{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T09:05:48Z","timestamp":1769159148747,"version":"3.49.0"},"reference-count":65,"publisher":"ASME International","issue":"4","content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2010,12,1]]},"abstract":"<jats:p>The use of biodegradable polymers in biomedical applications has been successful in nonload bearing applications, such as biodegradable implants for local drug delivery, and in simple load bearing situations such as surgical sutures and orthopedic fixation screws. The desire to incorporate these materials in more complex load bearing situations, such as tissue engineering scaffolds and endovascular or urethral stents, is strong, but the lack of constitutive models describing the evolution of biodegradable polymers over the course of degradation has severely hampered the rational design process for these more complex biodegradable medical applications. With the objective of predicting biodegradable stent behavior, we incorporated constitutive models of biodegradable polymeric materials in a computational setting and the mechanical response of three different stent designs were analyzed as degradation progressed. A thermodynamically consistent constitutive model for materials undergoing deformation-induced degradation was applied to a commonly employed biodegradable polymer system, poly(L-lactic acid), and its specific form was determined by corroboration against experimental data. Depreciation of mechanical properties due to degradation confers time-dependent characteristics to the response of the biodegradable material: the deformation imparted by a constant load increases over time, i.e. the body creeps, and the stress necessary to keep a fixed deformation decreases, i.e. the body relaxes. Biodegradable stents, when subjected to constant pressure in its exterior, deflect inwards and ultimately fail as the structure loses its mechanical integrity. The complex geometry of endovascular stents and their physiological loading conditions lead to inhomogeneous deformations, and consequently, inhomogeneous degradation ensues. Degradation is mostly confined to the bends of the stent rings and junction points, which are the locations that carry most of the deformation, whereas mostly undeformed connector bars remain less degraded. If failure occurs, it will occur most likely at those sensitive locations and large, nondegraded pieces can provoke severe embolic problems. Highly nonuniform degradation indicates that some stent designs are at higher risk for complications. Deformation patterns of stents made of a material that loses its integrity are different than those of permanent stents. Blind adaptation of permanent stent design concepts is ill-suited for biodegradable stent design. The time-dependent aspect of the implant not only must be taken into account but should also be used to interact with the body\u2019s reaction and to enhance healing.<\/jats:p>","DOI":"10.1115\/1.4002759","type":"journal-article","created":{"date-parts":[[2010,12,6]],"date-time":"2010-12-06T23:27:47Z","timestamp":1291678067000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":31,"title":["Modeling of Deformation-Accelerated Breakdown of Polylactic Acid Biodegradable Stents"],"prefix":"10.1115","volume":"4","author":[{"given":"Jo\u00e3o S.","family":"Soares","sequence":"first","affiliation":[{"name":"Department of Mathematics, Center for Mathematics and Its Applications (CEMAT), Instituto Superior Tecnico, Avenida Rovisto Pais 1, Lisboa 1049-001, Portugal"}]},{"suffix":"Jr.","given":"James E.","family":"Moore","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Texas A&M University, 337 Zachry Engineering Center, 3120 TAMU, College Station, TX 77843"}]},{"given":"Kumbakonam R.","family":"Rajagopal","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Department of Mechanical Engineering, Texas A&M University, College Station, TX 77843"}]}],"member":"33","published-online":{"date-parts":[[2010,12,6]]},"reference":[{"issue":"4","key":"2019100413554653800_c1","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1161\/01.CIR.102.4.371","article-title":"Biodegradable Stents: \u2018Fulfilling the Mission and Stepping Away\u2019","volume":"102","author":"Colombo","journal-title":"Circulation","ISSN":"https:\/\/id.crossref.org\/issn\/0009-7322","issn-type":"print"},{"issue":"8","key":"2019100413554653800_c2","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1056\/NEJM199408253310801","article-title":"A Comparison of Balloon-Expandable-Stent Implantation With Balloon Angioplasty in Patients With Coronary-Artery Disease","volume":"331","author":"Serruys","journal-title":"N. Engl. J. Med.","ISSN":"https:\/\/id.crossref.org\/issn\/0028-4793","issn-type":"print"},{"issue":"8","key":"2019100413554653800_c3","doi-asserted-by":"publisher","first-page":"496","DOI":"10.1056\/NEJM199408253310802","article-title":"A Randomized Comparison of Coronary-Stent Placement and Balloon Angioplasty in the Treatment of Coronary-Artery Disease","volume":"331","author":"Fischman","journal-title":"N. Engl. J. Med.","ISSN":"https:\/\/id.crossref.org\/issn\/0028-4793","issn-type":"print"},{"issue":"3","key":"2019100413554653800_c4","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1007\/s00392-002-1309-x","article-title":"Drug Eluting Stents: Initial Experiences","volume":"91","author":"Grube","journal-title":"Z. Kardiol.","ISSN":"https:\/\/id.crossref.org\/issn\/0300-5860","issn-type":"print"},{"issue":"7","key":"2019100413554653800_c5","doi-asserted-by":"publisher","first-page":"819","DOI":"10.1001\/jama.294.7.819","article-title":"Sirolimus-Eluting Stents Vs Paclitaxel-Eluting Stents in Patients With Coronary Artery Disease: Meta-Analysis of Randomized Trials","volume":"294","author":"Kastrati","journal-title":"JAMA, J. Am. Med. Assoc.","ISSN":"https:\/\/id.crossref.org\/issn\/0098-7484","issn-type":"print"},{"issue":"1","key":"2019100413554653800_c6","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1016\/j.jacc.2006.03.042","article-title":"Pathology of Drug-Eluting Stents in Humans: Delayed Healing and Late Thrombotic Risk","volume":"48","author":"Joner","journal-title":"J. Am. Coll. Cardiol.","ISSN":"https:\/\/id.crossref.org\/issn\/0735-1097","issn-type":"print"},{"issue":"21","key":"2019100413554653800_c7","doi-asserted-by":"publisher","first-page":"2649","DOI":"10.1161\/01.CIR.0000041632.02514.14","article-title":"Mechanism of Late In-Stent Restenosis After Implantation of a Paclitaxel Derivate-Eluting Polymer Stent System in Humans","volume":"106","author":"Virmani","journal-title":"Circulation","ISSN":"https:\/\/id.crossref.org\/issn\/0009-7322","issn-type":"print"},{"issue":"12","key":"2019100413554653800_c8","doi-asserted-by":"publisher","first-page":"1505","DOI":"10.1161\/01.CIR.0000029746.10018.36","article-title":"Sirolimus-Eluting Stents for the Treatment of Obstructive Superficial Femoral Artery Disease: Six-Month Results","volume":"106","author":"Duda","journal-title":"Circulation","ISSN":"https:\/\/id.crossref.org\/issn\/0009-7322","issn-type":"print"},{"issue":"3","key":"2019100413554653800_c9","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1097\/01.RVI.0000151260.74519.CA","article-title":"Sirolimus-Eluting Versus Bare Nitinol Stent for Obstructive Superficial Femoral Artery Disease: The Sirocco Ii Trial","volume":"16","author":"Duda","journal-title":"J. Vasc. Interv. Radiol.","ISSN":"https:\/\/id.crossref.org\/issn\/1051-0443","issn-type":"print"},{"issue":"1","key":"2019100413554653800_c10","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1186\/CVM-1-1-048","article-title":"Long-Term Outcome After Coronary Stenting","volume":"1","author":"Kastrati","journal-title":"Curr Control Trials Cardiovasc med"},{"issue":"4","key":"2019100413554653800_c11","first-page":"597","article-title":"Synthetic Absorbable Sutures","volume":"145","author":"Laufman","journal-title":"Surg. Gynecol. Obstet.","ISSN":"https:\/\/id.crossref.org\/issn\/0039-6087","issn-type":"print"},{"issue":"2","key":"2019100413554653800_c12","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1097\/00001665-199703000-00004","article-title":"Bioabsorbable Polymer Science for the Practicing Surgeon","volume":"8","author":"Pietrzak","journal-title":"J. Craniofac Surg.","ISSN":"https:\/\/id.crossref.org\/issn\/1049-2275","issn-type":"print"},{"issue":"6679","key":"2019100413554653800_c13","first-page":"5","article-title":"Drug Delivery and Targeting","volume":"392","author":"Langer","journal-title":"Nature (London)","ISSN":"https:\/\/id.crossref.org\/issn\/0028-0836","issn-type":"print"},{"issue":"2","key":"2019100413554653800_c14","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1002\/1097-4636(200105)55:2<141::AID-JBM1000>3.0.CO;2-J","article-title":"Biodegradable Polymeric Scaffolds for Musculoskeletal Tissue Engineering","volume":"55","author":"Agrawal","journal-title":"J. Biomed. Mater. Res.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-9304","issn-type":"print"},{"key":"2019100413554653800_c15","article-title":"Biodegradable Stents","volume-title":"Textbook of Interventional Cardiology","author":"Zidar"},{"issue":"7","key":"2019100413554653800_c16","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1016\/0142-9612(96)86738-X","article-title":"Role of Polymers in Improving the Results of Stenting in Coronary Arteries","volume":"17","author":"Peng","journal-title":"Biomaterials","ISSN":"https:\/\/id.crossref.org\/issn\/0142-9612","issn-type":"print"},{"issue":"5","key":"2019100413554653800_c17","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1243\/0954411041932782","article-title":"Degradation of Poly-L-Lactide: Part 1: In Vitro and In Vivo Physiological Temperature Degradation","volume":"218","author":"Weir","journal-title":"Proc. Inst. Mech. Eng., Part H: J. Eng. Med.","ISSN":"https:\/\/id.crossref.org\/issn\/0954-4119","issn-type":"print"},{"key":"2019100413554653800_c18","article-title":"Mechanisms of Polymer Degradation and Elimination","volume-title":"Handbook of Biodegradable Polymers","author":"Gopferich"},{"issue":"21","key":"2019100413554653800_c19","doi-asserted-by":"publisher","first-page":"4221","DOI":"10.1016\/S0142-9612(02)00170-9","article-title":"Why Degradable Polymers Undergo Surface Erosion or Bulk Erosion","volume":"23","author":"Burkersroda","journal-title":"Biomaterials","ISSN":"https:\/\/id.crossref.org\/issn\/0142-9612","issn-type":"print"},{"issue":"5","key":"2019100413554653800_c20","doi-asserted-by":"publisher","first-page":"931","DOI":"10.1016\/S0022-5096(97)00075-6","article-title":"Constitutive Modeling of the Large Strain Time-Dependent Behavior of Elastomers","volume":"46","author":"Bergstrom","journal-title":"J. Mech. Phys. Solids","ISSN":"https:\/\/id.crossref.org\/issn\/0022-5096","issn-type":"print"},{"issue":"3","key":"2019100413554653800_c21","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1122\/1.1879042","article-title":"Simulation of Fiber Spinning Including Flow-Induced Crystallization","volume":"49","author":"Kannan","journal-title":"J. Rheol.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-6055","issn-type":"print"},{"key":"2019100413554653800_c22","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/j.ijengsci.2008.07.001","article-title":"Diffusion of a Fluid Through a Spherical Elastic Solid Undergoing Large Deformations","volume":"47","author":"Soares","journal-title":"Int. J. Eng. Sci.","ISSN":"https:\/\/id.crossref.org\/issn\/0020-7225","issn-type":"print"},{"issue":"6","key":"2019100413554653800_c23","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1016\/0142-9612(84)90037-1","article-title":"The In Vivo and In Vitro Degradation of Poly(Glycolic Acid) Suture Material as a Function of Applied Strain","volume":"5","author":"Miller","journal-title":"Biomaterials","ISSN":"https:\/\/id.crossref.org\/issn\/0142-9612","issn-type":"print"},{"key":"2019100413554653800_c24","first-page":"111","volume-title":"Strain-Accelerated Hydrolytic Degradation of Synthetic Absorbable Sutures","author":"Chu"},{"issue":"3","key":"2019100413554653800_c25","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1016\/0267-6605(93)90001-N","article-title":"The Effect of Applied Strain on the Degradation of Absorbable Suture In Vitro","volume":"14","author":"Zhong","journal-title":"Clinical Materials"},{"issue":"3","key":"2019100413554653800_c26","doi-asserted-by":"publisher","first-page":"463","DOI":"10.1002\/jbm.a.10584","article-title":"Effect of Strain and Strain Rate on Fatigue-Accelerated Biodegradation of Polyurethane","volume":"66A","author":"Wiggins","journal-title":"J. Biomed. Mater. Res. Part A","ISSN":"https:\/\/id.crossref.org\/issn\/1549-3296","issn-type":"print"},{"issue":"4","key":"2019100413554653800_c27","doi-asserted-by":"publisher","first-page":"668","DOI":"10.1002\/jbm.a.20081","article-title":"Effect of Soft-Segment Chemistry on Polyurethane Biostability During In Vitro Fatigue Loading","volume":"68A","author":"Wiggins","journal-title":"J. Biomed. Mater. Res. Part A","ISSN":"https:\/\/id.crossref.org\/issn\/1549-3296","issn-type":"print"},{"issue":"1","key":"2019100413554653800_c28","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1515\/bmte.2002.47.s1a.503","article-title":"The Impact of Material Characteristics on the Mechanical Properties of a Poly(L-Lactide) Coronary Stent","volume":"47","author":"Grabow","journal-title":"Biomed. Tech.","ISSN":"https:\/\/id.crossref.org\/issn\/0013-5585","issn-type":"print"},{"issue":"7","key":"2019100413554653800_c29","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1163\/156856203322274932","article-title":"Theoretical and Experimental Evaluation of the Radial Force of Self-Expanding Braided Bioabsorbable Stents","volume":"14","author":"Nuutinen","journal-title":"J. Biomater. Sci., Polym. Ed.","ISSN":"https:\/\/id.crossref.org\/issn\/0920-5063","issn-type":"print"},{"issue":"3","key":"2019100413554653800_c30","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1002\/ccd.21176","article-title":"Promise and Challenges of Bioabsorbable Stents","volume":"70","author":"Waksman","journal-title":"Catheter Cardiovasc Interv"},{"issue":"1","key":"2019100413554653800_c31","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1007\/s13239-010-0005-7","article-title":"Biodegradable Stents: Biomechanical Modeling Challenges and Opportunities","volume":"1","author":"Moore","journal-title":"Cardiovascular Engineering and Technology"},{"issue":"17","key":"2019100413554653800_c32","doi-asserted-by":"publisher","first-page":"3575","DOI":"10.1016\/S0142-9612(02)00076-5","article-title":"Viscoelastic Memory and Self-Expansion of Self-Reinforced Bioabsorbable Stents","volume":"23","author":"V\u00e4limaa","journal-title":"Biomaterials","ISSN":"https:\/\/id.crossref.org\/issn\/0142-9612","issn-type":"print"},{"issue":"4","key":"2019100413554653800_c33","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1161\/01.CIR.102.4.399","article-title":"Initial and 6-Month Results of Biodegradable Poly-L-Lactic Acid Coronary Stents in Humans","volume":"102","author":"Tamai","journal-title":"Circulation","ISSN":"https:\/\/id.crossref.org\/issn\/0009-7322","issn-type":"print"},{"issue":"1","key":"2019100413554653800_c34","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1115\/1.1835349","article-title":"Mechanical Properties of Laser Cut Poly(L-Lactide) Micro-Specimens: Implications for Stent Design, Manufacture, and Sterilization","volume":"127","author":"Grabow","journal-title":"ASME J. Biomech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-0731","issn-type":"print"},{"issue":"1","key":"2019100413554653800_c35","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1002\/ccd.20895","article-title":"First-in-Human Implantation of a Fully Bioabsorbable Drug-Eluting Stent: The BVS Poly-L-Lactic Acid Everolimus-Eluting Coronary Stent","volume":"69","author":"Ormiston","journal-title":"Catheter Cardiovasc Interv"},{"issue":"3","key":"2019100413554653800_c36","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1016\/0142-9612(92)90068-Y","article-title":"Evaluation of Poly(L-Lactic Acid) as a Material for Intravascular Polymeric Stents","volume":"13","author":"Agrawal","journal-title":"Biomaterials","ISSN":"https:\/\/id.crossref.org\/issn\/0142-9612","issn-type":"print"},{"issue":"12","key":"2019100413554653800_c37","doi-asserted-by":"publisher","first-page":"1020","DOI":"10.1097\/00004424-199212000-00007","article-title":"Deformation Characteristics of a Bioabsorbable Intravascular Stent","volume":"27","author":"Agrawal","journal-title":"Invest. Radiol.","ISSN":"https:\/\/id.crossref.org\/issn\/0020-9996","issn-type":"print"},{"issue":"18","key":"2019100413554653800_c38","doi-asserted-by":"publisher","first-page":"3939","DOI":"10.1016\/j.biomaterials.2003.10.076","article-title":"Processing, Annealing and Sterilisation of Poly-L-Lactide","volume":"25","author":"Weir","journal-title":"Biomaterials","ISSN":"https:\/\/id.crossref.org\/issn\/0142-9612","issn-type":"print"},{"issue":"6","key":"2019100413554653800_c39","doi-asserted-by":"publisher","first-page":"667","DOI":"10.1114\/1.1575756","article-title":"Expandable Bioresorbable Endovascular Stent. I. Fabrication and Properties","volume":"31","author":"Su","journal-title":"Ann. Biomed. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0090-6964","issn-type":"print"},{"issue":"12","key":"2019100413554653800_c40","doi-asserted-by":"publisher","first-page":"2031","DOI":"10.1007\/s10439-007-9376-9","article-title":"A Biodegradable Slotted Tube Stent Based on Poly(L-Lactide) and Poly(4-Hydroxybutyrate) for Rapid Balloon-Expansion","volume":"35","author":"Grabow","journal-title":"Ann. Biomed. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0090-6964","issn-type":"print"},{"issue":"3","key":"2019100413554653800_c41","doi-asserted-by":"publisher","first-page":"1171","DOI":"10.1097\/01.ju.0000049229.12451.13","article-title":"Expansion and Fixation Properties of a New Braided Biodegradable Urethral Stent: An Experimental Study in the Rabbit","volume":"169","author":"Vaajanen","journal-title":"J Urol"},{"issue":"9","key":"2019100413554653800_c42","doi-asserted-by":"publisher","first-page":"1618","DOI":"10.1016\/j.ijplas.2007.02.007","article-title":"On the Shear and Bending of a Degrading Polymer Beam","volume":"23","author":"Rajagopal","journal-title":"Int. J. Plast.","ISSN":"https:\/\/id.crossref.org\/issn\/0749-6419","issn-type":"print"},{"issue":"4","key":"2019100413554653800_c43","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1016\/0749-6419(92)90056-I","article-title":"A Constitutive Equation for Nonlinear Solids Which Undergo Deformation Induced Microstructural Changes","volume":"8","author":"Rajagopal","journal-title":"Int. J. Plast.","ISSN":"https:\/\/id.crossref.org\/issn\/0749-6419","issn-type":"print"},{"key":"2019100413554653800_c44","unstructured":"Soares, J. S.\n          , 2008, \u201cConstitutive Modeling of Biodegradable Polymers for Application in Endovascular Stents,\u201d Ph.D. thesis, Department of Mechanical Engineering, Texas A&M University, College Station, TX."},{"issue":"3","key":"2019100413554653800_c45","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1097\/MAT.0b013e31816ba55a","article-title":"Constitutive Framework for Biodegradable Polymers With Applications to Biodegradable Stents","volume":"54","author":"Soares","journal-title":"ASAIO J.","ISSN":"https:\/\/id.crossref.org\/issn\/0162-1432","issn-type":"print"},{"key":"2019100413554653800_c46","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1007\/s10237-009-0168-z","article-title":"Deformation-Induced Hydrolysis of a Degradable Polymeric Cylindrical Annulus","volume":"9","author":"Soares","journal-title":"Biomech. Model. Mechanobiol.","ISSN":"https:\/\/id.crossref.org\/issn\/1617-7959","issn-type":"print"},{"key":"2019100413554653800_c47","doi-asserted-by":"publisher","first-page":"3032","DOI":"10.1016\/j.biomaterials.2010.01.008","article-title":"A Mixture Model for Water Uptake, Degradation, Erosion, and Drug Release From Polydisperse Polymeric Networks","volume":"31","author":"Soares","journal-title":"Biomaterials","ISSN":"https:\/\/id.crossref.org\/issn\/0142-9612","issn-type":"print"},{"issue":"1\u20133","key":"2019100413554653800_c48","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/S0141-3910(97)00148-1","article-title":"Large-Scale Production, Properties and Commercial Applications of Polylactic Acid Polymers","volume":"59","author":"Lunt","journal-title":"Polym. Degrad. Stab.","ISSN":"https:\/\/id.crossref.org\/issn\/0141-3910","issn-type":"print"},{"issue":"2","key":"2019100413554653800_c49","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1023\/A:1020200822435","article-title":"A Literature Review of Poly(Lactic Acid)","volume":"9","author":"Garlotta","journal-title":"J. Polym. Environ.","ISSN":"https:\/\/id.crossref.org\/issn\/1566-2543","issn-type":"print"},{"key":"2019100413554653800_c50","volume-title":"The Non-Linear Field Theories of Mechanics","author":"Truesdell"},{"issue":"6","key":"2019100413554653800_c51","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1089\/10763270360728233","article-title":"Technique Paper for Wet-Spinning Poly(L-Lactic Acid) and Poly(Dl-Lactide-Co-Glycolide) Monofilament Fibers","volume":"9","author":"Nelson","journal-title":"Tissue Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/1076-3279","issn-type":"print"},{"issue":"1","key":"2019100413554653800_c52","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1002\/(SICI)1097-4628(19960103)59:1<37::AID-APP6>3.0.CO;2-N","article-title":"Effect of Molecular Weight and Crystallinity on Poly(Lactic Acid) Mechanical Properties","volume":"59","author":"Perego","journal-title":"J. Appl. Polym. Sci.","ISSN":"https:\/\/id.crossref.org\/issn\/0021-8995","issn-type":"print"},{"issue":"5","key":"2019100413554653800_c53","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1115\/1.2246236","article-title":"Effects of Stent Design Parameters on Normal Artery Wall Mechanics","volume":"128","author":"Bedoya","journal-title":"ASME J. Biomech. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-0731","issn-type":"print"},{"issue":"5","key":"2019100413554653800_c54","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1007\/s11517-007-0180-3","article-title":"Stented Artery Biomechanics and Device Design Optimization","volume":"45","author":"Timmins","journal-title":"Med. Biol. Eng. Comput.","ISSN":"https:\/\/id.crossref.org\/issn\/0140-0118","issn-type":"print"},{"issue":"I","key":"2019100413554653800_c55","doi-asserted-by":"publisher","first-page":"I1","DOI":"10.1583\/08-2605.1","article-title":"Biomechanical Issues in Endovascular Device Design","volume":"16","author":"Moore","journal-title":"J. Endovasc. Ther.","ISSN":"https:\/\/id.crossref.org\/issn\/1526-6028","issn-type":"print"},{"key":"2019100413554653800_c56","doi-asserted-by":"crossref","volume-title":"Introduction to Continuum Damage Mechanics","author":"Kachanov","DOI":"10.1007\/978-94-017-1957-5"},{"issue":"1988","key":"2019100413554653800_c57","doi-asserted-by":"publisher","first-page":"2861","DOI":"10.1098\/rspa.1999.0431","article-title":"A Pseudo-Elastic Model for the Mullins Effect in Filled Rubber","volume":"455","author":"Ogden","journal-title":"Proc. R. Soc. London, Ser. A","ISSN":"https:\/\/id.crossref.org\/issn\/0950-1207","issn-type":"print"},{"issue":"2","key":"2019100413554653800_c58","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1122\/1.549591","article-title":"The Stress Clock Function in Viscoelasticity","volume":"24","author":"Bernstein","journal-title":"J. Rheol.","ISSN":"https:\/\/id.crossref.org\/issn\/0148-6055","issn-type":"print"},{"issue":"4","key":"2019100413554653800_c59","doi-asserted-by":"publisher","first-page":"393","DOI":"10.1177\/108128659600100403","article-title":"The Pressurized Cylinder Problem for Nonlinear Viscoelastic Materials With a Strain Clock","volume":"1","author":"Wineman","journal-title":"Math. Mech. Solids","ISSN":"https:\/\/id.crossref.org\/issn\/1081-2865","issn-type":"print"},{"issue":"10","key":"2019100413554653800_c60","doi-asserted-by":"publisher","first-page":"1547","DOI":"10.1016\/j.ijnonlinmec.2003.09.001","article-title":"A Note on Viscoelastic Materials That Can Age","volume":"39","author":"Rajagopal","journal-title":"Int. J. Non-Linear Mech.","ISSN":"https:\/\/id.crossref.org\/issn\/0020-7462","issn-type":"print"},{"key":"2019100413554653800_c61","doi-asserted-by":"crossref","volume-title":"Cardiovascular Solid Mechanics: Cells, Tissues, and Organs","author":"Humphrey","DOI":"10.1007\/978-0-387-21576-1"},{"key":"2019100413554653800_c62","article-title":"Stress-Strain History Relations of Soft Tissues in Simple Elongation","volume-title":"Biomechanics, Its Foundations and Objectives","author":"Fung"},{"issue":"4","key":"2019100413554653800_c63","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1007\/BF00049187","article-title":"Failure of Ellipticity and Emergence of Discontinuous Deformation Gradients in Plane Finite Elastostatics","volume":"8","author":"Knowles","journal-title":"J. Elast.","ISSN":"https:\/\/id.crossref.org\/issn\/0374-3535","issn-type":"print"},{"key":"2019100413554653800_c64","volume-title":"The Finite Element Method. Solid and Fluid Mechanics, Dynamics and Nonlinearity","author":"Zienkiewicz"},{"key":"2019100413554653800_c65","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1146\/annurev.bioeng.10.061807.160439","article-title":"Intracranial and Abdominal Aortic Aneurysms: Similarities, Differences, and Need for a New Class of Computational Models","volume":"10","author":"Humphrey","journal-title":"Annu. Rev. Biomed. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/1523-9829","issn-type":"print"}],"container-title":["Journal of Medical Devices"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/asmedigitalcollection.asme.org\/medicaldevices\/article-pdf\/doi\/10.1115\/1.4002759\/5928786\/041007_1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/asmedigitalcollection.asme.org\/medicaldevices\/article-pdf\/doi\/10.1115\/1.4002759\/5928786\/041007_1.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,4]],"date-time":"2019-10-04T17:55:56Z","timestamp":1570211756000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/medicaldevices\/article\/doi\/10.1115\/1.4002759\/432577\/Modeling-of-DeformationAccelerated-Breakdown-of"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,12,1]]},"references-count":65,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2010,12,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4002759","relation":{},"ISSN":["1932-6181","1932-619X"],"issn-type":[{"value":"1932-6181","type":"print"},{"value":"1932-619X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,12,1]]},"article-number":"041007"}}