{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T01:03:46Z","timestamp":1790816626871,"version":"4.1.0"},"reference-count":25,"publisher":"SPIE-Intl Soc Optical Eng","issue":"03","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Biomed. Opt."],"published-print":{"date-parts":[[2004,5,1]]},"abstract":"<jats:p>Fluorescence spectroscopy is a promising technology for detection of epithelial precancers and cancers. While age and menopausal status influence measurements in the cervix, other variables do not significantly affect the diagnosis. In this study we examine probe pressure as a variable. A fiber optic probe to measure fluorescence spectra at different calibrated levels of pressure was designed and tested. A pilot study was conducted measuring fluorescence excitation emission matrices in 20 patients at light, medium, and firm pressure. Spectroscopic data were pre-processed and analyzed to compare mean peak intensities as a function of pressure. Further statistical analyses tested for differences in intensities at each excitation\/emission wavelength pair. Four providers made measurements from 41 sites; 33 yielded good quality spectroscopic data (22 squamous normal, 7 squamous abnormal, 3 columnar normal, 1 transformation zone) from 17 of 20 patients. At all pressure levels, abnormal tissue showed less fluorescence intensity than normal tissue, and post-menopausal patients showed higher fluorescence intensity than premenopausal patients, consistent with previous analyses. A permutation analysis suggests that pressure does not significantly affect fluorescence intensity or lineshape. While other studies are needed to confirm these findings, this study suggests that fluorescence spectroscopy is a robust technology likely not influenced by fiber optic probe pressure.<\/jats:p>","DOI":"10.1117\/1.1695562","type":"journal-article","created":{"date-parts":[[2004,4,21]],"date-time":"2004-04-21T18:01:22Z","timestamp":1082570482000},"page":"523-533","source":"Crossref","is-referenced-by-count":42,"title":["Effect of probe pressure on cervical fluorescence spectroscopy measurements"],"prefix":"10.1117","volume":"9","author":[{"given":"Audrey","family":"Nath","sequence":"first","affiliation":[{"name":"Univ. of Texas M.D. Anderson Cancer Ctr."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kelley","family":"Rivoire","sequence":"additional","affiliation":[{"name":"Univ. of Texas M.D. Anderson Cancer Ctr."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sung K.","family":"Chang","sequence":"additional","affiliation":[{"name":"Univ. of Texas\/Austin"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dennis D.","family":"Cox","sequence":"additional","affiliation":[{"name":"Rice Univ."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edward N.","family":"Atkinson","sequence":"additional","affiliation":[{"name":"Univ. of Texas"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michelle","family":"Follen","sequence":"additional","affiliation":[{"name":"Univ. of Texas M.D. Anderson Cancer Ctr."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2347-9467","authenticated-orcid":false,"given":"Rebecca R.","family":"Richards-Kortum","sequence":"additional","affiliation":[{"name":"Univ. of Texas\/Austin"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"189","reference":[{"key":"10.1117\/1.1695562_r1","first-page":"350","volume":"16","author":"Bigio","year":"1995","journal-title":"Lasers Surg. Med.","ISSN":"https:\/\/id.crossref.org\/issn\/0196-8092","issn-type":"print"},{"key":"10.1117\/1.1695562_r2","doi-asserted-by":"crossref","first-page":"1806","DOI":"10.1109\/JQE.1987.1073234","volume":"23","author":"Alfano","year":"1987","journal-title":"IEEE J. Quantum Electron.","ISSN":"https:\/\/id.crossref.org\/issn\/0018-9197","issn-type":"print"},{"key":"10.1117\/1.1695562_r3","first-page":"682","volume":"62","author":"Georgakoudi","year":"2002","journal-title":"Cancer Res.","ISSN":"https:\/\/id.crossref.org\/issn\/0008-5472","issn-type":"print"},{"key":"10.1117\/1.1695562_r4","doi-asserted-by":"crossref","first-page":"10193","DOI":"10.1073\/pnas.91.21.10193","volume":"91","author":"Ramanujam","year":"1994","journal-title":"Proc. Natl. Acad. Sci. U.S.A.","ISSN":"https:\/\/id.crossref.org\/issn\/0027-8424","issn-type":"print"},{"key":"10.1117\/1.1695562_r5","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1002\/(SICI)1096-9101(1996)19:1<63::AID-LSM8>3.0.CO;2-O","volume":"19","author":"Ramanujam","year":"1996","journal-title":"Lasers Surg. Med.","ISSN":"https:\/\/id.crossref.org\/issn\/0196-8092","issn-type":"print"},{"key":"10.1117\/1.1695562_r6","doi-asserted-by":"crossref","first-page":"720","DOI":"10.1111\/j.1751-1097.1996.tb03130.x","volume":"64","author":"Ramaujam","year":"1996","journal-title":"Photochem. Photobiol.","ISSN":"https:\/\/id.crossref.org\/issn\/0031-8655","issn-type":"print"},{"key":"10.1117\/1.1695562_r7","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1002\/(SICI)1096-9101(1999)24:1<29::AID-LSM6>3.0.CO;2-H","volume":"24","author":"Brookner","year":"1999","journal-title":"Lasers Surg. Med.","ISSN":"https:\/\/id.crossref.org\/issn\/0196-8092","issn-type":"print"},{"key":"10.1117\/1.1695562_r8","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1117\/1.1578642","volume":"8","author":"Brookner","year":"2003","journal-title":"J. Biomed. Opt.","ISSN":"https:\/\/id.crossref.org\/issn\/1083-3668","issn-type":"print"},{"key":"10.1117\/1.1695562_r9","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1117\/1.1509753","volume":"7","author":"Chang","year":"2002","journal-title":"J. Biomed. Opt.","ISSN":"https:\/\/id.crossref.org\/issn\/1083-3668","issn-type":"print"},{"key":"10.1117\/1.1695562_r10","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1562\/0031-8655(2001)0730636AMOFCT2.0.CO2","volume":"73","author":"Drezek","year":"2001","journal-title":"Photochem. Photobiol.","ISSN":"https:\/\/id.crossref.org\/issn\/0031-8655","issn-type":"print"},{"key":"10.1117\/1.1695562_r11","first-page":"146","volume":"72","author":"Shim","year":"2000","journal-title":"Photochem. Photobiol.","ISSN":"https:\/\/id.crossref.org\/issn\/0031-8655","issn-type":"print"},{"key":"10.1117\/1.1695562_r12","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1562\/0031-8655(2000)072<0103:OEWFIV>2.0.CO;2","volume":"72","author":"Heintzelman","year":"2000","journal-title":"Photochem. Photobiol.","ISSN":"https:\/\/id.crossref.org\/issn\/0031-8655","issn-type":"print"},{"key":"10.1117\/1.1695562_r13","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1002\/(SICI)1096-9101(1999)25:3<237::AID-LSM8>3.0.CO;2-F","volume":"25","author":"Agarwal","year":"1999","journal-title":"Lasers Surg. Med.","ISSN":"https:\/\/id.crossref.org\/issn\/0196-8092","issn-type":"print"},{"key":"10.1117\/1.1695562_r14","unstructured":"J. L. Devore,\n                      Probability and Statistics for Engineering and the Sciences, Fifth Edition\n                      , Duxbury, Pacific Grove, California (1999)."},{"key":"10.1117\/1.1695562_r15","unstructured":"P. Westfall and S. Young,\n                      Resampling Basied Multiple Testing\n                      , John Wiley and Sons, New York (1993)."},{"key":"10.1117\/1.1695562_r16","doi-asserted-by":"crossref","first-page":"1633","DOI":"10.1093\/clinchem\/37.9.1633","volume":"37","author":"Zijlstra","year":"1991","journal-title":"Clin. Chem.","ISSN":"https:\/\/id.crossref.org\/issn\/0009-9147","issn-type":"print"},{"key":"10.1117\/1.1695562_r17","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1117\/1.1413209","volume":"6","author":"Drezek","year":"2001","journal-title":"J. Biomed. Opt.","ISSN":"https:\/\/id.crossref.org\/issn\/1083-3668","issn-type":"print"},{"key":"10.1117\/1.1695562_r18","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1002\/lsm.1900130609","volume":"13","author":"Mahadevan","year":"1993","journal-title":"Lasers Surg. Med.","ISSN":"https:\/\/id.crossref.org\/issn\/0196-8092","issn-type":"print"},{"key":"10.1117\/1.1695562_r19","first-page":"111","volume":"19","author":"Richards-Kortum","year":"1994","journal-title":"J. Cell. Biochem.","ISSN":"https:\/\/id.crossref.org\/issn\/0730-2312","issn-type":"print"},{"key":"10.1117\/1.1695562_r20","doi-asserted-by":"crossref","first-page":"730","DOI":"10.1562\/0031-8655(2000)071<0730:APISTC>2.0.CO;2","volume":"71","author":"Brookner","year":"2000","journal-title":"Photochem. Photobiol.","ISSN":"https:\/\/id.crossref.org\/issn\/0031-8655","issn-type":"print"},{"key":"10.1117\/1.1695562_r21","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1002\/lsm.1097","volume":"29","author":"Nordstrom","year":"2001","journal-title":"Lasers Surg. Med.","ISSN":"https:\/\/id.crossref.org\/issn\/0196-8092","issn-type":"print"},{"key":"10.1117\/1.1695562_r22","doi-asserted-by":"crossref","first-page":"947","DOI":"10.1111\/j.1471-0528.2002.01311.x","volume":"109","author":"Weingandt","year":"2002","journal-title":"British J. Obstet. Gynecol."},{"key":"10.1117\/1.1695562_r23","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1067\/mob.2002.121075","volume":"186","author":"Georgakoudi","year":"2002","journal-title":"Amer J. Obstet. Gynecol."},{"key":"10.1117\/1.1695562_r24","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1117\/1.1528207","volume":"8","author":"Utzinger","year":"2003","journal-title":"J. Biomed. Opt.","ISSN":"https:\/\/id.crossref.org\/issn\/1083-3668","issn-type":"print"},{"key":"10.1117\/1.1695562_r25","unstructured":"\u201cDraft guidance for industry: electro-optical sensors for the in vivo detection of cervical cancer and its precursors: submission guidance for an IDE\/PMA (8\/25\/1999),\u201d CDRH: 126\/Federal Register: Vol. 65, No. 50, p. 13776 (2000)."}],"container-title":["Journal of Biomedical Optics"],"original-title":[],"link":[{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-biomedical-optics\/volume-9\/issue-03\/523\/Effect-of-probe-pressure-on-cervical-fluorescence-spectroscopy-measurements\/10.1117\/1.1695562.full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:26:32Z","timestamp":1790814392000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-biomedical-optics\/volume-9\/issue-03\/523\/Effect-of-probe-pressure-on-cervical-fluorescence-spectroscopy-measurements\/10.1117\/1.1695562.full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,5,1]]},"references-count":25,"journal-issue":{"issue":"03"},"URL":"https:\/\/doi.org\/10.1117\/1.1695562","relation":{},"ISSN":["1083-3668","1560-2281"],"issn-type":[{"value":"1083-3668","type":"print"},{"value":"1560-2281","type":"electronic"}],"subject":[],"published":{"date-parts":[[2004,5,1]]}}}