{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T01:55:47Z","timestamp":1790819747654,"version":"4.1.0"},"reference-count":31,"publisher":"SPIE-Intl Soc Optical Eng","issue":"12","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Biomed. Opt."],"published-print":{"date-parts":[[2015,9,11]]},"abstract":"<jats:p>A hyperspectral image projector (HIP) based on liquid crystal on silicon spatial light modulators is explained and demonstrated to generate data cubes. The HIP-constructed data cubes are three-dimensional images of the spatial distribution of spectrally resolved abundances of intracellular light-absorbing oxyhemoglobin molecules in single erythrocytes. Spectrally and spatially resolved image data indistinguishable from the real scene may be used as standard data cubes, so-called digital phantoms, to calibrate image sensors and validate image analysis algorithms for their measurement quality, performance consistency, and interlaboratory comparisons for quantitative biomedical imaging applications.<\/jats:p>","DOI":"10.1117\/1.jbo.20.12.121309","type":"journal-article","created":{"date-parts":[[2015,10,21]],"date-time":"2015-10-21T12:30:40Z","timestamp":1445430640000},"page":"1-8","source":"Crossref","is-referenced-by-count":6,"title":["Digital phantoms generated by spectral and spatial light modulators"],"prefix":"10.1117","volume":"20","author":[{"given":"Bonghwan","family":"Chon","sequence":"first","affiliation":[{"name":"National Institute of Standards and Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fuyuki","family":"Tokumasu","sequence":"additional","affiliation":[{"name":"National Institutes of Health"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ji Youn","family":"Lee","sequence":"additional","affiliation":[{"name":"National Institute of Standards and Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David W.","family":"Allen","sequence":"additional","affiliation":[{"name":"National Institute of Standards and Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph P.","family":"Rice","sequence":"additional","affiliation":[{"name":"National Institute of Standards and Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9801-8529","authenticated-orcid":false,"given":"Jeeseong","family":"Hwang","sequence":"additional","affiliation":[{"name":"National Institute of Standards and Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"189","reference":[{"key":"r1","doi-asserted-by":"publisher","DOI":"10.1016\/j.meatsci.2014.09.001"},{"key":"r2","doi-asserted-by":"publisher","DOI":"10.1039\/c0an00042f"},{"key":"r3","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-006-9121-9"},{"key":"r4","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4614-4989-8_18"},{"key":"r5","doi-asserted-by":"publisher","DOI":"10.1117\/1.JBO.19.10.106004"},{"key":"r6","doi-asserted-by":"publisher","DOI":"10.2337\/dc08-2246"},{"key":"r7","doi-asserted-by":"publisher","DOI":"10.1021\/ac011275f"},{"key":"r8","doi-asserted-by":"publisher","DOI":"10.1109\/JSTQE.2011.2164239"},{"key":"r9","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.3.001433"},{"key":"r10","doi-asserted-by":"publisher","DOI":"10.1117\/1.1794706"},{"key":"r11","doi-asserted-by":"publisher","DOI":"10.7498\/aps.61.089501"},{"key":"r12","doi-asserted-by":"publisher","DOI":"10.1016\/j.optlaseng.2011.01.024"},{"key":"r13","doi-asserted-by":"publisher","DOI":"10.1038\/lsa.2014.94"},{"key":"r14","doi-asserted-by":"publisher","DOI":"10.1364\/OE.22.020663"},{"key":"r15","first-page":"142","article-title":"Dynamical system for recording and optical reconstruction of digital holograms","author":"Wernicke","year":"2006"},{"key":"r16","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.1.001408"},{"key":"r17","doi-asserted-by":"publisher","DOI":"10.1242\/jcs.01662"},{"key":"r18","first-page":"15552","article-title":"The state of ferriprotoporphyrin-IX in malaria pigment","author":"Fitch","year":"1987"},{"key":"r19","doi-asserted-by":"publisher","DOI":"10.1038\/35005132"},{"key":"r20","doi-asserted-by":"publisher","DOI":"10.1007\/s00436-006-0313-x"},{"key":"r21","doi-asserted-by":"publisher","DOI":"10.1016\/S0014-5793(03)00975-X"},{"key":"r22","doi-asserted-by":"publisher","DOI":"10.1016\/j.exppara.2010.05.006"},{"key":"r23","doi-asserted-by":"publisher","DOI":"10.1117\/12.543794"},{"key":"r24","doi-asserted-by":"publisher","DOI":"10.1117\/12.543798"},{"key":"r25","doi-asserted-by":"publisher","DOI":"10.1016\/0304-4165(93)90109-L"},{"key":"r26","doi-asserted-by":"publisher","DOI":"10.1088\/2040-8978\/14\/6\/065302"},{"key":"r27","doi-asserted-by":"publisher","DOI":"10.1016\/j.molbiopara.2009.03.007"},{"key":"r28","doi-asserted-by":"publisher","DOI":"10.1117\/12.849765"},{"key":"r29","doi-asserted-by":"publisher","DOI":"10.1364\/OE.17.014367"},{"key":"r30","article-title":"Optical properties spectra of Oxy-Hb solution","author":"Prahl","year":"2015"},{"key":"r31","first-page":"117","article-title":"Hyperspectral imaging system modeling","author":"Kerkes","year":"2003"}],"updated-by":[{"DOI":"10.1117\/1.jbo.20.12.129801","type":"retraction","label":"Retraction","source":"retraction-watch","updated":{"date-parts":[[2015,10,30]],"date-time":"2015-10-30T00:00:00Z","timestamp":1446163200000},"record-id":"4661"}],"container-title":["Journal of Biomedical Optics"],"original-title":[],"link":[{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-biomedical-optics\/volume-20\/issue-12\/121309\/Digital-phantoms-generated-by-spectral-and-spatial-light-modulators\/10.1117\/1.JBO.20.12.121309.full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T01:03:04Z","timestamp":1790816584000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-biomedical-optics\/volume-20\/issue-12\/121309\/Digital-phantoms-generated-by-spectral-and-spatial-light-modulators\/10.1117\/1.JBO.20.12.121309.full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,9,11]]},"references-count":31,"journal-issue":{"issue":"12"},"URL":"https:\/\/doi.org\/10.1117\/1.jbo.20.12.121309","relation":{},"ISSN":["1083-3668","1560-2281"],"issn-type":[{"value":"1083-3668","type":"print"},{"value":"1560-2281","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,9,11]]}}}