{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T13:51:56Z","timestamp":1775051516502,"version":"3.50.1"},"reference-count":34,"publisher":"Wiley","issue":"7","license":[{"start":{"date-parts":[[2004,6,24]],"date-time":"2004-06-24T00:00:00Z","timestamp":1088035200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Medical Physics"],"published-print":{"date-parts":[[2004,7]]},"abstract":"<jats:p>Laser wakefield acceleration (LWFA) technology has evolved to where it should be evaluated for its potential as a future competitor to existing technology that produces electron and x\u2010ray beams. The purpose of the present work is to investigate the dosimetric properties of an electron beam that should be achievable using existing LWFA technology, and to document the necessary improvements to make radiotherapy application for LWFA viable. This paper first qualitatively reviews the fundamental principles of LWFA and describes a potential design for a 30 cm accelerator chamber containing a gas target. Electron beam energy spectra, upon which our dose calculations are based, were obtained from a uniform energy distribution and from two\u2010dimensional particle\u2010in\u2010cell (2D PIC) simulations. The 2D PIC simulation parameters are consistent with those reported by a previous LWFA experiment. According to the 2D PIC simulations, only approximately 0.3% of the LWFA electrons are emitted with an energy greater than 1 MeV. We studied only the high\u2010energy electrons to determine their potential for clinical electron beams of central energy from 9 to 21 MeV. Each electron beam was broadened and flattened by designing a dual scattering foil system to produce a uniform beam (103%&gt;off\u2010axis ratio&gt;95%) over a 25\u00d725 cm<jats:sup>2<\/jats:sup>field. An energy window<jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp0194-math-0001.png\" xlink:title=\"urn:x-wiley:00942405:media:mp0194:mp0194-math-0001\"\/>ranging from 0.5 to 6.5 MeV was selected to study central\u2010axis depth dose, beam flatness, and dose rate. Dose was calculated in water at a 100 cm source\u2010to\u2010surface distance using the<jats:sc>EGS\/BEAM<\/jats:sc>Monte Carlo algorithm. Calculations showed that the beam flatness was fairly insensitive to<jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp0194-math-0002.png\" xlink:title=\"urn:x-wiley:00942405:media:mp0194:mp0194-math-0002\"\/>However, since the falloff of the depth\u2013dose curve<jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp0194-math-0003.png\" xlink:title=\"urn:x-wiley:00942405:media:mp0194:mp0194-math-0003\"\/>and the dose rate both increase with<jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp0194-math-0004.png\" xlink:title=\"urn:x-wiley:00942405:media:mp0194:mp0194-math-0004\"\/>a tradeoff between minimizing<jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp0194-math-0005.png\" xlink:title=\"urn:x-wiley:00942405:media:mp0194:mp0194-math-0005\"\/>and maximizing dose rate is implied. If<jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp0194-math-0006.png\" xlink:title=\"urn:x-wiley:00942405:media:mp0194:mp0194-math-0006\"\/>is constrained so that<jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp0194-math-0007.png\" xlink:title=\"urn:x-wiley:00942405:media:mp0194:mp0194-math-0007\"\/>is within 0.5 cm of its value for a monoenergetic beam, the maximum practical dose rate based on 2D PIC is approximately 0.1 Gy min<jats:sup>\u22121<\/jats:sup>for a 9 MeV beam and 0.03 Gy min<jats:sup>\u22121<\/jats:sup>for a 15 MeV beam. It was concluded that current LWFA technology should allow a table\u2010top terawatt<jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/mp0194-math-0008.png\" xlink:title=\"urn:x-wiley:00942405:media:mp0194:mp0194-math-0008\"\/>laser to produce therapeutic electron beams that have acceptable flatness, penetration, and falloff of depth dose; however, the dose rate is still 1%\u20133% of that which would be acceptable, especially for higher\u2010energy electron beams. Further progress in laser technology, e.g., increasing the pulse repetition rate or number of high energy electrons generated per pulse, is necessary to give dose rates acceptable for electron beams. Future measurements confirming dosimetric calculations are required to substantiate our results. In addition to achieving adequate dose rate, significant engineering developments are needed for this technology to compete with current electron acceleration technology. Also, the functional benefits of LWFA electron beams require further study and evaluation.<\/jats:p>","DOI":"10.1118\/1.1690194","type":"journal-article","created":{"date-parts":[[2004,7,6]],"date-time":"2004-07-06T22:09:09Z","timestamp":1089151749000},"page":"2053-2067","source":"Crossref","is-referenced-by-count":31,"title":["Dose properties of a laser accelerated electron beam and prospects for clinical application"],"prefix":"10.1002","volume":"31","author":[{"given":"K. K.","family":"Kainz","sequence":"first","affiliation":[]},{"given":"K. R.","family":"Hogstrom","sequence":"additional","affiliation":[]},{"given":"J. A.","family":"Antolak","sequence":"additional","affiliation":[]},{"given":"P. R.","family":"Almond","sequence":"additional","affiliation":[]},{"given":"C. D.","family":"Bloch","sequence":"additional","affiliation":[]},{"given":"C.","family":"Chiu","sequence":"additional","affiliation":[]},{"given":"M.","family":"Fomytskyi","sequence":"additional","affiliation":[]},{"given":"F.","family":"Raischel","sequence":"additional","affiliation":[]},{"given":"M.","family":"Downer","sequence":"additional","affiliation":[]},{"given":"T.","family":"Tajima","sequence":"additional","affiliation":[]}],"member":"311","published-online":{"date-parts":[[2004,6,24]]},"reference":[{"key":"e_1_2_1_2_1","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevLett.43.267"},{"key":"e_1_2_1_3_1","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevLett.84.670"},{"key":"e_1_2_1_4_1","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevLett.84.4108"},{"key":"e_1_2_1_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0168-9002(00)00720-8"},{"key":"e_1_2_1_6_1","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevLett.89.085002"},{"key":"e_1_2_1_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0167-8140(97)00077-7"},{"key":"e_1_2_1_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/0360-3016(90)90149-E"},{"key":"e_1_2_1_9_1","unstructured":"K. R. Hogstrom J. A. Antolak R. J. Kudchadker C.\u2010M. Ma and D. D. Leavitt \u201cModulated Electron Therapy \u201d inIntensity Modulated Radiotherapy edited by T. R. Mackie and J. R. Palta Proceedings of the AAPM 2003 Summer School (Medical Physics Publishing Madison WI 2003) pp. 749\u2013786."},{"key":"e_1_2_1_10_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.1739301"},{"key":"e_1_2_1_11_1","doi-asserted-by":"publisher","DOI":"10.1109\/27.509991"},{"key":"e_1_2_1_12_1","unstructured":"J. D. Jackson Classical Electrodynamics 2nd ed. (Wiley New York 1975) p. 492."},{"key":"e_1_2_1_13_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.871728"},{"key":"e_1_2_1_14_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.860884"},{"key":"e_1_2_1_15_1","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevE.48.2157"},{"key":"e_1_2_1_16_1","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevLett.78.3125"},{"key":"e_1_2_1_17_1","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevLett.79.3909"},{"key":"e_1_2_1_18_1","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevLett.80.2133"},{"key":"e_1_2_1_19_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.1352617"},{"key":"e_1_2_1_20_1","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevE.53.1844"},{"key":"e_1_2_1_21_1","unstructured":"F. Raischel \u201cA laser electron accelerator system for radiation therapy \u201d M.A. thesis The University of Texas at Austin 2001 (unpublished)."},{"key":"e_1_2_1_22_1","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevLett.70.37"},{"key":"e_1_2_1_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/0030-4018(85)90120-8"},{"key":"e_1_2_1_24_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.882131"},{"key":"e_1_2_1_25_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.1524920"},{"key":"e_1_2_1_26_1","unstructured":"R. L. Jones III \u201cCompact laser\u2010driven medical electron accelerators \u201d M.A. thesis The University of Texas at Austin 1999 (unpublished)."},{"key":"e_1_2_1_27_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.1521122"},{"key":"e_1_2_1_28_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.595617"},{"key":"e_1_2_1_29_1","doi-asserted-by":"crossref","unstructured":"N. Leveson and C. Turner \u201cAn Investigation of the Therac\u201025 Accidents \u201d inEthics and Computing: Living Responsibly in a Computerized World edited by K. W. Bowyer (IEEE Computer Society Press Los Alamitos CA 1996) pp. 18\u201341.","DOI":"10.1109\/MC.1993.274940"},{"key":"e_1_2_1_30_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.597552"},{"key":"e_1_2_1_31_1","doi-asserted-by":"crossref","unstructured":"W. R. Nelson H. Hirayama and D. W. O. Rogers \u201cThe EGS4 code system \u201d Stanford Linear Accelerator Center Report No. SLAC\u2010265 Stanford CA 1985.","DOI":"10.2172\/1453993"},{"key":"e_1_2_1_32_1","unstructured":"A. D. Green \u201cModeling of dual foil scattering systems for clinical electron beams \u201d M. S. thesis The University of Texas Health Science Center at Houston 1991 (unpublished)."},{"key":"e_1_2_1_33_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/34\/10\/003"},{"key":"e_1_2_1_34_1","unstructured":"ICRU \u201cRadiation dosimetry: Electron beams with energies between 1 and 50 MeV \u201d ICRU Report No. 35 Bethesda MD 1984."},{"key":"e_1_2_1_35_1","doi-asserted-by":"publisher","DOI":"10.1007\/s003400000320"}],"container-title":["Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1118%2F1.1690194","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1118%2F1.1690194","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1118\/1.1690194","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,17]],"date-time":"2024-12-17T20:48:51Z","timestamp":1734468531000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1118\/1.1690194"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,6,24]]},"references-count":34,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2004,7]]}},"alternative-id":["10.1118\/1.1690194"],"URL":"https:\/\/doi.org\/10.1118\/1.1690194","archive":["Portico"],"relation":{},"ISSN":["0094-2405","2473-4209"],"issn-type":[{"value":"0094-2405","type":"print"},{"value":"2473-4209","type":"electronic"}],"subject":[],"published":{"date-parts":[[2004,6,24]]}}}