{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T01:55:53Z","timestamp":1790819753821,"version":"4.1.0"},"reference-count":30,"publisher":"SPIE-Intl Soc Optical Eng","issue":"10","funder":[{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["CBET-1055379"],"award-info":[{"award-number":["CBET-1055379"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]},{"name":"NSF","award":["CBET-1055379"],"award-info":[{"award-number":["CBET-1055379"]}]},{"name":"National Institutes of Health","award":["1R01EY019951"],"award-info":[{"award-number":["1R01EY019951"]}],"id":[{"id":"https:\/\/ror.org\/01cwqze88","id-type":"ROR","asserted-by":"publisher"}]},{"name":"NIH","award":["1R01EY019951"],"award-info":[{"award-number":["1R01EY019951"]}]},{"name":"National Institutes of Health","award":["1R01EY019951"],"award-info":[{"award-number":["1R01EY019951"]}]},{"name":"Northwestern University Clinical and Translational Sciences Institute","award":["1R01EY019951"],"award-info":[{"award-number":["1R01EY019951"]}]},{"DOI":"10.13039\/100000002","name":"US National Institutes of Health","doi-asserted-by":"publisher","award":["1R01EY019951"],"award-info":[{"award-number":["1R01EY019951"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["CBET-1066776"],"award-info":[{"award-number":["CBET-1066776"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]},{"name":"NSF","award":["CBET-1066776"],"award-info":[{"award-number":["CBET-1066776"]}]},{"name":"National Institutes of Health","award":["1R24EY022883"],"award-info":[{"award-number":["1R24EY022883"]}],"id":[{"id":"https:\/\/ror.org\/01cwqze88","id-type":"ROR","asserted-by":"publisher"}]},{"name":"NIH","award":["1R24EY022883"],"award-info":[{"award-number":["1R24EY022883"]}]},{"name":"National Institutes of Health","award":["1R24EY022883"],"award-info":[{"award-number":["1R24EY022883"]}]},{"DOI":"10.13039\/100000002","name":"US National Institutes of Health","doi-asserted-by":"publisher","award":["1R24EY022883"],"award-info":[{"award-number":["1R24EY022883"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"name":"National Institutes of Health","award":["2R01EY019484"],"award-info":[{"award-number":["2R01EY019484"]}],"id":[{"id":"https:\/\/ror.org\/01cwqze88","id-type":"ROR","asserted-by":"publisher"}]},{"name":"NIH","award":["2R01EY019484"],"award-info":[{"award-number":["2R01EY019484"]}]},{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["BDI-1353952"],"award-info":[{"award-number":["BDI-1353952"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Biomed. Opt."],"published-print":{"date-parts":[[2015,10,23]]},"abstract":"<jats:p>Rodent models are indispensable in studying various retinal diseases. Noninvasive, high-resolution retinal imaging of rodent models is highly desired for longitudinally investigating the pathogenesis and therapeutic strategies. However, due to severe aberrations, the retinal image quality in rodents can be much worse than that in humans. We numerically and experimentally investigated the influence of chromatic aberration and optical illumination bandwidth on retinal imaging. We confirmed that the rat retinal image quality decreased with increasing illumination bandwidth. We achieved the retinal image resolution of 10\u2009\u2009\u03bcm using a 19\u00a0nm illumination bandwidth centered at 580\u00a0nm in a home-built fundus camera. Furthermore, we observed higher chromatic aberration in albino rat eyes than in pigmented rat eyes. This study provides a design guide for high-resolution fundus camera for rodents. Our method is also beneficial to dispersion compensation in multiwavelength retinal imaging applications.<\/jats:p>","DOI":"10.1117\/1.jbo.20.10.106010","type":"journal-article","created":{"date-parts":[[2015,10,26]],"date-time":"2015-10-26T13:05:18Z","timestamp":1445864718000},"page":"1-6","source":"Crossref","is-referenced-by-count":7,"title":["Investigating the influence of chromatic aberration and optical illumination bandwidth on fundus imaging in rats"],"prefix":"10.1117","volume":"20","author":[{"given":"Hao","family":"Li","sequence":"first","affiliation":[{"name":"Northwestern Univ."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenzhong","family":"Liu","sequence":"additional","affiliation":[{"name":"Northwestern Univ."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5089-1196","authenticated-orcid":false,"given":"Hao   F.","family":"Zhang","sequence":"additional","affiliation":[{"name":"Northwestern Univ."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"189","reference":[{"key":"r1","doi-asserted-by":"publisher","DOI":"10.1038\/nature02426"},{"key":"r2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pbio.1000112"},{"key":"r3","doi-asserted-by":"publisher","DOI":"10.1038\/nm1001-1086"},{"key":"r4","doi-asserted-by":"publisher","DOI":"10.1126\/science.1172447"},{"key":"r5","doi-asserted-by":"publisher","DOI":"10.1177\/0300985809359598"},{"key":"r6","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4614-3209-8_84"},{"key":"r7","doi-asserted-by":"publisher","DOI":"10.1155\/2012\/692609"},{"key":"r8","doi-asserted-by":"publisher","DOI":"10.1016\/0014-4835(75)90080-9"},{"key":"r9","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.2.003094"},{"key":"r10","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.06-0815"},{"key":"r11","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2005.09.037"},{"key":"r12","doi-asserted-by":"publisher","DOI":"10.1364\/OE.18.003967"},{"key":"r13","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.3.001811"},{"key":"r14","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.2.000717"},{"key":"r15","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.09-3675"},{"key":"r16","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.5.000547"},{"key":"r17","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.3.000715"},{"key":"r18","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(83)90146-3"},{"key":"r19","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(79)90143-3"},{"key":"r20","doi-asserted-by":"publisher","DOI":"10.1364\/JOSA.47.0564_1"},{"key":"r21","doi-asserted-by":"publisher","DOI":"10.1364\/OE.22.001193"},{"key":"r22","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.05-0272"},{"key":"r23","first-page":"152","article-title":"A review of methods for human retinal oximetry","author":"Harris","year":"2003"},{"key":"r24","article-title":"Retinal Diagnosis Instruments"},{"key":"r25","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.5.003059"},{"key":"r26","doi-asserted-by":"publisher","DOI":"10.1038\/srep06525"},{"key":"r27","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.3.000792"},{"key":"r28","doi-asserted-by":"publisher","DOI":"10.1097\/00061198-199400330-00003"},{"key":"r29","article-title":"Auto Fundus Camera ORION"},{"key":"r30","doi-asserted-by":"publisher","DOI":"10.1016\/S0166-4328(02)00126-2"}],"container-title":["Journal of Biomedical Optics"],"original-title":[],"link":[{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-biomedical-optics\/volume-20\/issue-10\/106010\/Investigating-the-influence-of-chromatic-aberration-and-optical-illumination-bandwidth\/10.1117\/1.JBO.20.10.106010.full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T01:03:43Z","timestamp":1790816623000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-biomedical-optics\/volume-20\/issue-10\/106010\/Investigating-the-influence-of-chromatic-aberration-and-optical-illumination-bandwidth\/10.1117\/1.JBO.20.10.106010.full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,10,23]]},"references-count":30,"journal-issue":{"issue":"10"},"URL":"https:\/\/doi.org\/10.1117\/1.jbo.20.10.106010","relation":{},"ISSN":["1083-3668","1560-2281"],"issn-type":[{"value":"1083-3668","type":"print"},{"value":"1560-2281","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,10,23]]}}}