{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T21:34:51Z","timestamp":1788471291242,"version":"build-2803163510"},"reference-count":36,"publisher":"Acoustical Society of America (ASA)","issue":"1","content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2010,7,1]]},"abstract":"<jats:p>Egg white, a protein-containing solution, is characterized as a blood coagulation surrogate for the acoustical and thermal evaluation of therapeutic ultrasound, especially high intensity focused ultrasound (HIFU) devices. Physical properties, including coagulation temperature, frequency dependent attenuation, sound speed, viscosity, and thermal properties, were measured as a function of temperature (20\u201395\u2009\u00b0C). Thermal coagulation and attenuation (5\u201312 and 1 MHz) of cow blood, pig blood, and human blood also were assessed and compared with egg white. For a 30 s thermal exposure, both egg white and blood samples (3 mm thickness) started to denature at 65\u2009\u00b0C and coagulate into an elastic gel at 85\u2009\u00b0C. The attenuation of egg white was found to be similar to that of the blood samples, having values of 0.23f1.09, 1.58f0.61, and 2.7f0.5\u2002dB\/cm at 20, 75, and 95\u2009\u00b0C, respectively. This significant attenuation increase with temperature was determined to be caused mainly by bubble cavity formation. The other temperature-dependent parameters are also similar to the reported values for blood. These properties make egg white a potentially useful bench testing tool for the safety and efficacy evaluation of therapeutic ultrasound devices.<\/jats:p>","DOI":"10.1121\/1.3442361","type":"journal-article","created":{"date-parts":[[2010,7,19]],"date-time":"2010-07-19T15:51:11Z","timestamp":1279554671000},"page":"480-489","update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":11,"title":["Egg white as a blood coagulation surrogate"],"prefix":"10.1121","volume":"128","author":[{"given":"Yunbo","family":"Liu","sequence":"first","affiliation":[{"name":"Food and Drug Administration Center for Devices and Radiological Health, , Building 62, 10903 New Hampshire Avenue, Silver Spring, Maryland 20993"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Subha","family":"Maruvada","sequence":"additional","affiliation":[{"name":"Food and Drug Administration Center for Devices and Radiological Health, , Building 62, 10903 New Hampshire Avenue, Silver Spring, Maryland 20993"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bruce A.","family":"Herman","sequence":"additional","affiliation":[{"name":"Food and Drug Administration Center for Devices and Radiological Health, , Building 62, 10903 New Hampshire Avenue, Silver Spring, Maryland 20993"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerald R.","family":"Harris","sequence":"additional","affiliation":[{"name":"Food and Drug Administration Center for Devices and Radiological Health, , Building 62, 10903 New Hampshire Avenue, Silver Spring, Maryland 20993"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"231","published-online":{"date-parts":[[2010,7,16]]},"reference":[{"key":"2023071905090581200_c1","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1134\/1.1591291","article-title":"Physical mechanisms of the therapeutic effect of ultrasound","volume":"49","year":"2003","journal-title":"Acoust. Phys."},{"key":"2023071905090581200_c2","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1021\/j150319a013","article-title":"The denaturation of albumin","volume":"35","year":"1931","journal-title":"J. Phys. Chem."},{"key":"2023071905090581200_c3","doi-asserted-by":"crossref","first-page":"137","DOI":"10.7863\/jum.1988.7.3.137","article-title":"Performance tests of Doppler ultrasound equipment with a tissue and blood mimicking phantom","volume":"7","year":"1988","journal-title":"J. Ultrasound Med."},{"key":"2023071905090581200_c4","volume-title":"Hematology: Principles and Procedures","year":"1988"},{"key":"2023071905090581200_c5","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/S0929-8266(99)00005-1","article-title":"Treatment of localized prostate cancer with transrectal high intensity focused ultrasound","volume":"9","year":"1999","journal-title":"Eur. J. Ultrasound"},{"key":"2023071905090581200_c6","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1007\/s11934-003-0077-0","article-title":"The status of high-intensity focused ultrasound in the treatment of localized prostate cancer and the impact of a combined resection","volume":"4","year":"2003","journal-title":"Curr. Urol. Rep."},{"key":"2023071905090581200_c7","doi-asserted-by":"publisher","first-page":"1661","DOI":"10.1088\/0031-9155\/38\/11\/011","article-title":"Effect of blood perfusion on the ablation of liver parenchyma with high-intensity focused ultrasound","volume":"38","year":"1993","journal-title":"Phys. Med. Biol."},{"key":"2023071905090581200_c8","doi-asserted-by":"publisher","first-page":"981","DOI":"10.1016\/j.ultrasmedbio.2006.11.021","article-title":"Thermal properties and changes of acoustic parameters in an egg white phantom during heating and coagulation by high intensity focused ultrasound","volume":"33","year":"2007","journal-title":"Ultrasound Med. Biol."},{"key":"2023071905090581200_c9","volume-title":"Physical Properties of Tissue: A Complete Reference Book","year":"1990"},{"key":"2023071905090581200_c10","doi-asserted-by":"publisher","first-page":"111","DOI":"10.2217\/14796694.2.1.111","article-title":"Potential role of pulsed-high intensity focused ultrasound in gene therapy","volume":"2","year":"2006","journal-title":"Future Oncol."},{"key":"2023071905090581200_c11","doi-asserted-by":"publisher","first-page":"1036","DOI":"10.1109\/TUFFC.2007.349","article-title":"An ultrasonic time delay spectrometry (TDS) system employing digital processing","volume":"54","year":"2007","journal-title":"IEEE Trans. Ultrason. Ferroelectr. Freq. Control"},{"key":"2023071905090581200_c12","doi-asserted-by":"publisher","first-page":"1269","DOI":"10.1016\/j.ultrasmedbio.2007.02.011","article-title":"Pulsatile flow phantom for ultrasound image-guided HIFU treatment of vascular injuries","volume":"33","year":"2007","journal-title":"Ultrasound Med. Biol."},{"key":"2023071905090581200_c13","doi-asserted-by":"publisher","first-page":"2451","DOI":"10.1121\/1.1787124","article-title":"Experimental validation of a tractable numerical model for focused ultrasound heating in flow-through tissue phantoms","volume":"116","year":"2004","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071905090581200_c14","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1148\/radiology.219.1.r01ap02176","article-title":"MR imaging-guided focused ultrasound surgery of fibroadenomas in the breast: A feasibility study","volume":"219","year":"2001","journal-title":"Radiology"},{"key":"2023071905090581200_c15","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1016\/j.ultrasmedbio.2006.08.016","article-title":"Blood flow occlusion via ultrasound image-guided high-intensity focused ultrasound and its effect on tissue perfusion","volume":"33","year":"2007","journal-title":"Ultrasound Med. Biol."},{"key":"2023071905090581200_c16","doi-asserted-by":"publisher","first-page":"851","DOI":"10.1016\/j.ultrasmedbio.2004.03.011","article-title":"Contrast-enhanced ultrasound assessment of tissue response to high-intensity focused ultrasound","volume":"30","year":"2004","journal-title":"Ultrasound Med. Biol."},{"key":"2023071905090581200_c17","first-page":"351","article-title":"Development of a HIFU phantom","year":"2006"},{"key":"2023071905090581200_c18","doi-asserted-by":"publisher","first-page":"391","DOI":"10.3357\/ASEM.2375.2009","article-title":"Focused ultrasound: Concept for automated transcutaneous control of hemorrhage in austere settings","volume":"80","year":"2009","journal-title":"Aviat. Space Environ. Med."},{"key":"2023071905090581200_c19","doi-asserted-by":"publisher","first-page":"1383","DOI":"10.1016\/j.ultrasmedbio.2005.06.004","article-title":"Gel phantom for use in high-intensity focused ultrasound dosimetry","volume":"31","year":"2005","journal-title":"Ultrasound Med. Biol."},{"key":"2023071905090581200_c20","volume-title":"Clinical Arterial Blood Gas Analysis","year":"1987"},{"key":"2023071905090581200_c21","doi-asserted-by":"publisher","first-page":"1803","DOI":"10.1121\/1.2956469","article-title":"Development and characterization of a blood mimicking fluid for high intensity focused ultrasound","volume":"124","year":"2008","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071905090581200_c22","doi-asserted-by":"crossref","first-page":"615","DOI":"10.7863\/jum.1999.18.9.615","article-title":"Interlaboratory comparison of ultrasonic backscatter, attenuation, and speed measurements","volume":"18","year":"1999","journal-title":"J. Ultrasound Med."},{"key":"2023071905090581200_c23","doi-asserted-by":"publisher","first-page":"1982","DOI":"10.1016\/j.ultrasmedbio.2009.07.001","article-title":"Noninvasive thrombolysis using pulsed ultrasound cavitation therapy\u2014Histotripsy","volume":"35","year":"2009","journal-title":"Ultrasound Med. Biol."},{"key":"2023071905090581200_c24","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1148\/radiol.2401050717","article-title":"Uterine leiomyomas: MR imaging-based thermometry and thermal dosimetry during focused ultrasound thermal ablation","volume":"240","year":"2006","journal-title":"Radiology"},{"key":"2023071905090581200_c25","volume-title":"On Food and Cooking: The Science and Lore of the Kitchen","year":"2004"},{"key":"2023071905090581200_c26","doi-asserted-by":"publisher","first-page":"6353","DOI":"10.1088\/0031-9155\/54\/20\/021","article-title":"Thermal ablation produced using a surgical toroidal high-intensity focused ultrasound device is independent from hepatic inflow occlusion","volume":"54","year":"2009","journal-title":"Phys. Med. Biol."},{"key":"2023071905090581200_c27","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1016\/S0301-5629(97)00277-9","article-title":"Validation of a new blood mimicking fluid for use in Doppler flow test objects","volume":"24","year":"1998","journal-title":"Ultrasound Med. Biol."},{"key":"2023071905090581200_c28","doi-asserted-by":"publisher","first-page":"275","DOI":"10.4103\/0971-6203.29198","article-title":"An ideal blood mimicking fluid for Doppler ultrasound phantoms","volume":"31","year":"2006","journal-title":"Med. Phys."},{"key":"2023071905090581200_c29","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1016\/j.thromres.2009.01.008","article-title":"Ultrasound-enhanced thrombolysis with tPA-loaded echogenic liposome","volume":"124","year":"2009","journal-title":"Thromb. Res."},{"key":"2023071905090581200_c30","article-title":"Effects of dose-dependent absorption on heating and lesion formation","year":"2009"},{"key":"2023071905090581200_c31","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1148\/radiol.2431060167","article-title":"Enhancement of vascular permeability with low frequency contrast ultrasound","volume":"243","year":"2007","journal-title":"Radiology"},{"key":"2023071905090581200_c32","year":"2007"},{"key":"2023071905090581200_c33","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1080\/02656730601186138","article-title":"High intensity focused ultrasound: Physical principles and devices","volume":"23","year":"2007","journal-title":"Int. J. Hyperthermia"},{"key":"2023071905090581200_c34","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1080\/02656730601169779","article-title":"Hemorrhage control using high intensity focused ultrasound","volume":"23","year":"2007","journal-title":"Int. J. Hyperthermia"},{"key":"2023071905090581200_c35","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1002\/mrm.21271","article-title":"Influence of perfusion on high-intensity focused ultrasound prostate ablation: A first-pass MRI study","volume":"58","year":"2007","journal-title":"Magn. Reson. Med."},{"key":"2023071905090581200_c36","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/j.ultrasmedbio.2003.09.003","article-title":"Attenuation of porcine tissues in vivo after high-intensity ultrasound treatment","volume":"30","year":"2004","journal-title":"Ultrasound Med. Biol."}],"container-title":["The Journal of the Acoustical Society of America"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/asa\/jasa\/article-pdf\/128\/1\/480\/15293809\/480_1_online.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/asa\/jasa\/article-pdf\/128\/1\/480\/15293809\/480_1_online.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,19]],"date-time":"2023-07-19T14:17:49Z","timestamp":1689776269000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/jasa\/article\/128\/1\/480\/655972\/Egg-white-as-a-blood-coagulation-surrogate"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,7,1]]},"references-count":36,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2010,7,1]]}},"URL":"https:\/\/doi.org\/10.1121\/1.3442361","relation":{},"ISSN":["0001-4966","1520-8524"],"issn-type":[{"value":"0001-4966","type":"print"},{"value":"1520-8524","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2010,7]]},"published":{"date-parts":[[2010,7,1]]}}}