{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T00:58:41Z","timestamp":1790297921157,"version":"4.1.0"},"reference-count":52,"publisher":"SPIE-Intl Soc Optical Eng","issue":"05","license":[{"start":{"date-parts":[[2019,5,23]],"date-time":"2019-05-23T00:00:00Z","timestamp":1558569600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Biomed. Opt."],"published-print":{"date-parts":[[2019,5,23]]},"abstract":"<jats:p>Correction of hyperopia requires an increase of the refractive power by steepening of the corneal surface. Present refractive surgical techniques based on corneal ablation (LASIK) or intrastromal lenticule extraction (SMILE) are problematic due to epithelial regrowth. Recently, it was shown that correction of low hyperopia can be achieved by implanting intracorneal inlays or allogeneic lenticules. We demonstrate a steepening of the anterior corneal surface after injection of a transparent, liquid filler material into a laser-dissected intrastromal pocket. We performed the study on ex-vivo porcine eyes. The increase of the refractive power was evaluated by optical coherence tomography (OCT). For a circular pocket, injection of 1\u2009\u03bcl filler material increased the refractive power by +4.5 diopters. An astigmatism correction is possible when ellipsoidal intrastromal pockets are created. Injection of 2\u2009\u03bcl filler material into an ellipsoidal pocket increased the refractive power by +10.9\u2009\u2009dpt on the short and +5.1\u2009\u2009dpt on the long axis. OCT will enable to monitor the refractive change during filler injection and is thus a promising technique for real-time dosimetry.<\/jats:p>","DOI":"10.1117\/1.jbo.24.5.058001","type":"journal-article","created":{"date-parts":[[2019,5,23]],"date-time":"2019-05-23T12:03:02Z","timestamp":1558612982000},"page":"1-7","source":"Crossref","is-referenced-by-count":7,"title":["Correction of hyperopia by intrastromal cutting and liquid filler injection"],"prefix":"10.1117","volume":"24","author":[{"given":"Sebastian","family":"Freidank","sequence":"first","affiliation":[{"name":"Univ. zu L\u00fcbeck"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alfred","family":"Vogel","sequence":"additional","affiliation":[{"name":"Univ. zu L\u00fcbeck"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard R.","family":"Anderson","sequence":"additional","affiliation":[{"name":"Wellman Ctr. for Photomedicine"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6881-1895","authenticated-orcid":false,"given":"Reginald","family":"Birngruber","sequence":"additional","affiliation":[{"name":"Univ. zu L\u00fcbeck"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Norbert","family":"Linz","sequence":"additional","affiliation":[{"name":"Univ. zu L\u00fcbeck"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"189","reference":[{"key":"r1","doi-asserted-by":"publisher","DOI":"10.31053\/1853.0605.v74.n2.15529"},{"key":"r2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(14)73013-2"},{"key":"r3","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(81)34957-4"},{"key":"r4","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19890901-04"},{"key":"r5","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(00)00329-1"},{"key":"r6","doi-asserted-by":"publisher","DOI":"10.1002\/14651858.CD007112.pub3"},{"key":"r7","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20070401-06"},{"key":"r8","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.11.031"},{"key":"r9","doi-asserted-by":"publisher","DOI":"10.1097\/00055735-199908000-00005"},{"key":"r10","first-page":"S517","article-title":"LASIK for high myopia: one year experience","author":"Marinho","year":"1996"},{"key":"r11","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2016.03.028"},{"key":"r12","doi-asserted-by":"publisher","DOI":"10.1097\/00004397-196606010-00004"},{"key":"r13","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19970701-09"},{"key":"r14","first-page":"107","article-title":"Refractive keratoplasty with intrastromal hydrogel lenticular implants","author":"McCarey","year":"1981"},{"key":"r15","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1996.01100130129002"},{"key":"r16","first-page":"197","article-title":"Nutritional aspects of corneal grafts and prostheses","author":"Maurice","year":"1969"},{"key":"r17","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820030212"},{"key":"r18","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2009.05.019"},{"key":"r19","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0b013e328362293e"},{"key":"r20","doi-asserted-by":"publisher","DOI":"10.1097\/ICL.0000000000000128"},{"key":"r21","doi-asserted-by":"publisher","DOI":"10.1097\/ICL.0000000000000381"},{"key":"r22","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.122.10.1441"},{"key":"r23","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20131021-07"},{"key":"r24","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000000276"},{"key":"r25","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.11-8070"},{"key":"r26","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0194209"},{"key":"r27","doi-asserted-by":"publisher","DOI":"10.1080\/14764170701774901"},{"key":"r28","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(88)80063-4"},{"key":"r29","doi-asserted-by":"publisher","DOI":"10.1109\/2944.796309"},{"key":"r30","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2008.08.026"},{"key":"r31","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20121116-01"},{"key":"r32","article-title":"Method for laser machining transparent materials","author":"Vogel","year":"2013"},{"key":"r33","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.13-12580"},{"key":"r34","doi-asserted-by":"publisher","DOI":"10.1007\/s00347-013-2994-8"},{"key":"r35","doi-asserted-by":"publisher","DOI":"10.1117\/2.1201511.006157"},{"key":"r36","doi-asserted-by":"publisher","DOI":"10.1007\/s00347-013-2993-9"},{"key":"r37","doi-asserted-by":"publisher","DOI":"10.1117\/1.JBO.20.9.095005"},{"key":"r38","first-page":"382","article-title":"Appendices II and IV","author":"Gullstrand","year":"1909"},{"key":"r39","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-19940301-11"},{"key":"r40","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-198403000-00009"},{"key":"r41","doi-asserted-by":"publisher","DOI":"10.4103\/0974-9233.61217"},{"key":"r42","doi-asserted-by":"publisher","DOI":"10.1586\/eop.11.56"},{"key":"r43","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S57056"},{"key":"r44","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20150820-02"},{"key":"r45","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2015-306822"},{"key":"r46","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.70.2.152"},{"key":"r47","article-title":"Device for laser cutting within transparent materials","author":"Vogel","year":"2015"},{"key":"r48","doi-asserted-by":"publisher","DOI":"10.1016\/j.msec.2015.07.053"},{"key":"r49","doi-asserted-by":"publisher","DOI":"10.1016\/j.jconrel.2017.10.031"},{"key":"r50","doi-asserted-by":"publisher","DOI":"10.1016\/j.asj.2008.03.004"},{"key":"r51","doi-asserted-by":"publisher","DOI":"10.1055\/s-0035-1544924"},{"key":"r52","doi-asserted-by":"publisher","DOI":"10.1097\/DSS.0000000000000334"}],"container-title":["Journal of Biomedical Optics"],"original-title":[],"link":[{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-biomedical-optics\/volume-24\/issue-05\/058001\/Correction-of-hyperopia-by-intrastromal-cutting-and-liquid-filler-injection\/10.1117\/1.JBO.24.5.058001.full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T23:59:33Z","timestamp":1790294373000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-biomedical-optics\/volume-24\/issue-05\/058001\/Correction-of-hyperopia-by-intrastromal-cutting-and-liquid-filler-injection\/10.1117\/1.JBO.24.5.058001.full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5,23]]},"references-count":52,"journal-issue":{"issue":"05"},"URL":"https:\/\/doi.org\/10.1117\/1.jbo.24.5.058001","relation":{},"ISSN":["1083-3668","1560-2281"],"issn-type":[{"value":"1083-3668","type":"print"},{"value":"1560-2281","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,5,23]]}}}