{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T07:20:01Z","timestamp":1767165601859,"version":"build-2238731810"},"update-to":[{"DOI":"10.1115\/gt2025-151820","type":"new_version","label":"New version","source":"publisher","updated":{"date-parts":[[2025,10,15]],"date-time":"2025-10-15T00:00:00Z","timestamp":1760486400000}}],"reference-count":35,"publisher":"ASME International","issue":"2","license":[{"start":{"date-parts":[[2025,10,15]],"date-time":"2025-10-15T00:00:00Z","timestamp":1760486400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.asme.org\/publications-submissions\/publishing-information\/legal-policies"}],"content-domain":{"domain":["asmedigitalcollection.asme.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,2,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Nowadays, heat pumps are playing a key role in reducing carbon footprint of heating and cooling systems. In large-scale industrial applications, centrifugal compressors are often used under variable conditions and at low mass flowrate, where instabilities may occur. To investigate these aspects in refrigerant closed-loop systems, Carrier supplied the University of Genoa with a small-size chiller test rig. This rig is equipped with a vaned diffuser high-speed centrifugal compressor driven by a variable-speed motor, enabling experimental investigation in a wide operating range. This experimental activity investigates surge transients in centrifugal compressors by employing a comprehensive approach that integrates pressure measurements using high-frequency piezoresistive pressure transducers with dynamic vibro-acoustic response data. Different signal processing techniques in time and frequency domain were applied to investigate the different system response components, and to separate the overall signal into individual contributions to better identify the rise of anomalous fluid-dynamic conditions. A coherence analysis was also applied, and different types of system responses were considered, including the function computation between physically nonhomogeneous system responses such as inflow pressure and structural vibrational signals. Additionally, the acquired uniform-time-increment signals were resampled at constant increments of the compressor shaft angle to obtain angle-domain sampled data. This allowed for the computation of synchronously averaged response spectra both in linear and energy modes. Statistical techniques, such as skewness and kurtosis, were also utilized for the detection of signals with strong additional noise, where transient and nondeterministic contents may arise as the compressor approaches unstable conditions. The obtained results provide promising diagnostic and predictive paths to detect compressor instabilities in closed-loop heat pump systems.<\/jats:p>","DOI":"10.1115\/1.4069461","type":"journal-article","created":{"date-parts":[[2025,8,21]],"date-time":"2025-08-21T17:05:26Z","timestamp":1755795926000},"update-policy":"https:\/\/doi.org\/10.1115\/crossmarkpolicy-asme","source":"Crossref","is-referenced-by-count":0,"title":["Experimental Investigation on the Dynamic Response of a Vaned Diffuser Compressor in Innovative Heat-Pump Systems"],"prefix":"10.1115","volume":"148","author":[{"given":"Paolo","family":"Silvestri","sequence":"first","affiliation":[{"name":"University of Genoa, DIME, Thermochemical Power Group (TPG), Genoa 16145, Italy"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3928-1482","authenticated-orcid":false,"given":"Marco Martins","family":"Afonso","sequence":"additional","affiliation":[{"name":"SIT Technologies, Genoa 16145, Italy"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4726-9747","authenticated-orcid":false,"given":"Carlo Alberto","family":"Niccolini Marmont du Haut Champ","sequence":"additional","affiliation":[{"name":"University of Genoa, DIME, Thermochemical Power Group (TPG), Genoa 16145, Italy"},{"id":[{"id":"https:\/\/ror.org\/0107c5v14","id-type":"ROR","asserted-by":"publisher"}],"name":"University of Genoa"}]},{"given":"Federico","family":"Reggio","sequence":"additional","affiliation":[{"name":"University of Genoa, DIME, Thermochemical Power Group (TPG), Genoa 16145, Italy"},{"id":[{"id":"https:\/\/ror.org\/0107c5v14","id-type":"ROR","asserted-by":"publisher"}],"name":"University of Genoa"}]},{"given":"Alberto","family":"Traverso","sequence":"additional","affiliation":[{"name":"University of Genoa, DIME, Thermochemical Power Group (TPG), Genoa 16145, Italy"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-0676-6820","authenticated-orcid":false,"given":"Chaitanya","family":"Halbe","sequence":"additional","affiliation":[{"name":"Carrier Corporation, East Syracuse , NY 13057"}]}],"member":"33","published-online":{"date-parts":[[2025,10,15]]},"reference":[{"key":"2025101610100662900_bib1","unstructured":"Ritchie, H., Roser, M., and Rosado, P., 2020, \u201cEnergy,\u201d Our World in Data, Oxford, UK, accessed Sep. 6, 2022, https:\/\/ourworldindata.org\/energy"},{"key":"2025101610100662900_bib2","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1038\/s41370-017-0014-9","article-title":"Energy Savings, Emission Reductions, and Health co-Benefits of the Green Building Movement","volume":"28","year":"2018","journal-title":"J. Expo. Sci. Environ. Epidemiol."},{"key":"2025101610100662900_bib3","unstructured":"European Commission, 2016, \u201cAn EU Strategy on Heating and Cooling,\u201d Brussels, Belgium, accessed Dec. 11, 2024, https:\/\/www.europarl.europa.eu\/legislative-train\/package-energy-efficiency\/file-eu-strategy-on-heating-and-cooling"},{"issue":"12","key":"2025101610100662900_bib4","doi-asserted-by":"crossref","first-page":"3611","DOI":"10.1016\/j.apenergy.2010.06.014","article-title":"Advances in Heat Pump Systems: A Review","volume":"87","year":"2010","journal-title":"Appl Energy"},{"key":"2025101610100662900_bib5","first-page":"605","article-title":"Heat Pumps","volume-title":"Landolt-B\u00f6rnstein - Group VIII Advanced Materials and Technologies, Renewable Energy","author":"Heinloth","year":"2006"},{"key":"2025101610100662900_bib6","doi-asserted-by":"crossref","first-page":"985","DOI":"10.1016\/j.energy.2018.03.166","article-title":"High Temperature Heat Pumps: Market Overview, State of the Art, Research Status, Refrigerants, and Application Potentials","volume":"152","year":"2018","journal-title":"Energy"},{"key":"2025101610100662900_bib7","article-title":"Gas Turbine Combined Cycle Range Enhancer\u2014Part 1: Cyber-Physical Setup","volume-title":"ASME","year":"2022"},{"issue":"12","key":"2025101610100662900_bib8","doi-asserted-by":"crossref","first-page":"121013","DOI":"10.1115\/1.4055495","article-title":"Gas Turbine Combined Cycle Range Enhancer - Part 2: Performance Demonstration","volume":"144","year":"2022","journal-title":"ASME J. Eng. Gas Turbines Power"},{"key":"2025101610100662900_bib9","first-page":"03014","article-title":"Control Strategies for Solar Fa\u00e7ade Panels Coupled With a Heat Pump and Interacting With a District Heating Network","year":"2019"},{"key":"2025101610100662900_bib10","doi-asserted-by":"crossref","first-page":"119466","DOI":"10.1016\/j.apenergy.2022.119466","article-title":"Electrical Hybrid Heat Pumps Assisted by Natural Gas Boilers: A Review","volume":"322","year":"2022","journal-title":"Appl. Energy"},{"issue":"2","key":"2025101610100662900_bib11","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1016\/j.rser.2006.10.003","article-title":"Ground-Source Heat Pumps Systems and Applications","volume":"12","year":"2008","journal-title":"Renew. Sust. Energy Rev."},{"key":"2025101610100662900_bib12","first-page":"100238","article-title":"Heat Pump Integration in a Real Poly-Generative Energy District: A Techno-Economic Analysis","volume":"15","year":"2022","journal-title":"Energy Convers. Manage. X"},{"key":"2025101610100662900_bib13","doi-asserted-by":"crossref","first-page":"121002","DOI":"10.1115\/1.4048910","article-title":"Signal Processing Techniques to Detect Centrifugal Compressors Instabilities in Large Volume Power Plants","volume":"142","year":"2020","journal-title":"ASME J. Eng. Gas Turbines Power"},{"issue":"7","key":"2025101610100662900_bib14","doi-asserted-by":"crossref","first-page":"071014","DOI":"10.1115\/1.4049855","article-title":"Incipient Surge Detection in Large Volume Energy Systems Based on Wigner-Ville Distribution Evaluated on Vibration Signals","volume":"143","year":"2021","journal-title":"ASME J. Eng. Gas Turbines Power"},{"key":"2025101610100662900_bib15","article-title":"Experimental Investigation on the Dynamic Response of a Turbocharger Centrifugal Compressor in Surge Transitions","volume-title":"ASME J. Eng. Gas Turbines Power","year":"2024"},{"issue":"4","key":"2025101610100662900_bib16","first-page":"2615","article-title":"Modeling of Surge Characteristics in Turbo Heat Pumps","volume":"133","year":"2011","journal-title":"ASME J. Turbomach."},{"key":"2025101610100662900_bib17","first-page":"1","article-title":"An Analysis of Heat Transfer Effects on Surge Characteristics in Turbo Heat Pumps","volume-title":"International Compressor Engineering Conference","year":"2010"},{"key":"2025101610100662900_bib18","first-page":"60","article-title":"Avoiding Centrifugal Chiller Surge","year":"2018","journal-title":"ASHRAE J."},{"issue":"2","key":"2025101610100662900_bib19","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1115\/1.3446138","article-title":"Surge and Rotating Stall in Axial Flow Compressors\u2014Part I: Theoretical Compression System Model","volume":"98","year":"1976","journal-title":"ASME J. Eng. Power"},{"issue":"8","key":"2025101610100662900_bib20","first-page":"181001","article-title":"Surge Onset in Turbo Heat Pumps","volume":"136","year":"2014","journal-title":"ASME J. Turbomach."},{"key":"2025101610100662900_bib21","first-page":"022605","article-title":"Experimental Investigation of Stall and Surge in a Multistage Compressor","volume-title":"ASME J. Eng. Gas Turbines Power"},{"issue":"4","key":"2025101610100662900_bib22","doi-asserted-by":"crossref","first-page":"710","DOI":"10.1115\/1.2929138","article-title":"Dynamic Control of Centrifugal Compressor Surge Using Tailored Structures","volume":"113","year":"1991","journal-title":"ASME J. Turbomach."},{"issue":"11","key":"2025101610100662900_bib23","first-page":"111014","article-title":"Compressor Surge Precursors for a Turbocharger Coupled to a Pressure Vessel","volume":"144","year":"2022","journal-title":"ASME J. Eng. Gas Turbines Power"},{"issue":"8","key":"2025101610100662900_bib24","doi-asserted-by":"crossref","first-page":"2117","DOI":"10.1007\/s11012-022-01540-6","article-title":"Operation Extension in Gas Turbine-Based Advanced Cycles With a Surge Prevention Tool","volume":"57","year":"2022","journal-title":"Meccanica"},{"issue":"9","key":"2025101610100662900_bib25","doi-asserted-by":"crossref","first-page":"092605","DOI":"10.1115\/1.4038765","article-title":"Experimental Investigation of Vibrational and Acoustic Phenomena for Detecting the Stall and Surge of a Multistage Compressor","volume":"140","year":"2018","journal-title":"ASME J. Eng. Gas Turbines Power"},{"key":"2025101610100662900_bib26","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/j.expthermflusci.2014.01.002","article-title":"Identification of phenomena preceding blower Surge by Means of Pressure Spectral Maps","volume":"54","year":"2014","journal-title":"Exp. Therm. Fluid Sci."},{"key":"2025101610100662900_bib27","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1016\/j.jsv.2017.10.003","article-title":"Investigation of turbocharger compressor surge Inception by Means of an Acoustic Two-Port Model","volume":"412","year":"2018","journal-title":"J. Sound Vib."},{"issue":"2","key":"2025101610100662900_bib28","doi-asserted-by":"crossref","first-page":"021018","DOI":"10.1115\/1.4066363","article-title":"Compressor Surge Identification in Innovative Heat-Pump Systems Equipped by Vaned Diffuser Centrifugal Compressor","volume":"147","year":"2025","journal-title":"ASME J. Eng. Gas Turbines Power"},{"key":"2025101610100662900_bib29","volume-title":"Discrete-Time Signal Processing","year":"1999"},{"key":"2025101610100662900_bib30","volume-title":"Random Data: Analysis and Measurement Procedures","year":"2011"},{"issue":"4","key":"2025101610100662900_bib31","doi-asserted-by":"crossref","first-page":"1087","DOI":"10.1016\/j.ymssp.2010.07.016","article-title":"The Synchronous (Time Domain) Average Revisited","volume":"25","year":"2011","journal-title":"Mech. Syst. Signal Process"},{"issue":"2","key":"2025101610100662900_bib32","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1006\/mssp.1996.0056","article-title":"Analysis of Computed Order Tracking","volume":"11","year":"1997","journal-title":"Mech. Syst. Signal Process"},{"issue":"2","key":"2025101610100662900_bib33","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1016\/j.ymssp.2004.09.001","article-title":"The Spectral Kurtosis: A Useful Tool for Characterizing Non-Stationary Signals","volume":"20","year":"2006","journal-title":"Mech. Syst. Signal Process"},{"issue":"2","key":"2025101610100662900_bib34","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1016\/j.ymssp.2004.09.002","article-title":"The Spectral Kurtosis: Application to the Vibratory Surveillance and Diagnostics of Rotating Machines","volume":"20","year":"2006","journal-title":"Mech. Syst. Signal Process"},{"issue":"1","key":"2025101610100662900_bib35","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/j.ymssp.2005.12.002","article-title":"Fast Computation of the Kurtogram for the Detection of Transient Faults","volume":"21","year":"2007","journal-title":"Mech. Syst. Signal Process"}],"container-title":["Journal of Engineering for Gas Turbines and Power"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/asmedigitalcollection.asme.org\/gasturbinespower\/article-pdf\/148\/2\/021017\/7530932\/gtp-25-1330.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/asmedigitalcollection.asme.org\/gasturbinespower\/article-pdf\/148\/2\/021017\/7530932\/gtp-25-1330.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T14:10:23Z","timestamp":1760623823000},"score":1,"resource":{"primary":{"URL":"https:\/\/asmedigitalcollection.asme.org\/gasturbinespower\/article\/148\/2\/021017\/1221109\/Experimental-Investigation-on-the-Dynamic-Response"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,15]]},"references-count":35,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,2,1]]}},"URL":"https:\/\/doi.org\/10.1115\/1.4069461","relation":{},"ISSN":["0742-4795","1528-8919"],"issn-type":[{"value":"0742-4795","type":"print"},{"value":"1528-8919","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,15]]},"article-number":"021017"}}