{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T14:04:50Z","timestamp":1790949890748,"version":"4.1.0"},"reference-count":25,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2001,6,12]],"date-time":"2001-06-12T00:00:00Z","timestamp":992304000000},"content-version":"vor","delay-in-days":11,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medical Physics"],"published-print":{"date-parts":[[2001,6]]},"abstract":"<jats:p>If metallic material is exposed to ionizing radiation of sufficient high energy, an increase in dose due to backscatter radiation occurs in front of this material. Our purpose in this study was to quantify these doses at variable distances between scattering materials and the detector at axial beam angles between <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6664-math-0001.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6664:mp6664-math-0001\"\/> (zero angle in beams eye view) and <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6664-math-0002.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6664:mp6664-math-0002\"\/> Copper, silver and lead sheets embedded in a phantom of perspex were exposed to 10 MV\u2010bremsstrahlung. The detector we developed is based on the fluorescence property of pyromellitic acid (1,2,4,5 benzenetetracarboxylic acid) after exposure to ionizing radiation. Our results show that the additional doses and the corresponding dose distribution in front of the scattering materials depend quantitatively and qualitatively on the beam angle. The backscatter dose increases with varying beam angle from <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6664-math-0003.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6664:mp6664-math-0003\"\/> to <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6664-math-0004.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6664:mp6664-math-0004\"\/> up to a maximum at <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6664-math-0005.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6664:mp6664-math-0005\"\/> for copper and silver. At angles of <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6664-math-0006.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6664:mp6664-math-0006\"\/> and <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6664-math-0007.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6664:mp6664-math-0007\"\/> the integral backscatter doses over a tissue\u2010equivalent depth of 2 mm are 11.2% and 21.6% for copper and 24% and 28% for silver, respectively. In contrast, in front of lead there are no obvious differences of the measured backscatter doses at angles between <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6664-math-0008.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6664:mp6664-math-0008\"\/> and <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6664-math-0009.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6664:mp6664-math-0009\"\/> With a further increase of the beam angle from <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6664-math-0010.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6664:mp6664-math-0010\"\/> to <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6664-math-0011.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6664:mp6664-math-0011\"\/> the backscatter dose decreases steeply for all three materials. In front of copper a markedly lower penetrating depth of the backscattered electrons was found for an angle of <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6664-math-0012.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6664:mp6664-math-0012\"\/> compared to <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6664-math-0013.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6664:mp6664-math-0013\"\/> This dependence from the beam angle was less pronounced in front of silver and not detectable in front of lead. In conclusion, the dependence of the backscatter dose from the angle between axial beam and scattering material must be considered, as higher scattering doses have to be considered than previously expected. This may have a clinical impact since the surface of metallic implants is usually curved.<\/jats:p>","DOI":"10.1118\/1.1366664","type":"journal-article","created":{"date-parts":[[2008,6,30]],"date-time":"2008-06-30T23:22:32Z","timestamp":1214868152000},"page":"959-965","source":"Crossref","is-referenced-by-count":21,"title":["Backscatter dose from metallic materials due to obliquely incident high\u2010energy photon beams"],"prefix":"10.1002","volume":"28","author":[{"given":"Roger","family":"Nadrowitz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Feyerabend","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2001,6,12]]},"reference":[{"key":"e_1_2_1_2_1","unstructured":"P. Blockberger and D. Lehmann \u201cDosisuntersuchungen an materialgrenzfl\u00e4chen \u201d inMedizinische Physik\u2010Tagungsband der Deutschen Gesellschaft f\u00fcr Medizinische Physik e.V. 1998 edited by L. Voigtmann and P. Geyer (University Hospital C. G. Carus Technical University of Dresden 1998) pp. 255\u2013256."},{"key":"e_1_2_1_3_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.598205"},{"key":"e_1_2_1_4_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/35\/3\/006"},{"key":"e_1_2_1_5_1","first-page":"366","article-title":"The properties and potential uses of the trimesic acid dosimeter","volume":"167","author":"Nadrowitz R.","year":"1991","journal-title":"Strahlenther. Onkol."},{"key":"e_1_2_1_6_1","unstructured":"J. Roth and H. W. Nemec \u201cR\u00fcckstreuung bei der Bestrahlung mit hochenergetischen Photonen \u201d inMedizinische Physik\u2014Tagungsband der Deutschen Gesellschaft f\u00fcr Medizinische Physik e.V. 1984 edited by Th. Schmidt (Municipal Hospital N\u00fcrnberg 1984) pp. 147\u2013150."},{"key":"e_1_2_1_7_1","doi-asserted-by":"crossref","unstructured":"F. W. Spiers \u201cTransition\u2010zone dosimetry \u201d inRadiation Dosimetry edited by F. H. Attix and E. Tochilin 2nd ed. (Academic New York San Francisco London 1969) Vol. 3 pp. 857\u2013867.","DOI":"10.1016\/B978-0-12-066403-0.50023-5"},{"key":"e_1_2_1_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1010-5182(05)80057-5"},{"key":"e_1_2_1_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-0347(199708)19:5<384::AID-HED4>3.0.CO;2-W"},{"key":"e_1_2_1_10_1","doi-asserted-by":"publisher","DOI":"10.2307\/3579649"},{"key":"e_1_2_1_11_1","doi-asserted-by":"publisher","DOI":"10.3109\/02841869109091835"},{"key":"e_1_2_1_12_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.596345"},{"key":"e_1_2_1_13_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.597594"},{"key":"e_1_2_1_14_1","unstructured":"H. Reich \u201cWechselwirkung ionisierender strahlung mit materie \u201d inDosimetrie ionisierender Strahlung edited by H. Reich (BG Teubner Stuttgart 1990) pp. 53\u201366."},{"key":"e_1_2_1_15_1","first-page":"174","article-title":"Dosimetry using pyromellitic acid and trimellitic acid","volume":"170","author":"Nadrowitz R.","year":"1994","journal-title":"Strahlenther. Onkol."},{"key":"e_1_2_1_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(97)00587-7"},{"key":"e_1_2_1_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/0360-3016(87)90364-6"},{"key":"e_1_2_1_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0958-3947(97)00004-6"},{"key":"e_1_2_1_19_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/7\/1\/305"},{"key":"e_1_2_1_20_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0029-1213385"},{"key":"e_1_2_1_21_1","first-page":"517","article-title":"A parallel\u2010plate small volume chamber for dosimetry of fast electrons and its use","volume":"152","author":"Markus B.","year":"1976","journal-title":"Strahlentherapie"},{"key":"e_1_2_1_22_1","first-page":"86","article-title":"Consideration of inhomogeneities in irradiation planning. 3. Influence of inhomogeneities on the shape of the depth dose curve in water with electronic radiation of different energies","volume":"153","author":"Zwicker H.","year":"1977","journal-title":"Strahlentherapie"},{"key":"e_1_2_1_23_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/27\/3\/003"},{"key":"e_1_2_1_24_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.1702488"},{"key":"e_1_2_1_25_1","first-page":"233","article-title":"Etude de la dose au voisinnage de l' interface entre deux milieux de composition atomique differente, expos\u00e9s aux rayonnement x de 11\u201320 MV","volume":"7","author":"Dutreix J.","year":"1964","journal-title":"Ann. Radiol. (Paris)"},{"key":"e_1_2_1_26_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.596072"}],"container-title":["Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1118%2F1.1366664","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1118%2F1.1366664","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1118\/1.1366664","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,16]],"date-time":"2023-09-16T02:34:49Z","timestamp":1694831689000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1118\/1.1366664"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,6]]},"references-count":25,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2001,6]]}},"alternative-id":["10.1118\/1.1366664"],"URL":"https:\/\/doi.org\/10.1118\/1.1366664","archive":["Portico"],"relation":{},"ISSN":["0094-2405","2473-4209"],"issn-type":[{"value":"0094-2405","type":"print"},{"value":"2473-4209","type":"electronic"}],"subject":[],"published":{"date-parts":[[2001,6]]}}}