{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,13]],"date-time":"2026-11-13T03:14:10Z","timestamp":1794539650496,"version":"4.9.1"},"reference-count":38,"publisher":"ASME International","issue":"2","license":[{"start":{"date-parts":[[2024,12,11]],"date-time":"2024-12-11T00:00:00Z","timestamp":1733875200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.asme.org\/publications-submissions\/publishing-information\/legal-policies"}],"content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Traditionally, data centers (DC) have used air cooling for IT equipment, but as graphics processing units (GPUs) evolve, they demand more power and sophisticated cooling. Aiming for efficiency, direct liquid cooling (DLC) emerges as a promising solution. We evaluated the effectiveness of DLC versus traditional air cooling on a Microsoft G50 GPU server performing artificial intelligence\/machine learning (AI\/ML) tasks. The results indicated that DLC greatly enhances GPU performance, increases efficiency by 2.7% in Gflops\/s, cuts power usage by 12%, reduces execution times by up to 6.22%, and lowers chip temperatures by 20\u2009\u00b0C compared to air cooling. Our research develops an overall performance metric that considers data center, hardware, and chip levels, concluding that DLC is extremely beneficial for AI workloads, increasing energy savings and balancing performance with power requirements.<\/jats:p>","DOI":"10.1115\/1.4067136","type":"journal-article","created":{"date-parts":[[2024,11,13]],"date-time":"2024-11-13T06:28:56Z","timestamp":1731479336000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":22,"title":["Understanding the Impact of Data Center Liquid Cooling on Energy and Performance of Machine Learning and Artificial Intelligence Workloads"],"prefix":"10.1115","volume":"147","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2858-3557","authenticated-orcid":false,"given":"Bharath","family":"Ramakrishnan","sequence":"first","affiliation":[{"name":"Microsoft Corporation , Redmond, WA 98052"},{"id":[{"id":"https:\/\/ror.org\/00d0nc645","id-type":"ROR","asserted-by":"publisher"}],"name":"Microsoft (United States)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cam","family":"Turner","sequence":"additional","affiliation":[{"name":"Microsoft Corporation , Redmond, WA 98052"},{"id":[{"id":"https:\/\/ror.org\/00d0nc645","id-type":"ROR","asserted-by":"publisher"}],"name":"Microsoft (United States)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Husam","family":"Alissa","sequence":"additional","affiliation":[{"name":"Microsoft Corporation , Redmond, WA 98052"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dennis","family":"Trieu","sequence":"additional","affiliation":[{"name":"Microsoft Corporation , Redmond, WA 98052"},{"id":[{"id":"https:\/\/ror.org\/00d0nc645","id-type":"ROR","asserted-by":"publisher"}],"name":"Microsoft (United States)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Felipe","family":"Rivera","sequence":"additional","affiliation":[{"name":"Microsoft Corporation , Redmond, WA 98052"},{"id":[{"id":"https:\/\/ror.org\/00d0nc645","id-type":"ROR","asserted-by":"publisher"}],"name":"Microsoft (United States)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luke","family":"Melton","sequence":"additional","affiliation":[{"name":"Microsoft Corporation , Redmond, WA 98052"},{"id":[{"id":"https:\/\/ror.org\/00d0nc645","id-type":"ROR","asserted-by":"publisher"}],"name":"Microsoft (United States)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muralikrishna","family":"Rao","sequence":"additional","affiliation":[{"name":"Microsoft Corporation , Redmond, WA 98052"},{"id":[{"id":"https:\/\/ror.org\/00d0nc645","id-type":"ROR","asserted-by":"publisher"}],"name":"Microsoft (United States)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sruti","family":"Chigullapalli","sequence":"additional","affiliation":[{"name":"ZT Systems , Seattle, WA 98104"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tatek","family":"Getachew","sequence":"additional","affiliation":[{"name":"ZT Systems , Santa Clara, CA 95054"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vladimir","family":"Prodanovic","sequence":"additional","affiliation":[{"name":"Nvidia , South Holland 1118 CZ, The Netherlands"},{"id":[{"id":"https:\/\/ror.org\/00d0nc645","id-type":"ROR","asserted-by":"publisher"}],"name":"Microsoft (United States)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Lankston","sequence":"additional","affiliation":[{"name":"Stealth Startup , Bellevue, WA 98004"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Belady","sequence":"additional","affiliation":[{"name":"Mercer Island, WA 98040"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vaidehi","family":"Oruganti","sequence":"additional","affiliation":[{"name":"Redmond, WA 98052"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"33","published-online":{"date-parts":[[2024,12,11]]},"reference":[{"key":"2024121310342892200_bib1","first-page":"13","article-title":"Cloud Computing and Covid19","volume-title":"ICPSC","year":"2021"},{"key":"2024121310342892200_bib2","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1007\/978-981-16-2972-3_3","article-title":"Remote Patient Monitoring Using IoT, Cloud Computing and AI","volume":"209","year":"2021","journal-title":"Hybrid Artif. Intell. IoT Healthcare"},{"key":"2024121310342892200_bib3","doi-asserted-by":"crossref","first-page":"100514","DOI":"10.1016\/j.iot.2022.100514","article-title":"AI for Next Generation Computing: Emerging Trends and Future Directions","volume":"19","year":"2022","journal-title":"Internet Things"},{"key":"2024121310342892200_bib4","unstructured":"SuperMicro, 2023, \u201cDatasheet-NVIDIA-MGX1\u2009U-GH200-Grace-Hopper-Systems.pdf,\u201d SuperMicro, San Jose, CA, accessed Nov. 26, 2024, https:\/\/www.supermicro.com\/datasheet\/datasheet-NVIDIA-MGX-1U-GH200-Grace-Hopper-Systems.pdf"},{"key":"2024121310342892200_bib5","first-page":"23","article-title":"Enabling Distributed Generation Powered Sustainable High-Performance Data Center","volume-title":"HPCA","year":"2013"},{"key":"2024121310342892200_bib6","unstructured":"Digital Infrastructure, 2023, \u201cHow Data Centers Are Enabling Artificial Intelligence (AI),\u201d Digital Infrastructure, New York, accessed Nov. 26, 2024, https:\/\/dgtlinfra.com\/data-centers-artificial-intelligence-ai\/"},{"key":"2024121310342892200_bib7","first-page":"5","article-title":"Designing an Energy Efficient HPC Supercomputing Center","volume-title":"Proceedings of the 48th International Conference on Parallel Processing","year":"2019"},{"issue":"5","key":"2024121310342892200_bib8","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1109\/JSSC.1974.1050511","article-title":"Design of Ion-Implanted MOSFET's With Very Small Physical Dimensions","volume":"9","year":"1974","journal-title":"IEEE J. Solid-State Circuits"},{"issue":"1","key":"2024121310342892200_bib9","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1109\/TCAD.2018.2878168","article-title":"Machine Learning for Power, Energy, and Thermal Management on Multicore Processors: A Survey","volume":"39","year":"2020","journal-title":"IEEE Trans. Comput.-Aided Des. Integr. Circuits Syst."},{"issue":"6481","key":"2024121310342892200_bib10","doi-asserted-by":"crossref","first-page":"984","DOI":"10.1126\/science.aba3758","article-title":"Recalibrating Global Data Center Energy-Use Estimates","volume":"367","year":"2020","journal-title":"Science"},{"key":"2024121310342892200_bib11","doi-asserted-by":"crossref","first-page":"1255","DOI":"10.1016\/j.egypro.2015.07.178","article-title":"Data Center Energy and Cost Saving Evaluation","volume":"75","year":"2015","journal-title":"Energy Proc."},{"key":"2024121310342892200_bib12","article-title":"Power Usage Effectiveness Analysis of a High-Density Air-Liquid Hybrid Cooled Data Center","volume-title":"ASME","year":"2022"},{"key":"2024121310342892200_bib13","volume-title":"Emergence and Expansion of Liquid Cooling in Mainstream Datacenters","author":"ASHRAE Technical Committee 9.9, Mission Critical Facilities","year":"2021"},{"key":"2024121310342892200_bib14","first-page":"1","article-title":"Evaluating the Limits of Rear Door Heat Exchanger in Datacenters","volume-title":"Open Compute Project","year":"2023"},{"issue":"1","key":"2024121310342892200_bib15","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1109\/TCAPT.2003.811465","article-title":"Heat Rejection Limits of Air Cooled Plane Fin Heat Sinks for Computer Cooling","volume":"26","year":"2003","journal-title":"Compon. Packag. Technol., IEEE Trans."},{"key":"2024121310342892200_bib16","doi-asserted-by":"crossref","first-page":"122122","DOI":"10.1016\/j.applthermaleng.2023.122122","article-title":"Experimental Evaluation of Direct-to-Chip Cold Plate Liquid Cooling for High-Heat-Density Data Centers","volume":"239","year":"2024","journal-title":"Appl. Therm. Eng."},{"key":"2024121310342892200_bib17","first-page":"412","article-title":"Understanding HPC Benchmark Performance on Intel Broadwell and Cascade Lake Processors","volume-title":"High Performance Computing","year":"2020"},{"key":"2024121310342892200_bib18","article-title":"GSMA 2022","author":"Global Speciale Mobile Association","year":"2022"},{"key":"2024121310342892200_bib19","volume-title":"Greenhouse Gas Emissions for the Information and Communications Technology Sector 2020","author":"ITU","year":"2020"},{"issue":"4","key":"2024121310342892200_bib20","doi-asserted-by":"crossref","first-page":"041005","DOI":"10.1115\/1.4044130","article-title":"Thermal Analysis of Cold Plate for Direct Liquid Cooling of High Performance Servers","volume":"141","year":"2019","journal-title":"ASME J. Electron. Packag."},{"issue":"2","key":"2024121310342892200_bib21","doi-asserted-by":"crossref","first-page":"020904","DOI":"10.1115\/1.4049928","article-title":"Experimental Characterization of Two-Phase Cold Plates Intended for High-Density Data Center Servers Using a Dielectric Fluid","volume":"143","year":"2021","journal-title":"ASME J. Electron. Packag."},{"issue":"5","key":"2024121310342892200_bib22","doi-asserted-by":"crossref","first-page":"2485","DOI":"10.1007\/s00542-017-3688-y","article-title":"Effects of Various Inlet\/Outlet Positions and Header Forms on Flow Distribution and Thermal Performance in Microchannel Heat Sink","volume":"24","year":"2018","journal-title":"Microsyst. Technol."},{"key":"2024121310342892200_bib23","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1016\/j.applthermaleng.2019.02.030","article-title":"Effects of the Location of the Inlet and Outlet on Heat Transfer Performance in Pin Fin CPU Heat Sink","volume":"151","year":"2019","journal-title":"Appl. Therm. Eng."},{"issue":"2","key":"2024121310342892200_bib24","doi-asserted-by":"crossref","first-page":"021010","DOI":"10.1115\/1.4031932","article-title":"Modular Design for a Single-Phase Manifold Mini\/Microchannel Cold Plate","volume":"8","year":"2016","journal-title":"ASME J. Therm. Sci. Eng. Appl."},{"issue":"12","key":"2024121310342892200_bib25","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1080\/01457630902837343","article-title":"Liquid Cooled Cold Plates for Industrial High-power Electronic Devices\u2014Thermal Design and Manufacturing Considerations","volume":"30","year":"2009","journal-title":"Heat Transfer Eng."},{"key":"2024121310342892200_bib26","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1016\/j.future.2021.07.031","article-title":"Energy-Conscious Optimization of Edge Computing Through Deep Reinforcement Learning and Two-Phase Immersion Cooling","volume":"125","year":"2021","journal-title":"Future Gener. Comput. Syst."},{"key":"2024121310342892200_bib27","first-page":"17","article-title":"DeiC Super Computing 2019 Report","volume-title":"Fact Finding Tour at Super Computing 19","year":"2020"},{"issue":"12","key":"2024121310342892200_bib28","doi-asserted-by":"crossref","first-page":"9509","DOI":"10.1016\/j.aej.2022.02.059","article-title":"The Immersion Cooling Technology: Current and Future Development in Energy Saving","volume":"61","year":"2022","journal-title":"Alexandria Eng. J."},{"key":"2024121310342892200_bib29","first-page":"623","article-title":"Cost-Efficient Overclocking in Immersion-Cooled Datacenters","volume-title":"ISCA","year":"2021"},{"issue":"10","key":"2024121310342892200_bib30","doi-asserted-by":"crossref","first-page":"1703","DOI":"10.1109\/TCPMT.2021.3106026","article-title":"CPU Overclocking: A Performance Assessment of Air, Cold Plates, and Two-Phase Immersion Cooling","volume":"11","year":"2021","journal-title":"IEEE Trans. Compon., Packag. Manuf. Technol."},{"key":"2024121310342892200_bib31","article-title":"Additive Manufacturing of Capillary Driven Two-Phase Cold Plates","volume-title":"HTFF 174","year":"2022"},{"key":"2024121310342892200_bib32","article-title":"Energy Efficiency Analyses and Comparison of Air and Water Cooled High Performance Servers","volume-title":"ASME","year":"2009"},{"key":"2024121310342892200_bib33","article-title":"L2A CDUs Performance and Considerations for Server Rooms Upgrade With Conventional Air Conditioning","volume-title":"ASME","year":"2023"},{"key":"2024121310342892200_bib34","first-page":"9","article-title":"Case Study of a Data Centre Using Enclosed, Immersed, Direct Liquid-Cooled Servers","volume-title":"SEMITHERM","year":"2014"},{"key":"2024121310342892200_bib35","first-page":"18","article-title":"Server Liquid Cooling With Chiller-Less Data Center Design to Enable Significant Energy Savings","volume-title":"SEMI-THERM","year":"2012"},{"key":"2024121310342892200_bib36","first-page":"18","article-title":"Experimental Investigation of Water-Cooled Server Microprocessors and Memory Devices in an Energy Efficient Chiller-Less Data Center","volume-title":"SEMI-THERM","year":"2012"},{"issue":"7","key":"2024121310342892200_bib37","first-page":"45","article-title":"Moderating the Impact of Integrating Water-Cooled Servers Into Data Centers","volume":"61","year":"2019","journal-title":"ASHRAE J."},{"issue":"5","key":"2024121310342892200_bib38","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1109\/EDL.1981.25367","article-title":"High-Performance Heat Sinking for VLSI","volume":"2","year":"1981","journal-title":"IEEE Electron Device Lett."}],"container-title":["Journal of Electronic Packaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/asmedigitalcollection.asme.org\/electronicpackaging\/article-pdf\/147\/2\/021003\/7415279\/ep_147_02_021003.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/asmedigitalcollection.asme.org\/electronicpackaging\/article-pdf\/147\/2\/021003\/7415279\/ep_147_02_021003.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,13]],"date-time":"2024-12-13T05:34:47Z","timestamp":1734068087000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/electronicpackaging\/article\/147\/2\/021003\/1208659\/Understanding-the-Impact-of-Data-Center-Liquid"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,11]]},"references-count":38,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025,6,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4067136","relation":{},"ISSN":["1043-7398","1528-9044"],"issn-type":[{"value":"1043-7398","type":"print"},{"value":"1528-9044","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,11]]},"article-number":"021003"}}