{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T01:56:00Z","timestamp":1790819760535,"version":"4.1.0"},"reference-count":17,"publisher":"SPIE-Intl Soc Optical Eng","issue":"12","license":[{"start":{"date-parts":[[2016,10,12]],"date-time":"2016-10-12T00:00:00Z","timestamp":1476230400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["1338133"],"award-info":[{"award-number":["1338133"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]},{"name":"NSF National Nanotechnology Coordinated Infrastructure Program","award":["1542210"],"award-info":[{"award-number":["1542210"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Biomed. Opt."],"published-print":{"date-parts":[[2016,10,12]]},"abstract":"<jats:p>Active optics such as deformable mirrors can be used to control both focal depth and aberrations during scanning laser microscopy. If the focal depth can be changed dynamically during scanning, then imaging of oblique surfaces becomes possible. If aberrations can be corrected dynamically during scanning, an image can be optimized throughout the field of view. Here, we characterize the speed and dynamic precision of a Boston Micromachines Corporation Multi-DM 140 element aberration correction mirror and a Revibro Optics 4-zone focus control mirror to assess suitability for use in an active and adaptive two-photon microscope. Tests for the multi-DM include both step response and sinusoidal frequency sweeps of specific Zernike modes (defocus, spherical aberration, coma, astigmatism, and trefoil). We find wavefront error settling times for mode amplitude steps as large as 400\u00a0nm to be less than 52\u2009\u2009\u03bcs, with 3\u00a0dB frequencies ranging from 6.5 to 10\u00a0kHz. The Revibro Optics mirror was tested for step response only, with wavefront error settling time less than 80\u2009\u2009\u03bcs for defocus steps up to 3000\u00a0nm, and less than 45\u2009\u2009\u03bcs for spherical aberration steps up to 600\u00a0nm. These response speeds are sufficient for intrascan correction at scan rates typical of two-photon microscopy.<\/jats:p>","DOI":"10.1117\/1.jbo.21.12.121507","type":"journal-article","created":{"date-parts":[[2016,10,12]],"date-time":"2016-10-12T06:31:22Z","timestamp":1476253882000},"page":"1-10","source":"Crossref","is-referenced-by-count":17,"title":["Dynamic performance of microelectromechanical systems deformable mirrors for use in an active\/adaptive two-photon microscope"],"prefix":"10.1117","volume":"21","author":[{"given":"Christian   C.","family":"Archer-Zhang","sequence":"first","affiliation":[{"name":"Montana State Univ."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Warren B.","family":"Foster","sequence":"additional","affiliation":[{"name":"Montana State Univ."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryan D.","family":"Downey","sequence":"additional","affiliation":[{"name":"Montana State Univ."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher L.","family":"Arrasmith","sequence":"additional","affiliation":[{"name":"Revibro Optics"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David L.","family":"Dickensheets","sequence":"additional","affiliation":[{"name":"Montana State Univ."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"189","reference":[{"key":"r1","doi-asserted-by":"publisher","DOI":"10.1038\/4569"},{"key":"r2","doi-asserted-by":"publisher","DOI":"10.1364\/OE.17.013354"},{"key":"r3","doi-asserted-by":"publisher","DOI":"10.1117\/1.3646209"},{"key":"r4","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.082544799"},{"key":"r5","doi-asserted-by":"publisher","DOI":"10.1364\/OE.11.001123"},{"key":"r6","doi-asserted-by":"publisher","DOI":"10.1063\/1.2804014"},{"key":"r7","doi-asserted-by":"publisher","DOI":"10.1364\/OE.14.010565"},{"key":"r8","doi-asserted-by":"publisher","DOI":"10.1364\/OL.34.002495"},{"key":"r9","doi-asserted-by":"publisher","DOI":"10.1117\/12.705045"},{"key":"r10","doi-asserted-by":"publisher","DOI":"10.1038\/nmeth.1411"},{"key":"r11","doi-asserted-by":"publisher","DOI":"10.1364\/OE.22.023786"},{"key":"r12","doi-asserted-by":"publisher","DOI":"10.1109\/JMEMS.2013.2251320"},{"key":"r13","doi-asserted-by":"publisher","DOI":"10.1117\/1.3574129"},{"key":"r14","doi-asserted-by":"publisher","DOI":"10.1117\/12.2042249"},{"key":"r15","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.1119590109"},{"key":"r16","article-title":"Laser scanning microscope system","author":"Saito","year":"2013"},{"key":"r17","doi-asserted-by":"publisher","DOI":"10.1117\/1.2911024"}],"container-title":["Journal of Biomedical Optics"],"original-title":[],"link":[{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-biomedical-optics\/volume-21\/issue-12\/121507\/Dynamic-performance-of-microelectromechanical-systems-deformable-mirrors-for-use-in\/10.1117\/1.JBO.21.12.121507.full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T01:04:06Z","timestamp":1790816646000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-biomedical-optics\/volume-21\/issue-12\/121507\/Dynamic-performance-of-microelectromechanical-systems-deformable-mirrors-for-use-in\/10.1117\/1.JBO.21.12.121507.full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,10,12]]},"references-count":17,"journal-issue":{"issue":"12"},"URL":"https:\/\/doi.org\/10.1117\/1.jbo.21.12.121507","relation":{},"ISSN":["1083-3668","1560-2281"],"issn-type":[{"value":"1083-3668","type":"print"},{"value":"1560-2281","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,10,12]]}}}