{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T01:04:18Z","timestamp":1790298258412,"version":"4.1.0"},"reference-count":50,"publisher":"SPIE-Intl Soc Optical Eng","issue":"03","funder":[{"DOI":"10.13039\/501100003970","name":"Isfahan University of Medical Sciences","doi-asserted-by":"publisher","award":["395645"],"award-info":[{"award-number":["395645"]}],"id":[{"id":"10.13039\/501100003970","id-type":"DOI","asserted-by":"publisher"},{"id":"https:\/\/ror.org\/04waqzz56","id-type":"ROR","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Biomed. Opt."],"published-print":{"date-parts":[[2018,3,21]]},"abstract":"<jats:p>The present research intends to propose a fully automatic algorithm for the classification of three-dimensional (3-D) optical coherence tomography (OCT) scans of patients suffering from abnormal macula from normal candidates. The method proposed does not require any denoising, segmentation, retinal alignment processes to assess the intraretinal layers, as well as abnormalities or lesion structures. To classify abnormal cases from the control group, a two-stage scheme was utilized, which consists of automatic subsystems for adaptive feature learning and diagnostic scoring. In the first stage, a wavelet-based convolutional neural network (CNN) model was introduced and exploited to generate B-scan representative CNN codes in the spatial-frequency domain, and the cumulative features of 3-D volumes were extracted. In the second stage, the presence of abnormalities in 3-D OCTs was scored over the extracted features. Two different retinal SD-OCT datasets are used for evaluation of the algorithm based on the unbiased fivefold cross-validation (CV) approach. The first set constitutes 3-D OCT images of 30 normal subjects and 30 diabetic macular edema (DME) patients captured from the Topcon device. The second publicly available set consists of 45 subjects with a distribution of 15 patients in age-related macular degeneration, DME, and normal classes from the Heidelberg device. With the application of the algorithm on overall OCT volumes and 10 repetitions of the fivefold CV, the proposed scheme obtained an average precision of 99.33% on dataset1 as a two-class classification problem and 98.67% on dataset2 as a three-class classification task.<\/jats:p>","DOI":"10.1117\/1.jbo.23.3.035005","type":"journal-article","created":{"date-parts":[[2018,3,21]],"date-time":"2018-03-21T02:34:28Z","timestamp":1521599668000},"page":"1-10","source":"Crossref","is-referenced-by-count":39,"title":["Automatic diagnosis of abnormal macula in retinal optical coherence tomography images using wavelet-based convolutional neural network features and random forests classifier"],"prefix":"10.1117","volume":"23","author":[{"given":"Reza","family":"Rasti","sequence":"first","affiliation":[{"name":"Isfahan Univ. of Medical Sciences"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alireza","family":"Mehridehnavi","sequence":"additional","affiliation":[{"name":"Isfahan Univ. of Medical Sciences"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hossein","family":"Rabbani","sequence":"additional","affiliation":[{"name":"Isfahan Univ. of Medical Sciences"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fedra","family":"Hajizadeh","sequence":"additional","affiliation":[{"name":"Noor Eye Hospital and Clinics"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"189","reference":[{"key":"r1","doi-asserted-by":"publisher","DOI":"10.1038\/nbt892"},{"key":"r2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.291.15.1900"},{"key":"r3","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2007.11.019"},{"key":"r4","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2014-305702"},{"key":"r5","doi-asserted-by":"publisher","DOI":"10.1155\/2013\/417491"},{"key":"r6","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2016.2519439"},{"key":"r7","doi-asserted-by":"publisher","DOI":"10.1117\/1.3268773"},{"key":"r8","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.09-3790"},{"key":"r9","doi-asserted-by":"publisher","DOI":"10.1364\/OE.18.021293"},{"key":"r10","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2013.05.006"},{"key":"r11","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2017.04.007"},{"key":"r12","first-page":"666","article-title":"Automatic segmentation of nine layer boundaries in OCT images using convolutional neural networks and graph search","author":"Fang","year":"2017"},{"key":"r13","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.8.002732"},{"key":"r14","first-page":"862","article-title":"Multi-layer 3D simultaneous retinal OCT layer segmentation: just-enough interaction for routine clinical use","author":"Lee","year":"2018"},{"key":"r15","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2005.848655"},{"key":"r16","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.3.001127"},{"key":"r17","first-page":"166","article-title":"Three-dimensional segmentation of retinal cysts from spectral-domain optical coherence tomography images by the use of three-dimensional curvelet based K-SVD","author":"Esmaeili","year":"2016"},{"key":"r18","doi-asserted-by":"publisher","DOI":"10.1155\/2017\/4362603"},{"key":"r19","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2017.2734058"},{"key":"r20","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/58\/9\/2925"},{"key":"r21","doi-asserted-by":"publisher","DOI":"10.1117\/1.JBO.22.1.016012"},{"key":"r22","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2011.06.005"},{"key":"r23","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.5.003568"},{"key":"r24","doi-asserted-by":"publisher","DOI":"10.1117\/12.2081521"},{"key":"r25","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.7.004928"},{"key":"r26","doi-asserted-by":"publisher","DOI":"10.1364\/JOSAA.33.000455"},{"key":"r27","doi-asserted-by":"publisher","DOI":"10.1364\/BOE.8.000579"},{"key":"r28","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2017.2780115"},{"key":"r29","doi-asserted-by":"publisher","DOI":"10.1109\/TIP.2007.901238"},{"key":"r30","doi-asserted-by":"publisher","DOI":"10.1109\/BMEiCON.2014.7017441"},{"key":"r31","doi-asserted-by":"publisher","DOI":"10.1186\/1475-925X-12-117"},{"key":"r32","doi-asserted-by":"publisher","DOI":"10.1109\/TPAMI.2013.50"},{"key":"r33","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2010.2095026"},{"key":"r34","article-title":"RetiNet: automatic AMD identification in OCT volumetric data","author":"Apostolopoulos","year":"2016"},{"key":"r35","doi-asserted-by":"publisher","DOI":"10.1109\/5.726791"},{"key":"r36","doi-asserted-by":"publisher","DOI":"10.1016\/S0893-6080(03)00115-1"},{"key":"r37","doi-asserted-by":"publisher","DOI":"10.1364\/AO.29.004790"},{"key":"r38","doi-asserted-by":"publisher","DOI":"10.1016\/j.patcog.2017.08.004"},{"key":"r39","first-page":"1","article-title":"A CAD system for identification and classification of breast cancer tumors in DCE-MR images based on hierarchical convolutional neural networks","author":"Rasti","year":"2015"},{"key":"r40","first-page":"448","article-title":"Batch normalization: accelerating deep network training by reducing internal covariate shift","author":"Ioffe","year":"2015"},{"key":"r41","article-title":"Improving neural networks with dropout","author":"Srivastava","year":"2013"},{"key":"r42","doi-asserted-by":"publisher","DOI":"10.1109\/ICMLA.2016.0046"},{"key":"r43","author":"Chui","year":"2016"},{"key":"r44","doi-asserted-by":"publisher","DOI":"10.1109\/TGRS.2014.2335751"},{"key":"r45","author":"Chong","year":"2013"},{"key":"r46","article-title":"Adam: a method for stochastic optimization","author":"Kingma","year":"2014"},{"key":"r47","author":"Soille","year":"2013"},{"key":"r48","doi-asserted-by":"publisher","DOI":"10.1023\/A:1010933404324"},{"key":"r49","article-title":"Theano: a python framework for fast computation of mathematical expressions","author":"Team","year":"2016"},{"key":"r50","article-title":"Keras","author":"Chollet","year":"2015"}],"container-title":["Journal of Biomedical Optics"],"original-title":[],"link":[{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-biomedical-optics\/volume-23\/issue-03\/035005\/Automatic-diagnosis-of-abnormal-macula-in-retinal-optical-coherence-tomography\/10.1117\/1.JBO.23.3.035005.full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T00:57:22Z","timestamp":1790297842000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-biomedical-optics\/volume-23\/issue-03\/035005\/Automatic-diagnosis-of-abnormal-macula-in-retinal-optical-coherence-tomography\/10.1117\/1.JBO.23.3.035005.full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,3,21]]},"references-count":50,"journal-issue":{"issue":"03"},"URL":"https:\/\/doi.org\/10.1117\/1.jbo.23.3.035005","relation":{},"ISSN":["1083-3668","1560-2281"],"issn-type":[{"value":"1083-3668","type":"print"},{"value":"1560-2281","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,3,21]]}}}