{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T16:00:22Z","timestamp":1784736022169,"version":"3.55.0"},"reference-count":46,"publisher":"Acoustical Society of America (ASA)","issue":"1","content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2013,7,1]]},"abstract":"<jats:p>The aim of this study is to further explore the relationship between distortion-product otoacoustic emission (DPOAE) measurements and categorical loudness scaling (CLS) measurements using multiple linear regression (MLR) analysis. Recently, Thorson et al. [J. Acoust. Soc. Am. 131, 1282\u20131295 (2012)] obtained predictions of CLS loudness ratings from DPOAE input\/output (I\/O) functions using MLR analysis. The present study extends that work by (1) considering two different (and potentially improved) MLR models, one for predicting loudness rating at specified input level and the other for predicting the input level for each loudness category and (2) validating the new models' predictions using an independent set of data. Strong correlations were obtained between predicted and measured data during the validation process with overall root-mean-square errors in the range 10.43\u201316.78\u2009dB for the prediction of CLS input level, supporting the view that DPOAE I\/O measurements can predict CLS loudness ratings and input levels, and thus may be useful for fitting hearing aids.<\/jats:p>","DOI":"10.1121\/1.4807560","type":"journal-article","created":{"date-parts":[[2013,7,11]],"date-time":"2013-07-11T22:16:22Z","timestamp":1373580982000},"page":"369-383","update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":15,"title":["Relation of distortion-product otoacoustic emission input-output functions to loudness"],"prefix":"10.1121","volume":"134","author":[{"given":"Daniel M.","family":"Rasetshwane","sequence":"first","affiliation":[{"name":"Boys Town National Research Hospital , 555 North 30th Street, Omaha, Nebraska 68131"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen T.","family":"Neely","sequence":"additional","affiliation":[{"name":"Boys Town National Research Hospital , 555 North 30th Street, Omaha, Nebraska 68131"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Judy G.","family":"Kopun","sequence":"additional","affiliation":[{"name":"Boys Town National Research Hospital , 555 North 30th Street, Omaha, Nebraska 68131"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael P.","family":"Gorga","sequence":"additional","affiliation":[{"name":"Boys Town National Research Hospital , 555 North 30th Street, Omaha, Nebraska 68131"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"231","published-online":{"date-parts":[[2013,7,11]]},"reference":[{"key":"2023071623050690900_c1","first-page":"99","article-title":"Derecruitment by multiband compression in hearing aids","volume-title":"Modeling Sensorineural Hearing Loss","author":"Jesteadt","year":"1997"},{"key":"2023071623050690900_c2","doi-asserted-by":"publisher","first-page":"745","DOI":"10.1121\/1.399778","article-title":"Loudness growth in 1\/2-octave bands (LGOB)\u2014A procedure for the assessment of loudness","volume":"88","year":"1990","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c3","doi-asserted-by":"publisher","first-page":"567","DOI":"10.1097\/AUD.0b013e3181da4d15","article-title":"Reliability of categorical loudness scaling and its relation to threshold","volume":"31","year":"2010","journal-title":"Ear Hear."},{"key":"2023071623050690900_c4","doi-asserted-by":"publisher","first-page":"1810","DOI":"10.1121\/1.1460923","article-title":"Pure-tone threshold estimation from extrapolated distortion product otoacoustic emissions I\/O-functions in normal and cochlear hearing loss ears","volume":"111","year":"2002","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c5","doi-asserted-by":"publisher","first-page":"1597","DOI":"10.1121\/1.1502902","article-title":"An adaptive procedure for categorical loudness scaling","volume":"112","year":"2002","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c6","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1097\/00003446-199004000-00003","article-title":"Outer hair cell electromotility and otoacoustic emissions","volume":"11","year":"1990","journal-title":"Ear Hear."},{"issue":"10","key":"2023071623050690900_c7","first-page":"39","article-title":"Using loudness data for hearing aid selection: The IHAFF approach","volume":"48","year":"1995","journal-title":"Hear. J."},{"key":"2023071623050690900_c8","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1097\/00003446-200412000-00006","article-title":"Effects of a suppressor tone on distortion product otoacoustic emissions fine structure: Why a universal suppressor level is not a practical solution to obtaining single-generator DP-grams","volume":"25","year":"2004","journal-title":"Ear Hear."},{"key":"2023071623050690900_c9","doi-asserted-by":"publisher","first-page":"3119","DOI":"10.1121\/1.1417524","article-title":"Distortion product otoacoustic emission input\/output functions in normal-hearing and hearing-impaired human ears","volume":"110","year":"2001","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c10","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1097\/00003446-199904000-00006","article-title":"Predicting audiometric status from distortion product otoacoustic emissions using multivariate analyses","volume":"20","year":"1999","journal-title":"Ear Hear."},{"key":"2023071623050690900_c11","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1121\/1.1830670","article-title":"Inferring basilar-membrane motion from tone-burst otoacoustic emissions and psychoacoustic measurements","volume":"117","year":"2005","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c12","doi-asserted-by":"publisher","first-page":"3855","DOI":"10.1121\/1.3106531","article-title":"Analysis of parameters for the estimation of loudness from tone-burst otoacoustic emissions","volume":"125","year":"2009","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c13","first-page":"89","article-title":"Correlates of loudness","volume-title":"Springer Handbook of Auditory Research: Loudness","author":"Florentine","year":"2011"},{"key":"2023071623050690900_c14","first-page":"1","article-title":"Loudness: Its definition, measurement, and calculations","volume":"9","year":"1933","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c15","volume-title":"Applied Regression Analysis and Generalized Linear Models","year":"2008","edition":"2nd ed."},{"key":"2023071623050690900_c16","doi-asserted-by":"publisher","first-page":"593","DOI":"10.1097\/01.aud.0000188108.08713.6c","article-title":"A validation and potential clinical application of multivariate analyses of distortion-product otoacoustic emission data","volume":"26","year":"2005","journal-title":"Ear Hear."},{"key":"2023071623050690900_c17","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1097\/00003446-199908000-00007","article-title":"Distortion product otoacoustic emission test performance for a priori criteria and for multifrequency audiometric standards","volume":"20","year":"1999","journal-title":"Ear Hear."},{"key":"2023071623050690900_c18","doi-asserted-by":"publisher","first-page":"3275","DOI":"10.1121\/1.1570433","article-title":"Further efforts to predict pure-tone thresholds from distortion product otoacoustic emission input\/output functions","volume":"113","year":"2003","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c19","doi-asserted-by":"publisher","first-page":"440","DOI":"10.1097\/00003446-199712000-00003","article-title":"From laboratory to clinic: A large scale study of distortion product otoacoustic emissions in ears with normal hearing and ears with hearing loss","volume":"18","year":"1997","journal-title":"Ear Hear."},{"key":"2023071623050690900_c20","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1007\/s10162-004-5043-0","article-title":"Auditory-nerve rate responses are inconsistent with common hypotheses for the neural correlates of loudness recruitment","volume":"6","year":"2005","journal-title":"J. Assoc. Res. Otolaryngol."},{"key":"2023071623050690900_c21","doi-asserted-by":"publisher","first-page":"434","DOI":"10.1097\/00003446-199812000-00005","article-title":"Transient evoked otoacoustic emissions in patients with normal hearing and in patients with hearing loss","volume":"19","year":"1998","journal-title":"Ear Hear."},{"key":"2023071623050690900_c22","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1121\/1.2133714","article-title":"Influence of primary-level and primary-frequency ratios on human distortion product otoacoustic emissions","volume":"119","year":"2006","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c23","doi-asserted-by":"publisher","first-page":"3539","DOI":"10.1121\/1.2799474","article-title":"Distortion product otoacoustic emissions: Cochlear-source contributions and clinical test performance","volume":"122","year":"2007","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c24","doi-asserted-by":"publisher","first-page":"3896","DOI":"10.1121\/1.2200048","article-title":"Reducing reflected contributions to ear-canal distortion product otoacoustic emissions in humans","volume":"119","year":"2006","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c25","doi-asserted-by":"publisher","first-page":"622","DOI":"10.1121\/1.1334597","article-title":"Distortion-product source unmixing: a test of the two-mechanism model for DPOAE generation","volume":"109","year":"2001","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c26","doi-asserted-by":"publisher","first-page":"230","DOI":"10.1097\/AUD.0b013e3181fa5da2","article-title":"Do \u2018optimal\u2019 conditions improve distortion product otoacoustic emission test performance?","volume":"32","year":"2011","journal-title":"Ear Hear."},{"key":"2023071623050690900_c27","doi-asserted-by":"publisher","first-page":"3431","DOI":"10.1121\/1.423054","article-title":"The level and growth behavior of the 2f1-f2 distortion product otoacoustic emission and its relationship to auditory sensitivity in normal hearing and cochlear hearing loss","volume":"103","year":"1998","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c28","first-page":"156","article-title":"Categorical loudness scaling in hearing-impaired listeners\u2014Can loudness growth be predicted from the audiogram?","volume":"4","year":"1996","journal-title":"Audiol. Akust."},{"key":"2023071623050690900_c29","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1007\/s10162-012-0327-2","article-title":"Behavioral estimates of the contribution of inner and outer hair cell dysfunction to individualized audiometric loss","volume":"13","year":"2012","journal-title":"J. Assoc. Res. Otolaryngol."},{"key":"2023071623050690900_c30","doi-asserted-by":"publisher","first-page":"2199","DOI":"10.1121\/1.1791719","article-title":"Distortion product otoacoustic emission (DPOAE) input\/output functions and the influence of the second DPOAE source","volume":"116","year":"2004","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c31","first-page":"70","article-title":"A revised model of loudness perception applied to cochlear hearing loss","volume":"188","year":"2003","journal-title":"Hear. Res."},{"key":"2023071623050690900_c32","doi-asserted-by":"publisher","first-page":"205","DOI":"10.3109\/03005364000000131","article-title":"A test for the diagnosis of dead regions in the cochlea","volume":"34","year":"2000","journal-title":"Br. J. Aud."},{"key":"2023071623050690900_c33","doi-asserted-by":"publisher","first-page":"3081","DOI":"10.1121\/1.1736292","article-title":"Similarity in loudness and distortion product otoacoustic emission input\/output functions: Implications for an objective hearing aid adjustment","volume":"115","year":"2004","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c34","doi-asserted-by":"publisher","first-page":"1499","DOI":"10.1121\/1.1604122","article-title":"Cochlear compression estimates from measurements of distortion-product otoacoustic emissions","volume":"114","year":"2003","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c35","doi-asserted-by":"publisher","first-page":"1248","DOI":"10.1121\/1.1853253","article-title":"Distortion product otoacoustic emission measured with continuously varying stimulus level","volume":"117","year":"2005","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c36","doi-asserted-by":"publisher","first-page":"728","DOI":"10.1121\/1.3158859","article-title":"Distortion-product otoacoustic emission input\/output characteristics in normal-hearing and hearing-impaired human ears","volume":"126","year":"2009","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c37","unstructured":"Neely, S. T., and Liu, Z. (1994). \u201cEMAV: Otoacoustic emission averager,\u201d Technical Memo No. 17, Boys Town National Research Hospital, Omaha, NE."},{"key":"2023071623050690900_c38","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1078\/0939-3889-00148","article-title":"Weighted DPOAE input\/output functions: A tool for automatic assessment of hearing loss in clinical application","volume":"13","year":"2003","journal-title":"Z. Med. Phys."},{"key":"2023071623050690900_c39","doi-asserted-by":"publisher","first-page":"2735","DOI":"10.1121\/1.418561","article-title":"Is loudness simply proportional to the auditory nerve spike count?\u201d","volume":"101","year":"1997","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c40","doi-asserted-by":"publisher","first-page":"3134","DOI":"10.1121\/1.3569726","article-title":"Distribution of standing-wave errors in real-ear sound-level measurements","volume":"129","year":"2011","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c41","doi-asserted-by":"publisher","first-page":"546","DOI":"10.1097\/AUD.0b013e3181d86b59","article-title":"Influence of calibration method on distortion-product otoacoustic emission measurements: II. Threshold predication","volume":"31","year":"2010","journal-title":"Ear Hear."},{"key":"2023071623050690900_c42","first-page":"187","article-title":"Loudness","volume-title":"Handbook of Perception: Vol. IV. Hearing","author":"Carterette","year":"1978"},{"key":"2023071623050690900_c43","doi-asserted-by":"publisher","first-page":"288","DOI":"10.1121\/1.2931953","article-title":"Influence of in-situ sound level calibration on distortion product otoacoustic emission variability","volume":"124","year":"2008","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c44","first-page":"223","article-title":"Loudness and hearing loss","volume-title":"Springer Handbook of Auditory Research: Loudness","author":"Florentine","year":"2011"},{"key":"2023071623050690900_c45","doi-asserted-by":"publisher","first-page":"1282","DOI":"10.1121\/1.3672654","article-title":"Reliability of distortion-product otoacoustic emissions and their relation to loudness","volume":"131","year":"2012","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071623050690900_c46","doi-asserted-by":"publisher","first-page":"315","DOI":"10.3109\/00206099809072986","article-title":"Multi-variant analysis of otoacoustic emissions and estimation of hearing threshold: Transient evoked otoacoustic emissions","volume":"37","year":"1998","journal-title":"Audiology"}],"container-title":["The Journal of the Acoustical Society of America"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/asa\/jasa\/article-pdf\/134\/1\/369\/15303461\/369_1_online.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/asa\/jasa\/article-pdf\/134\/1\/369\/15303461\/369_1_online.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,16]],"date-time":"2023-07-16T23:05:19Z","timestamp":1689548719000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/jasa\/article\/134\/1\/369\/614331\/Relation-of-distortion-product-otoacoustic"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,7,1]]},"references-count":46,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2013,7,1]]}},"URL":"https:\/\/doi.org\/10.1121\/1.4807560","relation":{},"ISSN":["0001-4966","1520-8524"],"issn-type":[{"value":"0001-4966","type":"print"},{"value":"1520-8524","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2013,7]]},"published":{"date-parts":[[2013,7,1]]}}}