{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T16:01:17Z","timestamp":1759939277723},"reference-count":22,"publisher":"Acoustical Society of America (ASA)","issue":"1","content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2002,7,1]]},"abstract":"<jats:p>A recently proposed noise reduction system intended to facilitate the assessment of click-evoked otoacoustic emission (CEOAE) in noisy environments [Comput. Biol. Med. 30, 341 (2000)] is evaluated using 13 normally hearing ears and 9 ears with a sensorineural hearing loss. The noise reduction system is based on an adaptive noise canceller design using an additional noise-only reference microphone and intended to reduce externally generated noise. The system is tested in quiet and at different levels of white noise. The three main design parameters of the noise reduction system (adaptation time constant, length of the adaptive filter, and position of the noise reference microphone) are varied systematically in different experiments. With the noise reduction system active, CEOAE can be assessed correctly at noise levels which are 5 to 9 dB higher than without the noise reduction system. For the range of adaptation time constants considered (65.6 to 656 ms), no statistically significant effect on the amount of noise reduction is observed. Noise reduction is highest when the reference microphone is positioned close to the ear probe. Using this reference microphone position and adaptive filters of 6.56 ms in length, average noise reductions of 7.17 to 8.50 dB are achieved.<\/jats:p>","DOI":"10.1121\/1.1488138","type":"journal-article","created":{"date-parts":[[2002,7,28]],"date-time":"2002-07-28T22:21:46Z","timestamp":1027894906000},"page":"164-171","update-policy":"http:\/\/dx.doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":9,"title":["Evaluation of a noise reduction system for the assessment of click-evoked otoacoustic emissions"],"prefix":"10.1121","volume":"112","author":[{"given":"Pascal","family":"M\u00fcller","sequence":"first","affiliation":[{"name":"Department of ENT, Head, Neck and Cranio-Maxillo-Facial Surgery, Inselspital, University of Berne, 3010 Bern, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martin","family":"Kompis","sequence":"additional","affiliation":[{"name":"Department of ENT, Head, Neck and Cranio-Maxillo-Facial Surgery, Inselspital, University of Berne, 3010 Bern, Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"231","published-online":{"date-parts":[[2002,7,2]]},"reference":[{"key":"2023071406291781000_ber86","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.1121\/1.393228","article-title":"Methods of measuring the attenuation of hearing protection devices","volume":"79","year":"1986","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071406291781000_bru99"},{"key":"2023071406291781000_col90","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/0378-5955(90)90232-E","article-title":"Effect of contralateral auditory stimuli on active cochlear micro-mechanical properties in human subjects","volume":"43","year":"1990","journal-title":"Hear. Res."},{"key":"2023071406291781000_jac94","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/0165-5876(94)90170-8","article-title":"The effects of noise in transient EOAE newborn hearing screening","volume":"29","year":"1994","journal-title":"Int. J. Pediatr. Otorhinolaryngol."},{"key":"2023071406291781000_jan01"},{"key":"2023071406291781000_kem78","doi-asserted-by":"crossref","first-page":"1386","DOI":"10.1121\/1.382104","article-title":"Stimulated acoustic emissions from within the human auditory system","volume":"64","year":"1978","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071406291781000_kem91","first-page":"73","article-title":"Otoacoustic emissions tests in neonatal screening programs","volume":"482","year":"1991","journal-title":"Acta Oto-Laryngol., Suppl."},{"key":"2023071406291781000_kem90","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1097\/00003446-199004000-00004","article-title":"A guide to the effective use of otoacoustic emissions","volume":"11","year":"1990","journal-title":"Ear Hear."},{"key":"2023071406291781000_kom1a","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1121\/1.1338557","article-title":"Performance of an adaptive beamforming noise reduction scheme for hearing aid applications. I. Prediction of the signal-to-noise-ratio improvement","volume":"109","year":"2001","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071406291781000_kom1b","doi-asserted-by":"crossref","first-page":"1134","DOI":"10.1121\/1.1338558","article-title":"Performance of an adaptive beamforming noise reduction scheme for hearing aid applications. II. Experimental verification of the predictions","volume":"109","year":"2001","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071406291781000_kom00","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/S0010-4825(00)00018-4","article-title":"A novel real-time noise reduction system for the assessment of evoked otoacoustic emissions","volume":"30","year":"2000","journal-title":"Comput. Biol. Med."},{"key":"2023071406291781000_lin86","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1121\/1.394061","article-title":"Two-ear correlation in the statistical sound field of rooms","volume":"80","year":"1986","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071406291781000_maa00","doi-asserted-by":"crossref","first-page":"2272","DOI":"10.1121\/1.1312357","article-title":"Noise-evoked otoacoustic emissions in humans","volume":"108","year":"2000","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071406291781000_mot89","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/0378-5955(89)90068-3","article-title":"Changes in spontaneous otoacoustic emissions produced by acoustic stimulation of the contralateral ear","volume":"38","year":"1989","journal-title":"Hear. Res."},{"key":"2023071406291781000_pat98","doi-asserted-by":"crossref","first-page":"2483","DOI":"10.1121\/1.422769","article-title":"An adaptive noise reduction stethoscope for auscultation in high noise environments","volume":"103","year":"1998","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071406291781000_pop98","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1097\/00003446-199808000-00007","article-title":"Identification of noise sources that influence distortion product otoacoustic emission measurements in human neonates","volume":"19","year":"1998","journal-title":"Ear Hear."},{"key":"2023071406291781000_pro91","doi-asserted-by":"crossref","first-page":"2027","DOI":"10.1121\/1.400897","article-title":"A review of otoacoustic emissions","volume":"89","year":"1991","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071406291781000_rho98","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1097\/00003446-199812000-00006","article-title":"Effects of background noise on click-evoked otoacoustic emissions","volume":"19","year":"1998","journal-title":"Ear Hear."},{"key":"2023071406291781000_sch98","first-page":"823","article-title":"Zur diagnostischen Wertigkeit otoakustischer Emissionen\u2014Teil 2. Klinische Einsatzf\u00e4higkeit der OAE [Diagnostic value of otoacoustic emissions\u2014Part 2. Clinical usefulness of OAE]","volume":"46","year":"1998","journal-title":"HNO"},{"key":"2023071406291781000_van98","doi-asserted-by":"crossref","first-page":"3621","DOI":"10.1121\/1.423066","article-title":"An adaptive noise canceller for hearing aids using two nearby microphones","volume":"103","year":"1998","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071406291781000_wid75","doi-asserted-by":"crossref","first-page":"1692","DOI":"10.1109\/PROC.1975.10036","article-title":"Adaptive noise canceling: Principles and applications","volume":"63","year":"1975","journal-title":"Proc. IEEE"},{"key":"2023071406291781000_wil80","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1016\/0378-5955(80)90060-X","article-title":"Evidence for a cochlear origin for acoustic re-emissions, threshold fine-structure and tonal tinnitus","volume":"2","year":"1980","journal-title":"Hear. Res."}],"container-title":["The Journal of the Acoustical Society of America"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/asa\/jasa\/article-pdf\/112\/1\/164\/7386706\/164_1_online.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/asa\/jasa\/article-pdf\/112\/1\/164\/7386706\/164_1_online.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,14]],"date-time":"2023-07-14T06:56:15Z","timestamp":1689317775000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/jasa\/article\/112\/1\/164\/550089\/Evaluation-of-a-noise-reduction-system-for-the"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2002,7,1]]},"references-count":22,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2002,7,1]]}},"URL":"https:\/\/doi.org\/10.1121\/1.1488138","relation":{},"ISSN":["0001-4966","1520-8524"],"issn-type":[{"value":"0001-4966","type":"print"},{"value":"1520-8524","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2002,7]]},"published":{"date-parts":[[2002,7,1]]}}}