{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T08:47:40Z","timestamp":1740127660376,"version":"3.37.3"},"reference-count":35,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2003,10,14]],"date-time":"2003-10-14T00:00:00Z","timestamp":1066089600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"name":"\u201cFunda\u00e7\u00e3o para a Ci\u00eancias e a Tecnologia-Portugal\u201d"},{"DOI":"10.13039\/100012470","name":"CERN","doi-asserted-by":"crossref","award":["CERN\/PAL\/43672\/2001"],"award-info":[{"award-number":["CERN\/PAL\/43672\/2001"]}],"id":[{"id":"10.13039\/100012470","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medical Physics"],"published-print":{"date-parts":[[2003,11]]},"abstract":"<jats:p>In radiosurgery narrow photon beams, the depth of maximum dose <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp8031-math-0001.png\" xlink:title=\"urn:x-wiley:00942405:media:mp8031:mp8031-math-0001\"\/> in the beam central axis increases as the size of the additional collimator increases. This behavior is the opposite of what is observed in radiotherapy conventional beams. To understand this effect, experimental depth dose curves of the additional collimators were obtained for a Siemens KD2 linear accelerator in 6 MV photon mode and the shift of <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp8031-math-0002.png\" xlink:title=\"urn:x-wiley:00942405:media:mp8031:mp8031-math-0002\"\/> varied from <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp8031-math-0003.png\" xlink:title=\"urn:x-wiley:00942405:media:mp8031:mp8031-math-0003\"\/> for the 5 mm collimator to <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp8031-math-0004.png\" xlink:title=\"urn:x-wiley:00942405:media:mp8031:mp8031-math-0004\"\/> for the 23 mm collimator. Monte Carlo simulations showed that the photons that had no interactions in the additional collimators, contributing more than 90% to the total dose in water, were responsible for the shift in <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp8031-math-0005.png\" xlink:title=\"urn:x-wiley:00942405:media:mp8031:mp8031-math-0005\"\/> Monte Carlo simulations also showed that electrons originated from these photons and contributing to the dose deposit in water in the beam central axis could be divided in two groups: those that deposit energy far away from their point of origin (the point of the first photon collision in water) and those that deposit energy locally (originated at more than one photon collision in water). Applying a simplified model based on the fact that the photons originating Compton electrons (at the first and subsequent collisions) have similar characteristics in air for all the additional collimators, it was shown that these electrons were also responsible for the shift of <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp8031-math-0006.png\" xlink:title=\"urn:x-wiley:00942405:media:mp8031:mp8031-math-0006\"\/> in the beam central axis. Finally, it was shown that the changes in the initial gradients of the depth dose curves of the additional collimators were mainly due to electrons originated from the first photon collision in water.<\/jats:p>","DOI":"10.1118\/1.1618031","type":"journal-article","created":{"date-parts":[[2003,11,7]],"date-time":"2003-11-07T14:19:30Z","timestamp":1068214770000},"page":"2904-2911","source":"Crossref","is-referenced-by-count":12,"title":["Basic dosimetry of radiosurgery narrow beams using Monte Carlo simulations: A detailed study of depth of maximum dose"],"prefix":"10.1002","volume":"30","author":[{"given":"A.","family":"Chaves","sequence":"first","affiliation":[]},{"given":"M. C.","family":"Lopes","sequence":"additional","affiliation":[]},{"given":"C. C.","family":"Alves","sequence":"additional","affiliation":[]},{"given":"C.","family":"Oliveira","sequence":"additional","affiliation":[]},{"given":"L.","family":"Peralta","sequence":"additional","affiliation":[]},{"given":"P.","family":"Rodrigues","sequence":"additional","affiliation":[]},{"given":"A.","family":"Trindade","sequence":"additional","affiliation":[]}],"member":"311","published-online":{"date-parts":[[2003,10,14]]},"reference":[{"key":"e_1_2_1_2_1","doi-asserted-by":"crossref","unstructured":"S. M. Seltzer \u201cAn overview of ETRAN Monte Carlo methods \u201d inMonte Carlo Transport of Electrons and Photons edited by T. M. Jenkins W. R. Nelson and A. Rindi (Plenum New York 1988) pp. 153\u2013181.","DOI":"10.1007\/978-1-4613-1059-4_7"},{"key":"e_1_2_1_3_1","doi-asserted-by":"publisher","DOI":"10.2307\/3576517"},{"key":"e_1_2_1_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0168-583X(97)00414-X"},{"key":"e_1_2_1_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0168-583X(86)80027-1"},{"key":"e_1_2_1_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0168-583X(00)00363-3"},{"key":"e_1_2_1_7_1","doi-asserted-by":"crossref","unstructured":"J. A. Halbleib R. P. Kensek T. A. Mehlhirn G. D. Valdez S. M. Seltzer and M. J. Berger \u201cITS version 3.0: the integrated TIGER series of coupled electron\/photon Monte Carlo transport codes \u201d Report SAND91\u20101634 (Sandia National Laboratories Albuquerque NM 1992).","DOI":"10.1109\/23.159753"},{"key":"e_1_2_1_8_1","unstructured":"I. Kawrakow and D. W. O. Rogers \u201cThe EGSnrc code system: Monte Carlo simulation of electron and photon transport \u201d Report PIRS\u2010701 (National Research Council of Canada Ottawa 2000)."},{"key":"e_1_2_1_9_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/44\/9\/303"},{"key":"e_1_2_1_10_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/41\/1\/008"},{"key":"e_1_2_1_11_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/45\/3\/308"},{"key":"e_1_2_1_12_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.597552"},{"key":"e_1_2_1_13_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/45\/8\/315"},{"key":"e_1_2_1_14_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.597673"},{"key":"e_1_2_1_15_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/32\/9\/002"},{"key":"e_1_2_1_16_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.597030"},{"key":"e_1_2_1_17_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.594580"},{"key":"e_1_2_1_18_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.597305"},{"key":"e_1_2_1_19_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.598881"},{"key":"e_1_2_1_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0969-806X(98)00104-2"},{"key":"e_1_2_1_21_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.598613"},{"key":"e_1_2_1_22_1","first-page":"662","article-title":"Monte Carlo MCNP\u20104B\u2010based absorbed dose distribution estimates for patient\u2010specific dosimetry","volume":"42","author":"Yoriyaz H.","year":"2001","journal-title":"J. Nucl. Med."},{"key":"e_1_2_1_23_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/44\/3\/013"},{"key":"e_1_2_1_24_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/45\/7\/304"},{"key":"e_1_2_1_25_1","unstructured":"J. Briesmeister \u201cMCNP\u2010A General Monte Carlo N\u2010particle transport code version 4C \u201d Report LA\u201013709\u2010M (Los Alamos NM Los Alamos National Laboratory 2000)."},{"key":"e_1_2_1_26_1","unstructured":"A. Chaves C. Alves M. Fragoso M. C. Lopes C. Oliveira L. Peralta P. Rodrigues J. Seco and A. Trindade \u201cEGS4 and MCNP4B MC Simulation of a Siemens KD2 Accelerator in 6 MV Photon Mode \u201d Technical Report 01\u201001 LIP Preprint Note http:\/\/weblib.cern.ch\/abstract?EXT\u20102001\u2010008(2001)."},{"key":"e_1_2_1_27_1","unstructured":"M. Fragoso A. Chaves C. Alves M. C. Lopes C. Oliveira L. Peralta and J. Seco \u201cMC simulation of a linear accelerator treatment head\u2010EGS4 and MCNP\u20104B intercomparison \u201d inProceedings of the 8th International Conference On Calorimetry in High Energy Physics edited by G. Barreira B. Tom\u00e9 A. Gomes A. Maio and M. J. Varanda (World Scientific Singapore 1999) pp. 697\u2013702."},{"key":"e_1_2_1_28_1","unstructured":"A. Kenneth and S. Van Riper Sabrina\u2014Visualization in support of MCNP Version 3.63(White Rock Science Los Alamos NM 2002)."},{"key":"e_1_2_1_29_1","unstructured":"R. Brun O. Couet N. L. Cremel C. Vandomi and P. Zanarini PAW\u2010Physics Analysis Workstation CERN program Library Long Writeup Q121 (CERN Geneva 2000)."},{"key":"e_1_2_1_30_1","first-page":"91","article-title":"A proposed method for beam measurements in stereotactic radiotherapy","volume":"16","author":"Lopes M. C.","year":"2000","journal-title":"Phys. Medica"},{"key":"e_1_2_1_31_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/47\/11\/401"},{"key":"e_1_2_1_32_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/45\/4\/313"},{"key":"e_1_2_1_33_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/44\/11\/201"},{"key":"e_1_2_1_34_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/43\/10\/006"},{"key":"e_1_2_1_35_1","unstructured":"A. Trindade \u201cOptimiza\u00e7\u00e3o do c\u00e1lculo de dose por simula\u00e7\u00e3o Monte Carlo em radioterapia externa com feixes de electr\u00f5es \u201d MSc. thesis Faculty of Sciences University of Lisbon http:\/\/www.lip.pt(2002)."},{"key":"e_1_2_1_36_1","unstructured":"L. Lyon Statistics for Nuclear and Particle Physicists(University Press Cambridge 1989) pp. 111\u2013119."}],"container-title":["Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1118%2F1.1618031","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1118%2F1.1618031","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1118\/1.1618031","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,3]],"date-time":"2023-10-03T22:52:23Z","timestamp":1696373543000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1118\/1.1618031"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003,10,14]]},"references-count":35,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2003,11]]}},"alternative-id":["10.1118\/1.1618031"],"URL":"https:\/\/doi.org\/10.1118\/1.1618031","archive":["Portico"],"relation":{},"ISSN":["0094-2405","2473-4209"],"issn-type":[{"type":"print","value":"0094-2405"},{"type":"electronic","value":"2473-4209"}],"subject":[],"published":{"date-parts":[[2003,10,14]]}}}