{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T15:15:13Z","timestamp":1792509313214,"version":"4.5.0"},"reference-count":19,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2009,3,11]],"date-time":"2009-03-11T00:00:00Z","timestamp":1236729600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medical Physics"],"published-print":{"date-parts":[[2009,4]]},"abstract":"<jats:p>The authors have developed an experimental fine pitch detector multislice CT scanner with an ultrasmall focal spot x\u2010ray tube and a high\u2010density matrix detector through current CT technology. The latitudinal size of the x\u2010ray tube focal spot was <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6117-math-0001.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6117:mp6117-math-0001\"\/>. The detector dimension was 1824 channels <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6117-math-0002.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6117:mp6117-math-0002\"\/> rows (longitudinal direction) at row width of <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6117-math-0003.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6117:mp6117-math-0003\"\/>, in which a thinner reflected separator surrounds each detector cell coupled with a large active area photodiode. They were mounted on a commercial 64\u2010slice CT scanner gantry while the scan field of view <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6117-math-0004.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6117:mp6117-math-0004\"\/> and gantry rotation speed <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6117-math-0005.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6117:mp6117-math-0005\"\/> can be maintained. The experimental CT scanner demonstrated the spatial resolution of <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6117-math-0006.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6117:mp6117-math-0006\"\/> <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6117-math-0007.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6117:mp6117-math-0007\"\/> with the acrylic slit phantom and in\u2010plane 50%\u2010MTF <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6117-math-0008.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6117:mp6117-math-0008\"\/> and 10%\u2010MTF <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6117-math-0009.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6117:mp6117-math-0009\"\/>. In the longitudinal direction, it demonstrated the spatial resolution of <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6117-math-0010.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6117:mp6117-math-0010\"\/> with the high\u2010resolution insert of the CATPHAN phantom and <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6117-math-0011.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6117:mp6117-math-0011\"\/> as the full width at half maximum of the slice sensitivity profile. In low\u2010contrast detectability, <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6117-math-0012.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6117:mp6117-math-0012\"\/> at 0.3% was visualized at the <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6117-math-0013.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6117:mp6117-math-0013\"\/> of <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6117-math-0014.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6117:mp6117-math-0014\"\/>. Two types of <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp6117-math-0015.png\" xlink:title=\"urn:x-wiley:00942405:media:mp6117:mp6117-math-0015\"\/> diameter vessel phantoms with in\u2010stent stenosis at 25%, 50%, and 75% stair steps were scanned, and the reconstructed images can clearly resolve the stenosis at each case. The experimental CT scanner provides high\u2010resolution imaging while maintaining low\u2010contrast detectability, demonstrating the potentiality for clinical applications demanding high spatial resolution, such as imaging of inner ear, lung, and bone, or low\u2010contrast detectability, such as imaging of coronary artery.<\/jats:p>","DOI":"10.1118\/1.3086117","type":"journal-article","created":{"date-parts":[[2009,3,31]],"date-time":"2009-03-31T07:55:42Z","timestamp":1238486142000},"page":"1120-1127","source":"Crossref","is-referenced-by-count":21,"title":["Development and performance evaluation of an experimental fine pitch detector multislice CT scanner"],"prefix":"10.1002","volume":"36","author":[{"given":"Yasuhiro","family":"Imai","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masatake","family":"Nukui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yotaro","family":"Ishihara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takashi","family":"Fujishige","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kentaro","family":"Ogata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masahiro","family":"Moritake","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haruo","family":"Kurochi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tsuyoshi","family":"Ogata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mitsuru","family":"Yahata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiangyang","family":"Tang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2009,3,11]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031\u20109155\/50\/16\/016"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031\u20109155\/51\/4\/007"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.598473"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.215.1.r00ap3755"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.1949787"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.2722872"},{"key":"e_1_2_6_8_1","first-page":"1417","article-title":"Experimental flat\u2010panel high\u2010spatial\u2010resolution volume CT of the temporal bone","volume":"25","author":"Gupta R.","year":"2004","journal-title":"AJNR Am. J. Neuroradiol."},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1593\/neo.05160"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.2198941"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2453061899"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000111517.69230.0F"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2005.10.058"},{"key":"e_1_2_6_14_1","volume-title":"Computed Tomography: Principles, Design, Artifacts, and Recent Advances","author":"Hsieh J.","year":"2003"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.595583"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1109\/42.959297"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.2836950"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1097\/00004728\u2010197701000\u201000009"},{"key":"e_1_2_6_19_1","first-page":"441","article-title":"Detectability in computed tomography images","volume":"6","author":"Hanson K. M.","year":"1979","journal-title":"Phys. Med. Biol."},{"key":"e_1_2_6_20_1","first-page":"3941","volume-title":"Radiology of the Skull and Brain, Vol. V: Technical Aspects of Computed Tomography","author":"Hanson K. M.","year":"1981"}],"container-title":["Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1118%2F1.3086117","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1118%2F1.3086117","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1118\/1.3086117","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,16]],"date-time":"2023-09-16T11:31:08Z","timestamp":1694863868000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1118\/1.3086117"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,3,11]]},"references-count":19,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2009,4]]}},"alternative-id":["10.1118\/1.3086117"],"URL":"https:\/\/doi.org\/10.1118\/1.3086117","archive":["Portico"],"relation":{},"ISSN":["0094-2405","2473-4209"],"issn-type":[{"value":"0094-2405","type":"print"},{"value":"2473-4209","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,3,11]]}}}