{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T00:04:03Z","timestamp":1790208243778,"version":"4.1.0"},"reference-count":47,"publisher":"SPIE-Intl Soc Optical Eng","issue":"S1","license":[{"start":{"date-parts":[[2024,12,26]],"date-time":"2024-12-26T00:00:00Z","timestamp":1735171200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J. Med. Imag."],"published-print":{"date-parts":[[2024,12,26]]},"abstract":"<jats:p>PurposeHigh soft-tissue contrast imaging is essential for effective radiotherapy treatment. This could potentially be realized using both megavoltage and kilovoltage x-ray sources available on some therapy treatment systems to perform \u201cMV-kV\u201d dual-energy (DE) computed tomography (CT). However, noisy megavoltage images obtained with existing energy-integrating detectors (EIDs) are a limiting factor for clinical translation. We explore the potential for non-spectral photon-counting detectors (PCDs) to improve MV-kV image quality simply by equally weighting all MV photons rather than up-weighting the less informative, lower contrast high-energy photons as in an EID.ApproachThree computational methods were applied to compare non-spectral PCDs with EIDs in MV-kV DE imaging. A single-line integral estimation theory approach was used to calculate the basis material signal-to-noise ratio (SNR) of tissue (1 to 50\u00a0cm) and bone (0.1 to 10\u00a0cm). CT images of a tissue cylinder with seven bone inserts (densities 1.0 to 2.2 g\/cm3) were simulated to assess material decomposition accuracy. Multiple noisy simulations of an anthropomorphic phantom were performed to generate pixel-by-pixel noise profiles.ResultsPCDs yielded a 15% to 45% improvement in single-line integral SNR for both materials. In CT simulations, similar material decomposition accuracy was achieved, with both EIDs and PCDs slightly underestimating bone density. However, PCDs yield a higher contrast-to-noise ratio and more uniform noise texture than EIDs in virtual monoenergetic images.ConclusionsWe demonstrate the potential for improved MV-kV DE CT imaging using non-spectral PCDs and quantify the degree of improvement in a range of object compositions. This work motivates the experimental assessment of PCDs for megavoltage imaging and the potential clinical translation of PCDs to radiotherapy imaging.<\/jats:p>","DOI":"10.1117\/1.jmi.11.s1.s12811","type":"journal-article","created":{"date-parts":[[2024,12,26]],"date-time":"2024-12-26T07:05:42Z","timestamp":1735196742000},"page":"1-15","source":"Crossref","is-referenced-by-count":0,"title":["Utility of photon-counting detectors for MV-kV dual-energy computed tomography imaging"],"prefix":"10.1117","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4894-2895","authenticated-orcid":false,"given":"Giavanna","family":"Jadick","sequence":"first","affiliation":[{"name":"The University of Chicago"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-3075-0859","authenticated-orcid":false,"given":"Maya","family":"Ventura","sequence":"additional","affiliation":[{"name":"The University of Chicago Medical Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick J.","family":"La Rivi\u00e8re","sequence":"additional","affiliation":[{"name":"The University of Chicago"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"189","reference":[{"key":"r1","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.11.2.023501"},{"key":"r2","doi-asserted-by":"publisher","DOI":"10.1117\/12.2653674"},{"key":"r3","doi-asserted-by":"publisher","DOI":"10.1117\/12.3006854"},{"key":"r4","doi-asserted-by":"publisher","DOI":"10.1002\/acm2.13468"},{"key":"r5","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2016.02.026"},{"key":"r6","doi-asserted-by":"publisher","DOI":"10.1016\/j.adro.2019.07.013"},{"key":"r7","doi-asserted-by":"publisher","DOI":"10.1016\/0010-4825(76)90069-X"},{"key":"r8","doi-asserted-by":"publisher","DOI":"10.1118\/1.1445414"},{"key":"r9","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/44\/10\/316"},{"key":"r10","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/61\/17\/6297"},{"key":"r11","doi-asserted-by":"publisher","DOI":"10.1118\/1.4927786"},{"key":"r12","doi-asserted-by":"publisher","DOI":"10.1186\/s13244-020-00899-y"},{"key":"r13","doi-asserted-by":"publisher","DOI":"10.1118\/1.2222075"},{"key":"r14","doi-asserted-by":"publisher","DOI":"10.1118\/1.1477234"},{"key":"r15","doi-asserted-by":"publisher","DOI":"10.1002\/mp.13355"},{"key":"r16","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ace09a"},{"key":"r17","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/56\/6\/001"},{"key":"r18","doi-asserted-by":"publisher","DOI":"10.1118\/1.1990289"},{"key":"r19","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v15i6.4897"},{"key":"r20","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2007.11.048"},{"key":"r21","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2015.03.007"},{"key":"r22","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2020.10.030"},{"key":"r23","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-023-09545-9"},{"key":"r24","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/abc5a5"},{"key":"r25","doi-asserted-by":"publisher","DOI":"10.1118\/1.3592932"},{"key":"r26","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/61\/16\/6132"},{"key":"r27","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.8.6.063501"},{"key":"r28","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.212579"},{"key":"r29","doi-asserted-by":"publisher","DOI":"10.1117\/1.JMI.9.1.013501"},{"key":"r30","doi-asserted-by":"publisher","DOI":"10.1109\/NSSMIC.2008.4774098"},{"key":"r31","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/61\/18\/6733"},{"key":"r32","doi-asserted-by":"publisher","DOI":"10.1109\/NSS\/MIC44867.2021.9875680"},{"key":"r33","doi-asserted-by":"publisher","DOI":"10.1118\/1.1639148"},{"key":"r34","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/51\/13\/R24"},{"key":"r35","doi-asserted-by":"publisher","DOI":"10.13140\/RG.2.1.1680.3289"},{"key":"r36","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/54\/5\/014"},{"key":"r37","doi-asserted-by":"publisher","DOI":"10.1016\/j.bspc.2018.01.010"},{"key":"r38","doi-asserted-by":"publisher","DOI":"10.1109\/NSSMIC.2001.1008660"},{"key":"r39","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.12.8580"},{"key":"r40","doi-asserted-by":"publisher","DOI":"10.1118\/1.3609097"},{"key":"r41","doi-asserted-by":"publisher","DOI":"10.1118\/1.4722751"},{"key":"r42","doi-asserted-by":"publisher","DOI":"10.1118\/1.3480985"},{"key":"r43","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aabe21"},{"key":"r44","doi-asserted-by":"publisher","DOI":"10.1109\/TRPMS.2020.3007380"},{"key":"r45","doi-asserted-by":"publisher","DOI":"10.1016\/S1053-4296(99)80058-7"},{"key":"r46","doi-asserted-by":"publisher","DOI":"10.1117\/12.840052"},{"key":"r47","doi-asserted-by":"publisher","DOI":"10.1118\/1.4866890"}],"container-title":["Journal of Medical Imaging"],"original-title":[],"link":[{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-medical-imaging\/volume-11\/issue-S1\/S12811\/Utility-of-photon-counting-detectors-for-MV-kV-dual-energy\/10.1117\/1.JMI.11.S1.S12811.full","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T23:32:04Z","timestamp":1790206324000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.spiedigitallibrary.org\/journals\/journal-of-medical-imaging\/volume-11\/issue-S1\/S12811\/Utility-of-photon-counting-detectors-for-MV-kV-dual-energy\/10.1117\/1.JMI.11.S1.S12811.full"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,26]]},"references-count":47,"journal-issue":{"issue":"S1","published-online":{"date-parts":[[2024,12,1]]}},"URL":"https:\/\/doi.org\/10.1117\/1.jmi.11.s1.s12811","relation":{},"ISSN":["2329-4302","2329-4310"],"issn-type":[{"value":"2329-4302","type":"print"},{"value":"2329-4310","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,26]]}}}