{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T09:42:09Z","timestamp":1791193329230,"version":"4.1.0"},"reference-count":32,"publisher":"Wiley","issue":"6Part1","license":[{"start":{"date-parts":[[2006,5,19]],"date-time":"2006-05-19T00:00:00Z","timestamp":1147996800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1"},{"start":{"date-parts":[[2006,5,19]],"date-time":"2006-05-19T00:00:00Z","timestamp":1147996800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions"}],"funder":[{"DOI":"10.13039\/501100000266","name":"Engineering and Physical Sciences Research Council","doi-asserted-by":"publisher","award":["GR\/M52779"],"award-info":[{"award-number":["GR\/M52779"]}],"id":[{"id":"10.13039\/501100000266","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000266","name":"Engineering and Physical Sciences Research Council","doi-asserted-by":"publisher","award":["GR\/N14248\/01"],"award-info":[{"award-number":["GR\/N14248\/01"]}],"id":[{"id":"10.13039\/501100000266","id-type":"DOI","asserted-by":"publisher"}]},{"name":"UK MRC","award":["D2025\/31"],"award-info":[{"award-number":["D2025\/31"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Med. Phys."],"published-print":{"date-parts":[[2006,5,19]]},"DOI":"10.1118\/1.2198315","type":"journal-article","created":{"date-parts":[[2006,7,12]],"date-time":"2006-07-12T22:04:16Z","timestamp":1152741856000},"page":"1758-1769","source":"Crossref","is-referenced-by-count":108,"title":["Factors influencing the accuracy of biomechanical breast models"],"prefix":"10.1002","volume":"33","author":[{"given":"Christine","family":"Tanner","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julia A.","family":"Schnabel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Derek L. G.","family":"Hill","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David J.","family":"Hawkes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin O.","family":"Leach","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D. Rodney","family":"Hose","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2006,5,19]]},"reference":[{"key":"10.1118\/1.2198315-BIB1|rf1","doi-asserted-by":"crossref","unstructured":"F. S. Azar D. N. Metaxas M. D. Schnall A finite model of the breast of predicting mechanical deformations during biopsy procedure 2000 38 45","DOI":"10.1109\/MMBIA.2000.852358"},{"key":"10.1118\/1.2198315-BIB2|rf2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S1361-8415(01)00053-6","article-title":"Methods for modeling and predicting mechanical deformations of the breast under external pertubation","volume":"6","author":"Azar","year":"2002","journal-title":"Med. Image Anal"},{"key":"10.1118\/1.2198315-BIB3|rf3","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1109\/42.921476","article-title":"Biomechanical 3D finite element modeling of the human breast using MRI data","volume":"20","author":"Samani","year":"2001","journal-title":"IEEE Trans. Med. Imaging"},{"key":"10.1118\/1.2198315-BIB4|rf4","doi-asserted-by":"crossref","unstructured":"H. M. Yin L. Z. Sun G. Wang T. Yamada J. Wang M. W. Vannier ImageParser: A tool for finite element generation from three-dimensional medical images 3 31 2004","DOI":"10.1186\/1475-925X-3-31"},{"key":"10.1118\/1.2198315-BIB5|rf5","first-page":"217","volume-title":"Proceedings of MICCAI\u201904","author":"Pathmanathan","year":"2004"},{"key":"10.1118\/1.2198315-BIB6|rf6","first-page":"86","volume-title":"Proceedings of the Workshop on Bildverarbeitung fuer die Medizin","author":"Ruiter","year":"2003"},{"key":"10.1118\/1.2198315-BIB7|rf7","volume-title":"Registration of x-ray mammograms and MR-volumes of the female breast based on simulated mammographic deformation","author":"Ruiter","year":"2003"},{"key":"10.1118\/1.2198315-BIB8|rf8","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1109\/TMI.2002.808367","article-title":"Validation of non-rigid image registration using finite element methods: Application to breast MR images","volume":"22","author":"Schnabel","year":"2003","journal-title":"IEEE Trans. Med. Imaging"},{"key":"10.1118\/1.2198315-BIB9|rf9","doi-asserted-by":"publisher","first-page":"1649","DOI":"10.1088\/0031-9155\/45\/6\/317","article-title":"High-resolution tensor MR elastography for breast tumour detection","volume":"45","author":"Sinkus","year":"2000","journal-title":"Phys. Med. Biol."},{"key":"10.1118\/1.2198315-BIB10|rf10","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1002\/mrm.1111","article-title":"Three-dimensional subzone-based reconstruction algorithm for MR elastography","volume":"45","author":"van Houten","year":"2001","journal-title":"Magn. Reson. Med."},{"key":"10.1118\/1.2198315-BIB11|rf11","doi-asserted-by":"publisher","first-page":"877","DOI":"10.1109\/42.952726","article-title":"A constrained modulus reconstruction technique for breast cancer assessment","volume":"20","author":"Samani","year":"2001","journal-title":"IEEE Trans. Med. Imaging"},{"key":"10.1118\/1.2198315-BIB12|rf12","doi-asserted-by":"crossref","first-page":"1117","DOI":"10.1109\/TMI.2004.830532","article-title":"Modality independent elastography (MIE): A new approach to elasticity imaging","volume":"23","author":"Washington","year":"2004","journal-title":"IEEE Trans. Med. Imaging"},{"key":"10.1118\/1.2198315-BIB13|rf13","doi-asserted-by":"crossref","unstructured":"C. Tanner A. Degenhard J. A. Schnabel A. Castellano-Smith C. Hayes L. I. Sonoda M. O. Leach D. R. Hose D. L. G. Hill D. J. Hawkes A method for the comparison of biomechanical breast models 2001 11 18","DOI":"10.1117\/12.467155"},{"key":"10.1118\/1.2198315-BIB14|rf14","doi-asserted-by":"publisher","first-page":"712","DOI":"10.1109\/42.796284","article-title":"Non-rigid registration using free-form deformations: Application to breast MR images","volume":"18","author":"Rueckert","year":"1999","journal-title":"IEEE Trans. Med. Imaging"},{"key":"10.1118\/1.2198315-BIB15|rf15","first-page":"202","volume-title":"Proceedings of MICCAI\u201999","author":"Ferrant","year":"1999"},{"key":"10.1118\/1.2198315-BIB16|rf16","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1016\/S0031-3203(98)00091-0","article-title":"An overlap invariant entropy measure of 3D medical image alignment","volume":"32","author":"Studholme","year":"1999","journal-title":"Pattern Recogn."},{"key":"10.1118\/1.2198315-BIB17|rf17","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1109\/42.668698","article-title":"A nonparametric method for automatic correction of intensity nonuniformity in MRI data","volume":"17","author":"Sled","year":"1998","journal-title":"IEEE Trans. Med. Imaging"},{"key":"10.1118\/1.2198315-BIB18|rf18","unstructured":"AnalyzeDirect Inc. AnalyzeDirect Inc. < http:\/\/www.analyzedirect.com > 2005"},{"key":"10.1118\/1.2198315-BIB19|rf19","volume-title":"The Visualization Toolkit","author":"Schroeder","year":"1998"},{"key":"10.1118\/1.2198315-BIB20|rf20","unstructured":"Commercial Finite Element Package from ANSYS Inc., 275 Technology Drive, Canonsburg, PA 15317, USA, Version 5.7 and 7.1. < http:\/\/www.ansys.com > 2000"},{"key":"10.1118\/1.2198315-BIB21|rf21","first-page":"69","volume-title":"Proceedings of the International Workshop on Interaction of Ultrasound with Biological Media","author":"Sarvazyan","year":"1994"},{"key":"10.1118\/1.2198315-BIB22|rf22","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1177\/016173469802000403","article-title":"Elastic moduli of breast and prostate tissues under compression","volume":"20","author":"Krouskop","year":"1998","journal-title":"Ultrason. Imaging"},{"key":"10.1118\/1.2198315-BIB23|rf23","unstructured":"P. S. Wellman Harvard University 1999"},{"key":"10.1118\/1.2198315-BIB24|rf24","first-page":"233","article-title":"MR elastography of the breast: Preliminary results","author":"Lawrence","year":"1998","journal-title":"Proceedings of the 6th Scientific Meeting of ISMRM"},{"key":"10.1118\/1.2198315-BIB25|rf25","first-page":"525","article-title":"Assessment of breast cancer by magnetic resonance elastography","author":"Lawrence","year":"1999","journal-title":"Proceedings of the 7th Scientific Meeting of ISMRM"},{"key":"10.1118\/1.2198315-BIB26|rf26","doi-asserted-by":"crossref","first-page":"1411","DOI":"10.2214\/ajr.178.6.1781411","article-title":"MR elastography of breast cancer: Preliminary results","volume":"178","author":"McKnight","year":"2001","journal-title":"Am. J. Roentgenol."},{"key":"10.1118\/1.2198315-BIB27|rf27","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1002\/jmri.10232","article-title":"Initial in vivo experience with steady-state subzone-based MR elastography of the human breast","volume":"17","author":"van Houten","year":"2003","journal-title":"J. Magn. Reson Imaging"},{"key":"10.1118\/1.2198315-BIB28|rf28","volume-title":"Nonlinear Solid Mechanics","author":"Holzapfel","year":"2001"},{"key":"10.1118\/1.2198315-BIB29|rf29","volume-title":"The Finite Element Method: A First Approach","author":"Davis","year":"1980"},{"key":"10.1118\/1.2198315-BIB30|rf30","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1109\/34.24792","article-title":"Principle warps: thin-plate splines and the decomposition of deformations","volume":"11","author":"Bookstein","year":"1989","journal-title":"IEEE Trans. Pattern Anal. Mach. Intell."},{"key":"10.1118\/1.2198315-BIB31|rf31","volume-title":"Sensitivity Analysis in Practice","author":"Saltelli","year":"2004"},{"key":"10.1118\/1.2198315-BIB32|rf32","unstructured":""}],"container-title":["Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1118%2F1.2198315","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1118%2F1.2198315","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full\/10.1118\/1.2198315","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,9]],"date-time":"2025-01-09T21:56:58Z","timestamp":1736459818000},"score":1,"resource":{"primary":{"URL":"http:\/\/doi.wiley.com\/10.1118\/1.2198315"}},"subtitle":["Factors influencing the accuracy of biomechanical breast models"],"short-title":[],"issued":{"date-parts":[[2006,5,19]]},"references-count":32,"journal-issue":{"issue":"6Part1","published-print":{"date-parts":[[2006,6]]}},"URL":"https:\/\/doi.org\/10.1118\/1.2198315","archive":["Portico"],"relation":{},"ISSN":["0094-2405"],"issn-type":[{"value":"0094-2405","type":"print"}],"subject":[],"published":{"date-parts":[[2006,5,19]]}}}