{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,4]],"date-time":"2023-10-04T11:42:54Z","timestamp":1696419774531},"reference-count":0,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[1998,6,4]],"date-time":"1998-06-04T00:00:00Z","timestamp":896918400000},"content-version":"vor","delay-in-days":3563,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medical Physics"],"published-print":{"date-parts":[[1988,9]]},"abstract":"<jats:p>Variations in x\u2010ray exposure measurements among a variety of contemporary diagnostic exposure meters are investigated. Variations may result from systematic errors due to calibration, beam\u2010quality dependence and exposure\u2010rate dependence. It is concluded that the majority of general purpose diagnostic meters will agree to within 10% of each other if exposure rates are below 1.3 mC\u2009kg<jats:sup>\u2212<\/jats:sup><jats:sup>1<\/jats:sup>\u2009s<jats:sup>\u2212<\/jats:sup><jats:sup>1<\/jats:sup> of air (5 R\u2009s<jats:sup>\u2212<\/jats:sup><jats:sup>1<\/jats:sup>) and beam qualities are typical for general purpose radiology, excluding mammography. For exposure rates comparable to those in barium enema radiography the variations can range up to 25% or more. Variations up to 40% were observed among general purpose exposure meters at mammographic beam qualities. In the mammographic range, mammographic (thin window) exposure meters varied by no more than 2%.<\/jats:p>","DOI":"10.1118\/1.596189","type":"journal-article","created":{"date-parts":[[2003,3,28]],"date-time":"2003-03-28T15:37:52Z","timestamp":1048865872000},"page":"749-753","source":"Crossref","is-referenced-by-count":8,"title":["Energy and rate dependence of diagnostic x\u2010ray exposure meters"],"prefix":"10.1002","volume":"15","author":[{"given":"Louis K.","family":"Wagner","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frank","family":"Cerra","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Burton","family":"Conway","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas R.","family":"Fewell","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas R.","family":"Ohlhaber","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[1998,6,4]]},"container-title":["Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1118%2F1.596189","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1118%2F1.596189","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1118\/1.596189","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,3]],"date-time":"2023-10-03T12:12:34Z","timestamp":1696335154000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1118\/1.596189"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1988,9]]},"references-count":0,"journal-issue":{"issue":"5","published-print":{"date-parts":[[1988,9]]}},"alternative-id":["10.1118\/1.596189"],"URL":"https:\/\/doi.org\/10.1118\/1.596189","archive":["Portico"],"relation":{},"ISSN":["0094-2405","2473-4209"],"issn-type":[{"value":"0094-2405","type":"print"},{"value":"2473-4209","type":"electronic"}],"subject":[],"published":{"date-parts":[[1988,9]]}}}