{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T08:47:55Z","timestamp":1740127675425,"version":"3.37.3"},"reference-count":27,"publisher":"Acoustical Society of America (ASA)","issue":"5","content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2012,11,1]]},"abstract":"<jats:p>Consonant recognition was measured as a function of the number of stimulation channels for Hybrid short-electrode cochlear implant (CI) users, long-electrode CI users, and normal-hearing (NH) listeners in quiet and background noise. Short-electrode CI subjects were tested with 1\u20136 channels allocated to a frequency range of 1063\u20137938 Hz. Long-electrode CI subjects were tested with 1\u20136, 8, or 22 channels allocated to 188\u20137938\u2009Hz, or 1\u20136 or 15 channels from the basal 15 electrodes allocated to 1063\u20137938\u2009Hz. NH listeners were tested with simulations of each CI group\/condition. Despite differences in intracochlear electrode spacing for equivalent channel conditions, all CI subject groups performed similarly at each channel condition and improved up to at least four channels in quiet and noise. All CI subject groups underperformed relative to NH subjects. These preliminary findings suggest that the limited channel benefit seen for CI users may not be due solely to increases in channel interactions as a function of electrode density. Other factors such as pre-operative patient history, location of stimulation in the base versus apex, or a limit on the number of electric channels that can be processed cognitively, may also interact with the effects of electrode contact spacing along the cochlea.<\/jats:p>","DOI":"10.1121\/1.4757735","type":"journal-article","created":{"date-parts":[[2012,11,8]],"date-time":"2012-11-08T23:20:09Z","timestamp":1352416809000},"page":"3406-3417","update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":9,"title":["Consonant recognition as a function of the number of stimulation channels in the Hybrid short-electrode cochlear implant"],"prefix":"10.1121","volume":"132","author":[{"given":"Lina A. J.","family":"Reiss","sequence":"first","affiliation":[{"name":"University of Iowa Department of Communication Sciences and Disorders, , Iowa City, Iowa 52242"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher W.","family":"Turner","sequence":"additional","affiliation":[{"name":"University of Iowa Department of Communication Sciences and Disorders, , Iowa City, Iowa 52242"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sue A.","family":"Karsten","sequence":"additional","affiliation":[{"name":"University of Iowa Department of Communication Sciences and Disorders, , Iowa City, Iowa 52242"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sheryl R.","family":"Erenberg","sequence":"additional","affiliation":[{"name":"University of Iowa Department of Communication Sciences and Disorders, , Iowa City, Iowa 52242"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jessica","family":"Taylor","sequence":"additional","affiliation":[{"name":"University of Iowa Department of Communication Sciences and Disorders, , Iowa City, Iowa 52242"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bruce J.","family":"Gantz","sequence":"additional","affiliation":[{"name":"University of Iowa Department of Otolaryngology\u2013Head Neck Surgery, , Iowa City, Iowa 52242"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"231","published-online":{"date-parts":[[2012,11,8]]},"reference":[{"key":"2023072820091858100_c1","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1016\/j.otohns.2007.01.006","article-title":"Nucleus Freedom North American clinical trial","volume":"136","year":"2007","journal-title":"Otolaryngol.-Head Neck Surg."},{"issue":"6","key":"2023072820091858100_c2","doi-asserted-by":"publisher","first-page":"758","DOI":"10.1097\/AUD.0b013e3182234c45","article-title":"Relative importance of monaural sound deprivation and bilateral significant hearing loss in predicting cochlear implantation outcomes","volume":"32","year":"2011","journal-title":"Ear Hear."},{"issue":"4","key":"2023072820091858100_c3","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1097\/00003446-200008000-00004","article-title":"Electrode discrimination by early-deafened subjects using the cochlear limited multiple-electrode cochlear implant","volume":"21","year":"2000","journal-title":"Ear. Hear."},{"key":"2023072820091858100_c4","doi-asserted-by":"publisher","first-page":"962","DOI":"10.1097\/MAO.0b013e3182204526","article-title":"Implications of minimizing trauma during conventional cochlear implantation","volume":"32","year":"2011","journal-title":"Otol. Neurotol."},{"key":"2023072820091858100_c5","doi-asserted-by":"crossref","first-page":"1201","DOI":"10.1044\/jslhr.4005.1201","article-title":"Speech recognition as a function of the number of electrodes used in the SPEAK cochlear implant speech processor","volume":"40","year":"1997","journal-title":"J. Speech Lang. Hear. Res."},{"key":"2023072820091858100_c6","doi-asserted-by":"publisher","first-page":"1150","DOI":"10.1121\/1.1381538","article-title":"Speech recognition in noise as a function of the number of spectral channels: Comparison of acoustic hearing and cochlear implants","volume":"110","year":"2001","journal-title":"J. Acoust. Soc. Am."},{"issue":"2","key":"2023072820091858100_c7","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1007\/s10162-005-5061-6","article-title":"Auditory training with spectrally shifted speech: Implications for cochlear implant patient auditory rehabilitation","volume":"6","year":"2005","journal-title":"J. Assoc. Res. Otolaryngol."},{"key":"2023072820091858100_c8","doi-asserted-by":"publisher","first-page":"1726","DOI":"10.1097\/00005537-200310000-00012","article-title":"Combining acoustic and electric hearing","volume":"113","year":"2003","journal-title":"Laryngoscope"},{"key":"2023072820091858100_c9","doi-asserted-by":"publisher","first-page":"344","DOI":"10.1080\/00016480410016423","article-title":"Combining acoustic and electric speech processing: Iowa\/Nucleus Hybrid Implant","volume":"24","year":"2004","journal-title":"Acta Otolaryngol."},{"key":"2023072820091858100_c10","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1159\/000095608","article-title":"Music perception with cochlear implants and residual hearing","volume":"11","year":"2006","journal-title":"Audiol. Neuro-Otol."},{"issue":"6","key":"2023072820091858100_c11","doi-asserted-by":"publisher","first-page":"2592","DOI":"10.1121\/1.399052","volume":"87","year":"1990","journal-title":"J. Acoust. Soc. Am."},{"issue":"3","key":"2023072820091858100_c12","doi-asserted-by":"publisher","first-page":"1269","DOI":"10.1121\/1.1287711","article-title":"The relationship between speech perception and electrode discrimination in cochlear implantees","volume":"108","year":"2000","journal-title":"J. Acoust. Soc. Am."},{"key":"2023072820091858100_c13","doi-asserted-by":"publisher","first-page":"1049","DOI":"10.1001\/archotol.131.12.1049","article-title":"Predictive models for cochlear implantation in elderly candidates","volume":"131","year":"2005","journal-title":"Arch. Otolaryngol. Head Neck Surg."},{"key":"2023072820091858100_c14","doi-asserted-by":"publisher","first-page":"338","DOI":"10.1121\/1.1907526","article-title":"An analysis of perceptual confusions among some English consonants","volume":"27","year":"1955","journal-title":"J. Acoust. Soc. Am."},{"issue":"4","key":"2023072820091858100_c15","doi-asserted-by":"publisher","first-page":"1987","DOI":"10.1121\/1.413317","article-title":"Electrode ranking of \u2018place pitch\u2019 and speech recognition in electric hearing","volume":"98","year":"1995","journal-title":"J. Acoust. Soc. Am."},{"key":"2023072820091858100_c16","doi-asserted-by":"publisher","first-page":"2236","DOI":"10.1121\/1.2537501","article-title":"Effects of carrier pulse rate and stimulation site on modulation detection by subjects with cochlear implants","volume":"121","year":"2007","journal-title":"J. Acoust. Soc. Am."},{"issue":"2","key":"2023072820091858100_c17a","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1097\/mao.0b013e31815aedf4","article-title":"Cochlear implant speech processor frequency allocations may influence pitch perception","volume":"29","year":"2008","journal-title":"Otol. Neurotol."},{"issue":"2","key":"2023072820091858100_c18","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1007\/s10162-007-0077-8","article-title":"Changes in pitch with a cochlear implant over time","volume":"8","year":"2007","journal-title":"J. Assoc. Res. Otolaryngol."},{"key":"2023072820091858100_c19","doi-asserted-by":"publisher","first-page":"3629","DOI":"10.1121\/1.428215","article-title":"Adaptation by normal listeners to upward spectral shifts of speech: Implications for cochlear implants","volume":"106","year":"1999","journal-title":"J. Acoust. Soc. Am."},{"key":"2023072820091858100_c20","first-page":"445","article-title":"Residual speech recognition and cochlear implant performance: Effects of implantation criteria","volume":"20","year":"1999","journal-title":"Am. J. Otol."},{"key":"2023072820091858100_c21","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1126\/science.270.5234.303","article-title":"Speech recognition with primarily temporal cues","volume":"270","year":"1995","journal-title":"Science"},{"issue":"3","key":"2023072820091858100_c22","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1097\/AUD.0b013e318234efd5","article-title":"Spread of excitation and channel interaction in single- and dual-electrode cochlear implant stimulation","volume":"33","year":"2012","journal-title":"Ear. Hear."},{"key":"2023072820091858100_c23","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1007\/s10162-007-0076-9","article-title":"Frequency map for the human cochlear spiral ganglion","volume":"8","year":"2007","journal-title":"J. Assoc. Res. Otolaryngol."},{"key":"2023072820091858100_c25","doi-asserted-by":"publisher","first-page":"2568","DOI":"10.1121\/1.411911","article-title":"Use of temporal envelope cues in speech recognition by normal and hearing-impaired listeners","volume":"97","year":"1995","journal-title":"J. Acoust. Soc. Am."},{"issue":"1\u20132","key":"2023072820091858100_c26","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1016\/j.heares.2007.12.010","article-title":"Spectral and temporal cues for speech recognition: Implications for auditory prostheses","volume":"242","year":"2008","journal-title":"Hear. Res."},{"issue":"6","key":"2023072820091858100_c27","doi-asserted-by":"publisher","first-page":"3673","DOI":"10.1121\/1.420401","article-title":"Electrode discrimination and speech recognition in postlingually deafened adult cochlear implant subjects","volume":"102","year":"1997","journal-title":"J. Acoust. Soc. Am."},{"key":"2023072820091858100_c28","unstructured":"See supplementary material at http:\/\/dx.doi.org\/10.1121\/1.4757735 for details of active electrodes and frequency allocations for each channel condition, for group mean and standard deviation values, and for details of pair-wise comparison results across groups."}],"container-title":["The Journal of the Acoustical Society of America"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/asa\/jasa\/article-pdf\/132\/5\/3406\/15305242\/3406_1_online.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/asa\/jasa\/article-pdf\/132\/5\/3406\/15305242\/3406_1_online.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,28]],"date-time":"2023-07-28T20:09:28Z","timestamp":1690574968000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/jasa\/article\/132\/5\/3406\/854345\/Consonant-recognition-as-a-function-of-the-number"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,11,1]]},"references-count":27,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2012,11,1]]}},"URL":"https:\/\/doi.org\/10.1121\/1.4757735","relation":{},"ISSN":["0001-4966","1520-8524"],"issn-type":[{"type":"print","value":"0001-4966"},{"type":"electronic","value":"1520-8524"}],"subject":[],"published-other":{"date-parts":[[2012,11]]},"published":{"date-parts":[[2012,11,1]]}}}