{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T21:58:30Z","timestamp":1790891910251,"version":"4.1.0"},"reference-count":23,"publisher":"SPIE-Intl Soc Optical Eng","issue":"01","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Electron. Imag."],"published-print":{"date-parts":[[2002,1,1]]},"abstract":"<jats:p>Thanks to its ability to yield functionally rather than anatomically-based information, the single photon emission computed tomography (SPECT) imagery technique has become a great help in the diagnostic of cerebrovascular diseases which are the third most common cause of death in the USA and Europe. Nevertheless, SPECT images are very blurred and consequently their interpretation is difficult. In order to improve the spatial resolution of these images and then to facilitate their interpretation by the clinician, we propose to implement and to compare the effectiveness of different existing \u2018\u2018blind\u2019\u2019 or \u2018\u2018supervised\u2019\u2019 deconvolution methods. To this end, we present an accurate distribution mixture parameter estimation procedure which takes into account the diversity of the laws in the distribution mixture of a SPECT image. In our application, parameters of this distribution mixture are efficiently exploited in order to prevent overfitting of the noisy data for the iterative deconvolution techniques without regularization term, or to determine the exact support of the object to be restored when this one is needed. Recent blind deconvolution techniques such as the NAS\u2013RIF algorithm, [D. Kundur and D. Hatzinakos, \u2018\u2018Blind image restoration via recursive filtering using deterministic constraints,\u2019\u2019 in Proc. International Conf. On Acoustics, Speech, and Signal Processing, Vol. 4, pp. 547\u2013549 (1996).] combined with this estimation procedure, can be efficiently applied in SPECT imagery and yield promising results.<\/jats:p>","DOI":"10.1117\/1.1426082","type":"journal-article","created":{"date-parts":[[2002,7,26]],"date-time":"2002-07-26T10:00:39Z","timestamp":1027677639000},"page":"11-24","source":"Crossref","is-referenced-by-count":14,"title":["Comparison of deconvolution techniques using a distribution mixture parameter estimation: application in single photon emission computed tomography imagery"],"prefix":"10.1117","volume":"11","author":[{"given":"Max","family":"Mignotte","sequence":"first","affiliation":[{"name":"Univ. de Montreal"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean","family":"Meunier","sequence":"additional","affiliation":[{"name":"Univ. de Montreal"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Paul","family":"Soucy","sequence":"additional","affiliation":[{"name":"Ottawa Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Janicki","sequence":"additional","affiliation":[{"name":"Hopital Notre-Dame"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"189","reference":[{"key":"10.1117\/1.1426082_r1","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1109\/42.158937","volume":"11","author":"Boulfelfel","year":"1992","journal-title":"IEEE Trans. Med. Imaging","ISSN":"https:\/\/id.crossref.org\/issn\/0278-0062","issn-type":"print"},{"key":"10.1117\/1.1426082_r2","doi-asserted-by":"crossref","first-page":"2687","DOI":"10.1109\/TNS.1979.4330513","volume":"26","author":"Madsen","year":"1979","journal-title":"J. Nucl. Sci. Technol.","ISSN":"https:\/\/id.crossref.org\/issn\/0022-3131","issn-type":"print"},{"key":"10.1117\/1.1426082_r3","unstructured":"T. S. Curry, J. E. Dowdey, and R. C. Murry,\n                      Christensen\u2019s Physics of Diagnostic Radiology\n                      , Lea and Febiger (1990)."},{"key":"10.1117\/1.1426082_r4","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1118\/1.595735","volume":"12","author":"Webb","year":"1985","journal-title":"Med. Phys.","ISSN":"https:\/\/id.crossref.org\/issn\/0094-2405","issn-type":"print"},{"key":"10.1117\/1.1426082_r5","doi-asserted-by":"crossref","first-page":"914","DOI":"10.1109\/78.80914","volume":"39","author":"Katsaggelos","year":"1991","journal-title":"IEEE Trans. Acoust., Speech, Signal Process.","ISSN":"https:\/\/id.crossref.org\/issn\/0096-3518","issn-type":"print"},{"key":"10.1117\/1.1426082_r6","first-page":"118","volume":"52","author":"Molina","year":"1994","journal-title":"Restoration HST Images Spectra II"},{"key":"10.1117\/1.1426082_r7","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1364\/OL.13.000547","volume":"13","author":"Ayers","year":"1988","journal-title":"Opt. Lett.","ISSN":"https:\/\/id.crossref.org\/issn\/0146-9592","issn-type":"print"},{"key":"10.1117\/1.1426082_r8","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1109\/83.491316","volume":"5","author":"You","year":"1996","journal-title":"IEEE Trans. Image Process.","ISSN":"https:\/\/id.crossref.org\/issn\/1057-7149","issn-type":"print"},{"key":"10.1117\/1.1426082_r9","doi-asserted-by":"crossref","first-page":"615","DOI":"10.2307\/2372313","volume":"73","author":"Landweber","year":"1951","journal-title":"Am. J. Math.","ISSN":"https:\/\/id.crossref.org\/issn\/0002-9327","issn-type":"print"},{"key":"10.1117\/1.1426082_r10","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1086\/111605","volume":"79","author":"Lucy","year":"1974","journal-title":"Astron. J.","ISSN":"https:\/\/id.crossref.org\/issn\/0004-6256","issn-type":"print"},{"key":"10.1117\/1.1426082_r11","first-page":"196","volume":"52","author":"Hunt","year":"1992","journal-title":"Astronomical Data Analysis Software and Systems I"},{"key":"10.1117\/1.1426082_r12","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1007\/BF01391351","volume":"69","author":"Van Cittert","year":"1931","journal-title":"Z. Phys.","ISSN":"https:\/\/id.crossref.org\/issn\/0044-3328","issn-type":"print"},{"key":"10.1117\/1.1426082_r13","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1117\/12.325693","volume":"3461","author":"Biggs","year":"1998","journal-title":"Proc. SPIE","ISSN":"https:\/\/id.crossref.org\/issn\/0277-786X","issn-type":"print"},{"key":"10.1117\/1.1426082_r14","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1111\/j.2517-6161.1977.tb01600.x","volume":"39","author":"Dempster","year":"1976","journal-title":"J. B. R. Statistical Soc."},{"key":"10.1117\/1.1426082_r15","doi-asserted-by":"crossref","unstructured":"D. Kundur and D. Hatzinakos, \u201cBlind image restoration via recursive filtering using deterministic constraints,\u201d in\n                      Proc. International Conf. On Acoustics, Speech, and Signal Processing\n                      , Vol. 4, pp. 547\u2013549 (1996).","DOI":"10.1109\/ICASSP.1996.547737"},{"key":"10.1117\/1.1426082_r16","doi-asserted-by":"crossref","unstructured":"D. C. Costa and P. J. Ell,\n                      Brain Blood Flow in Neurology and Psychiatry\n                      , P. J. Ell, Series Ed. Churchill, Livingstone (1991).","DOI":"10.1097\/00006231-199207000-00017"},{"key":"10.1117\/1.1426082_r17","unstructured":"S. Banks,\n                      Signal Processing, Image Processing and Pattern Recognition\n                      , Prentice Hall, Englewood Cliffs, New Jersey (1990)."},{"key":"10.1117\/1.1426082_r18","doi-asserted-by":"crossref","unstructured":"F. Salzenstein and W. Pieczinsky, \u201cUnsupervised Bayesian segmentation using hidden markovian fields,\u201d in\n                      Proc. Int. Conf. On Acoustics, Speech, and Signal Processing\n                      , pp. 2411\u20132414 (May 1995).","DOI":"10.1109\/ICASSP.1995.479979"},{"key":"10.1117\/1.1426082_r19","first-page":"39","volume":"2","author":"Braathen","year":"1993","journal-title":"Graphics Vision"},{"key":"10.1117\/1.1426082_r20","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1109\/TPAMI.1984.4767596","volume":"6","author":"Geman","year":"1984","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell.","ISSN":"https:\/\/id.crossref.org\/issn\/0162-8828","issn-type":"print"},{"key":"10.1117\/1.1426082_r21","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1111\/j.2517-6161.1986.tb01412.x","volume":"B-48","author":"Besag","year":"1986","journal-title":"J. R. Statistical Soc."},{"key":"10.1117\/1.1426082_r22","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1002\/hbm.460030303","volume":"3","author":"Friston","year":"1995","journal-title":"Hum. Brain Mapping"},{"key":"10.1117\/1.1426082_r23","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1109\/10.821781","volume":"47","author":"Mignotte","year":"2000","journal-title":"IEEE Trans. Biomed. Eng.","ISSN":"https:\/\/id.crossref.org\/issn\/0018-9294","issn-type":"print"}],"container-title":["Journal of Electronic Imaging"],"original-title":[],"link":[{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-electronic-imaging\/volume-11\/issue-01\/11\/Comparison-of-deconvolution-techniques-using-a-distribution-mixture-parameter-estimation\/10.1117\/1.1426082.full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T21:29:33Z","timestamp":1790890173000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-electronic-imaging\/volume-11\/issue-01\/11\/Comparison-of-deconvolution-techniques-using-a-distribution-mixture-parameter-estimation\/10.1117\/1.1426082.full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2002,1,1]]},"references-count":23,"journal-issue":{"issue":"01"},"URL":"https:\/\/doi.org\/10.1117\/1.1426082","relation":{},"ISSN":["1017-9909","1560-229X"],"issn-type":[{"value":"1017-9909","type":"print"},{"value":"1560-229X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2002,1,1]]}}}