{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,4]],"date-time":"2026-10-04T13:07:06Z","timestamp":1791119226082,"version":"4.1.0"},"reference-count":41,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2006,12,14]],"date-time":"2006-12-14T00:00:00Z","timestamp":1166054400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medical Physics"],"published-print":{"date-parts":[[2007,1]]},"abstract":"<jats:p>The <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp0617-math-0002.png\" xlink:title=\"urn:x-wiley:0094-2405:media:mp0617:mp0617-math-0002\"\/> storage phosphor plate (SPP) is a reusable radiation image detector, widely used in diagnostic computed radiography, x\u2010ray crystallography and radioactive tracer studies. When exposed to ionizing radiation, the SPP stores a latent image until it is scanned with a red reading laser which causes blue photostimulated luminescent (PSL) photons to be emitted. The mechanism of formation of the latent image is still poorly understood, especially for megavoltage photon beams. In order to gain insight into this mechanism and aid applications to high\u2010energy beam dosimetry, the authors have directly determined the SPP generation efficiency, <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp0617-math-0003.png\" xlink:title=\"urn:x-wiley:0094-2405:media:mp0617:mp0617-math-0003\"\/>, the energy required to produce one quantum of emitted PSL when it is irradiated by <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp0617-math-0004.png\" xlink:title=\"urn:x-wiley:0094-2405:media:mp0617:mp0617-math-0004\"\/> and <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp0617-math-0005.png\" xlink:title=\"urn:x-wiley:0094-2405:media:mp0617:mp0617-math-0005\"\/> photon beams. This was done in four steps: 1. The SPP, in a water\u2010equivalent plastic (WEP) phantom, was exposed to a <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp0617-math-0006.png\" xlink:title=\"urn:x-wiley:0094-2405:media:mp0617:mp0617-math-0006\"\/> or <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp0617-math-0007.png\" xlink:title=\"urn:x-wiley:0094-2405:media:mp0617:mp0617-math-0007\"\/> beam, which had been calibrated to give a known absorbed dose to water in a water phantom at the position of the sensitive layer of the SPP. 2. Monte Carlo simulations were used to calculate the ratio of the dose to the sensitive layer in the WEP phantom to the dose to water at the same position in a water phantom. 3. A bleaching experiment was used to determine the number of photons emitted by a plate given a known dose. 4. The generation efficiency was calculated from the number of photons and the dose. This method is much more direct than previous calculations for kilovoltage x\u2010ray beams based on quantum noise analysis. W was found, within experimental uncertainty, to be <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp0617-math-0008.png\" xlink:title=\"urn:x-wiley:0094-2405:media:mp0617:mp0617-math-0008\"\/> for <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp0617-math-0009.png\" xlink:title=\"urn:x-wiley:0094-2405:media:mp0617:mp0617-math-0009\"\/> and <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp0617-math-0010.png\" xlink:title=\"urn:x-wiley:0094-2405:media:mp0617:mp0617-math-0010\"\/> for <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp0617-math-0011.png\" xlink:title=\"urn:x-wiley:0094-2405:media:mp0617:mp0617-math-0011\"\/>, independent of dose. The values for kilovoltage x\u2010ray beams determined previously agree, within their large uncertainty, with these values for megavoltage beams.<\/jats:p>","DOI":"10.1118\/1.2400617","type":"journal-article","created":{"date-parts":[[2007,1,4]],"date-time":"2007-01-04T19:21:12Z","timestamp":1167938472000},"page":"103-111","source":"Crossref","is-referenced-by-count":19,"title":["Dose response of  storage phosphor plates exposed to megavoltage photon beams"],"prefix":"10.1002","volume":"34","author":[{"given":"H. Harold","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Albin L.","family":"Gonzalez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huaying","family":"Ji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dennis M.","family":"Duggan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2006,12,14]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/47\/23\/201"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/1056-8719(94)00089-M"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/0168-9002(88)90458-5"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1007\/3-540-19040-6_13"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1021\/ma00056a038"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.1143793"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.1140740"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1107\/S0909049596006498"},{"key":"e_1_2_6_10_1","first-page":"277","article-title":"Two\u2010dimensional x\u2010ray\u2010diffraction studies on the structural change of actin\u2010filaments during isometric contraction of frog skeletal\u2010muscle by using a new type of integrating area detector (an imaging plate) and synchrotron radiation","volume":"7","author":"Wakabayashi K.","year":"1986","journal-title":"J. Muscle Res. Cell Motil."},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0969-8043(02)00199-9"},{"key":"e_1_2_6_12_1","first-page":"1885","article-title":"Evaluation of a computed radiography system for megavoltage beam dosimetry","volume":"31","author":"Olch A.","year":"2004","journal-title":"Med. Phys."},{"key":"e_1_2_6_13_1","first-page":"1885","article-title":"Evaluation of a computed radiography for IMRT dosimetry","volume":"31","author":"Jurkovic I.","year":"2004","journal-title":"Med. Phys."},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/0168-9002(96)00521-9"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0168-9002(96)00865-0"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0168-9002(98)01238-8"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0168-9002(98)01237-6"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1038\/336089a0"},{"key":"e_1_2_6_19_1","first-page":"401","article-title":"Effect of radiation dose on the photostimulated luminescence of  phosphor","volume":"78","author":"Chouhan M.","year":"2004","journal-title":"Indian J. Phys., A"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1088\/0022-3727\/37\/6\/005"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.598412"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1350-4487(00)00128-1"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1350-4487(00)00163-3"},{"key":"e_1_2_6_24_1","first-page":"29","article-title":"The imaging plate: A new radiation image sensor","volume":"223","author":"Miyahara J.","year":"1989","journal-title":"Chem. Today"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1088\/0953-8984\/13\/5\/329"},{"key":"e_1_2_6_26_1","doi-asserted-by":"publisher","DOI":"10.1002\/1521-396X(200110)187:2<335::AID-PSSA335>3.0.CO;2-Q"},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.3327\/jnst.34.461"},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0168-9002(97)00399-9"},{"key":"e_1_2_6_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-2313(02)00447-7"},{"key":"e_1_2_6_30_1","doi-asserted-by":"publisher","DOI":"10.1088\/0022-3727\/37\/17\/002"},{"key":"e_1_2_6_31_1","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevB.44.9240"},{"key":"e_1_2_6_32_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.596127"},{"key":"e_1_2_6_33_1","doi-asserted-by":"publisher","DOI":"10.1364\/AO.35.003702"},{"key":"e_1_2_6_34_1","volume-title":"Classical Electrodynamics","author":"Jackson J. D.","year":"1975"},{"key":"e_1_2_6_35_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.598691"},{"key":"e_1_2_6_36_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.595446"},{"key":"e_1_2_6_37_1","unstructured":"A. L. Gonzalez 2003 Physics Department of Vanderbilt University"},{"key":"e_1_2_6_38_1","unstructured":"I.Kawrakow E.Mainegra\u2010Hing andD. W. O.Rogers(National Research Council Canada 2003)."},{"key":"e_1_2_6_39_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/47\/7\/303"},{"key":"e_1_2_6_40_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(01)02592-5"},{"key":"e_1_2_6_41_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0969-8043(02)00078-7"},{"key":"e_1_2_6_42_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/48\/20\/003"}],"container-title":["Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1118%2F1.2400617","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1118%2F1.2400617","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1118\/1.2400617","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,17]],"date-time":"2023-09-17T05:16:15Z","timestamp":1694927775000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1118\/1.2400617"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,12,14]]},"references-count":41,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2007,1]]}},"alternative-id":["10.1118\/1.2400617"],"URL":"https:\/\/doi.org\/10.1118\/1.2400617","archive":["Portico"],"relation":{},"ISSN":["0094-2405","2473-4209"],"issn-type":[{"value":"0094-2405","type":"print"},{"value":"2473-4209","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,12,14]]}}}