.007","article-title":"Modelling Inhaled Particle Deposition in the Human Lung","volume":"42","year":"2011","journal-title":"J. Aerosol Sci."},{"issue":"6","key":"2026090311424971400_bib30","first-page":"455","article-title":"Laminar-to-Turbulent Fluid\u2013Particle Flows in a Human Airway Model","volume":"36","year":"2010","journal-title":"Int. J. Multiphase Flow"},{"issue":"6","key":"2026090311424971400_bib31","doi-asserted-by":"crossref","first-page":"2310","DOI":"10.1152\/japplphysiol.00520.2004","article-title":"CT-Based Geometry Analysis and Finite Element Models of the Human and Ovine Bronchial Tree","volume":"97","year":"2004","journal-title":"J. Appl. Physiol."},{"issue":"11","key":"2026090311424971400_bib32","doi-asserted-by":"crossref","first-page":"2159","DOI":"10.1016\/j.jbiomech.2010.03.048","article-title":"Simulation of Pulmonary Air Flow With a Subject-Specific Boundary Condition","volume":"43","year":"2010","journal-title":"J. Biomech."},{"issue":"8","key":"2026090311424971400_bib33","doi-asserted-by":"crossref","first-page":"e72675","DOI":"10.1371\/journal.pone.0072675","article-title":"Effect of PEEP and Tidal Volume on Ventilation Distribution and End-Expiratory Lung Volume: A Prospective Experimental Animal and Pilot Clinical Study","volume":"8","year":"2013","journal-title":"PLoS One"},{"issue":"3","key":"2026090311424971400_bib34","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1097\/CCM.0b013e318236f452","article-title":"Tidal Recruitment Assessed by Electrical Impedance Tomography and Computed Tomography in a Porcine Model of Lung Injury","volume":"40","year":"2012","journal-title":"Crit. Care Med."},{"issue":"1\u20133","key":"2026090311424971400_bib35","first-page":"128","article-title":"Modeling Airflow and Particle Transport\/Deposition in Pulmonary Airways","volume":"163","year":"2008","journal-title":"Respir. Physiol. Neurobiol."},{"issue":"9","key":"2026090311424971400_bib36","doi-asserted-by":"crossref","first-page":"2281","DOI":"10.1063\/1.869828","article-title":"The Formation and Evolution of Synthetic Jets","volume":"10","year":"1998","journal-title":"Phys. Fluids"},{"issue":"3","key":"2026090311424971400_bib37","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1152\/japplphysiol.01049.2005","article-title":"Physical Stresses at the Air\u2013Wall Interface of the Human Nasal Cavity During Breathing","volume":"100","year":"2006","journal-title":"J. Appl. Physiol."},{"issue":"10","key":"2026090311424971400_bib38","first-page":"1","article-title":"Mechanical Ventilation Energy Analysis: Recruitment Focuses Injurious Power in the Ventilated Lung","volume":"122","year":"2025","journal-title":"Proc. Natl. Acad. Sci. U. S. A."}],"container-title":["Journal of Biomechanical Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/148\/11\/111001\/7633460\/bio-26-1038.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article-pdf\/148\/11\/111001\/7633460\/bio-26-1038.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T16:03:36Z","timestamp":1788451416000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/biomechanical\/article\/148\/11\/111001\/1234849\/Computational-Analysis-of-Unsteady-Airway-Flow"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,2]]},"references-count":38,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2026,11,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4072574","relation":{},"ISSN":["0148-0731","1528-8951"],"issn-type":[{"value":"0148-0731","type":"print"},{"value":"1528-8951","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,2]]},"article-number":"111001"}}