{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T01:00:36Z","timestamp":1790298036381,"version":"4.1.0"},"reference-count":31,"publisher":"SPIE-Intl Soc Optical Eng","issue":"01","funder":[{"name":"Fundamental Research Funds for the Central Universities","award":["SWU117024"],"award-info":[{"award-number":["SWU117024"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Electron. Imag."],"published-print":{"date-parts":[[2019,1,7]]},"abstract":"<jats:p>We present a gaze estimation method for a head-mounted full-view egocentric camera that can capture egocentric video together with users\u2019 gaze cues. While the conventional gaze recording device has two cameras, an eye camera and a scene camera, the proposed gaze recording device has only a single spherical camera with a full field of view. To determine the point of gaze on full-view images, we present an eye-model-based gaze estimation method by means of three-dimensional iris projection. First, an eye model is built according to the precalibration process of an eyeball center and the eyeball biological parameters; then, we express the 3D iris contour in the eye model and project it back to the spherical camera model. Since 2D iris contours can be detected directly on images and can also be expressed under the spherical model, the relationship between the 3D iris contour and the 2D iris contour can be found. By solving this problem, the gaze direction under the camera model is determined; subsequently, the point of gaze on the images can be inferred. Since in the proposed method, a single spherical camera can play the role of the conventional two cameras, not only do the proposed method results have a simpler system structure but also the cumbersome operation of the calibration for the conventional two-camera gaze measurement devices becomes unnecessary. The effectiveness of the proposed method is shown by the experimental results.<\/jats:p>","DOI":"10.1117\/1.jei.28.1.013002","type":"journal-article","created":{"date-parts":[[2019,1,7]],"date-time":"2019-01-07T11:05:17Z","timestamp":1546859117000},"page":"1-8","source":"Crossref","is-referenced-by-count":3,"title":["Gaze estimation using a head-mounted single full-view camera"],"prefix":"10.1117","volume":"28","author":[{"given":"Jianfeng","family":"Li","sequence":"first","affiliation":[{"name":"School of Electronic and Information Engineering, Southwest Univ."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuhao","family":"Shan","sequence":"first","affiliation":[{"name":"Graduate School of Information Sciences, Hiroshima City Univ."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shigang","family":"Li","sequence":"additional","affiliation":[{"name":"School of Electronic and Information Engineering, Southwest Univ."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tong","family":"Chen","sequence":"additional","affiliation":[{"name":"School of Electronic and Information Engineering, Southwest Univ."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"189","reference":[{"key":"r1","doi-asserted-by":"publisher","DOI":"10.1109\/ICRA.2013.6631193"},{"key":"r2","article-title":"Schau genau!","author":"Wechselberger","year":"2015"},{"key":"r3","article-title":"Why eye tracking in shopper studies","year":"2017"},{"key":"r4","doi-asserted-by":"publisher","DOI":"10.1007\/s10803-009-0884-3"},{"key":"r5","doi-asserted-by":"publisher","DOI":"10.1007\/s10803-016-3002-3"},{"key":"r6","doi-asserted-by":"publisher","DOI":"10.1109\/IROS.2015.7353483"},{"key":"r7","doi-asserted-by":"crossref","DOI":"10.1051\/itmconf\/20171201019","article-title":"A review on fatigue driving detection","author":"Shi","year":"2017"},{"key":"r8","article-title":"Eye tracking for virtual and augmented reality","year":"2016"},{"key":"r9","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2005.863952"},{"key":"r10","doi-asserted-by":"publisher","DOI":"10.1109\/ICRA.2017.7989194"},{"key":"r11","doi-asserted-by":"publisher","DOI":"10.1109\/CVPRW.2014.93"},{"key":"r12","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2004.831523"},{"key":"r13","doi-asserted-by":"publisher","DOI":"10.1109\/ICCVW.2011.6130505"},{"key":"r14","doi-asserted-by":"publisher","DOI":"10.1109\/CVPR.2005.531"},{"key":"r15","doi-asserted-by":"publisher","DOI":"10.1109\/THMS.2015.2477507"},{"key":"r16","doi-asserted-by":"publisher","DOI":"10.1109\/CVPR.2015.7299081"},{"key":"r17","first-page":"197","article-title":"3D gaze estimation from 2D pupil positions on monocular head-mounted eye trackers","author":"Mansouryar","year":"2016"},{"key":"r18","doi-asserted-by":"publisher","DOI":"10.1109\/ICIP.2016.7532937"},{"key":"r19","doi-asserted-by":"publisher","DOI":"10.1109\/ICCV.2017.114"},{"key":"r20","doi-asserted-by":"publisher","DOI":"10.1109\/ICCV.2017.341"},{"key":"r21","first-page":"2176","article-title":"Eye tracking for everyone","author":"Krafka","year":"2016"},{"key":"r22","article-title":"Ricoh theta S","year":"2017"},{"key":"r23","doi-asserted-by":"publisher","DOI":"10.1109\/IROS.2006.282372"},{"key":"r24","doi-asserted-by":"publisher","DOI":"10.1109\/IROS.2008.4650703"},{"key":"r25","article-title":"OCamCalib toolbox download page","author":"Scaramuzza"},{"key":"r26","article-title":"OCamCalib: Omnidirectional camera calibration toolbox for Matlab","author":"Scaramuzza","year":"2013"},{"key":"r27","article-title":"Euler angles","year":"2018"},{"key":"r28","article-title":"Ceres solver","author":"Agarwal","year":"2016"},{"key":"r29","first-page":"125","article-title":"Accurate eye centre localisation by means of gradients","author":"Timm","year":"2011"},{"key":"r30","doi-asserted-by":"publisher","DOI":"10.1109\/CVPR.2014.229"},{"key":"r31","doi-asserted-by":"publisher","DOI":"10.1109\/ICIP.2015.7350892"}],"container-title":["Journal of Electronic Imaging"],"original-title":[],"link":[{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-electronic-imaging\/volume-28\/issue-01\/013002\/Gaze-estimation-using-a-head-mounted-single-full-view-camera\/10.1117\/1.JEI.28.1.013002.full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T00:18:20Z","timestamp":1790295500000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-electronic-imaging\/volume-28\/issue-01\/013002\/Gaze-estimation-using-a-head-mounted-single-full-view-camera\/10.1117\/1.JEI.28.1.013002.full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,1,7]]},"references-count":31,"journal-issue":{"issue":"01"},"URL":"https:\/\/doi.org\/10.1117\/1.jei.28.1.013002","relation":{},"ISSN":["1017-9909","1560-229X"],"issn-type":[{"value":"1017-9909","type":"print"},{"value":"1560-229X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,1,7]]}}}