{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T14:02:13Z","timestamp":1787061733592,"version":"build-2736575974"},"reference-count":14,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2014,9,8]],"date-time":"2014-09-08T00:00:00Z","timestamp":1410134400000},"content-version":"vor","delay-in-days":7,"URL":"http:\/\/creativecommons.org\/licenses\/by\/3.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Applied Clin Med Phys"],"published-print":{"date-parts":[[2014,9]]},"abstract":"<jats:p>\n                    Due to a lack of information regarding the current clinical experience of IMRT QA for a large and varied plan population, we reviewed our patient\u2010specific IMRT quality assurance (QA) results for 13,003 treatment plans from 13 distinct treatment sites from a six\u2010year period. QA records were reviewed for dose difference (single point with ion chamber measurement;\n                    <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/acm20196-math-0001.png\" xlink:title=\"urn:x-wiley:15269914:media:acm20196:acm20196-math-0001\"\/>\n                    agreement criteria) and percentage of pixels passing relative dose gamma analysis (film measurement; 90% passing 5%(global)\/3 mm agreement criteria) from 2005 through 2011. Plan records were analyzed for trends with measurement date and treatment site. Plans failing to meet QA tolerance criteria were evaluated for follow\u2010up clinical action (i.e., if repeat measurements were performed). The mean difference (\n                    <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/acm20196-math-0002.png\" xlink:title=\"urn:x-wiley:15269914:media:acm20196:acm20196-math-0002\"\/>\n                    ) between ion chamber point measurements and calculated doses was\n                    <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/acm20196-math-0003.png\" xlink:title=\"urn:x-wiley:15269914:media:acm20196:acm20196-math-0003\"\/>\n                    <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/acm20196-math-0004.png\" xlink:title=\"urn:x-wiley:15269914:media:acm20196:acm20196-math-0004\"\/>\n                    (calculated values being slightly higher) and, regarding planar dose evaluations, the mean percentage of pixels passing the gamma criteria of 5%(global)\/3 mm was 97.7% (lower 95th percentile: 92.2%). 97.7% and 99.3% of plans passed the point dose and planar dose verification, respectively. We observed statistically significant differences (\n                    <jats:inline-graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"graphic\/acm20196-math-0005.png\" xlink:title=\"urn:x-wiley:15269914:media:acm20196:acm20196-math-0005\"\/>\n                    ) in both point dose and planar dose verification measurements as a function of treatment site (particularly for stereotactic spine and mesothelioma sites) and measurement date (average agreement improved with time). However, despite improved dosimetric agreement, the percentage of failing plans has remained nearly constant at 2.3%.\n                  <\/jats:p>\n                  <jats:p>PACS numbers: 87.55.Qr, 87.55.km, 87.56.Fc<\/jats:p>","DOI":"10.1120\/jacmp.v15i5.4935","type":"journal-article","created":{"date-parts":[[2017,2,27]],"date-time":"2017-02-27T18:39:09Z","timestamp":1488220749000},"page":"196-206","source":"Crossref","is-referenced-by-count":39,"title":["A six\u2010year review of more than 13,000 patient\u2010specific IMRT QA results from 13 different treatment sites"],"prefix":"10.1002","volume":"15","author":[{"given":"Kiley B.","family":"Pulliam","sequence":"first","affiliation":[{"name":"The University of Texas Graduate School of Biomedical Sciences at Houston  Houston TX"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Followill","sequence":"additional","affiliation":[{"name":"Department of Radiation Physics The University of Texas MD Anderson Cancer Center  Houston TX"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laurence","family":"Court","sequence":"additional","affiliation":[{"name":"Department of Radiation Physics The University of Texas MD Anderson Cancer Center  Houston TX"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lei","family":"Dong","sequence":"additional","affiliation":[{"name":"The University of Texas Graduate School of Biomedical Sciences at Houston  Houston TX"},{"name":"Department of Radiation Oncology Scripps Proton Therapy Center  San Diego CA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Gillin","sequence":"additional","affiliation":[{"name":"Department of Radiation Physics The University of Texas MD Anderson Cancer Center  Houston TX"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karl","family":"Prado","sequence":"additional","affiliation":[{"name":"University of Maryland School of Medicine  Baltimore MD USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen F.","family":"Kry","sequence":"additional","affiliation":[{"name":"Department of Radiation Physics The University of Texas MD Anderson Cancer Center  Houston TX"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2014,9,8]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4736949"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3633904"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3397807"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.radonc.2007.11.007"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.4711755"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3425781"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3544657"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3238104"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0360-3016(03)00197-4"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1186\/1748-717X-6-85"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/56\/23\/007"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v8i3.2448"},{"key":"e_1_2_7_14_1","volume-title":"An evaluation of the consistency of IMRT patient\u2010specific QA techniques [thesis]","author":"McKenzie EM","year":"2013"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1120\/jacmp.v9i3.2721"}],"container-title":["Journal of Applied Clinical Medical Physics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1120%2Fjacmp.v15i5.4935","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1120%2Fjacmp.v15i5.4935","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/pdf\/10.1120\/jacmp.v15i5.4935","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,5]],"date-time":"2023-10-05T16:33:14Z","timestamp":1696523594000},"score":1,"resource":{"primary":{"URL":"https:\/\/aapm.onlinelibrary.wiley.com\/doi\/10.1120\/jacmp.v15i5.4935"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,9]]},"references-count":14,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2014,9]]}},"alternative-id":["10.1120\/jacmp.v15i5.4935"],"URL":"https:\/\/doi.org\/10.1120\/jacmp.v15i5.4935","archive":["Portico"],"relation":{},"ISSN":["1526-9914","1526-9914"],"issn-type":[{"value":"1526-9914","type":"print"},{"value":"1526-9914","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,9]]}}}