{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T21:58:56Z","timestamp":1790891936175,"version":"4.1.0"},"reference-count":34,"publisher":"SPIE-Intl Soc Optical Eng","issue":"01","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Electron. Imag."],"published-print":{"date-parts":[[2003,1,1]]},"abstract":"<jats:p>We present a new method for evaluating the performance of nonrigid image registration algorithms by analyzing the invertibility and transitivity properties of the transformations that they produce. The invertibility and transitivity of transformations computed using a unidirectional and a consistent linear-elastic registration algorithm are evaluated. The invertibility of the transformations is evaluated by comparing the composition of transformations from images A to B and B to A to the identity mapping. The transitivity of the transformations is evaluated by measuring the difference between the identity mapping and the composition of the transformations from images A to B, B to C, and C to A. Transformations are generated by matching three computer-generated phantoms, three computed tomography (CT) data of infant heads, and 23 magnetic resonance imaging (MRI) data of adult brains. In all cases, the inverse consistency constraint (ICC) algorithm out-performs the unidirectional algorithm by producing transformations that have less inverse consistency error and less transitivity error. For the MRI brain data, the ICC algorithm reduced the maximum inverse consistency error by 205 times, the average transitivity error by 50%, and the maximum transitivity error by 37% on average compared to the unidirectional algorithm.<\/jats:p>","DOI":"10.1117\/1.1526494","type":"journal-article","created":{"date-parts":[[2003,1,30]],"date-time":"2003-01-30T15:42:55Z","timestamp":1043941375000},"page":"106-117","source":"Crossref","is-referenced-by-count":44,"title":["Invertibility and transitivity analysis for nonrigid image registration"],"prefix":"10.1117","volume":"12","author":[{"given":"Gary E.","family":"Christensen","sequence":"first","affiliation":[{"name":"Univ. of Iowa"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hans J.","family":"Johnson","sequence":"additional","affiliation":[{"name":"Univ. of Iowa"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"189","reference":[{"key":"10.1117\/1.1526494_r1","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1109\/38.144829","volume":"12","author":"Ho\u0308hne","year":"1992","journal-title":"IEEE Comput. Graphics Appl.","ISSN":"https:\/\/id.crossref.org\/issn\/0272-1716","issn-type":"print"},{"key":"10.1117\/1.1526494_r2","doi-asserted-by":"crossref","first-page":"11944","DOI":"10.1073\/pnas.90.24.11944","volume":"90","author":"Miller","year":"1993","journal-title":"Proc. Natl. Acad. Sci. U.S.A.","ISSN":"https:\/\/id.crossref.org\/issn\/0027-8424","issn-type":"print"},{"key":"10.1117\/1.1526494_r3","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1006\/nimg.1995.1012","volume":"2","author":"Mazziotta","year":"1995","journal-title":"Neuroimage","ISSN":"https:\/\/id.crossref.org\/issn\/1053-8119","issn-type":"print"},{"key":"10.1117\/1.1526494_r4","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1177\/096228029700600305","volume":"6","author":"Miller","year":"1997","journal-title":"Stat. Methods Med. Res.","ISSN":"https:\/\/id.crossref.org\/issn\/0962-2802","issn-type":"print"},{"key":"10.1117\/1.1526494_r5","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1148\/radiology.202.2.9015081","volume":"202","author":"Haller","year":"1997","journal-title":"Radiology","ISSN":"https:\/\/id.crossref.org\/issn\/0033-8419","issn-type":"print"},{"key":"10.1117\/1.1526494_r6","doi-asserted-by":"crossref","first-page":"787","DOI":"10.1148\/radiology.199.3.8638006","volume":"199","author":"Haller","year":"1996","journal-title":"Radiology","ISSN":"https:\/\/id.crossref.org\/issn\/0033-8419","issn-type":"print"},{"key":"10.1117\/1.1526494_r7","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/S0360-3016(01)01667-4","volume":"51","author":"Christensen","year":"2001","journal-title":"Int. J. Radiat. Oncol., Biol., Phys.","ISSN":"https:\/\/id.crossref.org\/issn\/0360-3016","issn-type":"print"},{"key":"10.1117\/1.1526494_r8","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1097\/00004728-199307000-00004","volume":"17","author":"Woods","year":"1993","journal-title":"J. Comput. Assist. Tomogr.","ISSN":"https:\/\/id.crossref.org\/issn\/0363-8715","issn-type":"print"},{"key":"10.1117\/1.1526494_r9","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1097\/00004728-199801000-00027","volume":"22","author":"Woods","year":"1998","journal-title":"J. Comput. Assist. Tomogr.","ISSN":"https:\/\/id.crossref.org\/issn\/0363-8715","issn-type":"print"},{"key":"10.1117\/1.1526494_r10","doi-asserted-by":"crossref","unstructured":"S. C. Joshi, A. Banerjee, G. E. Christensen, J. G. Csernansky, J. W. Haller, M. I. Miller, and L. Wang, \u201cGaussian random fields on sub-manifolds for characterizing brain surfaces,\u201d in\n                      Information Processing in Medical Imaging\n                      , J. Duncan and G. Gindi, Eds., LNCS 1230, pp. 381\u2013386, Springer, Berlin (1997).","DOI":"10.1007\/3-540-63046-5_30"},{"key":"10.1117\/1.1526494_r11","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1117\/12.348613","volume":"3661","author":"Christensen","year":"1999","journal-title":"Proc. SPIE","ISSN":"https:\/\/id.crossref.org\/issn\/0277-786X","issn-type":"print"},{"key":"10.1117\/1.1526494_r12","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1097\/00004728-199707000-00007","volume":"21","author":"West","year":"1997","journal-title":"J. Comput. Assist. Tomogr.","ISSN":"https:\/\/id.crossref.org\/issn\/0363-8715","issn-type":"print"},{"key":"10.1117\/1.1526494_r13","doi-asserted-by":"crossref","first-page":"1012","DOI":"10.1097\/00004728-199611000-00030","volume":"20","author":"Freeborough","year":"1996","journal-title":"J. Comput. Assist. Tomogr.","ISSN":"https:\/\/id.crossref.org\/issn\/0363-8715","issn-type":"print"},{"key":"10.1117\/1.1526494_r14","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1097\/00004728-199801000-00028","volume":"22","author":"Woods","year":"1998","journal-title":"J. Comput. Assist. Tomogr.","ISSN":"https:\/\/id.crossref.org\/issn\/0363-8715","issn-type":"print"},{"key":"10.1117\/1.1526494_r15","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1016\/S1361-8415(98)80022-4","volume":"2","author":"Thirion","year":"1998","journal-title":"Med. Image Anal.","ISSN":"https:\/\/id.crossref.org\/issn\/1361-8415","issn-type":"print"},{"key":"10.1117\/1.1526494_r16","doi-asserted-by":"crossref","unstructured":"G. E. Christensen, \u201cConsistent linear-elastic transformations for image matching,\u201d in,\n                      Information Processing in Medical Imaging\n                      , A. Kuba and M. Samal, Eds., LCNS 1613, pp. 224\u2013237, Springer, Berlin (1999).","DOI":"10.1007\/3-540-48714-X_17"},{"key":"10.1117\/1.1526494_r17","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1109\/42.932742","volume":"20","author":"Christensen","year":"2001","journal-title":"IEEE Trans. Med. Imaging","ISSN":"https:\/\/id.crossref.org\/issn\/0278-0062","issn-type":"print"},{"key":"10.1117\/1.1526494_r18","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1109\/42.836369","volume":"19","author":"Holden","year":"2000","journal-title":"IEEE Trans. Med. Imaging","ISSN":"https:\/\/id.crossref.org\/issn\/0278-0062","issn-type":"print"},{"key":"10.1117\/1.1526494_r19","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/S1361-8415(97)85002-5","volume":"1","author":"Thompson","year":"1997","journal-title":"Med. Image Anal","ISSN":"https:\/\/id.crossref.org\/issn\/1361-8415","issn-type":"print"},{"key":"10.1117\/1.1526494_r20","doi-asserted-by":"crossref","first-page":"864","DOI":"10.1109\/42.650882","volume":"16","author":"Christensen","year":"1997","journal-title":"IEEE Trans. Med. Imaging","ISSN":"https:\/\/id.crossref.org\/issn\/0278-0062","issn-type":"print"},{"key":"10.1117\/1.1526494_r21","doi-asserted-by":"crossref","unstructured":"G. E. Christensen, \u201cBayesian framework for image registration using eigenfunctions,\u201d in\n                      Brain Warping\n                      , A. Toga, Ed., pp. 85\u2013100, Academic Press, San Diego, CA (1999).","DOI":"10.1016\/B978-012692535-7\/50081-1"},{"key":"10.1117\/1.1526494_r22","unstructured":"H. J. Johnson, \u201cMethod for consistent linear-elastic medical image registration,\u201d MS Thesis, Department of Electrical and Computer Engineering, University of Iowa, Iowa City (May 2000)."},{"key":"10.1117\/1.1526494_r23","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1109\/83.536892","volume":"5","author":"Christensen","year":"1996","journal-title":"IEEE Trans. Image Process.","ISSN":"https:\/\/id.crossref.org\/issn\/1057-7149","issn-type":"print"},{"key":"10.1117\/1.1526494_r24","doi-asserted-by":"crossref","unstructured":"J. Ashburner and K. J. Friston, \u201cSpatial normalization,\u201d in\n                      Brain Warping\n                      , A. Toga, Ed., pp. 27\u201344, Academic Press, San Diego, CA (1999).","DOI":"10.1016\/B978-012692535-7\/50078-1"},{"key":"10.1117\/1.1526494_r25","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1080\/01621459.1991.10475053","volume":"86","author":"Amit","year":"1991","journal-title":"J. Am. Stat. Assoc.","ISSN":"https:\/\/id.crossref.org\/issn\/0003-1291","issn-type":"print"},{"key":"10.1117\/1.1526494_r26","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1097\/00004728-199403000-00005","volume":"18","author":"Collins","year":"1994","journal-title":"J. Comput. Assist. Tomogr.","ISSN":"https:\/\/id.crossref.org\/issn\/0363-8715","issn-type":"print"},{"key":"10.1117\/1.1526494_r27","doi-asserted-by":"crossref","unstructured":"D. L. Collins, A. P. Zijdenbos, W. F. C. Baare, and A. C. Evans, \u201cAnimal+insect: improved cortical structure segmentation,\u201d in\n                      Information Processing in Medical Imaging\n                      , A. Kuba and M. Samal, Eds. LCNS 1613, pp. 210\u2013223, Springer, Berlin (1999).","DOI":"10.1007\/3-540-48714-X_16"},{"key":"10.1117\/1.1526494_r28","unstructured":"R. Bajcsy and S. Kovacic, \u201cMultiresolution elastic matching,\u201d Technical Report MS-CIS-87-94, GRASP Lab 123, Department of Computer and Information Science, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia (1987)."},{"key":"10.1117\/1.1526494_r29","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1117\/12.208686","volume":"2434","author":"Gee","year":"1995","journal-title":"Proc. SPIE","ISSN":"https:\/\/id.crossref.org\/issn\/0277-786X","issn-type":"print"},{"key":"10.1117\/1.1526494_r30","unstructured":"A. Toga, Ed.,\n                      Brain Warping\n                      , Academic Press, San Diego, CA (1999)."},{"key":"10.1117\/1.1526494_r31","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1109\/42.563664","volume":"16","author":"Maes","year":"1997","journal-title":"IEEE Trans. Med. Imaging","ISSN":"https:\/\/id.crossref.org\/issn\/0278-0062","issn-type":"print"},{"key":"10.1117\/1.1526494_r32","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/S1361-8415(01)80004-9","volume":"1","author":"Wells","year":"1996","journal-title":"Med. Image Anal","ISSN":"https:\/\/id.crossref.org\/issn\/1361-8415","issn-type":"print"},{"key":"10.1117\/1.1526494_r33","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1137\/0915014","volume":"15","author":"Amit","year":"1994","journal-title":"SIAM J. Sci. Comput. (USA)","ISSN":"https:\/\/id.crossref.org\/issn\/1064-8275","issn-type":"print"},{"key":"10.1117\/1.1526494_r34","doi-asserted-by":"crossref","unstructured":"G. E. Christensen, A. A. Kane, J. L. Marsh, and M. W. Vannier, \u201cSynthesis of an individualized cranial atlas with dysmorphic shape,\u201d\n                      IEEE Proc. Math. Meth. Biomed. Image Anal.\n                      , 309\u2013318 (June 1996).","DOI":"10.1109\/MMBIA.1996.534083"}],"container-title":["Journal of Electronic Imaging"],"original-title":[],"link":[{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-electronic-imaging\/volume-12\/issue-01\/106\/Invertibility-and-transitivity-analysis-for-nonrigid-image-registration\/10.1117\/1.1526494.full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T21:29:10Z","timestamp":1790890150000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-electronic-imaging\/volume-12\/issue-01\/106\/Invertibility-and-transitivity-analysis-for-nonrigid-image-registration\/10.1117\/1.1526494.full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003,1,1]]},"references-count":34,"journal-issue":{"issue":"01"},"URL":"https:\/\/doi.org\/10.1117\/1.1526494","relation":{},"ISSN":["1017-9909","1560-229X"],"issn-type":[{"value":"1017-9909","type":"print"},{"value":"1560-229X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2003,1,1]]}}}