{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T21:58:33Z","timestamp":1790891913344,"version":"4.1.0"},"reference-count":14,"publisher":"SPIE-Intl Soc Optical Eng","issue":"03","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Electron. Imag."],"published-print":{"date-parts":[[2007,7,1]]},"abstract":"<jats:p>Most digital cameras incorporate nonlinear mapping from the amount of light falling onto an imaging sensor to a picture's intensity. However, this nonlinear mapping would cause problems in some linear operations of image processing such as depth-from-defocus (DFD). We address the erroneous effects of the nonlinear response function of a digital still camera in DFD. A spatial-domain DFD technique called S-transform is employed to present the effects of the nonlinear mapping. To enhance DFD performance, we undistort the camera response function. Comparagrams of differently exposed multiple images are employed to estimate the response function. The estimated response function is then fitted to a piecewise linear function. To compare DFD performance, we use four different approaches of the S-transform for automatic focusing of the camera. Compensation of the nonlinear response function enhances AF performance of the camera and estimates blur parameters more accurately.<\/jats:p>","DOI":"10.1117\/1.2774830","type":"journal-article","created":{"date-parts":[[2007,10,1]],"date-time":"2007-10-01T18:02:47Z","timestamp":1191261767000},"page":"1-7","source":"Crossref","is-referenced-by-count":0,"title":["Effects of nonlinear camera response function in spatial domain depth-from-defocus"],"prefix":"10.1117","volume":"16","author":[{"given":"Soon-Yong","family":"Park","sequence":"first","affiliation":[{"name":"Kyungpook National Univ."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"189","reference":[{"key":"10.1117\/1.2774830_r1","first-page":"2","volume":"1","author":"Aggarwal","year":"2001","journal-title":"Int. Conf. on Comp. Vis."},{"key":"10.1117\/1.2774830_r2","doi-asserted-by":"publisher","DOI":"10.1117\/1.1580829"},{"key":"10.1117\/1.2774830_r3","doi-asserted-by":"crossref","unstructured":"P. Debevec and J. Malik , \u201cRecovering high dynamic range radiance maps from photographs,\u201d\n                      Proc. SIGGRAPH\n                      97 (1997).","DOI":"10.1145\/258734.258884"},{"key":"10.1117\/1.2774830_r4","first-page":"1","volume":"16","author":"Ghita","year":"2000","journal-title":"Vision"},{"key":"10.1117\/1.2774830_r5","doi-asserted-by":"crossref","unstructured":"M. Grossberg and S. Nayar , \u201cWhat is the space of camera response functions?\u201d\n                      Proc. IEEE Conf. Comp. Vis. Patt. Recogn.\n                      (2003).","DOI":"10.1109\/CVPR.2003.1211522"},{"key":"10.1117\/1.2774830_r6","doi-asserted-by":"crossref","unstructured":"S. Lin and L. Zhang , \u201cDetermining the radiometric response function from a single grayscale image,\u201d\n                      Proc. IEEE Conf. Comp. Vis. Patt. Recog.\n                      66\u201373 (2005).","DOI":"10.1109\/CVPR.2005.128"},{"key":"10.1117\/1.2774830_r7","doi-asserted-by":"crossref","DOI":"10.1364\/JOSAA.22.000839","volume":"22","author":"Litvinov","year":"2005","journal-title":"J. Opt. Soc. Am. A","ISSN":"https:\/\/id.crossref.org\/issn\/0740-3232","issn-type":"print"},{"key":"10.1117\/1.2774830_r8","doi-asserted-by":"crossref","unstructured":"C. Mander, C. Aimone, and S. Mann , \u201cCamera response function recovery from different illuminations of identical subject matter,\u201d\n                      Proc. IEEE Conf. Image Proc.\n                      pp. 2965\u20132968 (2004).","DOI":"10.1109\/ICIP.2004.1421735"},{"key":"10.1117\/1.2774830_r9","doi-asserted-by":"crossref","unstructured":"S. Mann and R. Mann , \u201cQuantigraphic imaging: estimating the camera response and exposure from differently exposed images,\u201d\n                      Int. Conf. Comp. Vis. Patt. Recog.\n                      , pp. 842\u2013849 (2001).","DOI":"10.1109\/CVPR.2001.990571"},{"key":"10.1117\/1.2774830_r10","doi-asserted-by":"publisher","DOI":"10.1109\/83.855434"},{"key":"10.1117\/1.2774830_r11","doi-asserted-by":"crossref","unstructured":"S. Nayar and T. Mitsunaga , \u201cHigh dynamic range imaging: spatially varying pixel exposures,\u201d\n                      Proc. IEEE Conf. Comp. Vis. Patt. Recog.\n                      , pp. 472\u2013479 (2000).","DOI":"10.1109\/CVPR.2000.855857"},{"key":"10.1117\/1.2774830_r12","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1109\/TPAMI.1987.4767940","volume":"9","author":"Pentland","year":"1987","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell.","ISSN":"https:\/\/id.crossref.org\/issn\/0162-8828","issn-type":"print"},{"key":"10.1117\/1.2774830_r13","doi-asserted-by":"publisher","DOI":"10.1007\/BF02028349"},{"key":"10.1117\/1.2774830_r14","volume":"2599","author":"Watanabe","year":"1995","journal-title":"Proc. SPIE","ISSN":"https:\/\/id.crossref.org\/issn\/0277-786X","issn-type":"print"}],"container-title":["Journal of Electronic Imaging"],"original-title":[],"link":[{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-electronic-imaging\/volume-16\/issue-03\/033021\/Effects-of-nonlinear-camera-response-function-in-spatial-domain-depth\/10.1117\/1.2774830.full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T21:31:31Z","timestamp":1790890291000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-electronic-imaging\/volume-16\/issue-03\/033021\/Effects-of-nonlinear-camera-response-function-in-spatial-domain-depth\/10.1117\/1.2774830.full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,7,1]]},"references-count":14,"journal-issue":{"issue":"03"},"URL":"https:\/\/doi.org\/10.1117\/1.2774830","relation":{},"ISSN":["1017-9909","1560-229X"],"issn-type":[{"value":"1017-9909","type":"print"},{"value":"1560-229X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,7,1]]}}}