{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T07:49:30Z","timestamp":1789976970445,"version":"4.0.1"},"reference-count":40,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2010,10,29]],"date-time":"2010-10-29T00:00:00Z","timestamp":1288310400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"name":"SNM Student Fellowship"},{"name":"U.S. NCI","award":["24XS036-004 (RIDER)"],"award-info":[{"award-number":["24XS036-004 (RIDER)"]}]},{"name":"U.S. NIH","award":["CA74135"],"award-info":[{"award-number":["CA74135"]}]},{"name":"U.S. NIH","award":["CA113941"],"award-info":[{"award-number":["CA113941"]}]},{"name":"U.S. NIH","award":["CA115870"],"award-info":[{"award-number":["CA115870"]}]},{"name":"U.S. NIH","award":["CA124573"],"award-info":[{"award-number":["CA124573"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medical Physics"],"published-print":{"date-parts":[[2010,11]]},"abstract":"<jats:p><jats:bold>Purpose:<\/jats:bold> The variances and biases inherent in quantifying PET tracer uptake from instrumentation factors are needed to ascertain the significance of any measured differences such as in quantifying response to therapy. The authors studied the repeatability and reproducibility of serial PET measures of activity as a function of object size, acquisition, reconstruction, and analysis method on one scanner and at three PET centers using a single protocol with long half\u2010life phantoms.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> The authors assessed standard deviations (SDs) and mean biases of consecutive measures of PET activity concentrations in a uniform phantom and a NEMA NU\u20102 image quality (IQ) phantom filled with 9 months half\u2010life <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp9298-math-0001.png\" xlink:title=\"urn:x-wiley:00942405:media:mp9298:mp9298-math-0001\"\/> in an epoxy matrix. Activity measurements were normalized by dividing by a common decay corrected true value and reported as recovery coefficients (RCs). Each experimental set consisted of 20 consecutive PET scans of either a stationary phantom to evaluate repeatability or a repositioned phantom to assess reproducibility. One site conducted a comprehensive series of repeatability and reproducibility experiments, while two other sites repeated the reproducibility experiments using the same IQ phantom. An equation was derived to estimate the SD of a new PET measure from a known SD based on the ratios of available coincident counts between the two PET measures.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> For stationary uniform phantom scans, the SDs of maximum RCs were three to five times less than predicted for uncorrelated pixels within circular regions of interest (ROIs) with diameters ranging from 1 to 15 cm. For stationary IQ phantom scans from 1 cm diameter ROIs, the average SDs of mean and maximum RCs ranged from 1.4% to 8.0%, depending on the methods of acquisition and reconstruction (coefficients of variation range 2.5% to 9.8%). Similar SDs were observed for both analytic and iterative reconstruction methods <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp9298-math-0002.png\" xlink:title=\"urn:x-wiley:00942405:media:mp9298:mp9298-math-0002\"\/>. SDs of RCs for 2D acquisitions were significantly higher than for 3D acquisitions <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp9298-math-0003.png\" xlink:title=\"urn:x-wiley:00942405:media:mp9298:mp9298-math-0003\"\/> for same acquisition and processing parameters. SDs of maximum RCs were larger than corresponding mean values for stationary IQ phantom scans <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp9298-math-0004.png\" xlink:title=\"urn:x-wiley:00942405:media:mp9298:mp9298-math-0004\"\/>, although the magnitude of difference is reduced due to noise correlations in the image. Increased smoothing decreased SDs <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp9298-math-0005.png\" xlink:title=\"urn:x-wiley:00942405:media:mp9298:mp9298-math-0005\"\/> and decreased maximum and mean RCs <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp9298-math-0006.png\" xlink:title=\"urn:x-wiley:00942405:media:mp9298:mp9298-math-0006\"\/>. Reproducibility of GE DSTE, Philips Gemini TF, and Siemens Biograph Hi\u2010REZ PET\/CT scans of the same IQ phantom, with similar acquisition, reconstruction, and repositioning among 20 scans, were, in general, similar (mean and maximum RC SD range 2.5% to 4.8%).<\/jats:p><jats:p><jats:bold>Conclusions:<\/jats:bold> Short\u2010term scanner variability is low compared to other sources of error. There are tradeoffs in noise and bias depending on acquisition, processing, and analysis methods. The SD of a new PET measure can be estimated from a known SD if the ratios of available coincident counts between the two PET scanner acquisitions are known and both employ the same ROI definition. Results suggest it is feasible to use PET\/CTs from different vendors and sites in clinical trials if they are properly cross\u2010calibrated.<\/jats:p>","DOI":"10.1118\/1.3499298","type":"journal-article","created":{"date-parts":[[2010,11,2]],"date-time":"2010-11-02T13:04:46Z","timestamp":1288703086000},"page":"6035-6046","source":"Crossref","is-referenced-by-count":69,"title":["Instrumentation factors affecting variance and bias of quantifying tracer uptake with PET\/CT"],"prefix":"10.1002","volume":"37","author":[{"given":"R. K.","family":"Doot","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. S.","family":"Scheuermann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P. E.","family":"Christian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. S.","family":"Karp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P. E.","family":"Kinahan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2010,10,29]]},"reference":[{"key":"e_1_2_7_2_1","first-page":"1059","article-title":"Consensus recommendations for the use of 18F\u2010FDG PET as an indicator of therapeutic response in patients in National Cancer Institute Trials","volume":"47","author":"Shankar L. K.","year":"2006","journal-title":"J. Nucl. Med."},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00259-006-0131-5"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00259-006-0133-3"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.108.057307"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00259-009-1297-4"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1080\/0891060310002230"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1200\/JCO.2003.12.004"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1200\/JCO.2004.07.122"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1200\/JCO.2005.06.965"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1200\/JCO.2005.04.6326"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1470-2045(07)70244-9"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1200\/JCO.2007.15.4385"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00259-008-0874-2"},{"key":"e_1_2_7_15_1","first-page":"1044","article-title":"SUV varies with time after injection in (18)F\u2010FDG PET of breast cancer: Characterization and method to adjust for time differences","volume":"44","author":"Beaulieu S.","year":"2003","journal-title":"J. Nucl. Med."},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00259-006-0224-1"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00259-004-1566-1"},{"key":"e_1_2_7_18_1","first-page":"214","article-title":"Two\u2010dimensional vs three\u2010dimensional imaging in whole body oncologic PET\/CT: A Discovery\u2010STE phantom and patient study","volume":"51","author":"Bettinardi V.","year":"2007","journal-title":"Q. J. Nucl. Med. Mol. Imaging"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1095-0397(99)00016-3"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMra050276"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.196.1.7784562"},{"key":"e_1_2_7_22_1","first-page":"1771","article-title":"Reproducibility of metabolic measurements in malignant tumors using FDG PET","volume":"40","author":"Weber W. A.","year":"1999","journal-title":"J. Nucl. Med."},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11307-008-0132-9"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.108.054239"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/53\/16\/001"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.109.063347"},{"key":"e_1_2_7_27_1","series-title":"IEEE Nuclear Science Symposium Conference Record","first-page":"2833","author":"Doot R. K.","year":"2007"},{"key":"e_1_2_7_28_1","first-page":"392P","article-title":"Performance evaluation of an integrated PET\/CT scanner: Discovery STE","volume":"47","author":"Kinahan P.","year":"2006","journal-title":"J. Nucl. Med."},{"key":"e_1_2_7_29_1","series-title":"Statistics for Experimenters","first-page":"88","author":"Box G. E. P.","year":"1978"},{"key":"e_1_2_7_30_1","doi-asserted-by":"publisher","DOI":"10.1093\/biomet\/52.3-4.591"},{"key":"e_1_2_7_31_1","first-page":"235P","article-title":"Minimizing instrument calibration error to reduce the effect of variability on PET\/CT SUV measurements","volume":"50","author":"Lockhart C.","year":"2009","journal-title":"J. Nucl. Med."},{"key":"e_1_2_7_32_1","series-title":"IEEE Nuclear Science Symposium Conference Record","first-page":"5","author":"Hamill J. J.","year":"2005"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/55\/5\/013"},{"key":"e_1_2_7_34_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.108.057455"},{"key":"e_1_2_7_35_1","doi-asserted-by":"publisher","DOI":"10.1097\/00004728-197906000-00001"},{"key":"e_1_2_7_36_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.106.035774"},{"key":"e_1_2_7_37_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.107.050187"},{"key":"e_1_2_7_38_1","first-page":"63P","article-title":"Multi\u2010center comparison of a PET\/CT calibration phantom for imaging trials","volume":"49","author":"Kinahan P.","year":"2008","journal-title":"J. Nucl. Med."},{"key":"e_1_2_7_39_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3455705"},{"key":"e_1_2_7_40_1","first-page":"1S","article-title":"PET\/CT in cancer patient management. Commentary","volume":"48","author":"Shankar L. K.","year":"2007","journal-title":"J. Nucl. Med."},{"key":"e_1_2_7_41_1","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.108.057182"}],"container-title":["Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1118%2F1.3499298","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1118%2F1.3499298","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1118\/1.3499298","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,18]],"date-time":"2023-09-18T13:24:21Z","timestamp":1695043461000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1118\/1.3499298"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,10,29]]},"references-count":40,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2010,11]]}},"alternative-id":["10.1118\/1.3499298"],"URL":"https:\/\/doi.org\/10.1118\/1.3499298","archive":["Portico"],"relation":{},"ISSN":["0094-2405","2473-4209"],"issn-type":[{"value":"0094-2405","type":"print"},{"value":"2473-4209","type":"electronic"}],"subject":[],"published":{"date-parts":[[2010,10,29]]}}}