{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,7,29]],"date-time":"2024-07-29T01:10:18Z","timestamp":1722215418249},"reference-count":41,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2009,2,19]],"date-time":"2009-02-19T00:00:00Z","timestamp":1235001600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"name":"Ministry of Science and Technology (MOST), Republic of Korea","award":["R01-2008-000-10055-0"],"award-info":[{"award-number":["R01-2008-000-10055-0"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medical Physics"],"published-print":{"date-parts":[[2009,3]]},"abstract":"<jats:p>To assess the advantages of the Joint Photographic Experts Group (JPEG)2000 3D (part 2) over JPEG2000 in compressing thin\u2010section abdomen CT data sets, 60 thin\u2010section (0.67 mm) scans from 35 males and 25 females, ranging from 23 to 95 years of age (mean, 58 years), were compressed reversibly (as a negative control) and irreversibly to 4:1, 6:1, 8:1, 10:1, and 12:1 using JPEG2000 3D and JPEG2000 algorithms. Encoding and decoding times and peak signal\u2010to\u2010noise ratios (PSNRs) were measured. For 60 (one image per scan) representative sections containing abnormalities, three radiologists independently compared original and compressed images and graded compression artifacts as 0 (none, indistinguishable), 1 (barely perceptible), 2 (subtle), or 3 (significant). According to pooled radiologists\u2019 responses, the range of visually lossless threshold (VLT, the highest compression ratio at which a compressed image is indistinguishable from its original) was determined as one of <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp5824-math-0001.png\" xlink:title=\"urn:x-wiley:00942405:media:mp5824:mp5824-math-0001\" \/>, 4:1\u20136:1, 6:1\u20138:1, 8:1\u201310:1, 10:1\u201312:1, and <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp5824-math-0002.png\" xlink:title=\"urn:x-wiley:00942405:media:mp5824:mp5824-math-0002\" \/>. Wilcoxon signed rank tests and exact tests for paired proportions were used for the comparisons between the two compressions. At each irreversible compression ratio, compared to JPEG2000, JPEG2000 3D required two\u2010 or threefold greater computing times <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp5824-math-0003.png\" xlink:title=\"urn:x-wiley:00942405:media:mp5824:mp5824-math-0003\" \/> and introduced less artifacts in terms of PSNR <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp5824-math-0004.png\" xlink:title=\"urn:x-wiley:00942405:media:mp5824:mp5824-math-0004\" \/> and the grade (<jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp5824-math-0005.png\" xlink:title=\"urn:x-wiley:00942405:media:mp5824:mp5824-math-0005\" \/> at 6:1 or higher) and the presence of perceived artifacts (<jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp5824-math-0006.png\" xlink:title=\"urn:x-wiley:00942405:media:mp5824:mp5824-math-0006\" \/>, at 6:1 for all readers and at 8:1 for two readers). According to PSNR and readers\u2019 responses, 6:1 and 8:1 JPEG2000 3D compressions showed more artifacts than 4:1 and 6:1 JPEG2000 compressions, respectively, and 10:1 and 12:1 JPEG2000 3D compressions showed similar artifacts to those of 8:1 and 10:1 JPEG2000 compressions, respectively. The determined VLT range was higher for JPEG2000 3D than for JPEG2000 <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp5824-math-0007.png\" xlink:title=\"urn:x-wiley:00942405:media:mp5824:mp5824-math-0007\" \/>: the 3D compression showed the VLT ranges of 4:1\u20136:1, 6:1\u20138:1, and 8:1\u201310:1 for 24 (40%), 30 (50%), and 6 (10%) of the 60 original images, respectively, while the 2D compression showed the VLT ranges of <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp5824-math-0008.png\" xlink:title=\"urn:x-wiley:00942405:media:mp5824:mp5824-math-0008\" \/>, 4:1\u20136:1, and 6:1\u20138:1 for 1 (1.7%), 40 (66.7%), and 19 (31.6%) images, respectively. Compared to JPEG2000, JPEG2000 3D increased the VLT range in 23 of the 60 original images by one <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp5824-math-0009.png\" xlink:title=\"urn:x-wiley:00942405:media:mp5824:mp5824-math-0009\" \/> or two ranges <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp5824-math-0010.png\" xlink:title=\"urn:x-wiley:00942405:media:mp5824:mp5824-math-0010\" \/>, while the remaining 37 images had the same VLT range between the two compressions. In conclusion, compared to JPEG2000 compression, JPEG2000 3D compression yields less artifacts in compressing thin\u2010section abdomen CT images but requires significantly greater computing times. For the tested data set compressed to the range from 4:1 to 12:1, JPEG2000 3D could increase compression level reasonably (by 2 or less in terms of compression ratio) compared to JPEG2000 for the same amount of artifacts.<\/jats:p>","DOI":"10.1118\/1.3075824","type":"journal-article","created":{"date-parts":[[2009,2,25]],"date-time":"2009-02-25T23:24:50Z","timestamp":1235604290000},"page":"835-844","source":"Crossref","is-referenced-by-count":17,"title":["JPEG2000 3D compression vs 2D compression: An assessment of artifact amount and computing time in compressing thin\u2010section abdomen CT images"],"prefix":"10.1002","volume":"36","author":[{"given":"Bohyoung","family":"Kim","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kyoung Ho","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kil Joong","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Richter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Heung\u2010Sik","family":"Kang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"So Yeon","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Young Hoon","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jinwook","family":"Seo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2009,2,19]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10278-005-5163-z"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2403050519"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2452061713"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.07.2304"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.acra.2007.10.018"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.07.3405"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.07.3350"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2482071586"},{"key":"e_1_2_6_10_1","unstructured":"\u201cDICOM Standards Committee Working Group 4: Compression\u2010JPEG2000 transfer syntaxes \u201d National Electrical Manufacturers Association Rosslyn VA Supplement No. 61 2000."},{"key":"e_1_2_6_11_1","first-page":"57","volume-title":"International Congress and Exhibition of Computer Assisted Radiology and Surgery","author":"Siddiqui K.","year":"2004"},{"key":"e_1_2_6_12_1","first-page":"87","volume-title":"Society for Computer Applications in Radiology Scientific Abstracts","author":"Siddiqui K. M.","year":"2004"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1117\/12.596037"},{"key":"e_1_2_6_14_1","unstructured":"A.Tzannes \u201cCompression of 3\u2010dimensional medical image data using part 2 of JPEG 2000 \u201dhttp:\/\/medical.nema.org\/Dicom\/minutes\/WG\u201004\/2004\/2004\u201002\u201018\/3D_compression_RSNA_2003_ver2.pdf."},{"key":"e_1_2_6_15_1","unstructured":"Digital Imaging and Communications in Medicine (DICOM) Supplement 105: JPEG 2000 part 2 multi\u2010component transfer syntaxes ftp:\/\/medical.nema.org\/medical\/dicom\/final\/sup105_ft.doc."},{"key":"e_1_2_6_16_1","unstructured":"ACCURAD J2K\u20133D http:\/\/www.aware.com\/imaging\/accuradj2k3d.htm."},{"key":"e_1_2_6_17_1","unstructured":"PICTools Advanced Compression Technology SDK http:\/\/www.pegasusimaging.com\/pictools.htm."},{"key":"e_1_2_6_18_1","unstructured":"G.Bongartz S. J.Golding A. G.Jurik M.Leonardi E.van Persijn van Meerten R.Rodr\u00edguez K.Schneider A.Calzado J.Geleijns K. A.Jessen W.Panzer P. C.Shrimpton andG.Tosi \u201cEuropean guidelines for multislice computed tomography \u201d funded by the European Commission Contract No. FIGM\u2010CT2000\u201020078\u2010CT\u2010TIP."},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1089\/tmj.2007.0067"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-006-0509-6"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.202.1.8988206"},{"key":"e_1_2_6_22_1","unstructured":"Final report from the video quality experts group on the validation of objective models of video quality assessment http:\/\/www.its.bldrdoc.gov\/vqeg\/projects\/frtv_phaseI\/COM\u201080E_final_report.pdf."},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0165-1684(98)00124-8"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.07.2502"},{"key":"e_1_2_6_25_1","unstructured":"Final report from the video quality experts group on the validation of objective models of video quality assessment phase II http:\/\/www.its.bldrdoc.gov\/vqeg\/projects\/frtv_phaseII\/downloads\/VQEGII_Final_Report.pdf."},{"key":"e_1_2_6_26_1","unstructured":"Digital Imaging and Communications in Medicine (DICOM) Part 14: Gray scale standard display function NEMA Standards Publication So PS 3.14\u20132006 http:\/\/www.nema.org\/stds\/ps3\u20101.cfm."},{"key":"e_1_2_6_27_1","first-page":"117","volume-title":"Digital image warping","author":"Wolberg G.","year":"1990"},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.2830376"},{"key":"e_1_2_6_29_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.215.2.r00ap47543"},{"key":"e_1_2_6_30_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2282011998"},{"key":"e_1_2_6_31_1","article-title":"Regional variance of visually lossless threshold in compressed chest CT Images: Lung versus mediastinum and chest Wall","author":"Kim T. J.","year":"2008","journal-title":"Eur. J. Radiol."},{"key":"e_1_2_6_32_1","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.07.3462"},{"key":"e_1_2_6_33_1","first-page":"87","volume-title":"Non\u2010parametric Statistics for the Behavioral Sciences","author":"Siegel S.","year":"1956"},{"key":"e_1_2_6_34_1","doi-asserted-by":"publisher","DOI":"10.1136\/jech.37.1.82"},{"key":"e_1_2_6_35_1","doi-asserted-by":"publisher","DOI":"10.1037\/0033-2909.86.5.974"},{"key":"e_1_2_6_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.image.2003.08.003"},{"key":"e_1_2_6_37_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.2218316"},{"key":"e_1_2_6_38_1","unstructured":"ITU\u2010R BT \u201c500\u201311 Methodology for the subjective assessment of the quality of television pictures\u201dhttp:\/\/www.dii.unisi.it\/~menegaz\/DoctoralSchool2004\/papers\/ITU\u2010R_BT.500\u201011.pdf."},{"key":"e_1_2_6_39_1","first-page":"572","article-title":"Comparing subjective video quality testing methodologies","volume":"5150","author":"Pinson M.","year":"2003","journal-title":"Proc. SPIE"},{"key":"e_1_2_6_40_1","unstructured":"S.WolfandM.Pinson \u201cVideo quality measurement techniques \u201dhttp:\/\/www.its.bldrdoc.gov\/pub\/ntia\u2010rpt\/02\u2010392\/index.php."},{"key":"e_1_2_6_41_1","doi-asserted-by":"publisher","DOI":"10.5594\/J04337"},{"key":"e_1_2_6_42_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.206.3.9494473"}],"container-title":["Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1118%2F1.3075824","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1118%2F1.3075824","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1118\/1.3075824","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,17]],"date-time":"2023-09-17T23:22:03Z","timestamp":1694992923000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1118\/1.3075824"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,2,19]]},"references-count":41,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2009,3]]}},"alternative-id":["10.1118\/1.3075824"],"URL":"https:\/\/doi.org\/10.1118\/1.3075824","archive":["Portico"],"relation":{},"ISSN":["0094-2405","2473-4209"],"issn-type":[{"value":"0094-2405","type":"print"},{"value":"2473-4209","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,2,19]]}}}