{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T13:27:48Z","timestamp":1781011668466,"version":"3.54.1"},"reference-count":36,"publisher":"Acoustical Society of America (ASA)","issue":"2","funder":[{"name":"Government of Spain","award":["EQC2018-004988-P"],"award-info":[{"award-number":["EQC2018-004988-P"]}]}],"content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2020,8,1]]},"abstract":"<jats:p>Auditory evoked potentials (AEPs) include the auditory brainstem response (ABR), middle latency response (MLR), and cortical auditory evoked potentials (CAEPs), each one covering a specific latency range and frequency band. For this reason, ABR, MLR, and CAEP are usually recorded separately using different protocols. This article proposes a procedure providing a latency-dependent filtering and down-sampling of the AEP responses. This way, each AEP component is appropriately filtered, according to its latency, and the complete auditory pathway response is conveniently represented (with the minimum number of samples, i.e., without unnecessary redundancies). The compact representation of the complete response facilitates a comprehensive analysis of the evoked potentials (keeping the natural continuity related to the neural activity transmission along the auditory pathway), which provides a new perspective in the design and analysis of AEP experiments. Additionally, the proposed compact representation reduces the storage or transmission requirements when large databases are manipulated for clinical or research purposes. The analysis of the AEP responses shows that a compact representation with 40 samples\/decade (around 120 samples) is enough for accurately representing the response of the complete auditory pathway and provides appropriate latency-dependent filtering. MatLab\/Octave code implementing the proposed procedure is included in the supplementary materials.<\/jats:p>","DOI":"10.1121\/10.0001673","type":"journal-article","created":{"date-parts":[[2020,8,4]],"date-time":"2020-08-04T16:42:13Z","timestamp":1596559333000},"page":"599-613","update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":9,"title":["Latency-dependent filtering and compact representation of the complete auditory pathway response"],"prefix":"10.1121","volume":"148","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9736-5190","authenticated-orcid":false,"given":"Angel","family":"de la Torre","sequence":"first","affiliation":[{"name":"Department of Signal Theory, Telematics, and Communications, University of Granada 1 , Granada, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5529-8620","authenticated-orcid":false,"given":"Joaquin T.","family":"Valderrama","sequence":"additional","affiliation":[{"name":"National Acoustic Laboratories 2 , Sydney, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3746-0978","authenticated-orcid":false,"given":"Jose C.","family":"Segura","sequence":"additional","affiliation":[{"name":"Department of Signal Theory, Telematics, and Communications, University of Granada 1 , Granada, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Isaac M.","family":"Alvarez","sequence":"additional","affiliation":[{"name":"Department of Signal Theory, Telematics, and Communications, University of Granada 1 , Granada, Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"231","published-online":{"date-parts":[[2020,8,4]]},"reference":[{"key":"2023080305311408100_c1","doi-asserted-by":"publisher","first-page":"727","DOI":"10.1016\/j.clinph.2013.09.030","article-title":"Least-squares deconvolution of evoked potentials and sequence optimization for multiple stimuli under low-jitter conditions","volume":"125","year":"2014","journal-title":"Clinic. Neurophysiol."},{"key":"2023080305311408100_c2","doi-asserted-by":"publisher","first-page":"814","DOI":"10.1016\/j.clinph.2013.09.031","article-title":"Deconvolution of overlapping cortical auditory evoked potentials recorded using short stimulus onset-asynchrony ranges","volume":"125","year":"2014","journal-title":"Clinic. Neurophysiol."},{"key":"2023080305311408100_c3","doi-asserted-by":"publisher","first-page":"2881","DOI":"10.1121\/1.2191609","article-title":"Signal to noise ratio analysis of maximum length sequence deconvolution of overlapping evoked potentials","volume":"119","year":"2006","journal-title":"J. Acoust. Soc. Am."},{"key":"2023080305311408100_c4","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1159\/000081544","article-title":"Automated analysis of the auditory brainstem response using derivative estimation wavelets","volume":"10","year":"2005","journal-title":"Audiol. Neuro-Otol."},{"key":"2023080305311408100_c5","first-page":"229","article-title":"The auditory brainstem response","volume-title":"Auditory Evoked Potentials: Basic Principles and Clinical Application","author":"Burkard","year":"2007"},{"key":"2023080305311408100_c6","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1016\/j.neuron.2019.02.039","article-title":"Filters: When, why, and how (not) to use them","volume":"102","year":"2019","journal-title":"Neuron"},{"key":"2023080305311408100_c7","doi-asserted-by":"publisher","first-page":"4545","DOI":"10.1121\/1.5139639","article-title":"Matrix-based formulation of the iterative randomized stimulation and averaging method for recording evoked potentials","volume":"146","year":"2019","journal-title":"J. Acoust. Soc. Am."},{"key":"2023080305311408100_c8","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1016\/j.bbe.2016.01.003","article-title":"Classification of auditory brainstem response using wavelet decomposition and SVM network","volume":"36","year":"2016","journal-title":"Biocybernet. Biomedic. Engineer."},{"key":"2023080305311408100_c9","doi-asserted-by":"publisher","first-page":"2091","DOI":"10.1121\/1.3677257","article-title":"Auditory brainstem responses to chirps delivered by different insert earphones","volume":"131","year":"2012","journal-title":"J. Acoust. Soc. Am."},{"key":"2023080305311408100_c10","doi-asserted-by":"publisher","first-page":"242","DOI":"10.3109\/00206098209072742","article-title":"Maximum length sequences: A fast method for measuring brain-stem-evoked responses","volume":"21","year":"1982","journal-title":"Audiology"},{"key":"2023080305311408100_c11","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1016\/0013-4694(82)90005-0","article-title":"Application of digital filtering and automatic peak detection to brain stem auditory evoked potential","volume":"53","year":"1982","journal-title":"Electroencephal. Clinic. Neurophysiol."},{"key":"2023080305311408100_c12","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.cell.2009.09.010","article-title":"Mechanotransduction by hair cells: Models, molecules, and mechanisms","volume":"139","year":"2009","journal-title":"Cell"},{"key":"2023080305311408100_c13","doi-asserted-by":"publisher","first-page":"1589","DOI":"10.1016\/j.clinph.2015.10.046","article-title":"Effects of rate (0.3\u201340\/s) on simultaneously recorded auditory brainstem, middle and late responses using deconvolution","volume":"127","year":"2016","journal-title":"Clinic. Neurophysiol."},{"key":"2023080305311408100_c14","doi-asserted-by":"publisher","first-page":"2754","DOI":"10.1016\/j.clinph.2004.06.014","article-title":"The use of QSD (q-sequence deconvolution) to recover superposed, transient evoked-responses","volume":"115","year":"2004","journal-title":"Clinic. Neurophysiol."},{"key":"2023080305311408100_c15","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1121\/10.0000493","article-title":"A model of auditory brainstem response wave I morphology","volume":"147","year":"2020","journal-title":"J. Acoust. Soc. Am."},{"key":"2023080305311408100_c16","doi-asserted-by":"publisher","first-page":"540","DOI":"10.1121\/1.5087825","article-title":"Fast acquisition of full-range auditory event-related potentials using an interleaved deconvolution approach","volume":"145","year":"2019","journal-title":"J. Acoust. Soc. Am."},{"key":"2023080305311408100_c17","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1016\/j.neuroimage.2010.03.053","article-title":"Baseline correction of overlapping event-related responses using a linear deconvolution technique","volume":"52","year":"2010","journal-title":"NeuroImage"},{"key":"2023080305311408100_c18","doi-asserted-by":"publisher","first-page":"e0441","DOI":"10.1523\/ENEURO.0441-17.2018","article-title":"Auditory brainstem responses to continuous natural speech in human listeners","volume":"5","year":"2018","journal-title":"eNeuro"},{"key":"2023080305311408100_c19","first-page":"482","article-title":"Principles and applications of cortical auditory evoked potentials","volume-title":"Auditory Evoked Potentials: Basic Principles and Clinical Application","author":"Burkard","year":"2007"},{"key":"2023080305311408100_c20","first-page":"227","article-title":"Lecture notes in computer science (including subseries lecture notes in artificial intelligence and lecture notes in bioinformatics)","year":"2019"},{"key":"2023080305311408100_c21","doi-asserted-by":"publisher","first-page":"429","DOI":"10.1121\/1.2133682","article-title":"Signal-to-noise ratio and frequency analysis of continuous loop averaging deconvolution (clad) of overlapping evoked potentials","volume":"119","year":"2006","journal-title":"J. Acoust. Soc. Am."},{"key":"2023080305311408100_c22","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/2331216519871395","article-title":"The parallel auditory brainstem response","volume":"23","year":"2019","journal-title":"Trends in Hearing"},{"key":"2023080305311408100_c23","first-page":"463","article-title":"Middle-latency responses","volume-title":"Auditory Evoked Potentials: Basic Principles and Clinical Application","author":"Burkard","year":"2007"},{"key":"2023080305311408100_c24","volume-title":"Digital Communications","year":"2008","edition":"5th ed."},{"key":"2023080305311408100_c25","first-page":"73","article-title":"Instrumentation and recording parameters","volume-title":"Auditory Evoked Potentials: Basic Principles and Clinical Application","author":"Burkard","year":"2007"},{"key":"2023080305311408100_c26","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1016\/0013-4694(75)90103-0","article-title":"The adaptation of cochlear and brainstem auditory evoked potentials in humans","volume":"39","year":"1975","journal-title":"Electroencephal. Clinic. Neurophysiol."},{"key":"2023080305311408100_c27","doi-asserted-by":"publisher","first-page":"205","DOI":"10.3109\/03005369309076694","article-title":"Auditory brainstem responses recorded at fast stimulation rates using maximum length sequences","volume":"27","year":"1993","journal-title":"Brit. J. Audiol."},{"key":"2023080305311408100_c28","doi-asserted-by":"publisher","first-page":"306","DOI":"10.1109\/TPAMI.1979.4766926","article-title":"A problem of dimensionality: A simple example","volume":"1","year":"1979","journal-title":"IEEE Trans. Patterns Analysis Mach. Intell."},{"key":"2023080305311408100_c29","doi-asserted-by":"publisher","first-page":"3856","DOI":"10.1121\/1.4764511","article-title":"Recording of auditory brainstem response at high stimulation rates using randomized stimulation and averaging","volume":"132","year":"2012","journal-title":"J. Acoust. Soc. Am."},{"key":"2023080305311408100_c30","first-page":"180","article-title":"A portable, modular, and low cost auditory brainstem response recording system including an algorithm for automatic identification of responses suitable for hearing screening","year":"2013"},{"key":"2023080305311408100_c31","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1515\/bmt-2014-0034","article-title":"A flexible and inexpensive high-performance auditory evoked response recording system appropriate for research purposes","volume":"59","year":"2014","journal-title":"Biomedic. Engineer. \/ Biomedizinische Technik"},{"key":"2023080305311408100_c32","doi-asserted-by":"publisher","first-page":"3233","DOI":"10.1121\/1.4900832","article-title":"Auditory brainstem and middle latency responses recorded at fast rates with randomized stimulation","volume":"136","year":"2014","journal-title":"J. Acoust. Soc. Am."},{"key":"2023080305311408100_c33","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1016\/j.cmpb.2014.02.015","article-title":"Automatic quality assessment and peak identification of auditory brainstem responses with fitted parametric peaks","volume":"114","year":"2014","journal-title":"Comput. Meth. Progr. Biomed."},{"key":"2023080305311408100_c34","doi-asserted-by":"publisher","first-page":"016008","DOI":"10.1088\/1741-2552\/aa8d95","article-title":"An automatic algorithm for blink-artifact suppression based on iterative template matching: Application to single cannel recording of cortical auditory evoked potentials","volume":"15","year":"2018","journal-title":"J. Neural Engineer."},{"key":"2023080305311408100_c35","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1016\/j.heares.2015.12.009","article-title":"Selective processing of auditory evoked responses with iterative-randomized stimulation and averaging: A strategy for evaluating the time-invariant assumption","volume":"333","year":"2016","journal-title":"Hear. Res."},{"key":"2023080305311408100_c36","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1111\/j.1469-8986.1993.tb03209.x","article-title":"Distortion of ERP averages due to overlap from temporally adjacent ERPs: Analysis and correction","volume":"30","year":"1993","journal-title":"Psychophysiol."}],"container-title":["The Journal of the Acoustical Society of America"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/asa\/jasa\/article-pdf\/148\/2\/599\/15344703\/599_1_online.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/asa\/jasa\/article-pdf\/148\/2\/599\/15344703\/599_1_online.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,3]],"date-time":"2023-08-03T05:31:27Z","timestamp":1691040687000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/jasa\/article\/148\/2\/599\/958158\/Latency-dependent-filtering-and-compact"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,1]]},"references-count":36,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,8,1]]}},"URL":"https:\/\/doi.org\/10.1121\/10.0001673","relation":{},"ISSN":["0001-4966","1520-8524"],"issn-type":[{"value":"0001-4966","type":"print"},{"value":"1520-8524","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2020,8]]},"published":{"date-parts":[[2020,8,1]]}}}