{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T01:55:33Z","timestamp":1790819733633,"version":"4.1.0"},"reference-count":34,"publisher":"SPIE-Intl Soc Optical Eng","issue":"07","funder":[{"name":"National Natural Science Foundation of China","award":["61275214"],"award-info":[{"award-number":["61275214"]}],"id":[{"id":"https:\/\/ror.org\/01h0zpd94","id-type":"ROR","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"Natural Science Foundation of China","doi-asserted-by":"publisher","award":["61275214"],"award-info":[{"award-number":["61275214"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"National Natural Science Foundation of China","award":["31170956"],"award-info":[{"award-number":["31170956"]}],"id":[{"id":"https:\/\/ror.org\/01h0zpd94","id-type":"ROR","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"Natural Science Foundation of China","doi-asserted-by":"publisher","award":["31170956"],"award-info":[{"award-number":["31170956"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"Natural Science Foundation of China","doi-asserted-by":"publisher","award":["61501100"],"award-info":[{"award-number":["61501100"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81301208"],"award-info":[{"award-number":["81301208"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Hebei Provincial Natural Science Foundation of China","award":["A2015501002"],"award-info":[{"award-number":["A2015501002"]}]},{"name":"Hebei Provincial Natural Science Foundation of China","award":["H2015501133"],"award-info":[{"award-number":["H2015501133"]}]},{"name":"Fundamental Research Funds","award":["N120223001"],"award-info":[{"award-number":["N120223001"]}]},{"name":"Central Universities","award":["N120223001"],"award-info":[{"award-number":["N120223001"]}]},{"name":"Research Fund for Higher School Science Technology","award":["QN20132014"],"award-info":[{"award-number":["QN20132014"]}]},{"name":"Science and Technology Research and Development","award":["JCYJ20120618142137681"],"award-info":[{"award-number":["JCYJ20120618142137681"]}]},{"name":"Colleges and Universities Scientific Research","award":["Z2015207"],"award-info":[{"award-number":["Z2015207"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Biomed. Opt."],"published-print":{"date-parts":[[2016,7,29]]},"abstract":"<jats:p>A blockage of the middle cerebral artery (MCA) on the cortical branch will seriously affect the blood supply of the cerebral cortex. Real-time monitoring of MCA hemodynamic parameters is critical for therapy and rehabilitation. Optical coherence tomography (OCT) is a powerful imaging modality that can produce not only structural images but also functional information on the tissue. We use OCT to detect hemodynamic changes after MCA branch occlusion. We injected a selected dose of endothelin-1 (ET-1) at a depth of 1\u00a0mm near the MCA and let the blood vessels follow a process first of occlusion and then of slow reperfusion as realistically as possible to simulate local cerebral ischemia. During this period, we used optical microangiography and Doppler OCT to obtain multiple hemodynamic MCA parameters. The change trend of these parameters from before to after ET-1 injection clearly reflects the dynamic regularity of the MCA. These results show the mechanism of the cerebral ischemia-reperfusion process after a transient middle cerebral artery occlusion and confirm that OCT can be used to monitor hemodynamic parameters.<\/jats:p>","DOI":"10.1117\/1.jbo.21.7.075014","type":"journal-article","created":{"date-parts":[[2016,7,29]],"date-time":"2016-07-29T03:31:27Z","timestamp":1469763087000},"page":"1-8","source":"Crossref","is-referenced-by-count":10,"title":["Hemodynamic changes in a rat parietal cortex after endothelin-1-induced middle cerebral artery occlusion monitored by optical coherence tomography"],"prefix":"10.1117","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5904-6415","authenticated-orcid":false,"given":"Jian","family":"Liu","sequence":"first","affiliation":[{"name":"Northeastern Univ."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yushu","family":"Ma","sequence":"additional","affiliation":[{"name":"Northeastern Univ."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shidan","family":"Dou","sequence":"additional","affiliation":[{"name":"Northeastern Univ."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi","family":"Wang","sequence":"additional","affiliation":[{"name":"Northeastern Univ."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dongsheng","family":"La","sequence":"additional","affiliation":[{"name":"Northeastern Univ."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianghong","family":"Liu","sequence":"additional","affiliation":[{"name":"Capital Medical Univ."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4079-9550","authenticated-orcid":false,"given":"Zhenhe","family":"Ma","sequence":"additional","affiliation":[{"name":"Northeastern Univ."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"189","reference":[{"key":"r1","first-page":"57","article-title":"Middle cerebral artery","author":"Roth","year":"2011"},{"key":"r2","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.19.7.870"},{"key":"r3","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.2.000579"},{"key":"r4","doi-asserted-by":"publisher","DOI":"10.1117\/1.NPh.2.2.025006"},{"key":"r5","doi-asserted-by":"publisher","DOI":"10.1038\/332411a0"},{"key":"r6","doi-asserted-by":"publisher","DOI":"10.1097\/00001756-199707280-00040"},{"key":"r7","doi-asserted-by":"publisher","DOI":"10.1006\/exnr.2000.7506"},{"key":"r8","doi-asserted-by":"publisher","DOI":"10.1038\/255332a0"},{"key":"r9","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-510X(03)00102-3"},{"key":"r10","doi-asserted-by":"publisher","DOI":"10.1038\/jcbfm.1993.108"},{"key":"r11","doi-asserted-by":"publisher","DOI":"10.1097\/00001756-199707280-00040"},{"key":"r12","doi-asserted-by":"publisher","DOI":"10.1007\/BF02259134"},{"key":"r13","doi-asserted-by":"publisher","DOI":"10.3109\/10641969509087080"},{"key":"r14","doi-asserted-by":"publisher","DOI":"10.1038\/jcbfm.1993.34"},{"key":"r15","doi-asserted-by":"publisher","DOI":"10.1016\/j.jneumeth.2009.01.009"},{"key":"r16","doi-asserted-by":"publisher","DOI":"10.1016\/0022-4073(88)90122-7"},{"key":"r17","doi-asserted-by":"publisher","DOI":"10.1117\/12.700967"},{"key":"r18","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.3.000455"},{"key":"r19","doi-asserted-by":"publisher","DOI":"10.1186\/s12938-015-0104-7"},{"key":"r20","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.v63:6"},{"key":"r21","article-title":"Doppler ultrasound method and apparatus for monitoring blood flow and hemodynamics","author":"Moehring","year":"2006"},{"key":"r22","doi-asserted-by":"publisher","DOI":"10.1080\/1931308X.2013.794618"},{"key":"r23","author":"Zhang","year":"2005"},{"key":"r24","doi-asserted-by":"publisher","DOI":"10.1126\/science.1957169"},{"key":"r25","doi-asserted-by":"publisher","DOI":"10.1364\/OL.22.001119"},{"key":"r26","doi-asserted-by":"publisher","DOI":"10.1364\/OPEX.13.007449"},{"key":"r27","doi-asserted-by":"publisher","DOI":"10.1364\/OE.11.003116"},{"key":"r28","doi-asserted-by":"publisher","DOI":"10.1364\/OE.15.004083"},{"key":"r29","doi-asserted-by":"publisher","DOI":"10.1117\/1.3625238"},{"key":"r30","doi-asserted-by":"publisher","DOI":"10.1002\/ar.v292:3"},{"key":"r31","doi-asserted-by":"publisher","DOI":"10.1113\/expphysiol.2009.047936"},{"key":"r32","doi-asserted-by":"publisher","DOI":"10.1038\/jcbfm.1993.108"},{"key":"r33","doi-asserted-by":"publisher","DOI":"10.1016\/j.jneumeth.2009.01.009"},{"key":"r34","doi-asserted-by":"publisher","DOI":"10.1007\/s10016-005-4616-7"}],"container-title":["Journal of Biomedical Optics"],"original-title":[],"link":[{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-biomedical-optics\/volume-21\/issue-07\/075014\/Hemodynamic-changes-in-a-rat-parietal-cortex-after-endothelin-1\/10.1117\/1.JBO.21.7.075014.full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T01:01:51Z","timestamp":1790816511000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-biomedical-optics\/volume-21\/issue-07\/075014\/Hemodynamic-changes-in-a-rat-parietal-cortex-after-endothelin-1\/10.1117\/1.JBO.21.7.075014.full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,7,29]]},"references-count":34,"journal-issue":{"issue":"07"},"URL":"https:\/\/doi.org\/10.1117\/1.jbo.21.7.075014","relation":{},"ISSN":["1083-3668","1560-2281"],"issn-type":[{"value":"1083-3668","type":"print"},{"value":"1560-2281","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,7,29]]}}}