{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T17:08:58Z","timestamp":1782925738859,"version":"3.54.5"},"reference-count":8,"publisher":"Acoustical Society of America (ASA)","issue":"1","license":[{"start":{"date-parts":[[2017,7,5]],"date-time":"2017-07-05T00:00:00Z","timestamp":1499212800000},"content-version":"vor","delay-in-days":4,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2017,7,5]],"date-time":"2017-07-05T00:00:00Z","timestamp":1499212800000},"content-version":"tdm","delay-in-days":4,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2017,7,1]]},"abstract":"<jats:p>Distortion product otoacoustic emissions (DPOAEs) have been accurately measured with an intensimetric technique, involving simultaneous measure of pressure and velocity in the ear canal, which allows one to correctly calibrate both the input stimuli and the otoacoustic emission (OAE) level. Suitable combinations of standard intensimetric quantities, active intensity and power density [Stanzial, Shiffrer, and Sacchi, J. Acoust. Soc. Am. 131, 269\u2013280 (2012)], are used to equalize the stimuli transmitted to the middle ear, and to estimate the DPOAE level emitted by the eardrum. The DPOAE intensimetric spectra are consistent with those recorded with a high-quality conventional otoacoustic probe with state-of-the-art calibration of both stimulus and OAE response [Charaziak and Shera, J. Acoust. Soc. Am. 141, 515\u2013525 (2017)], demonstrating the applicability of the intensimetric method to OAE measurements.<\/jats:p>","DOI":"10.1121\/1.4990011","type":"journal-article","created":{"date-parts":[[2017,7,5]],"date-time":"2017-07-05T14:12:56Z","timestamp":1499263976000},"page":"EL13-EL17","update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":1,"title":["Intensimetric detection of distortion product otoacoustic emissions with ear canal calibration"],"prefix":"10.1121","volume":"142","author":[{"given":"Renata","family":"Sisto","sequence":"first","affiliation":[{"name":"Department of Occupational and Environmental Medicine, Epidemiology and Hygiene, Italian Workers Compensation Authority (INAIL) Research , Monte Porzio Catone (RM), Italy \u2008 r.sisto@inail.it , l.cerini@inail.it , f.sanjust@inail.it"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luigi","family":"Cerini","sequence":"additional","affiliation":[{"name":"Department of Occupational and Environmental Medicine, Epidemiology and Hygiene, Italian Workers Compensation Authority (INAIL) Research , Monte Porzio Catone (RM), Italy \u2008 r.sisto@inail.it , l.cerini@inail.it , f.sanjust@inail.it"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Filippo","family":"Sanjust","sequence":"additional","affiliation":[{"name":"Department of Occupational and Environmental Medicine, Epidemiology and Hygiene, Italian Workers Compensation Authority (INAIL) Research , Monte Porzio Catone (RM), Italy \u2008 r.sisto@inail.it , l.cerini@inail.it , f.sanjust@inail.it"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arturo","family":"Moleti","sequence":"additional","affiliation":[{"name":"Department of Physics, University of Roma Tor Vergata , Roma, Italy \u2008 moleti@roma2.infn.it"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"231","published-online":{"date-parts":[[2017,7,5]]},"reference":[{"key":"2023071900544349100_c1","doi-asserted-by":"publisher","first-page":"2027","DOI":"10.1121\/1.400897","article-title":"A review of otoacoustic emissions","volume":"89","year":"1991","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071900544349100_c2","doi-asserted-by":"publisher","first-page":"515","DOI":"10.1121\/1.4973618","article-title":"Compensating for ear-canal acoustics when measuring otoacoustic emissions","volume":"141","year":"2017","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071900544349100_c3","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1121\/1.3664051","article-title":"On the physical meaning of the power factor in acoustics","volume":"131","year":"2012","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071900544349100_c4","first-page":"1","article-title":"Estimation of pressure at the eardrum in magnitude and phase for headphone equalization using pressure-velocity measurements at the ear canal entrance","year":"2015"},{"key":"2023071900544349100_c5","first-page":"289","article-title":"Estimating pressure at eardrum with pressure-velocity measurement from ear canal entrance","year":"2009"},{"key":"2023071900544349100_c6","doi-asserted-by":"publisher","first-page":"1768","DOI":"10.1121\/1.4894787","article-title":"Comparison of nine methods to estimate ear-canal stimulus levels","volume":"136","year":"2014","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071900544349100_c7","doi-asserted-by":"publisher","first-page":"782","DOI":"10.1121\/1.426948","article-title":"Evoked otoacoustic emissions arise by two fundamentally different mechanisms: A taxonomy for mammalian OAEs","volume":"105","year":"1999","journal-title":"J. Acoust. Soc. Am."},{"key":"2023071900544349100_c8","doi-asserted-by":"publisher","first-page":"2455","DOI":"10.1121\/1.4751537","article-title":"Time-frequency domain filtering of evoked otoacoustic emissions","volume":"132","year":"2012","journal-title":"J. Acoust. Soc. Am."}],"container-title":["The Journal of the Acoustical Society of America"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/asa\/jasa\/article-pdf\/142\/1\/EL13\/10753488\/el13_1_online.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/pubs.aip.org\/asa\/jasa\/article-pdf\/142\/1\/EL13\/10753488\/el13_1_online.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/asa\/jasa\/article-pdf\/142\/1\/EL13\/10753488\/el13_1_online.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,27]],"date-time":"2025-05-27T19:14:26Z","timestamp":1748373266000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/jasa\/article\/142\/1\/EL13\/662618\/Intensimetric-detection-of-distortion-product"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,7,1]]},"references-count":8,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017,7,1]]}},"URL":"https:\/\/doi.org\/10.1121\/1.4990011","relation":{},"ISSN":["0001-4966","1520-8524"],"issn-type":[{"value":"0001-4966","type":"print"},{"value":"1520-8524","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2017,7]]},"published":{"date-parts":[[2017,7,1]]}}}