{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,13]],"date-time":"2026-11-13T04:38:25Z","timestamp":1794544705500,"version":"4.9.1"},"reference-count":0,"publisher":"SPIE-Intl Soc Optical Eng","issue":"12","license":[{"start":{"date-parts":[[2025,12,12]],"date-time":"2025-12-12T00:00:00Z","timestamp":1765497600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"National Institutes of Health","award":["P30EY07551"],"award-info":[{"award-number":["P30EY07551"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Biomed. Opt."],"published-print":{"date-parts":[[2025,12,12]]},"abstract":"<jats:p>SignificanceEstimating biomechanical properties of the in vivo crystalline lens remains a challenge and is a barrier to evaluating novel lens softening therapies. There is a need to estimate quantitative biomechanical properties of the human anterior and mid segments of the eye in vivo for conditions such as presbyopia.AimWe aim to develop a multimodal elastography device that enables high-performance sequential 3D imaging with both Brillouin microscopy and optical coherence elastography (OCE).ApproachWe combined Brillouin spectroscopy and OCE on a modified slit lamp platform for human measurements. The multimodal system was first characterized and then tested on both a porcine eye and a human subject.ResultsBoth OCE and Brillouin microscopy were characterized at peak operating performance for clinical imaging. Successful measurements of an in situ porcine lens and a human in vivo lens are reported.ConclusionWe demonstrated the first successful multimodal OCE and Brillouin microscopy measurement in a human subject. This instrument offers the potential to characterize the biomechanical status of presbyopia with age.<\/jats:p>","DOI":"10.1117\/1.jbo.30.12.124511","type":"journal-article","created":{"date-parts":[[2025,12,12]],"date-time":"2025-12-12T18:46:02Z","timestamp":1765565162000},"page":"1-10","source":"Crossref","is-referenced-by-count":3,"title":["Clinical multimodal Brillouin microscopy-optical coherence elastography system for lens biomechanics"],"prefix":"10.1117","volume":"30","author":[{"given":"Justin","family":"Schumacher","sequence":"first","affiliation":[{"name":"University of Maryland College Park"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7078-3782","authenticated-orcid":false,"given":"Christian","family":"Zevallos-Delgado","sequence":"additional","affiliation":[{"name":"University of Houston"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leana","family":"Rohman","sequence":"additional","affiliation":[{"name":"University of Miami"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander W.","family":"Schill","sequence":"additional","affiliation":[{"name":"University of Houston"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8396-5451","authenticated-orcid":false,"given":"Manmohan","family":"Singh","sequence":"additional","affiliation":[{"name":"University of Houston"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hongyuan","family":"Zhang","sequence":"additional","affiliation":[{"name":"Cole Eye Institute"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Ruggeri","sequence":"additional","affiliation":[{"name":"University of Miami"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Marie","family":"Parel","sequence":"additional","affiliation":[{"name":"University of Miami"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabrice","family":"Manns","sequence":"additional","affiliation":[{"name":"University of Miami"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5532-5027","authenticated-orcid":false,"given":"Kirill V.","family":"Larin","sequence":"additional","affiliation":[{"name":"University of Houston"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giuliano","family":"Scarcelli","sequence":"additional","affiliation":[{"name":"University of Maryland College Park"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"189","container-title":["Journal of Biomedical Optics"],"original-title":[],"link":[{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-biomedical-optics\/volume-30\/issue-12\/124511\/Clinical-multimodal-Brillouin-microscopy-optical-coherence-elastography-system-for-lens\/10.1117\/1.JBO.30.12.124511.full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T20:28:00Z","timestamp":1790195280000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-biomedical-optics\/volume-30\/issue-12\/124511\/Clinical-multimodal-Brillouin-microscopy-optical-coherence-elastography-system-for-lens\/10.1117\/1.JBO.30.12.124511.full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,12]]},"references-count":0,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2025,12,1]]}},"URL":"https:\/\/doi.org\/10.1117\/1.jbo.30.12.124511","relation":{},"ISSN":["1083-3668","1560-2281"],"issn-type":[{"value":"1083-3668","type":"print"},{"value":"1560-2281","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,12]]}}}